Loading...
HomeMy WebLinkAboutTHRESHOLD REPORT SUMMARY0 AVCON, INC. ENGINEERS & PLANNERS 5555 E. Michigan St., Suite 200 Orlando, Florida 32822 AVCON Project No. 2017.159.01 Phone: (407) 599-1122 November 8, 2019 SCANNED Fax: (407) 599-1133 BY www.avconinc.com St. Lucie County St. Lucie2300 Virginia Avenue County Fort Pierce, FI 34982 Attention: Mr. Jim McGuinness, Building Official Reference: MRO FPR Hangar Project No 90.r1 7 St. Lucie County, Florida THRESHOLD REPORT SUMMARY NO.5 Dear Mr. McGuinness: As directed, representatives from AVCON, Inc. performed on -site, threshold inspection services for the MRO FPR Hangar project. This report summarizes our threshold inspection services performed during the inspection period of November 4, 2019 through November 8, 2019. Inspections took place on November 6, as the rebar for the footings were re -inspected prior to the placement of concrete, as well as the concrete placement. Our inspections were performed in accordance with the structural documents, signed, and sealed by the Engineer of Record, Luca DelVerme PE (AVCON INC), and the project specifications. Our special inspector and his duly authorized representative(s) reported their observations as noted on the attached Daily Threshold Reports with all structural non-compliance items noted within the attached Special Inspection Log (SIL). All non-compliance items, or SIL's, previously reported as non -compliant with regard to the plans or specifications, will be reevaluated by our Special Inspector after corrective action is taken by the General Contractor or the deficient conditions have been approved through written approval by the Engineer of Record. During the inspection period of November4, 2019 through November 8, 2019, and to the best of our knowledge and belief, the construction of all structural load -bearing components described in the threshold inspection plan complies with permitted documents, with revisions as approved by the Engineer of Record, except as noted on the SIL. Should you have any questions or concerns regarding these reports, or desire any additional information, please contact us. Sincerely, AVCON, Inc. Certificate of Authorization No. 5057 � t! 8aZ2!!�O__41 /0ir RickV. Boldocchi, P.E. Vice President STATE OF FLORIDA Professional Engineer No. 38092 Registered Special Inspector No. 1019 n.m,.�ane..�.....�.a...a q ea uaimR 3+���+`` esssusrw�cw mean ag rxou�'"' a� nxxmx �3 e` ¢n.ur�mvm<w. cc: Addressee, Gary Stepalavich SteoalavichGPstlucieco.ore County Project Manager, Scotty Beaulieu beaulieusc@stlucieco.org Chief Plans Examiner, William Durden DurdenW@stlucieco.org Construction Project Manager, Robert Hatton rhatton@ahrenscompanies.com CIVIL & STRUCTURAL 9 AIRPORT & AVIATION CONSULTING • TRANSPORTATION DESIGN & PLANNING AVCON Project No. 2017.159.01 November 8, 2019 St. Lucie County 2300 Virginia Avenue Fort Pierce, FI 34982 Attention: Mr. Gary Stepalavich, Building Official Reference: MRO FPR Hangar Permit No. 2907-0550 & 1812-0471 St. Lucie County, Florida THRESHOLD REPORT SUMMARY NO. 5 INSPECTOR(S): Rick Baldocchi (AVCON, Inc.) DAILY REPORT(S): Threshold Inspection Daily Report(s): 21/06/19 [See attached report(s) for locations and observations.] SPECIAL INSPECTION LOG: Added this Summary Period: Resolved this Summary Period: Outstanding for the Project: ATTACHMENT(S): - None. 51 A y Page 2 of 2 AVCON, INC. ENGINEERS & PLANNERS 5555 E. Michigan St., Suite 200 Orlando, Florida 32822 Phone: (407) 599-1122 Fax: (407) 599-1133 www.avconine.com CIVIL & STRUCTURAL 9 AIRPORT & AVIATION CONSULTING • TRANSPORTATION DESIGN & PLANNING AVCON, INC. ENGINEERS & PLANNERS SPECIAL INSPECTION LOG Permitting Agency: St Lurie County Project Name: FPR MRO Hangar Update Period: 11/04/19 to 11/08/19 1907-0550 Peril No.: 1907-0550 - Foundation & Pmlect No.: 2017.0259.01 8 -0- Structure Attention: Ahrens Construction/St Lucie County Project Location: Port St. Lucie, St. Lucie County, Florida Threshold Agent Rick V. Beldocchl SIL No. Date Daily RepartNo. Structural Element Location e Description 1 S.I. Engineer of Record Response Date Closed Closed Daily Report No. 1 8-26-19 SIL Helical Piles N/A The helical pile submittal on RVB FOR approved RVB 10/30/19 009 Summary Submittals site does not have SEOR or calculations and 1 County Building Department revised plans acceptance stamp. 2 BJ0-19 SIL Helical Piles Footings A-7 & L-7 The contract documents do RVB FOR approved RVB 10/30/19 009 Summary not show helical piles within calculations and 2 the footings. revised plans 3 09/20/19 SIL Helical Piles Feelings A-7—C-7, The contract documents do RVB FOR approved RVB 10/30/19 009 Summary 3 F7 — L7, G-8 & L-8, not show helical piles within calculations and G-9—L-9 the footings, revised plans 4 10/02/19 SIL Foundations All locations The rebar in the top mat RVB Delegated engineer RVB 11/01/19 009 Summery 4 deviate from plans/shop submitted letter drawings regarding the removal of tap mat hooks - FOR accepted ¢ The special Inspector, Rick V. Beldocchi, P.E., acknowledges this deficiency. a The Special Inspector, Rick V. Baldoochl, P.E., acknowledges resolution to this deficiency. This is a brief summary of the SIL Refer to the daily report for a detailed description. Page 1 o1 i PROJECT: FPR MRO Hangar LOCATION: Treasure Coast International Airport & Business PERMIT AGENCY: St. Lucie County CLIENT: FIELD CONTACT: Robert Hatton COMMENTS SCOPE OF WORK: DATE:11/06/19 WORK ORDER NO.: BUILDING PERMIT NO.: Permit No. 1812-0471 Re -inspected rebar that was placed for foundations over the helical pile caps. Final elevations for anchor bolts were corrected prior to the concrete placement, as well as general housekeeping to ensure that vegetation growth was removed. Temperature avg. was 71-84 degrees, wind avg. was 0-9 mph. No significant rainfall occurred during the concrete placement. Concrete mix SW695R30 Spec W/C 0.50 #57 was used. The first truck arrived on -site at 7:10am with 11 CY out of 200 CY. Bolts were reset during the concrete placement. Final truck began to place concrete at L1 at 2:30pm, for a total of approx. 238 CY. INSPECTOR: Jason Teliszczak - w/Avcon FIELD COPIES TO: AVCON AVCON, INC. ENGMURS s PL%NNERS 5555 E. Michigan St., .Suite 200 Orlando. Florida32822 , -Plmne:(407)599-1122 F.; (407) 599-1133 w w avconinc.00m