HomeMy WebLinkAboutNE - ENGINEERINGV
v
c
v
E
c
0
C
W
C
c
0
V
N
a
c
v
c
rn
c
Y
v
o,
c
QJ
v
C
0)
c
W
�o
ai
c
0
u
Y
N
c
0
70,
c
V
E
s
U
v
0
Q)
v
0
Nutting
UNIONS
of Florida Inc. I Established 1967
Your Project is Our Commitment
September 13, 2012
Mr. Rich Barnes
Bodax Foundations, Inc.
1101 NW 55`h Street
Ft. Lauderdale, Florida 33309
SCANNED
BY
St. Lucie County
Subject: Report of Augercast Pile Installation Monitoring
Steger Residence and Pool
8316 South Ocean Drive
Hutchinson Island, Port St. Lucie, Florida
Dear Mr. Barnes:
1310 Neptune Drive
Boynton Beach, Florida 33426
561-736-4900
Toll Free: 877-NUTTING (688-8464)
Fax: 561-737-9975
Broward 954-941-8700
St. Lucie 772-408-1050
Miami -Dade 305-557-3083
www.nuttingengineers.com
Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations
for the proposed residence at the subject site. Bodax Foundations, Inc. installed cast -in -place
augured piles for support of the proposed residence, pool, and pool deck.
Bodax Foundations, Inc. installed a total of 166, 16-inch diameter and 14-inch diameter
augercast piles for the project. The piles were installed from August 29, 2012 to September 11,
2012. The pile size, capacity, and depth recommendations were based upon a Geotechnical
Exploration prepared by A.M. Engineering and Testing for Phoenix Realty Homes, Inc. dated
December 14, 2010.
The pile installation characteristics of each pile are presented in the attached Pile Installation
Data. Identification of each pile location followed by the pile number is shown on the Pile
Location Plans attached. Each pile record in the attached summary tables shows the following
information:
) F F I C E S
'alm Beach
Aiami-Dade
1t. Lucie
■ RECORD NUMBER IN CHRONOLOGICAL ORDER
■ THE PILE NUMBER (AS FOUND ON ATTACHED PLANS)
■ THE DIAMETER OF THE PILE
■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP
■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE
■ THE NUMBER OF PUMP STROKES FOR THE PILE
■ THE ACTUAL VOLUME OF GROUT FOR THE PILE
■ THE GROUT FACTOR
■ THE DATE OF INSTALLATION
1
0
■ THE REINFORCEMENT TYPES
■ AND GENERAL COMMENTS AS NEEDED
The drilling operations were monitored in the field by our field engineer and inspector in order to
approximately determine the type of material being penetrated. This identification was done
based on the augering time, the materials received during the drilling operations and the relative
hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines.
We note that separate pile plans and separate pile numbers were provided in the attachment
section of this report for the main residence differing from the pool and pool deck.
The main residence piles consisted of a total of 133, 16-inch diameter augercast piles. Due to
improper layout of pile number 14 and 77, two additional piles were installed at the corrected
layout location. Because of this 135 piles were recorded for the main residence. The main
residence piles were designed for an allowable compressive capacity of 30 tons. The piles were
installed for the specified capacity as required by the structural specifications.
The pool and pool deck piles consisted of a total of 31, 14-inch diameter augercast piles. The
pool deck piles were designed for an allowable compressive capacity of 5 tons, while the pool
piles were designed for an allowable compressive capacity of 15 tons. The piles were installed
for the specified capacity as required by the structural specifications. We note that as indicated
on the structural plans, the nine pool piles were installed at an approximate 15-degree batter
angle. The pile was placed at the survey elevation and battered at that location as well.
All piles for the residence, pool and pool deck were installed to a depth of twenty-seven feet
below the existing ground surface which was at an approximate elevation of +9 NGVD. The
piles were installed at existing ground surface elevations. Generally, during the installation of
the piles, easy drilling was observed from the ground level to approximately ten to fifteen feet.
Below ten to fifteen feet medium drilling conditions was encountered for the remaining depth of
the pile.
All house piles received a steel cage consisting of six (6) #6 reinforcing steel bars with #3 ties
spaced 10 inches from center to center the full length of the pile as stated in the structural
specifications. All pool and pool deck piles received a steel cage consisting of four (4) #5
reinforcing steel bars with #3 ties spaced 12 inches from center to center the full length of the
pile as stated in the structural specifications.
Upon completion of this inspection process, and review of the recorded data, it is our opinion
that the augercast piles for the main residence attained the required design compressive capacity
of 30 tons, the pool piles attained the required design compressive capacity of 15 tons, and the
pool deck piles attained the required design compressive capacity of 5 tons. The piles that were
presently installed were constructed in substantial compliance with the plans and specifications.
Nutting
1130 Engineers
of Florida Inca Established 1967 2
ki
S
We note that it was monitored and ensured that the piles began installation at the survey locations
provided in the field. If during drilling operations it was discovered that gross deviations from
original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers
is not responsible for minor deviations which have occurred during drilling operations, along
with incorrect surveyed pile locations during piling installation.
Our client for this project was:
Mr. Rich Barnes
Bodax Foundations, Inc.
