HomeMy WebLinkAboutSUBMITTED PAPERSE D ST. LUCIE COUNTY PERMIT
St. Lucie County
ZAPKMIT NO.ICATION FOR PERMIT TO CONSTRUCT
OD LOCATION/ADDRESS: 29� 66 2
YEGAL DESCRIPTION Harbour Ridge,
APPLICATION
(CODE # ) SEWAGE PERMIT NO. reatment Plant
Garden Apartments (8 Units) and Attached Garages cLl
IMPACT: DISTRICT A� DY %L% U n ZONE FEE —CM V
Harbour'Ridg"'e b MAP # FLOOD ZONE' ELE
`"PI:AT�
GG 8 K VI UNIT Bldg. 4 SEC N' i Z6 TWP 37 S RGE" `"' E
T
ZIR11=0007om
Li/LL�ae-tL INCSK � �
,
"' � ZONE tkI GMPP t
LO SIZE/DIMENSIO 5V895.73' x 673.53'/x 0u, — - x✓�68.777' �7 / EST COST $5�70,1(4�4�.0p0 7 T
SET BACKS: FRO '� �REAR`� 69.42' SIDE `S (l 1 SIDE ! /i� � r
�Q FT BUILDING: LIVING AREA 12,704 S.F. ACCESSORY V '.468 S.F.
6"es 333o
ARCHITECT: NAME Lester W. Bosse PHONE 336-1800
ADDRESS P. 0. Box 2451
+CONTRACTOR: STATE RGG/CERT # " CGC A08454
AME J & N Construction,
CITY Palm City
OWNER OF AME —
PROPERTY:
Harbour Ridge, Ltd.
CITY Stuart ST FL Zip 34115
COUNTY CERT # 8796
Inc. ADDRESS 13500 N.W. Gilson Road
—
STATE FL ZIP
ADDRESS 13500 N.W. Gilson Road
CITY Palm City STATE
STATE OF FLORIDA, COUNTY OF ST. LUCIE
Before me, the undersigned authority, personally peared —
being duly sworn, deposes and says that the informatio c n ine tf�
.a 0 �mfl, I qa
ohn E. Mo
worn to and subscribed44\\e f�ti /. �d�ay of _
/!qu-1red
34990 336-1160
PHONE
— PHONE 336-1160
N
FL ZIP 34990
John E. Moore , who upon
foregoing application is true and correct.
Applicant
19�.
FIE -ES /&Aw o rti . CJ—
No f 4 U
Notary lic, State of Florida at Large Amt. PdpC
v Pn=Cc. Bra+�
My Commission expires: - - nt Fin:�da Date Pd �[
Posted
CHECK LIST
J�
PR/ 90-0034
(So. Shore Village)
Project Name: Harbour Ridge - 8 Unit Garden Apartment & Attached Garages
Architect:' Lester W. Boese Ph: 336-1800 (Stuart)
Contractor: J & N Construction, Inc. ph: 336-1160 (Palm City)
Owner: Harbour Ridge, Ltd. ph: 336-1160 (Palm City)
Address: 12366-12380 Harbour Ridge Blvd. Palm City, F1
Occupancy Classification: 9
Type of Construction:
Height and Area:
occupancy Requirements per Chapter IV: ,
Construction Requirements:
A. Fire Protection:
B. Egress Requirements:
Other Requirements:
AM
i�
Elevators
Sprinklers A Standpipes
Combustible Materials - Interior
Roof Coverings
Light - Ventilation - Sanitation
�,4., ro�P" �rs lac"�o b�
Handicap Requirements mPew%N I e
C° "Apte-k {vc 29 C�A� r "9
Plans sent to Fire Dept. - Date:
Plot Plan Chech
Water Sewer
Energy Code
Paving & Drainage approval by Engineering Dept.
Special Conditions prior to issuance
Threshold Affidavit/Before Issuance Affidavit
Approved:
w
BUILDING PLAN CHECK
ST. LUCIE COUNTY- FORT PIERCE FIRE PREVENTION BUREAU
FORT PIERCE, FLORIDA
TELEPHONE 465-6655
PROJECT'NAME: HARBOUR RIDGE GARDEN APTS.
PLAN NUMBER
#1986
DATE RECEIVED 2-1-90
CONTRACTOR: J & N Construction . PHONE NUMBER: 336-1160
ARCHITECT: Lester W. Boese PHONE NUMBER: 336-1800
OWNER:
LOCATION:
TYPE OF OCCUPANCY:
SIZE OF BUILDING: —
REQUIREMENTS:
Harbour Ridge
f2366-12380 Harbour
Residential
12,704 sq. ft
Blvd.
TYPE OF CONSTRUCTION:
NUMBER OF FLOORS: 2
1 Sheet E-1 The smoke detector has been overlooked in the corridor leading to master bedroom.
2 The stair hand and guard rail detail is not shown. The plan sheet shows only one handrail
NFPA 101 5-2 2 6 2 Each new stair shall have handrails on both sides of the stairway.
3. The penetration of fire resistant walls or partitions, floors or floor ceiling assemblies
for electrical, telephone, plubming, air conditioning, intercommunications system, or
similar facilities shall not be permitted unless such openings are installed in such a
manner that the fire resistance is not reduced.
4. Penetration ;by metal or PVC (plastic) piping through rated concrete floor or wall assemblies
shall be installed using an approved fire safe material. Diameter of penetrating holes
shall be in accordance with Underwriter's Laboratories system
u
manufacturer's requirements for the pipe diameter.
5. There is no section shown on tenant separating walls.
number or other approved
® NOTE: Tenant separating walls shall extend from the floor to tight against the roof deck.
CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS
24 HOUR NOTICE REQUIRED ON ALL INSPECTIONS
REVIEWED cv �DATE
IZ SIGNATUR
BUILDING PLAN CHECK
ST.. LUCIE COUNTY- FORT PIERCE FIRE PREVENTION BUREAU
FORT PIERCE, FLORIDA
TELEPHONE 465-6655
PLAN NUMBER 1i1986
DATE RECEIVED
CONTRACTOR: PHONE NUMBER:
ARCHITECT: PHONE NUMBER:
OWNER:
LOCATION:
TYPE OF OCCUPANCY: TYPE OF CONSTRUCTION:
SIZE OF BUILDING: NUMBER OF FLOORS:
REQUIREMENTS:
Truss assemblies are not part of a rated assembly. The wall must extend to the roof deck.
L • .
CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS
24 HOUR NOTICE REQUIRED ON ALL INSPECTIONS
REVIEWED [�/- DATE'' 90
// SIGNATI E