HomeMy WebLinkAboutSUBMITTED PAPERSa
Product Review Affidavit --
St. Lucie County, Public Works Department
Code Compliance Division
The following products will be installed in the structure located easterly of Florida Turnpike, southerly of I-95,
and northwesterly of Glades Cut -Off Road.
Building Permit #
Owner's Name: Wal-Mart Stores East, LP — (Contact: Joe Loethen)
Owner's Address: 2201 Southeast 10`h Street Dept. 9562 Bentonville AR 72716-0550
Contractor: To Be Determined Contractor's Address: To Be Determined -
Guardhouse
Product
`Product Rated
Manufacturer
Model
Method of Attachment
Design Pressures (psfj
Number
Windows (St orefront/Entrance) - See Product Review Af avit provided by Carter & Burgess
Fixed Glass- See Product Review Affidavit provided by Carter & Burgess
Glass (Other) — Not Applicable
Sliding Glass -Doors — Not Applicable
Swing Type Doors
Metal Door
+35, -38
Dominion
AMSCO KD,
Head Anchor: (2) %z" diameter A325
for Metal
Building
20 Gage
bolts at each jamb.
Building
Products
Floor Anchor: (2)'/z" diameter
masonry anchors at each jamb.
Overhead Doors- See Product Review Affidavit provided by Carter & Burgess
Roofing Material
Exposed
-30.4 psf uniform
Butler
BR II
26 gage roof panels attached 1' o.c.
Fastener
-46.8 psf edge
Manufacturing
26 Gage
with 14-IOxI" HWH Type A screws
Roof System
-65.3 psf corner
Company
to 7/16" OSB Plywood. @ 2.5'
spacing.
Shutters- See Product Review Affidavit provided by Carter & Burgess
*Fill in the rated wind design pressures listed by the manufacturer for each product listed.
I have reviewed the above components and cladding, and have approved their use in the structure to provide
adequate resistance to the wind loads and forces specified by current code provisions.
Name: Steven M. Thomas
Design Firm: Butler Construction
Signature:
Cert. No.: 47919
SCANNED
BY
St. Lucie County
Date: 07/18/03
ST LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
2400 Rhode Island Avenue Telephone: 772-462-8306
Ft Pierce, FL 34950
FAX: 772-462-8466
(/44w Construction
( )Tenant Improvement ( )Addition ( )Renovation/alterations
( )Shell Only
Jurisdiction:
SLC F.P.B.:
B-03-99
Occupancy:
Walmart Distribution Guard House Building Dept:
23030442
Address:
4001 S. Jenkins Rd. Number of stories:
1
Contractor
Unknown at this time Phone #
Contractor's Address:
City:
State: IZip
Code:
Architect/Engineer:
Carter & Burgess, Inc. Phone #
817-222-8736
Building Owner:
Wal-Mart Stores East Review Date:
4/22/2003
Occupancy Type:
Business Automatic sprinklers:
Gross sq ft:
424 Net sq ft: .
Occupant Load:
Based On:
Construction Type:
SBCCI Type:
VI unp
NOTE
1. All revisions must be in compliance before the final inspection.
2. The Fire Marshal requires 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Permit fees are required to be paid in full prior to any inspections.
5. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ).
7. Penetrations through rated assemblies shall be of proper UL design.
f 8. UL design criteria shall be submitted with the construction plans.
THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED.
REVISIONS REQUIRED
ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( )
1. Provide portable fire protection.
Reviewed by: Date: 4/22/2003