1101 NW 551h Street
Ft. Lauderdale, Florida 33309
The contents of this report are for the exclusive use of the client, the client's design &
construction team and governmental authorities for this specific project exclusively. Information
conveyed in this report shall not be used or relied upon by other parties or for other projects
without the expressed written consent of NE.
We appreciate this opportunity to work with you on this project and look forward to completing
this and future projects with you. Should you have any questions or if we can be of any further
assistance, please contact us at your convenience.
Respectfully Submitted,
NUTTING ENGINEERS OF FLORIDA, INC.
Richard C. Wohlfarth, E.
Director of Engineering
Attachments: Residence Pile Location Plan
Residence Pile Installation Data
Pool and Pool Deck Pile Location Plan
Pool and Pool Deck Pile Installation Data
LTR BODAX STEGER 8316 S-OCN HUTCHINSON RES AND POOL ACP CEG
Nutting
Engineers
of Florida Inch Established 1967
40�)
P.E. #69947
' rr.�+��oMran. �GAt(�z Pr oErel�m a�an�e oeraa as
-3 I�f 1�lFl�li-m
11�IIIIII ®dlllllnll 11 II �� �
A I
G�� T
'�Aas f
K 9l
�p
FOUN�ATIONv�LAN
` P4
u» Pa
kwlT
Ri
I
aNvbvil lyr¢a ow n _��
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
-Kedotu.
kid
7-7
oretIG
11;0:�1411
UTP
R
VOU e�o
A
4rouj'-
1Z
1
48
16.0
27
37.7
110
51.7
1.37
08/30/12
2
52
16.0
27
37.7
ill
52.2
1.38
08/30/12
3
55
16.0
27
37.7
1 107
50.3
1 1.33
08/30/12
4
35
16.0
27
37.7
154
72.4
1.92
08/30/12
Redrill
5
43
16.0
27
37.7
147
69.1
1.83
08/30/12
Redrill
6
59
16.0
27
37.7
108
50.8
1.35
08/30/12
7
40
16.0
27
37.7
104
48.9
1.30
08/30/12
8
46
16.0
27
37.7
103
48.4
1.28
08/30112
9
50
16.0
27
37.7
109
51.2
1.36
08/30/12
10
53
16.0
1 27
37.7
108
50.8
1.35
08/30/12
11
57
16.0
27
37.7
107
503
1.33
08130/12
12
33
16.0
2737.7
108
50.8
1.35
08/30/12
1
13
41
16.0
27
1 37.7
110
51.7
1.37
08/30/12
14
87
16.0
27
37.7
108
50.8
1.35
08/31/12
1
15
79
16.0
27
37.7
109
51.2
1.36
08/31/12
16
91
16.0
27
37.7
112
52.6
1.40
08/31/12
17
83
16.0
27
37.7
ill
52.2
1.38
08/31/12
18
96
16.0
27
37.7
106
49.8
1.32
08/31/12
19
44
16.0
27
37.7
112
52.6
1.40
08/31/12
20
45
16.0
27
37.7
113
53.1
1.41
08/31/12
21
49
16.0
27
1 37.7
ill 1
52.2
1.38
08131/12
22
56
16.0
27
37.7
108
50.8
1.35
08/31/12 1
23
60
16.0
27
37.7
109
51.2
1.36
08/31/12
24
89
16.0
27
37.7
104
48.9
1.30
08/31112
25
81
16.0
27
37.7
109
51.2
1.36
08/31/12
26
93
16.0
27
37.7
108
60.8
1.35
08/31/12
27
94
16.0
27
37.7
110
51.7
1.37
08/31/12
28 1
85
16.0
27
37.7
145
68.2
1.81
08/31/12
Redrill
29
34
16.0
27
37.7
106 1
49.8
1.32
08/31/12
30
47
16.0
27
37.7
118
55.5
1.47
08/31/12
31
51
16.0
27
37.7
110
51.7
1.37
08131/12
32
54
16.0
27
37.7
120
56.4
1.50
08/31/12
33
58
16.0
27
37.7
107
50.3
1.33
08131112
34
42
16.0
27
37.7
109
51.2
1.36
08/31/12
35
36
16.0
27
37.7
176
82.7
2.19
08131/12
Redrill
36
37
16.0
27
37.7
112
52.6
1.40
08/31/12
37
99
16.0
27
37.7
118
55.5
1.47
08/31/12
38
90
16.0
27
37.7
119
55.9
112
08I31/12
39
82
16.0
27 1
37.7 1
116
54.5
145 1
5 F/3'/12
40
86
16.0
27 1
37.7 1
115
54.1
1.43 1
08/31/12
IleNutting
Engineers
of Florida Inc. I Established 1967
*4 �)
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
PI
Ptfe,
Pile
PQ
„-Remarks ;
41
78
16.0
27
37.7
162
76.1
2.02
08/31/12
42
104
16.0
27
37.7
105
49.4
1.31
08/31/12
43
95
16.0
27
37.7
114
53.6
1.42
08/31/12
44
98
16.0
27
37.7
105
49.4
1.31
08/31/12
45
84
16.0
27
37.7
125
58.8
1.56
08/31/12
46
92
16.0
27
37.7
185
87.0
2.31
08131/12
RedrilF
47
88
16.0
27
37.7
107
50.3
1.33
08/31/12
48
80
16.0
27
37.7
103
48.4
