Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSa Product Review Affidavit -- St. Lucie County, Public Works Department Code Compliance Division The following products will be installed in the structure located easterly of Florida Turnpike, southerly of I-95, and northwesterly of Glades Cut -Off Road. Building Permit # Owner's Name: Wal-Mart Stores East, LP — (Contact: Joe Loethen) Owner's Address: 2201 Southeast 10`h Street Dept. 9562 Bentonville AR 72716-0550 Contractor: To Be Determined Contractor's Address: To Be Determined - Guardhouse Product `Product Rated Manufacturer Model Method of Attachment Design Pressures (psfj Number Windows (St orefront/Entrance) - See Product Review Af avit provided by Carter & Burgess Fixed Glass- See Product Review Affidavit provided by Carter & Burgess Glass (Other) — Not Applicable Sliding Glass -Doors — Not Applicable Swing Type Doors Metal Door +35, -38 Dominion AMSCO KD, Head Anchor: (2) %z" diameter A325 for Metal Building 20 Gage bolts at each jamb. Building Products Floor Anchor: (2)'/z" diameter masonry anchors at each jamb. Overhead Doors- See Product Review Affidavit provided by Carter & Burgess Roofing Material Exposed -30.4 psf uniform Butler BR II 26 gage roof panels attached 1' o.c. Fastener -46.8 psf edge Manufacturing 26 Gage with 14-IOxI" HWH Type A screws Roof System -65.3 psf corner Company to 7/16" OSB Plywood. @ 2.5' spacing. Shutters- See Product Review Affidavit provided by Carter & Burgess *Fill in the rated wind design pressures listed by the manufacturer for each product listed. I have reviewed the above components and cladding, and have approved their use in the structure to provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Steven M. Thomas Design Firm: Butler Construction Signature: Cert. No.: 47919 SCANNED BY St. Lucie County Date: 07/18/03 ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Avenue Telephone: 772-462-8306 Ft Pierce, FL 34950 FAX: 772-462-8466 (/44w Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Jurisdiction: SLC F.P.B.: B-03-99 Occupancy: Walmart Distribution Guard House Building Dept: 23030442 Address: 4001 S. Jenkins Rd. Number of stories: 1 Contractor Unknown at this time Phone # Contractor's Address: City: State: IZip Code: Architect/Engineer: Carter & Burgess, Inc. Phone # 817-222-8736 Building Owner: Wal-Mart Stores East Review Date: 4/22/2003 Occupancy Type: Business Automatic sprinklers: Gross sq ft: 424 Net sq ft: . Occupant Load: Based On: Construction Type: SBCCI Type: VI unp NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. f 8. UL design criteria shall be submitted with the construction plans. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. REVISIONS REQUIRED ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( ) 1. Provide portable fire protection. Reviewed by: Date: 4/22/2003