Loading...
HomeMy WebLinkAboutREVIEW COMMENTSL�,, 0 SZ''Ll . Planning & Development services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 4624553 Fax: (772) 4624578 01/16/2013 22852 PHOENIX REALTY HOMES INC TARPELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 Permit Number: 1203-0259 Review Comments for Contractor SCANNED BY St. Lucie County Page 1 As of today's date the owner listed on your application is being notified along with yourself that the referenced building permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION 8316 OCEAN DR JENSEN BEACH 34957 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) REVIEWS AND COMMENTS Review Type Status Addressing Assignment Complete Documents. Missing Complete OWNERS INFORMATION SAM T. STEGER 3201 SW WINDING WAY PALM CITY, FL 34990 Application Type: Master Permit w/subs OtherActivity: Stories 3 Reviewed By Date Started Date Complete Data Released Lydia Galbraith 0410312012 Dawn Milone 03/14/2012 07/1212012 Review Comments for Planning & Development Services Contractor Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Page 2 Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Front Counter Review Complete Dawn Milone 03/1412012 03/1512012 Notified for Pickup Complete Dawn Milone 12/1312012 Plans Examiner Review Complete Dave Johnson 04/30/2012 0711212012 Revisions Incomplete Dave Johnson 12/1912012 01/16/20132 Comment THERE ARE MULTIPLE REVISIONS TO THESE PLANS, AND WILL REQUIRE A$50 REVISION FEE PER CHANGE 01/16/20133 Comment PROVIDE REVISED ENERGY CALC'S AND MANUAL J CALC'S WITH NEW AC LAYOUT IN DUPLICATE. NEW PLANS SHOW 4AC UNITS, ORIGINAL PLANS SHOW 5 AC UNITS W? To Be Reviewed by Zoning Complete 03130/2012 To Be Review by Plans Exan Complete 0413012012 Zoning Review Complete Lydia Galbraith 03/3012012 07/0312012 , �etC4K 61;1 v7 uw2 Planning & Development Services Building &,Code Regulation Division 2300 Virginia Avenue 'Fort Pierce, FL. 34982 Phone:17721462.2172 Fax:t7721462.6443 May 14, 2013 22852 PHOENIX REALTY HOMES INC ALAN J TARPELL 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 REVIEW COMMENTS FOR CONTRACTOR Page 1 of 2 RE: Building Permit Number 1203-0259 As of today's date the owner listed on your application is being notified along with yourself that the referenced buiding permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION OWNER INFORMATION 8316 S OCEAN DR SAM T STEGER JENSEN BEACH, FI. 34957 3201 SW WINDING WAY PALM CITY, FL 34990 APPLICATION INFORMATION Permit Number: 1203-0259 Stories: Permit Type: Building Residential (SFR) REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released Front Counter Review Complete Dawn Milone 3/14/2012 3/15/2012 Comment: Documents Missing Complete Dawn Milone 3/14/2012 7/12/2012 Comment: To be reviewed by Zoning Complete 3/30/2012 3/14/2012 Comment: Zoning Review Complete Lydia Galbraith 3/30/2012 7/3/2012 Comment: Addressing Assignment Complete Lydia Galbraith 4/3/2012 4/2/2012 Comment: Tuesday, May 14, 2013 9:58 AM ja �irozr. �ioun�r� Planning& Development Services Building 8 Code Regulation Division 2300 Virginla Avenue Fort Pierce, FL 34982 Phone:(772(462.2172 Fax:(772)462.6443 To be reviewed by Plans Complete Examiner Comment: Plans Examiner Review Complete Comment: Notified for Pickup - Revisions Complete Comment: Revisions Incomplete 1/16/2013 12:00:00 AM Comment: 5/14/2013 9:48:44 AM Comment 5/14/2013 9:53:13 AM Comment Revisions Complete Comment: Notified for Pick Up Complete Comment: Revisions Pending Comment: REVIEW COMMENTS FOR CONTRACTOR Page 2 of 2 4/30/2012 4/3/2012 Dave Johnson 4/30/2012 7/12/2012 Dawn Milone 12113/2012 Dave Johnson 12/19/2012 PROVIDE REVISED ENERGY CALC'S AND MANUAL J CALC'S WITH NEW AC LAYOUT IN DUPLICATE. NEW PLANS SHOW 4 AC UNITS, ORIGINAL PLANS SHOW 5 AC UNITS ???'"'"5/13/13 NEW AC LAYOUT SHOWS AC COMPRESSOR AT GROUND LEVEL. ALL EQUIPMENT MUST BE ELEVATED ABOVE DESIGN FLOOD ELEVATION. SEE R322.1.6, R322.1.4 REVISION TO ADD BATHROOM ON GROUND FLOOR IS NOT PERMITED. PLUMBING FIXTURES, DUCT SYSTEMS ARE NOT PERMITTED BELOW DESIGN FLOOD ELEVATION R322.1.6 BUILDING MATERIALS USED BELOW DESIGN FLOOD ELEVATION ARE REQUIRED TO BE OF FLOOD RESISTANT MATERIALS R322.1:8 Dave Johnson 12/19/2012 1/16/2013 Dawn Milone Dawn Milone 5/8/2013 1/16/2013 5/7/2013 Tuesday, May 14, 2013 9:58 AM . Review Comments