1.28
08/31/12
49
101
16.0
27
37.7
118
55.6
1.47
09/04/12
50
103
16.0
27
37.7
113
53.1
1.41
09/04/12
51
70
16.0
27
37.7
115
54.1
1.43
09/04/12
52
66
16.0
27
37.7
ill
52.2
1.38
09/04/12
53
62
16.0
27
37.7
112
52.6
1.40
09104/12
54
39
16.0
27
37.7
109
51.2
1.36
09/04/12
55
97
16.0
27
37.7
107
50.3
1.33
09/04/12
56
100
16.0
27
37.7
1 116
54.5
1 1.45
09/04/12
1
57
105
16.0
27
37.7
106
49.8
1.32
09/04112
58
72
16.0
27
37.7
104
48.9
1.30
09/04/12
69
68
16.0
27
37.7
ill
52.2
1.38
09/04/12
60
64
16.0
27
37.7
107
50.3
1.33
09/04/12
61
38
16.0
27
37.7
104
48.9
1.30
09/04/12
62
107
16.0
27
37.7
105
49.4
1.31
09/04/12
63
110
16.0
27
37.7
113
53.1
1.41
09/04/12
64
131
16.0
27
37.7 1
ill
52.2 1
1.38
09/04/12
65
102
16.0
27
37.7
121
56.9
1.51
09/04/12
66
69
16.0
27
37.7
107
50.3
1.33
09/04/12
67
67
16.0
27
37.7
114
53.6
1.42
09/04/12
68
63
16.0
27
37.7
164
77.1
2.04
09/04/12
Redrill
69
71
16.0
27
37.7
106
49.8
1.32
09/04112
70 1
65
16.0 1
27
37.7
107
50.3
1.33
09/04/12
71
61
16.0
27
37.7
108
50.8
1.35
09/05/12
72
77
16.0
27
37.7
115
54.1 1
1.43
09/05/12
73
ill
16.0
27
37.7
112
52.6
1.40
09/05/12
74
113
16.0
27
37.7
106
49.8
1.-32-
09/05/12
75
30
16.0
27
37.7
105
49.4
1.31
09/05/12
76
8
16.0
27
37.7
103
48.4
1.28
09/05/12
77
9
16.0
27
37.7
108
50.8
1.35
09/05/12
78 1
13
16.027
37.7
110
51.7
1.37 1
09/05/12
79
17 1
i6�6
27
37.7
114
53.6
1.42
09/05/12
86
21 1
16.0
27 1
37.7 1
168 1
79.0 1
2.09
09105/12
-tN Nutting
iliaEngineers
of Florida Inc. 1 Established 1967
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
�s}d'.P!ke
t zt.'
s
71"hepittle.
wqlyme'�'
"iyl
RA,
81
28
16.0
27
37.7
111
52.2
1.38
09/05/12
82
106
16.0
27
37.7
107
50.3
1.33
09/05/12
83
112
16.0
27
37.7
108
50.8
1.35
09/05/12
84
6
16.0
27
37.7
116
54.5
1.45
09/05/12
85
133
16.0
27
37.7
156
73.3
1.94
09/05/12
Redrill
86
108
16.0
27
37.7
106
49.8
1.32
09/05/12
87
109-
16.0
27
37.7
108
50.8
1.35
09/05/12
88
5
16.0
27
37.7
116
64.5
1.45
09/05/12
89
11
16.0
27
37.7
148
69.6
1.85
09/05/12
90
15
16.0
27
37.7
106
49.8
1.32
09/05/12
91
19
16.0
1 27
37.7
127
59.7
1.58
09/05/12
92
22
16.0
27
37.7
118
55.5
1.47
09/05/12
93
26
16.0
27
37.7
106
49.8
1.32
09/05/12
94
132
16.0
27
37.7
107
50.3
1.33
09/05/12
95
7
16.0
27
37.7
ill
52.2
1.38
09/05/12
96
10
16.0
27
37.7
109
51.2
1.36
09/05/12
97
16
16.0
27
37.7
110
61.7
1.37
09/05/12
98
20
16.0
27
37.7
160
75.2
1.99
09/05/12
Redrill
99
24
16.0
1 27
37.7
116
54.5
1.45
09/05/12
100
27
16.0
27
37.7
141
66.3
1.76
09/05/12
101
25
16.0
27
317
110
51.7
1.37
09/05/12
102
18
120
27
37�7 1
117
55.0
1.46
09/05/12
103
23
16�6
27 1
37.7 1
107
60.3
1.33
09/05/12
104
77-A
16.0
27
37.7
102
47.9
1.27
09/10/12
Relocated Pile
105
1
16.0
27
37.7
103
48.4
1.28
09/10/12
106
14
16.0
27
37.7
117
55.0
1.46
09/10/12
107
31
16.0
27
37.7
109
51.2
1.36
09/10/12
108
75
16.0
27
37.7
152
71.4
1.90
09/10/12
109 1
3
16.0
27
37.7
107
50.3
1.33
09/10/12
110
118
16.0
27
37.7
112
52.6
1.40
09110/12
ill
115
16.0
27
37.7 1
115
54.1
1.43
09/10/12
112
12
16.0
27
37.7
112
52.6
1.40
09/10/12
113
29
16.0
27
37.7
122
57.3
1.52
09110/12
114
73
16.0
27
37.7
106
49.8
1.32
09/10/12
115
122
16.0
27
37.7
ill
52.2
1.38
09/10/12
116
2
16.0
27
37.7
146
68.6
1.82
09/10/12
117
32
16.0
27
37.7
120
56.4
1.50
09/10/12
118
14-A
16.0
27 1
37.7
127
59.7
1.58
09/10/12
Relocated Pile
119
14
16�0
2737
7
112
52.6
1.40
09/10/12
120
4
1661
27
37�7
108
50.8
1.35
09/10/12
121
116
16.0 1
27
37.7
108
50.8
1.35
09/10/12
Nutting
rEngineers
3le of Florida Inc.1 Established 1967
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
.'ReCOM"',
r, No122
'Pile 10110.