for Planning S, Development Services Contractor Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Page 1 Fort Pierce, FL 34982 Phone:(772) 4624553 Fax:(772) 4624578 12/19/2012 22852 PHOENIX REALTY HOMES INC TARPELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH. FL 33411 Permit Number: 1203-0259 As of today's date the owner listed on your application is being notified along with yourself that the referenced building permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION 8316 OCEAN JENSEN BEACH 34957 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) REVIEWS AND COMMENTS Review Type status Addressing Assignment Complete Documents Missing Complete Front Counter Review Complete Notified for Pickup Complete OWNERS INFORMATION DR SAM T. STEGER 3201 SW WINDING WAY PALM CITY, FL 34990 Application Type: Master Permit w/subs Other Activity: Stones 3 Reviewed By Data Started Date Complete Date Released Lydia Galbraith 0410312012 Dawn Milone 0311412012 07/1212012 Dawn Milone 03114/2012 0311612012 1211312012 Dawn Milone .41 I 0 Review Comments for Planning & Development Services Contractor Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Page 2 Fort Pierce, FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 lans Examiner Review Complete Dave Johnson 04/30/2012 07/1212012 Revisions Incomplete Dave Johnson 12119/2012 12/19/20121 Comment CONTRACTOR MUST PROVIDE COVER LETTER LISTING THE CHANGES TO PLANS. FACH REVISION REQUIRES A$50 REVISION FEE. To Be Reviewed by Zoning Complete 03/30/2012 To Be Review by -Plans Exan Complete Zoning Review Complete Lydia Galbraith 04/3012012 03130/2012 07103/2012 Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 4624553 Fax: (772) 462-1578 06/15/2012 SCANNED BY St. Lucie County 22852 PHOENIX REALTY HOMES INC TARPELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 Permit Number: 1203-0259 Review Comments for Contractor FEmolcv) 611rll2 As of today's date the owner listed on your application is being notified along with building permit has some issues listed in the comments below. Page 1 Please address these issues as quickly as possible so.that we are able to continue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION 8316 OCEAN JENSENBEACH 34957 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) REVIEWS AND COMMENTS Review Type Status Addressing Assignment Complete Documents Missing Pending OWNERS INFORMATION DR SAM T. STEGER 3201 SW WINDING WAY PALM CITY, FL 34990 Application Type: Master Permit w/subs Other Activity: Stones 3 Reviewed By Date Started Date Complete Date Released Lydia Galbraith 0410312012 Dawn Milone 03/14/2012 03/15120121 Comment PLEASE PROVIDE RECORDED NOC AT TIME OF PICKUP 03/15120122 Comment PLEASE PROVIDE FILLED LANDS AFFIDAVIT AT TIME OF PICKUP 6/1/12 SUBMITTED FILLED LANDS AFFIDAVIT IS A COPY, PLEASE SUBMIT THE ORIGINAL AT TIME OF PICKUP. urriG �ior�?z Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 4624553 Fax: (772) 462-1578 Review Comments for Contractor Page 2 03/15/20124 Comment PLEASE PROVIDE SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, M ECHAN [CAL AND ROOF ASUB SUMMARY SHEET. 6/25/12 WE ARE STILL MISSING A ROOF SUB AGREEMENT AND GAS SUB AGREEMENT -ALL OTHERS WERE SUBMITTED 03/15/201210 Comment VEG PERMIT PUT IN BIN 4-04-2012 VEG PERMIT IN DRAWER UNDER (S) FOR STEGER FEESARE LOADED IN COMPUTER SYSTEM: A HUMPHREY 06/011201214 Comment THE MECHANICAL SUBCONTRACTOR IS ON HOLD. HIS LIABILITY INS. HAS EXPIRED AND HIS W/C WILL EXPIRE 6/28112. Front Counter Review Complete Dawn Milone 0311412012 03/1612012 Plans Examiner Review Pending Dave Johnson 04/30/2012 05101/20122 Comment PROVIDE FL PRODUCT APPROVAL FOR ALL EXTERIOR DOORS AND WINDOWS 613 FBC 6116/12: MISSING PRODUCT APPROVAL FOR EXTERIOR FRENCH DOORS & SLIDING GLASS DOORS 1)1I 112 ,$'TILL NU NOR fGL. $'(rQ /prrok E+�0 a fp 47 foa PrrE� u.re.0� 05102120126 Comm STRUCTUAL DRAWINGS FOR ALUMINUM RAILING ARE OUT OF DATEAND NOT VALID WITHOUTAN ORIGINAL SIGNITUREAND RAISED SEAL 106.1.1 06/151201211 Comment f STRUCTURAL FOUNDATION PLAN NOTES GARAGE FLOOR AT 8.83 NGVD. SURVEY SHOWS G AGE FLOOR AT 9.5 NGVD. ARCHITECTUAL PLANS PAGES 101,301,302,401,& 801 NOTE GARAGE AT NGVD. ALL PLANS SHOULD MATCH WITH EACH OTHER. FBC 106.1.1 06/151201212 Comment OUNDATION PLAN LAYOUT DESIGNATES PC 3 FRONT OF HOME BY STAIRS. PC 3 DETAIL DOES NOT MATCH WHATS ON LAYOUT. SAME FOR PC 2 PILE CAPS. PLEASE CHECKAND CORRECTAS NEEDED. 