File qla
-Vx
130
16.0
27
37.7
110
51.7
1.37
09110/12
123
76
16.0
27
37.7
108
50.8
1.35
09/10/12
jL 24
120
16.0
1 27
37.7
109
51.2
1.36
09/10/12
125
125
16.0
27
37.7
105
49.4
1.31
09111/12
126
127
16.0
27
37.7
126
59.2
1.57
09/11/12
127
128
16.0
27
37.7
107
50.3
1.33
09/11/12
128
117
16.0
27
37.7
112
52.6
1.40
09/11/12
129
121
16.0
27
37.7
106
49.8
1.32
09/11/12
130
114
16.0
27
37.7
113
53.1
1.41
09/11/12
131
124
16.0
27
37.7
114
53.6
1.42
09/11/12
132
129 1
16.0
27
37.7 1
106
49.8
1.32
09/11/12
133
1
16.0
27
37.7
107
50.3
1.33
29/11/12
i Y4
119
16.0
27
37.7
112
52.6
1.40
09/11712
135
123
16.0
27
37.7
113
53.1
1.41
09/11/12
Total linear feet drilled
3645
Total Grout (yd') 271
Minimum depth drilled
27
Maximum depth drilled
27
PILE LOG BODAX STEGER 8316 S-OCN HUTCHINSON ACP
)Nulling
Engineers
of Florida Inc.] Established 1967
4t�
?c �;:
[.z
i
BODAX FOUNDATIONS
STEGER RESIDENCE POOL AND DECK
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
"curer
MUM
r
1
5
14.0
27
28.9
90
42.3
1.47
08/29/12
2
3
14.0
27
28.9
108
50.8
1.76
08/29/12
Redrill
3
29
14.0
27
28.9
89
41.8
1.45
08/29/12
4
10
14.0
27
28.9
116
54.5
1.89
08/29/12
Redrill
5
14
14.0
27
28.9
90
42.3
1.47
08/29/12
6
8
14.0
27
28.9
90
42.3
1.47
08/29/12
7
2
14.0
27
28.9
102
47.9
1.66
08/29/12
8
1
14.0
27
28.9
106
49.8
1.73
08/29/12
9
7
14.0
27.
28.9
91
42.8
1.48
08/29/12
10
4
14.0
27
28.9
86
40.4
1.40
08/29/12
11
6
14.0
274
28.9
92
43.2
1 1.50
08/29112
12
21
14.0
27
28.9
87
40.9
1.42
08/29/12
13
17
14.0
27
28.9
141
66.3
2.30
08/29/12
Redrill
14
22
140
27
28.9
140
65.8
2.28
08/29/12
Redrill
15
23
1�0
27
28.9
87
40.9
1.42
08/29112
16
11
14.0
27
28.9
94
44.2
1.53
08130/12
17
9
14.0
27
28.9
188
88.4
3.06
08/30/12
Redrill X 3
18
30
14.0
27
28.9
98
46.1
1.60
08/30/12
19
25
14.0
27
28.9
95
44.7
1.55
08/30/12
20
24
14.0
27
28.9
130
61.1
2.12
08/30/12
Redrill
21
18
14.0
27
28.9
152
71.4
2.48
08/30/12
Redrill
22
15
14.0
27
28.9
91
42.8
1.48
08/30/12
23
16
14.0 1
27
28.9 1
84
39.5 1
1.37
08/30/12 1
24
13
14.0
27
28.9
104
48.9
1.69
08/30/12
25
12
14.0
27
28.9
90
42.3
1.47
08/30/12
26
28
14.0
27
28.9
101
47.5
1.64
08/30/12
27
20
14.0
27
28.9
93
43.7
1.61
08/30/12
28
26
14.0
27
28.9
86
40.4
1.40
08/30/12
29
19
14.0
27
28.9
91
42.8
1.48
08/30/12
30 1
27
14.0
27
28.9
91
42.8
8
11 442
"2
1/32.�/1122
31
31 1
14.0
27
L1291
7
109
Total linear feet drilled
837
TO Grout (78d) 5t
Minimum depth drilled
27
Maximum depth drilled
27
PILE LOG BODAX STEGER 8316 S-OCN HUTCHINSON pool ACP
Nulling
Engineers
of Florida Inc. I Established 1967
fr'
Ing
y ` m RI > yT �� `j y, ' I,i it y 1 e rs
of Florida Inc. I Established 1967
Your Project is Our Commitment
Y tG
September 13, 2012
Mr. Rich Barnes
Bodax Foundations, Inc.
1101 NW 55 h Street
Ft. Lauderdale, Florida 33309
1310 Neptune Drive
Boynton Beach, Florida 33426
561-736-4900
Toll Free: 877-NUTTING (688-8464)
Fax: 561-737-9975
Broward 954-941-8700
St. Lucie 772-408-1050
Miami -Dade 305-557-3083
www.nuttingengineers.com
S�gNN�
at
. CUcigcoU1741
Subject: Report of Augercast Pile Installation Monitoring
Steger Residence and Pool
8316 South Ocean Drive
Hutchinson Island, Port St. Lucie, Florida
Dear Mr. Barnes:
Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations
for the proposed residence at the subject site. Bodax Foundations, Inc. installed cast -in -place
augured piles for support of the proposed residence, pool, and pool deck.
Bodax Foundations, Inc. installed a total of 166, 16-inch diameter and 14-inch diameter
augercast piles for the project. The piles were installed from August 29, 2012 to September 11,
2012. The pile size, capacity, and depth recommendations were based upon a Geotechnical
Exploration prepared by A.M. Engineering and Testing for Phoenix Realty Homes, Inc. dated
December 14, 2010.
The pile installation characteristics of each pile are presented in the attached Pile Installation
Data. Identification of each pile location followed by the pile number is shown on the Pile
Location Plans attached. Each pile record in the attached summary tables shows the following
information:
i.
) F F I C E S
'aim Beach
Alami-Dade
,t. Lucie
■ RECORD NUMBER IN CHRONOLOGICAL ORDER
■ THE PILE NUMBER (AS FOUND ON ATTACHED PLANS)
■ THE DIAMETER OF THE PILE
■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP
■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE
■ THE NUMBER OF PUMP STROKES FOR THE PILE
■ THE ACTUAL VOLUME OF GROUT FOR THE PILE
■ THE GROUT FACTOR
■ THE DATE OF INSTALLATION
1
■ THE REINFORCEMENT TYPES
■ AND GENERAL COMMENTS AS NEEDED
The drilling operations were monitored in the field by our field engineer and inspector in order to
approximately determine the type of material being penetrated. This identification was done
based on the augering time, the materials received during the drilling operations and the relative
hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines.
We note that separate pile plans and separate pile numbers were provided in the attachment
section of this report for the main residence differing from the pool and pool deck.
The main residence piles consisted of a total of 133, 16-inch diameter augercast piles. Due to
improper layout of pile number 14 and 77, two additional piles were installed at the corrected
layout location. Because of this 135 piles were recorded for the main residence. The main
residence piles were designed for an allowable compressive capacity of 30 tons. The piles were
installed for the specified capacity as required by the structural specifications.
The pool and pool deck piles consisted of a total of 31, 14-inch diameter augercast piles. The
pool deck piles were designed for an allowable compressive capacity of 5 tons, while the pool
piles were designed for an allowable compressive capacity of 15 tons. The piles were installed
for the specified capacity as required by the structural specifications. We note that as indicated
on the structural plans, the nine pool piles were installed at an approximate 15-degree batter
angle. The pile was placed at the survey elevation and battered at that location as well.
All piles for the residence, pool and pool deck were installed to a depth of twenty-seven feet
below the existing ground surface which was at an approximate elevation of +9 NGVD. The
piles were installed at existing ground surface elevations. Generally, during the installation of
the piles, easy drilling was observed from the ground level to approximately ten to fifteen feet.
Below ten to fifteen feet medium drilling conditions was encountered for the remaining depth of
the pile.
All house piles received a steel cage consisting of six (6) #6 reinforcing steel bars with #3 ties
spaced 10 inches from center to center the full length of the pile as stated in the structural
specifications. All pool and pool deck piles received a steel cage consisting of four (4) #5
reinforcing steel bars with #3 ties spaced 12 inches from center to center the full length of the
pile as stated in the structural specifications.
Upon completion of this inspection process, and review of the recorded data, it is our opinion
that the augercast piles for the main residence attained the required design compressive capacity
of 30 tons, the pool piles attained the required design compressive capacity of 15 tons, and the
pool deck piles attained the required design compressive capacity of 5 tons. The piles that were
presently installed were constructed in substantial compliance with the plans and specifications.
Nutting
11E Enginsegs
of Florida Inca Established 1967 2
We note that it was monitored and ensured that the piles began installation at the survey locations
provided in the field. If during drilling operations it was discovered that gross deviations from
original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers
is not responsible for minor deviations which have occurred during drilling operations, along
with incorrect surveyed pile locations during piling installation.
Our client for this project was:
Mr. Rich Barnes
Bodax Foundations, Inc.
1101 NW 55s' Street
Ft. Lauderdale, Florida 33309
The contents of this report are for the exclusive use of the client, the client's design &
construction team and governmental authorities for this specific project exclusively. Information
conveyed in this report shall not be used or relied upon by other parties or for other projects
without the expressed written consent of NE.