06115/201213 Commenti/ PROVIDE GRADE BEAM DETAILS 06115/201214 Comment PROVIDE MANUFACTURERS SPEC'S WITH INSTALATION INSTRUCTIONS FOR FIRE PLACES REVIEWEDAND SIGNED BY DESIGN PROFRESSIONAL OF RECORD IN DUPLICATE p 97 AooQE_fIrXV pIWX,(6,4 061151201215 Commend NOTE ON PLANS CEILING DETAILS FORALL EXTERIOR PORCHES, BALCONY'S ECT. 06/15/201216 Comment (/PROVIDE NEW PAGE E 104. PAGE SUBMITTED IS NOT LEGIBLE (TO SMALL TO READ). O6/15/201217 061151201218 Comment V/TE ON PLANS DRYER VENT TERMINATION Comment/NOTE ON PLANS BATHROOM EXHAUST VENT TERMINATIONS 06/151201219 Comment VSHOW ATTIC ACCESS ON PLANS 06/15/201220 Comment PROVIDE SHOP DRAWINGS FOR EPICORE FLOOR SYSTEM REVIEWED AND SIGNED BY DESIGN PROFFESSIONAL OF RECORD. INCLUDE SHORING DETAILS A& fp-C1FdA) sr Review Comments for Planning & Development Services Contractor Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Page 3 Fort Pierce, FL 34982 Phone: (772) 462.1553 Fax: (772) 462.1578 0611512012 21 Comment NOTE ON PLANS DOORS SEPERATING LOBBY FROM GARAGE ARE SOLID CORE WOOD OR 20 N FIRE RATED 06/15/2012 22 omment NOTE ON PLANS GARAGE FLOOR IS SLOPED TOWARD MAIN VEHICLE DOOR 06/15/2012 23 r/Comment STRUCTUAL PLANS NOTE 5000 PSI FOR ALL CONCRETE. ARCHITECTUAL PLANS NOTE 2500 PSI FOR CONCRETE AND 3000 PSI FOR MASONRY GROUT. 06/151201224 i/Comment SHOW LOCATION OF ELECTRICAL PANEL ON PLANS O6/15/201225 �mment SHOW LOCATION OF WATER HEATER ON PLANS 06/15/201226 Comment PROVIDE GAS RISER DIAGAM IN DUPLICATE Pf To Be Reviewed by Zoning Complete 0313012012 To Be Review by Plans Exan Pending Zoning Review Incomplete 0313012012 Lydia Galbraith 03130/20121 Comment PLEASE PROVIDEA COPY OF THE COMPLETE FDEP PERMIT. 611/12 RECEIVED NOTICE TO PROCEED, PLEASE PROVIDE THE COMPLETE FDEP PERMIT. 05117/20129 Comment ADD NOTES FOR MITIGATION IN INSPECTIONS FOR ERD. 06/01/201210 Comment THE SURVEY IS NOT MATCHING WITH THE FOUNDATION PLAN. DIMENSIONS ARE OFF. THE PROPOSED FINISHED FLOOR ELEVATION IS NOT MATCHING WITH THE BUILDING PLANS. THE FFE OF THE FIRST HABITABLE FLOOR CAN'T BE HIGHER THAN 20' CHIMNEY ON HIGHER FLOORS NEED TO SHOW ON SURVEYAS DOTTED LINESAND MAY NOT ENCROACH IN THE SETBACK. THE FRONT BALCONY NEED TO SHOW ON THE SURVEYAS WELLAND IS ALSO NOTALLOWED THE ENCROACH IN THE FRONT SETBACK. m15TfvC hc� fGduo /- DOS SClt�ov�ds '41 gal;S you ` n?ZJ4 1"He /(/d'e- R';RA- kcl�trFl?run /Jl(196,'- z -6411 ado , M19jJ& 13A02d`I^ rv"V"kA /U07 M'q 7CNiNL l Planning & Development Services Building& Code Regulation Division Review Comments Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Page 1 Phone: (772) 462-1553 Fax: (772) 462-1678 PROPERTY INFORMATION Owner(s): Address: 8316 OCEAN DR S SAM T STEGER City / State / Zip: JENSEN BEACH FL 34957 KAREN O STEGER Parcel # : 3527-501-0043-000/8 Jurisdiction: St. Lucie County Zoning: HIRD Lot#: 42 Block: SCANNED APPLICATION INFORMATION StBY . Lucie County Permit Number: 1203-0259 Application Type: Master Permit wlsubs Activity Type: New Other Activity: Permit Type: Building Residential (SFR) Stories: 3 Automatic Sprinkler System? ❑ CONTRACTOR INFORMATION Contractor Name: TARPELL, ALAN J Business Name: PHOENIX REALTY HOMES INC Business Addr: 1760 N JOG RD SUITE 140 Fax Number 561-537-7226 City I State / Zil WEST PALM BEACH, FL 3' REVIEWS AND COMMENTS Review Tvpe Status Reviewed By Addressing Assignment Complete Lydia Galbraith Documents Missing Pending Date Started Date Complete Date Released 04/0312012 Dawn Milone 03/14/2012 03/15/2012 1 Comment PLEASE PROVIDE RECORDED NOC AT TIME OF PICK UP 03/15/2012 2 Comment PLEASE PROVIDE FILLED LANDS AFFIDAVITAT TIME OF PICKUP 6/1/12 SUBMITTED FILLED LANDS AFFIDAVIT ISACOPY, PLEASE SUBMIT THE ORIGINALAT TIME OF PICK UP. 03/15/2012 4 Comment PLEASE PROVIDE SUBAGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICALAND ROOF ANDA SUB SUMMARY SHEET. k 5/25112 WE ARE STILL MISSING A ROOF SUB AGREEMENT AND GAS SUB AGREEMENT -ALL OTHERS WERE SUBMITTED 03/15/2012 10 Comment VEG PERMIT PUT IN BIN 4-04-2012 VEG PERMIT IN DRAWER UNDER (S) FOR STEGER FEES ARE LOADED IN COMPUTER SYSTEM: AHUMPHREY 06/01/2012 13 Comment PLEASE PROVIDE COPY OF THE RECEIPT FOR PAID SEWERAT TIME OF PICK UP. * 06/01/2012 14 Comment THE MECHANICAL SUB CONTRACTOR IS ON HOLD. HIS LIABILITY INS. HAS EXPIRED AND HIS W/C WILL EXPIRE 6/28/12. Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Front Counter Review Complete i Review Comments Dawn Milone 03/14/2012 03/15/2012 Page 2 Plans Examiner Review Pending Dave Johnson 0413012012 05/O1/2012 1 Comment PROVIDE ENERGY CALC'S AND MANUAL J CALC'S IN DUPLICATE N1100 FBC 05/01/2012 2 Comment PROVIDE FL PRODUCTAPPROVAL FOR ALL EXTERIOR DOORS AND WINDOWS 613 FBC 05/01/2012 3 Comment SUBMIT STUCTURAL DRAWINGS IN DUPLICATE. PLEASE INDICATE PRIME PROFESSIONAL OF RECORD FOR THIS PROJECT. THE PRIME PROFESSIONAL OF RECORD MUST REVIEW & APPROVE ALL CONSTRUCTION DOCUMENTS IN WRITING. 106.3.5 05/02/2012 4 Commenl SUBMIT MECANICAL DRAWINGS IN DUPLICATE 106.1.1 05/02/2012 5 Comment SUBMIT TRUSS DRAWINGS REVIEWED AND SIGNED BY DESIGN PROFESSION OF RECORD IN DUPLICATE 106.1.1 05/02/2012 6 Comment STRUCTUAL DRAWINGS FORALUMINUM RAILING ARE OUT OF DATEAND NOT VALID WITHOUT AN ORIGINAL SIGNITUREAND RAISED SEAL 106.1.1 05/02/2012 7 Comment GENERAL NOTES SHOULD INCLUDE WEATHERING & TERMITE AREA [SEE TABLE 301(2)11, FLAME SPREAD & SMOKE DEVELOPED INDEX FOR WALL/CEILING FINISH [SEE R 3151 FLAME SPREAD SMOKE DEVELOPED INDEX & CRITICAL RADIANT FLUX FOR INSULATION [SEE R 316]. GYPSUM BOARD MATERIAL CONFORMS WITH R 702.3.1, AND CERAMIC TILE CONFORMS WITH R 702.4. 05/02/2012 8 Comment INCLUDE BASE FLOOD ELEVATION PER FEMA ON SURVEY. WILL USE WORST CASE FOR FLOOD PROOF CONSTRUCTION BELOW BFE R 323. 05/02/2012 9 Comment STOPPED REVIEW. A COMPLETE REVIEW CAN NOT BE DONE TILL ALL CONSTRUCION DRAWINGS ARE RECEIVED. 05/02/2012 10 Comment COMMENTS FAXED TO CONTRACTOR MAILED TO OWNER To Be Reviewed by Zoning Complete 03/30/2012 To Be Review by Plans Exar Pending Zoning Review Incomplete Lydia Galbraith 03/30/2012 03/30/2012 1 Comment PLEASE PROVIDE A COPY OF THE COMPLETE FDEP PERMIT. .y 6/1/12 RECEIVED NOTICE TO PROCEED, PLEASE PROVIDE THE COMPLETE FDEP PERMIT. 06/17/2012 9 Comment ADD NOTES FOR MITIGATION IN INSPECTIONS FOR ERD. 06/01/2012 10 Comment THE SURVEY IS NOT MATCHING WITH THE FOUNDATION PLAN. DIMENSIONSARE OFF. THE PROPOSED FINISHED FLOOR ELEVATION IS NOT MATCHING WITH THE BUILDING PLANS. THE FFE OF THE FIRST HABITABLE FLOOR CAN'T BE HIGHER THAN 20' CHIMNEY ON HIGHER FLOORS NEED TO SHOW ON SURVEY AS DOTTED LINES AND MAY NOT ENCROACH IN THE SETBACK. THE FRONT BALCONY NEED.TO SHOW ON THE SURVEYAS WELL AND IS ALSO NOTALLOWED THE ENCROACH IN THE FRONT SETBACK. ,5a—xo.r� 4 Planning & Development Services Building & Code Regulation Division Permitting Department 230D Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 4624553 Fax: (772) 462-1578 05/02/2012 22852 PHOENIX REALTY HOMES INC TARPELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 Permit Number: 1203-0259 Review Comments for Contractor Page 1 SCq S. 4UC/gcoU� ntY As of today's date the owner listed on your application is being notified along with yourself that the referenced building permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. -If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION 8316 OCEAN JENSEN BEACH 34957 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) REVIEWS AND COMMENTS Review Type Status Addressing Assignment Complete Documents Missing 03115/20121 03115/20122 03/15/2012 4 03/15/2012 6 03/15/2012 8 Pending OWNERS INFORMATION DR SAM T. STEGER 3201 SW WINDING WAY PALM CITY, FL 34990 Application Type: Master Permit w/subs OtherActivity: Stones 3 Reviewed By Data Started Date Complete Date Released Lydia Galbraith 0410312012 Dawn Milone 03114/2012 Comment PLEASE PROVIDE RECORDED NOCAT TIME OF PICKUP Comment PLEASE PROVIDE FILLED LANDS AFFIDAVIT AT TIME OF PICKUP Comment PLEASE PROVIDE SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICAL AND ROOF AND A SUB SUMMARY SHEET. Comment PLEASE PROVIDE 2 SIGNED SET OF MANUAL J'S AND ENERGY CALLS Comment PLEASE PROVIDE OWNERS PHONE # Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax:(772) 4624578 1n (:nmment VEG PERMIT PUT IN BIN Review Comments for Contractor Page 2 4-04-2012 VEG PERMIT IN DRAWER UNDER (S) FOR STEGER FEES ARE LOADED IN COMPUTER SYSTEM: AHUMPHREY 041021201211 Comment PLEASE PROVIDE A COPY OF THE PAID UTILITIES FOR WATER & SEWER AT TIME OFPICKUP. 