We appreciate this opportunity to work with you on this project and look forward to completing
this and future projects with you. Should you have any questions or if we can be of any further
assistance, please contact us at your convenience.
Respectfully Submitted,
NUTTING ENGINEERS OF FLORIDA, INC.
Richard C. Wohlfarth, E.
Director of Engineering
Attachments: Residence Pile Location Plan
Residence Pile Installation Data
Pool and Pool Deck Pile Location Plan
Pool and Pool Deck Pile Installation Data
LTR BODAX STEGER 8316 S-OCN HUTCHINSON RES AND POOL ACP CEG
Nutting
r3le Engineers
of Florida Inch Established 1967
P.E. #69947
S1
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
'"u uld�!
k Q
T
I I ,
I -
I g- of
-," �4�
F
-�4%
'Iftfilid W,
- -1,
- --fi
�sl ma z-13
1
48
16.0
27
37.7
110
51.7
1.37
08130/12
2
52
16.0
27
37.7
Ill
52.2
1.38
08/30/12
3
55
16.0
1 27
37.7
107
50.3
1 1.33
08/30/12
1
4
35
16.0
27
37.7
154
72.4
1.92
08/30/12
Redrill
5
43
16.0
27
37.7
147
69.1
1.83
08/30/12
Redrill
6
59
16.0
27
37.7
108
50.8
1.35
08/30/12
7
40
16.0
27
37.7
104
48.9
1.30
08/30/12
8
46
16.0
27
37.7
103
48.4
1.28
08/30/12
9
50
16.0
27
37.7
109
51.2
1.36
08130/12
10
53
16.0
27
37.7
108
50.8
1.35
1 08/30/12
11
57
16.0
27
37.7
101
50.3
3
153
1.33
130/1
12
33
16.0
27
37.7
168
56g
1.35
5
08/30/12
13
41
16.0
1 27
37.7
110
51.7
1.37
08/30/12
14
87
16.0
27
37.7
108
50.8
1.35
08/31/12
15
79
16.0
27
37.7
109
51.2
1.36
08/31/12
16
91
16.0
27
37.7
112
62.6
1.40
08/31/12
17
83
16.0
27
37.7
ill
52.2
1.38
08/31/12
18
96
16.0
27
37.7
106
49.8
1.32
08/31/12
19
44
16.0
27
37.7
112
52.6
1.40
08/31/12
20
45
16.0
27
37.7
113
53.1
1.41
08/31/12
21 1
49 1
16.0
27
37.7 1
111
52.2 1
1.38
'08/31/12
22
56
16.0
27
377
108
50.8
1.35
08/31/12
23
60
16.0
27
37.7
109
51.2
1.36
08/31/12
24
89
16.0
27
37.7
104
48.9
1.30
08/31/12
25
81
16.0
27
37.7
109
51.2
1.36
08/31/12
26
93
16.0
27
37.7
108
50.8
1.35
08/31/12
27
94
16.0
27
37.7
110
51.7
1.37
08/31/12
28
85
16.0
27
37.7
145
68.2
1.81
08/31/12
Redrill
29
34
16.0
27
37.7
106
49.8 1
1.32
08/31/12
30
47
16.0
27
37.7
118
55.5
1.47
08/31/12
31
51
16.0
27
37.7
110
51.7
1.37
08/31/12
32
54
16.0
27
37.7
120
56.4
1.50
08/31/12
33
58
16.0
27
37.7
107
50.3
1.33
08/31/12
34
42
16.0
27
37.7
109
51.2
1.36
08/31/12
36
36
16.0 1
27
37.7
176
82.7
2.19
08/31/12
Redrill
36
37
16.0
1
427
37.7
112
52.6
1.40
08/31/12
37
99
16.0
27
37.7
118
55.5
1.47
08131/12
38
90
16.0
g16.