041021201212 Comment PLEASE PROVIDE LETTER FROM THE POWER COMPANY THAT ELECTRIC WILL BE AVAILABLE FOR THIS PROPERTY. YOU CAN BRING IT IN AT TIME OF PICKUP. Front Counter Review Complete Dawn Milone 03114/2012 03/1512012 Plans Examiner Reviewer Pending Dave Johnson 0413012012 05/01120121 ✓Comment PROVIDE ENERGY CALC'S AND MANUAL J CALC'S IN DUPLICATE N1100 FBC 0510112012 2 Comment PROVIDE FL PRODUCT APPROVAL FOR ALL EXTERIOR DOORS AND WINDOWS 613 FBC 05/01/20123 I/Comment SUBMIT STUCTURAL DRAWINGS IN DUPLICATE. PLEASE INDICATE PRIME PROFESSIONAL OF RECORD FOR THIS PROJECT. THE PRIME PROFESSIONAL OF RECORD MUST REVIEW & APPROVE ALL CONSTRUCTION DOCUMENTS IN WRITING. 106.3.5 05/0220124 /omment SUBMIT MECANICAL DRAWINGS IN DUPLICATE 106.1.1 05102/20125 /Comment SUBMITTRUSS DRAWINGS REVIEWEDAND SIGNED BY DESIGN PROFESSION OF RECORD IN DUPLICATE 106.1.1 , 05102120126 Comment STRUCTUAL DRAWINGS FORALUMINUM RAILING ARE OUT OF DATEAND NOTVALID WITHOUTAN ORIGINAL SIGNITUREAND RAISED SEAL 106.1.1 NOT 9,00AAS-Y 0 05/0220127 ✓Comment GENERAL NOTES SHOULD INCLUDE WEATHERING & TERMLIE AREA [SEE TABL,�/01(2)1], FLAME SPREAD & SMOKE DEVELOPED INDEX FOR WAUJCEILINr/FINISH [SEE R 315] FLAME SPREAD SMOKE DEVELOPED INDEX & 95tITICALO&IANT FLUX FOR I �PULATION [SEE R 316], G*PSUM BOARD MATERIAL CONFORMS WITH R 702.3.1, AND CERAVICTILE CONFORMS WITH R 702.4. 05102120128 omment INCLUDE BASE FLOOD ELEVATION PER FEMA ON SURVEY. WILL USE WORST CASE FOR FLOOD PROOF CONSTRUCTION BELOW BFE R 323. 05102/20129 1/Comment STOPPED REVIEW. A COMPLETE REVIEW CAN NOT BE DONE TILL ALL CONSTRUCION DRAWINGS ARE RECEIVED. To Be Reviewed by Zoning Complete 03/30/2012 To Be Review by Plans Exan Pending Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Zoning Review Incomplete Review Comments for Contractor Lydia Galbraith 03/3012012 Page 3 03/36/20121 Comment PLEASE PROVIDEA COPY OF THE COMPLETE FDEP PERMIT. 03/30/20122 Comment WE RECEIVED ONE BOUNDARY &TOPOGRAPHIC SURVEYAND ONE GRADING & DRAINAGE PLAN SURVEY. THEY SEEM NOT TO MATCH WITH EACH OTHER. YOU ARE REQUIRED TO HAVE TWO SIGNED AND SEALED SURVEYS SHOWING ALL PROPOSED STRUCTURESANDIMPROVEMENTS. PLEASE REMOVEALL VEGETATION INFORMATION OF THE BOUNDARY SURVEYAND PROVIDE CLEAR COPY, WEARE NOTABLE TO CHECKANY DIMENSIONS, SETBACKS OR OTHER INFORMATION. PLEASE PROVIDE DIMENSIONS OF THE HOUSE AND PROPOSED FFE. PLEASE PROVIDE THE LINES OF THE DIFFERENT FLOOD ZONES AND ELEVATION SO WE CAN DETERMINE WHICH FLOOD ZONE THE HOUSE IS IN. PLEASE PROVIDE THE FRONT SETBACK TO THE EDGE OF THE ASPHALT OF THE ROAD (MUST MEET 20) PLEASE PROVIDE 2 SIGNED AND SEALED CORRECTED COPIES. 03/30/20123 Comment PLEASE PROVIDE 2 SIGNED AND SEALED SET OF TRUSS PLANS SIGNED ANDAPPROVED BY THE ARCHITECT OR ENGINEER OF RECORD. 03/30120124 Comment THE HOUSE IS CONSIDERED THREE STORYAND SHOULD BE LABELLED ACCORDINGLY. 03/30/2012 5 Comment PLEASE PROVIDE THE MEAN HEIGHT OF THE HIGHEST ROOF ON THE ELEVATION PAGE. WE NEED THE INFORMATION TO DETERMINE IF THE CONSTRUCTION IS NOT GOING OVER THE MAX HEIGHT REQUIREMENTS OF 35'. THE HEIGHT WILL BE MEASURED FROM THE MIN: ELEVATION OF THE FIRST HABITABLE FLOOR DETERMINED BY FDEP. 04/02/20126 Comment PLEASE BE AWARE THAT THE POOL IS NOT PART OF THIS PERMIT AND REQUIRES A SEPARATE PERMIT APPLICATION AND PLANS. 04/03/2012 7 Comment PLEASE PROVIDE TWO SIGNEDAND SEALED SETS OF STRUCTURAL PLANS PAGE S1-S7 04/03/2012 8 Comment PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVEADDITIONAL COMMENTS. TRANSMISSION VERIFICATION REPORT TIME : 05/02/2012 11:14 NAME : SLC INSPECTIONS FAX : 7724626443 TEL : 7724622165 SER.* : BROE5J278862 DATE,TIME 05/02 11:13 FAX NO./NAME 915615377226 DURATION 00:00:59 PAGE(S) 03 RESULT OK MODE STANDARD Planning & Development Services Building & Code Regulation Division Pernutting 0epartment 2300 Virginia Avenue Fort Pierce, FL 24902 Phone: (772)482.1553 Fax: (772) 462A 578 05/02/2012 22652 PHOENIX REALTY HOMES INC TARP ELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 Permit Number•, 1203-0269 Review Comments for Contractor Page 1 As of today's date the owner listed on your application is being notified along with yourself that the referenced building permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to contlnue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION 8316 OCEAN JENSEN BEACH 34957 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type. New Permit Type: Building Residential (SFR) OR SAM T STEGER 3201 SW WINDING WAY PALM CITY, FL 34990 Applicab'on Type; Master Permit w/subs Other Activity: Stories 3 1' PHOENIX REALTY HOMES, INC. Luxury Custom Home Builder Steger Residence PR# 1203-0259 St Lucie County Building Comments SCANNED St. Lucey County Comments from Dawn Milone Comment 1 Please provide recorded NOC at time of pick up Phoenix will submit at time of permit pick up 1760 North Jog Road Suite 140 West Palm Beach, FI. 33411 Phone (561)799-5900 Fax (561)537-7226 Comment 2 Please provide filled land affidavit at time of pick up See attached signed Land affidavit (Original) Comment 3 5/26/2012 - Still missing a roof sub agreement and Gar sub agreement — All others were submitted l See attached signed sub agreements for Roof and Gas Comments 4 The Mechanical sub -contractors is on hold. Liability insurance is expired/ Dana AC has sent over the updated insurance and is now current Comments from Dave Johnson Comment 1 — 6/15/2012 - Missing Product approval for exterior French Doors and Sliding Glass Doors Please see attached Updated NOA's Comment 2 — Structural drawings for Aluminum railing are out of date and not valid without an original signature and raised seal 106.11 See attached updated railing detail Comment 3 — Structural foundation plan note garage floor at 8.83NGVD. Survey shows garage floor at 9.5NGVD. Architectural plans pages 101.301.302.401, &801 note garage at 9 NGVD. All plans should match with each other FBC.106.1.1. See attached plans are showing Basement at 9.00. First Floor is at Elevation 18.50, as approved by DEP: A101, A301 and A401. See attached update survey Comment 4 — Foundation plan layout designates PC 3 front of home by stairs PC3 details does not match on layout same for PC2 Pile Caps. Please check and correct as needed See Attached Revised Architectural plans Comment 5 - Provide Grade Beam Details See Attached revised Architectural and Engineering plans comment 6 Fireplaces — Prov.� :-aanufactures spec's with installation insV___ . ;ins for fire places revised and signed by design professional of recorded in Duplicate Deferred until framing Comment 7 — Note on plans ceiling details for all exterior porches balcony's ECT. See Attached plans: Modified: A206 and A207. Comment 8 — Provide new page E 104 page submitted is not legible (to small to read) See Attached plans: Modified: E104. Comment 9 and 10 — Note on plans dryer vent and Bathroom Exhaust vent termination See Attached revised HAVC Layout Comment 11 - Please show attic access on plans See Attached plans: Modified: A202 and A203. Comment 12- Provide shop drawings for Epicore floor system reviewed and signed by design professional of record include shoring details To be deferred Comment 13 - Note plan door separating lobby from garage are solid core wood or 20minute? See attached revised Architectural Comment 14 — Note on plans garage floor is sloped toward main vehicle doors See Attached plans: Modified: A201. Comment 15 — Structural plans note 5000PSI for all concrete architectural plans Note 2500 PSI for concrete and 3000 PSI for Masonry Grout. See Attached plans: Modified: A001 and A801. Comment 16 - Show location of electrical panels on plans. See Attached plans: Modified: A201. Comment 17 - Please show the hot water heater on the plans. See attached plans: Modified: A201. Comment 18 - Gas riser detail. I will have my gas company do this. To be deferred Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1563 Fax: (772) 462-1678 031151201210 06/01/201214 Front Counter Review Review Comments for Contractor Page 2 PLEASE PROVIDE SUBAGREEMENTS FOR ELECTRICAL, PLUMBING, MEOHANIUALANU KUi ASUB SUMMARY SHEET. 5/25/12 WE ARE STILL MISSING A ROOF SUB AGREEMENTAND GAS SUB AGREEMENT -ALL OTHERS WERE SUBMITTED Comment VEG PERMIT PUT IN BIN 4-04-2012 VEG PERMIT IN DRAWER UNDER (S) FOR STEGER FEESARE LOADED IN COMPUTER SYSTEM: AHUMPHREY Comment THE MECHANICAL SUBCONTRACTOR IS ON HOLD, HIS LIABILITY INS. HAS EXPIRED AND HIS WIC WILL EXPIRE 6/28/112. Complete Dawn Milone 0311412012 0311512012 Plans Examiner Review Pending Dave Johnson 04/3012012 05101/20122 Comment PROVIDE FL PRODUCT APPROVAL FOR ALL EXTERIOR DOORSAND WINDOWS 613 FBC 6115112: MISSING PRODUCT APPROVAL FOR EXTERIOR FRENCH DOORS & SLIDING GLASS DOORS 05102120126 Comment STRUCTUAL DRAWINGS FORALUMINUM RAILING ARE OUT OF DATE AND NOT VALID WITHOUTAN ORIGINAL SIGNITURE AND RAISED SEAL I0SA.1 061151201211 Comment STRUCTURAL FOUNDATION PLAN NOTES GARAGE FLOOR AT 8.83 NGVD. SURVEY SHOWS GARAGE FLOOR AT 9.5 NGVD. ARCHITECTUAL PLANS PAGES 101,301,302,401,& 801 NOTE GARAGE AT 9 NGVD. ALL PLANS SHOULD MATCH WITH EACH OTHER. FBC 106.1.1 06/151201212 Comment FOUNDATION PLAN LAYOUT DESIGNATES PC 3 FRONT OF HOME BY STAIRS. PC 3 DETAIL DOES NOT MATCH WHAT$ ON LAYOUT. SAME FOR PC 2 PILE CAPS. PLEASE CHECKAND CORRECT AS NEEDED. 