27
E2
37.7
119
55 2
1
0�/31/12
39
82
0
7
37.7
ilg 1
� �4 5
1.45 1
F _
"3112
40
86
16.0
27
377
115 1
54.1
1.43
08/31/12
EJ
T31Nutting
Engineerls
of Florida Inc.] Established 1967
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
Record",Pile
Ala
Pife
Plle
Pump
Volume of
a rout
4178
16.0
27
37.7
162
76.1
2.02
08/31/12
42
104
16.0
27
37.7
105
49.4
1.31
08131/12
43
95
16.0
27
37.7
114
53.6
1.42
08/31/12
44
98
16.0
27
37.7
106
49.4
1.31
08131/12
45
84
16.0
27
37.7
125
68.8
1.56
08131/12
46
92
16.0
27
j27
37.7
L37.7
185
87.0
2.31
08/31/12
Redrill
47
88
16.0
27
37j.7
107
50.3
1.33
08/31/12
48
80
16.0
103
48.4
1.28
08/31/12
49
101
16.0
27
37.7
118
55.5
1.47
09/04/12
50
103
16.0
27
37.7
113
53.1
1.41
09/04/12
51
70
16.0
27
37.7
115
54.1
1.43
09/04/12
52
66
16.0
27
37.7
ill
52.2
1.38
09/04/12
53
62
16.0
27
37.7
112
52.6
1.40
09/04/12
54
39
16.0
27
37.7
109
51.2
1.36
09/04/12
55
97
16.0
27
37.7
107
50.3
1.33
09/04/12
56
100
16.0
1 27
37.7
1 116
54.5
1.45
09/04/12
1
57
105
16.0
27
37.7
106
49.8
1.32
09/04/12
58
72
16.0
27
37.7
104
48.9
1.30
09/04/12
59
68
16.0
27
37.7
ill
52.2
1.38
09/04/12
60
64
16.0
27
37.7
107
50.3
1.33
09/04/12
61
38
16.0
27
37.7
104
48.9
1.30
09/04/12
62
107
16.0
27
37.7
105
49.4
1.31
09/04/12
63
110
16.0
27 1
37.7
113
53.1
1.41
09/04/12
64
131
16.0
27
37.7
ill
52.2
1.38
09/04/12 1
65
102
16.0
27
37.7
121
56.9
1.51
09/04/12
66
69
16.0
27
37.7
107
50.3
1.33
09/04/12
67
67
16.0
27
37.7
114
31
1.42
09104/12
68
63
16.0
27
37.7
164
771
2.04
09104/12
Redrill
69
71
16.0
27
37.7
106
49.8
1.32
09/04/12
70 1
65
16.0 1
27
37.7
107
50.3
1.33
09/04/12
71
61
16.0
27
37.7
108
50.8
1.35
09/05/12
72
77
16.0
27
37.7
115
54.1
1.43
09/05/12
73
ill
16.0
27
37.7
112
52.6
1.40
09/05112
74
113
16.0
27
37.7
106
49.8
1.32
09/05/12
75
30
16.0
27
37.7
105
49.4
1.31
09/05/12
76
8
16.0
27
37.7
103
48.4
1.28
09/05/12
77
9
16.0
27
37.7
108
50.8
1.35
09/05/12
78 1
13
16.0
2
37�
1 1
551:�7
1
19//.Og57/ 12
79 1
i� 1
i�!6 1
�7
57 7 1
�O
'i
2
1.42
��3
1
6 12
80 1
21
16.0 1
27
37.7 1
168
79.0
2.09
09/05/12
Honing
Balmeamrs
of Florida Inc. 1 Established 1967
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
"M
81
28
16.0
27
37.7
Ill
62.2
1.38
09/05/12
82
106
16.0
27
37.7
107
50.3
1.33
09/05/12
83
112
16.0
27
37.7
108
50.8
1.35
09/05/12
84
6
16.0
27
37.7
116
54.5
1.45
09105/12
85
133
16.0
27
37.7
156
73.3
1.94
09/05/12
Redrill
86
108
16.0
27
37.7
106
49.8
1.32
09/05/12
87
109
16.0
27
37.7
108
50.8
1.35
09/05/12
88
5
16.0
27
37.7
116
54.5
1.45
09/05/12
89
11
16.0
27
37.7
148
69.6
1.85
09/05/12
90
15
16.0
27
37.7
106
49.8
1.32
09105/12
91
19
16.0
27
37.7
127
69.7
1.58
09/05/12
92
22
16.0
27
37.7
118
55.5
1 1.47
09/06/12
1
93
26
16.0
27
37.7
106
49.8
1.32
09/05/12
94
132
16.0
27
37.7
107
50.3
1.33
09105/12
95
7
16.0
27
37.7
ill
52.2
1.38
09/05112
96
10
16.0
27
37.7
109
51.2
1.36
09/05/12
97
16
16.0
27
37.7
110
51.7
1.37
09/05/12
98
20
16.0
27
37.7
160
75.2
1.99
09/05/12
Redrill
99
24
16.10
1 27
37.7
116
54.5
1.45
09/05112
100
1 27
16.0
27
37.7
141 1
66.3 1
1.76 A
09/05/12
1
101
25
16.0
27
37.7
Ill
51�j
1.37
09/05/12,
102
18
16.0
9E
27
37.7
117
r ,g 0
09/05/12H
163
23
16.0
27
37.7
107
50.3 1
1.33
09/05/12
104
77-A
16.0
27
37.7
102
47.9
1.27
09/10/12
Relocated Pile
105
1
16.0
27
37.7
103
48.4
1.28
09/10/12
106
14
16.0
27
37.7
117
55.0
1.46
09/10/12
107
31
16.0
27
37.7
log
51.2
1.36
09/10/12
108
75
16.0
27
37.7
152
71.4
1.90
09110/12
109
3
16.0
27
37.7
107
50.3
1.33
09/10/12
110
118
16.0
27
37.7
112
52.6
1.40
09/10/12
ill
115
16.0
27
37.7
115
54.1
1.43
09/10/12
112
12
16.0
27
37.7
112
52.6
1.40
09/10/12
113
29
16.0
27
37.7
122
57.3
1.52
09/10/12
114
73
16.0
27
37.7
106
49.8
1.32
09/10/12
115
122
16.0
27
37.7
ill
52.2
1.38
09/10/12
116
2
16.0
27
37.7
146
68.6
1.82
09/10/12
117
32
16.0
27
37.7
120
56.4
1.50
09/10/12
118
14-A
16.0
27
37.7
127
59.7 1
1.58 1
09/10/12
Relocated Pile
119
74
16�50
27
37.7
111
52.6
1.40
09/10/12
120
4
1
27
57J
158
50.8
1.35
09110112
121
116
16.0
27
37.7
108
50.8
1.35
09/10/12
TICAL 416, Nulling
) Engineers
of Florida Inc. I Established 1967
BODAX FOUNDATIONS
STEGER RESIDENCE
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
0.,In
Volume
gn
;1M
ke
t Iro S"'�
a
V61""'
Pumped,'!