061151201213 L.) Comment PROVIDE GRADE BEAM DETAILS 06115/201214 Comment PROVIDE MANUFACTURERS SPECS WITH INSTALATION INSTRUCTIONS FOR FIREPLACES REVIEWEDAND SIGNED BY DESIGN PROFRESSIONAL OF RECORD IN DUPLICATE 061161201215 Comment NOTE ON PLANS CEILING DETAILS FOR ALL EXTERIOR PORCHES, BALCONY'S ECT. 061161201216 Comment PROVIDE NEW PAGE E 104. PAGE SUBMITTED IS NOT LEGIBLE (TO SMALL TO READ). 06/15/201217 Comment NOTE ON PLANS DRYER VENT TERMINATION 06/151201218 Comment NOTE ON PLANS BATHROOM EXHAUST VENT TERMINATIONS 06/15/201219 Comment SHOW ATTIC ACCESS ON PLANS 061151201220 Comment PROVIDE SHOP DRAWINGS FOR EPICORE FLOOR SYSTEM REVIEWED AND SIGNED BY DESIGN PROFFESSIONAL OF RECORD. INCLUDE SHORING DETAILS 5 G'a Review Comments for Planning& Development Services Contractor Building & Code Regulation Division Permitting Department Page 3 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462.1553 Fax: (772) 462.1578 0611512012 21 Comment NOTE ON PLANS DOORS SEPERATING LOBBY FROM GARAGE ARE SOLID CORE WOOD OR 20 MI FIRE RAI tD 061151201222 Comment NOTE ON PLANS GARAGE FLOOR IS SLOPED TOWARD MAIN VEHICLE DOOR 06115/201223 Comment STRUCTUAL PLANS NOTE 5000 PSI FORALL CONCRETE. ARCHITECTUAL PLANS NOTE 2500 PSI FOR CONCRETE AND 3000 PSI FOR MASONRY GROUT. 061151201224 Comment SHOW LOCATION OF ELECTRICAL PANEL ON PLANS 061151201225 Comment SHOW LOCATION OF WATER HEATER ON PLANS 06115/201226 Comment PROVIDE GAS RISER DIAGAM IN DUPLICATE To Be Reviewed by Zoning Complete To Be Review by Plans Exan Pending 0313012012 Zoning Review Incomplete Lydia Galbraith 0313012012 03130120121 Comment PLEASE PROVIDEA COPY OF THE COMPLETE FDEP PERMIT. 611112 RECEIVED NOTICE TO PROCEED, PLEASE PROVIDE THE COMPLETE FDEP PERMIT. 06117/20129 Comment ADD NOTES FOR MITIGATION IN INSPECTIONS FOR ERD. 061011201210 Comment THE SURVEY IS NOT MATCHING WITH THE FOUNDATION PLAN. DIMENSIONS ARE OFF. THE PROPOSED FINISHED FLOOR ELEVATION IS NOT MATCHING WITH THE BUILDING PLANS. THE FFE OF THE FIRST HABITABLE FLOOR CANT BE HIGHER THAN 29 CHIMNEY ON HIGHER FLOORS NEED TO SHOW ON SURVEY AS DOTTED LINES AND MAY NOT ENCROACH IN THE SETBACK THE FRONT BALCONY NEED TO SHOW ON THE SURVEYAS WELLAND ISALSO NOTALLOWED THE ENCROACH IN THE FRONT SETBACK I 0 , Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)4624553 Fax:(772)462.1578 06/15/2012 22862 PHOENIX REALTY HOMES INC TARPELL, ALAN J 1760 N JOG RD SUITE 140 WEST PALM BEACH, FL 33411 Permit Number: 1203-0259 Review Comments for Contractor Page 1 As of today's date the owner listed on your application is being notified along with yourself that the referenced building permit has some issues listed in the comments below. Please address these issues as quickly as possible so that we are able to continue to process this permit in a timely manner. If you have any questions regarding the comments below, please call our office. PROPERTY INFORMATION OWNERS INFORMATION 8SAM T. STEGER 318 OCEAN OR 3201 SW WINDING WAY JENSEN BEACH 34957 PALM CITY, FL 34990 APPLICATION INFORMATION Permit Number. 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) REV/EWSAND COMMENTS Application Type: Master Permit w/subs Other Activity: Stones 3 Review Tyne status Reviewed By Date Started Date Comolote Date Released Addressing Assignment Complete Lydia Galbraith 0410312012 Documents Missing Pending Dawn Milone 0311412012 03115/20121 Comment PLEASE PROVIDE RECORDED NOCAT TIME OF PICKUP 03/15120122 Comment PLEASE PROVIDE FILLED LANDS AFFIDAVIT AT TIME OF PICKUP Si1112 SUBMITTED FILLED LANDS AFFIDAVIT IS ACOPY, PLEASE SUBMIT THE ORIGINAL AT TIME OF PICKUP. t b5-9 I BOARD OF COUNTY _ PLANNING & DEVELOPMENT COMMISSIONERS' q �,'w SERVICES DEPARTMENT BUILDING & CODE REGULATION DIVISION FAX COVER SHEET FAX #: (772) 462-6448 PHONE #: (772) 462-1553 DATE: k I12 NO. OF PAGES INCL. COVER: TO: ATTN: :1-gc) RE: 00E)— M,5G SENDER: Lydia Galbraith PHONE #: 462-1555 COMMENTS:Q ZlQ1IflU �Pt�CI U Q�� �� 3 Planning &Development Services Building & Code Regulation Division Review Comments Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Page 1 Phone: (772) 462-1553 Fax: (772) 462-1578 PROPERTY INFORMATION Address: 8316 OCEAN DR S City I State I Zip: JENSEN BEACH Parcel # : 3527-501-0043-000/8 Zoning: HIRD APPLICATION INFORMATION Permit Number: 1203-0259 Activity Type: New Permit Type: Building Residential (SFR) FL 34957 Jurisdiction: St. Lucie County Lot#: 42 Block: CONTRACTOR INFORMATION Contractor Name: TARPELL, ALAN J Business Name: PHOENIX REALTY HOMES INC Business Addr: 1760 N JOG RD SUITE 140 City / State /ZiF WEST PALM BEACH, FL 3 REVIEWS AND COMMENTS Owner(s): SAM T. STEGER KAREN O STEGER Application Type: Master Permit w/subs Other Activity: Stories: 3 Automatic Sprinkler System? ❑ Fax Number 561-537-7226 Review Type Status Reviewed By. Date Started Date Complete Date Released Addressing Assignment Complete Lydia Galbraith 0410312012 Documents Missing Pending Dawn Milone 0311412012 03/15/2012 1 Comment PLEASE PROVIDE RECORDED NOC AT TIME OF PICK UP 03/15/2012 2 Comment PLEASE PROVIDE FILLED LANDS AFFIDAVIT AT TIME OF PICKUP 03/15/2012 4 Comment PLEASE PROVIDE SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICALAND ROOF AND A SUB SUMMARY SHEET. 03/15/2012 6 Comment PLEASE PROVIDE 2 SIGNED SET OF MANUAL TS AND ENERGY CALCS 03/15/2012 8 03/15/2012 10 04/02/2012 11 04/02/2012 12 Comment PLEASE PROVIDE OWNERS PHONE # Comment VEG PERMIT PUT IN BIN Comment PLEASE PROVIDEA COPY OF THE PAID UTILITIES FOR WATER & SEWERATTIME OF PICK UP. Comment PLEASE PROVIDEA LETTER FROM THE POWER COMPANYTHAT ELECTRIC WILL BEAVAILABLE FOR THIS PROPERTY. YOU CAN BRING IT IN ATTIME OF PICKUP. Front Counter Review Complete Dawn Milone 0311412012 03115/2012 Planning & Development Services Building& Code Regulation Division Review Comments Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Page 2 Phone: (772) 4624553 Fax: (772) 4624578 To Be Reviewed by Zoning Complete To Be Review by Plans Exar Pending Zoning Review Incomplete Lydia Galbraith 0313012012 03130/2012 03/30/2012 1 Comment PLEASE PROVIDE COPY OF THE COMPLETE FDEP PERMIT. 03/30/2012 2 Comment WE RECEIVED ONE BOUNDARY & TOPOGRAPHIC SURVEY AND ONE GRADING & DRAINAGE PLAN SURVEY. THEY SEEM NOT TO MATCH WITH EACH OTHER. YOU ARE REQUIRED TO HAVE TWO SIGNEDAND SEALED SURVEYS SHOWING ALL PROPOSED STRUCTURES AND IMPROVEMENTS. PLEASE REMOVE ALL VEGETATION INFORMATION OF THE BOUNDARY SURVEYAND PROVIDE A CLEAR COPY, WE ARE NOTABLE TO CHECK ANY DIMENSIONS, SETBACKS OR OTHER INFORMATION. PLEASE PROVIDE DIMENSIONS OF THE HOUSE AND PROPOSED FFE. PLEASE PROVIDE THE LINES OF THE DIFFERENT FLOOD ZONES AND ELEVATION SO WE CAN DETERMINE WHICH FLOOD ZONE THE HOUSE IS IN. PLEASE PROVIDE THE FRONT SETBACK TO THE EDGE OF THE ASPHALT OF THE ROAD (MUST MEET 20') PLEASE PROVIDE 2 SIGNEDAND SEALED CORRECTED COPIES. 03/30/2012 3 Comment PLEASE PROVIDE 2 SIGNEDAND SEALED SET OF TRUSS PLANS SIGNED ANDAPPROVED BY THEARCHITECT OR ENGINEER OF RECORD. 03/30/2012 4 Comment THE HOUSE IS CONSIDERED THREE STORYAND SHOULD BE LABELLED ACCORDINGLY. 03/30/2012 5 Comment PLEASE PROVIDE THE MEAN HEIGHT OF THE HIGHEST ROOF ON THE ELEVATION PAGE. WE NEED THE INFORMATION TO DETERMINE IF THE CONSTRUCTION IS NOT GOING OVER THE MAX HEIGHT REQUIREMENTS OF 35'. THE HEIGHT WILL BE MEASURED FROM THE MIN. ELEVATION OF THE FIRST HABITABLE FLOOR DETERMINED BY FDER 04/02/2012 6 Comment PLEASE BEAWARE THATTHE POOL IS NOT PART OF THIS PERMITAND REQUIRES A SEPARATE. PERMITAPPLICATION AND PLANS. 04/03/2012 7 Comment PLEASE PROVIDE TWO SIGNEDAND SEALED SETS OF STRUCTURAL PLANS PAGE S1-S7 04/03/2012 8 Comment PLEASE BE AWARE THATABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. TRANSMISSION+ VERIFICATION REPORT TIME : 04/01/2012 16:58 NAME : SLC CODE COMP FAX : 7724626448 TEL : 7724622963 SER.0 : BROE5J278861 DATE,TIME 04/01 16:57 FAX NO./NAME 915616591197 DURATION 00:00:50 PAGE(S) 03 RESULT OK MODE STANDARD ECM E�b1- 5b - _ f9ltrn . BOARD OF COUNTY PLANNING &DEVELOPMENT COMMISSIONERS SERVICES DEPARTMENT BUILDING & CODE REGULATION DIVISION FAX COVER SHEET FAX #: (772) 462-6448 PHONE #: (772) 462-1553 DATE: ��Z NO. OF PAGES INCL. COVER: TO: f i .F '� RE: SENDER: Lydia Galbraith COMMENTS: PHONE #: 462-1555 1k 3