4, Factor
Installed
1A '9
Remarks
130
16.0
27
37.7
110
51.7
1.37
09/10112
E122
123
76
16.0
27
37.7
108
50.8
1.35
09110/12
124Y]
120
16.0
27
37.7
1 109
51.2
1 1.36
1 09/10/12
126
125
16.0
27
37.7
105
49.4
1.31
09/11/12
126
127
16.0
27
37.7
126
59.2
1.57
09/11/12
127
128
16.0
27
37.7
107
50.3
1.33
09/11/12
128
117
16.0
27
37.7
112
52.6
1.40
09/11/12
129
121
16.0
27
37.7
106
49.8
1.32
09/11/12
130
114
16.0
27
37.7
113
53.1
1.41
09/11112
131
124
16.0
27
37.7
114
53.6
1.42
09111/12
132
129
16.0
27
37.7 1
106 1
49.8 1
1.32 1
09/11/12
133
126
16.0
27
37.7
107
50.3
1.33
09/11/12
134
�
119
F_16.0
27
37.7
112
52.6
1.40
09/11/12
135
123 1
16.0
27
37.7
113
53.1
1.41
09/11/12
Total linear feet drilled
3645
Total Grout (ydj) 271
Minimum depth drilled
27
Maximum depth drilled
27
PILE LOG BODAX STEGER 8316 S-OCN HUTCHINSON ACP
T310Nulling
Engineers
of Florida Inc.1 Established 1967
1 y 1 Of Ot CrUI'AYf.
a�
BODAX FOUNDATIONS
STEGER RESIDENCE POOL AND DECK
AUGERCAST PILES
8316 South Ocean Drive
Hutchinson Island, Florida
PILE LOG DATA OF AUGERCAST PILE INSTALLATION
NUTTING ENGINEERS OF FLORIDA, INC.
-iRecord
Trisoretic.
V
1
5
14.0
27
28.9
90
42.3
1.47
08/29/12
2
3
14.0
27
28.9
108
50.8
1.76
08/29/12
Redrill
3
29
1 14.0
27
28.9
89
41.8
1.45
08/29/12
4
10
14.0
27
28.9
116
54.5
1.89
08/29/12
Redrill
5
14
14.0
27
28.9
90
42.3
1.47
08/29/12
6
8
14.0
27
28.9
90
42.3
1.47
08/29/12
7
2
14.0
27
28.9
102
47.9
1.66
08129/12
8
1
14.0
27
28.9
106
49.8
1.73
08/29/12
9
7
14.0
27
28.9
91
42.8
1.48
08/29/12
10
4
14.0
27
28.9
86
40.4
1.40
08/29/12
11
6
14.0
27
28.9
92
43.2
1.50
08129112
12
21
14.0
27
28.9
87
40.9
1.42
08129112
13
17
14.0
27
28.9
141
66.3
2.30
08/29/12
Redrill
14
22
14.0
27
28.9
140
65.8
2.28
08/29/12
Redrill
15
23
14.0
27
28.9
87
40.9
1.42
08/29/12 1
16
11
14.0
27
28.9
94
44.2
1.53
08/30/12
17
9
14.0
27
28.9
188
88.4
3.06
08/30/12
Redrill X 3
18
30
14.0
27
28.9
98
46.1
1.60
08/30/12
19
25
14.0
27
28.9
95
44.7
1.55
08130/12
20
24
14.0
27
28.9
130
61.1
2.12
08/30112
Redrill
21
18
14.0
27
28.9
152
71.4
2.48
08/30/12
Redrill
22
15
14.0
27
28.9
91
42.8
1.48
08130/12
23
16 1
14.0
27 1
28.9
84
39.5
1.37
08/30/12
24
13
14.0
27
28.9
104
48.9
1.69
08/30/12
25
12
14.0
27
28.9
90
42.3
1.47
08/30112
26
28
14.0
27
28.9
101
47.5
1.64
08/30/12
27
20
14.0
27
28.9
93
43.7
1.51
08/30/12
28
26
14.0
27
28.9
86
40.4
1.40
08/30/12
29
19
14.0
27
28.9
91
42.8
1.48
08130/12
30 1
27
14.0 1
27
28.9 1
91
428
1.48
08/30/12
31 1
31 1
14.0
27 1
28.9 1
87
TO
� 9
1.42
00/30/12
Total linear feet drilled
837
Total Grout (ydj) 56
Minimum depth drilled
27
Maximum depth drilled
27
PILE LOG BODAX STEGER 8316 S-OCN HUTCHINSON pool ACP
Nutting
waft
Mineola