DIVISION: 08 00 00=OPENINGS
SECTION: 089S 43—VENTS/FOUNDATION FLOOD VENTS
DEC 2 0 119
ST. Lucle County, Permitting
REPORT HOLDER:
SMART VENT PRODUCTS, INC.
EVALUATION SUBJECT:
SCANNED
BY
St. Lucie County
SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS:
IQiiD{ELSi540�0;#1540-521; #1540-510; #1540-511; #1540-570;'#1540-574;
#1540-524;#1540-514
FLOOD VENT SEALING KIT #1540-526
ICC�� ICC
ICC
pfljlG � LISTED
"2014 Recipient of Prestigious Western States Seismic Policy Council
(WSSPQ Award in Excellence"
A Subsidiary of
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically
addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.
There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this \\
report, or as to any product covered by the report.
Copyright 0 2019 ICC Evaluation Service, LLC. All rights reserved.
IMES Evaluation Report ESR-2074
www.1cc-es.org 1 (800) 423-6587 1 (562) 699-0543
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
SMART VENT PRODUCTS, INC.
EVALUATION SUBJECT:
SMART VEND AUTOMATIC FOUNDATION FLOOD
VENTS: MODELS #1540520; #1640521; #1540510; #1540-
511; #1540570; #1540-574; #1540524; #1540514
FLOOD VENT SEALING KIT #1540526 .
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2018, 2015, 2012, 2009 and 2006 International Building
Code (IBC)
■ 2018, 2015, 2012, 2009 and 2006 International
Residential Code® (IRC)
■ 2018 International Energy Conservation Code® (IECC)
■ 2013 Abu Dhabi Intemational Building Code (ADIBC)t
1The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced
in this report an: the same sections in the ADIBC.
Properties evaluated:
■ Physical operation
■ Water flow
2.0 USES
The Smart Vent® units are engineered mechanically
operated flood vents (FVs) employed to equalize
hydrostatic pressure on walls of enclosures subject to
rising or falling flood waters. Certain models also allow
natural ventilation.
3.0 DESCRIPTION
3.1 General: `
When subjected to rising water, the Smart Vent® FVs
internal floats are activated, then pivot open to allow flow in
either direction to equalize water level and hydrostatic
pressure from one side of the foundation to the other. The
FV pivoting door is normally held in the closed position by
a buoyant release device. When subjected to rising water,
the buoyant release device causes the unit to unlatch,
allowing the door to rotate out of the way and allow flow.
The water level stabilizes, equalizing the lateral forces.
Reissued February 2019
This report is subject to renewal February 2021.
A Subsidiary of the International Code Council
Each unit is fabricated from stainless steel. Smart Vent®
Automatic Foundation Flood Vents are available in
various models and sizes as described in Table 1. The
SmartVENl" Stacking Model #1640-511 and FloodVENT®
Stacking Model #1540-521 units each contain two
vertically arranged openings per unit.
3.2 Engineered Opening:
The FVs comply with the design principle noted in Section
2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section
2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and
IRC)) for a maximum rate of rise and fall of 5.0 feet per
hour (0.423 mm/s). In order to comply with the engineered
opening requirement of ASCE/SEI 24, Smart Vent FVs
must be installed in accordance with Section 4.0.
3.3 Ventilation:
The SmartVENTO Model #1540-510 and SmartVENT"
Overhead Door Model #1540-514 both have screen covers
with 1/44nch-by-1/4-inch (6.35 by 6.35 mm) openings,
yielding 51 square inches (32 903 mm) of net free area to
supply natural ventilation. The SmartVENT® Stacking
Model #1540-511 consists of two Model #1540510 units
in one assembly, and provides 102 square inches
(65 806 mmZ) of net free area to supply natural ventilation.
Other FVs recognized in this report do not offer natural
ventilation.
3.4 Flood Vent Sealing Kit:
The Flood Vent Sealing Kit Model #1540-526 is used with
SmartVENr Model #1540-520. It is a Homasote 440
Sound Barrier® (ESR-1374) insert with 21 — 2-inch-by-2-
inch (51 mm x 51 mm) squares cut in it. See Figure 4.
4.0 DESIGN AND INSTALLATION
4.1 SmartVENr and FloodVENT®:
SmarlVENTQ1 and FloodVENT® are designed to be
installed into walls or overhead doors of existing or new
construction from the exterior side. Installation of the
vents must be in accordance with the manufacturer's
instructions, the applicable code and this report.
Installation clips allow mounting in masonry and concrete
walls of any thickness. In order to comply with the
engineered opening design principle noted in Section
2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of
ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)), the
Smart Vent® FVs must be installed as follows:
■ With a minimum of two openings on different sides of
each enclosed area.
■ With a minimum of one FV for every 200 square
IMESEvahwion Repom arenot to be con "aw reprerenting aesthaias oranyother atoibutee notspecifimllyad*med nor are they to be construed
as an endorsement ofthe subject ofthe report or recomnerdauon far its we 77kere is no svarraory by rCC Evaluation Service. LLG express or implied, as
to anyfindng or other rnaaer in Misreport or as to anyprodnctcovered bythe report
Copyright 020191CC Evaluation Service, LLC. All rights reserved. Page 1 of 5
ESR-2074 I Most WMdelyAccepted and Trusted Page 2 of 5
feet (18.6 m) of enclosed area, except that the
SmartVENT® Stacking Model #1540-511 and
FloodVENT® Stacking Model #1540-621 must be
installed with a minimum of one FV for every
400 square feet (37.2 m) of enclosed area.
■ Below the base flood elevation.
■ With the bottom of the FV located a maximum of
12 inches (305.4 mm) above the higher of the final
grade or floor and finished exterior grade immediately
under each opening.
4.2 Flood Vent Sealing Kit
The Flood Vent Sealing Kit Model 1540-526 is used in
conjunction with FloodVENT® Model #1540-520. When
installed and tested in accordance with ASTM E283, the
FV and Flood Vent Sealing Kit assembly have an air
leakage rate of less than 0.2 cubic feet per minute per
lineal foot (18.56 Itmin per lineal meter) at a pressure
differential of 1 pound per square foot (50 Pa) based on
12.58 lineal feet (3.8 lineal meters) contained by the Flood
Vent Sealing Kit.
5.2 The Smart Vent® FVs must not be used in the place
of "breakaway walls" in coastal high hazard areas, but
are permitted for use in conjunction with breakaway
walls in other areas.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance with the ICC-ES Acceptance
Criteria for Mechanically Operated Flood Vents
(AC364), dated August 2015 (editorially revised
October 2017).
6.2 Test report on air infiltration in accordance with ASTM
E283.
7.0 IDENTIFICATION
7.1 The Smart VEND models and the Flood Vent Sealing
Kit recognized in this report must be identified by a
label bearing the manufacturer's name (Smarhrent
Products, Inc.), the model number, and the evaluation
report number (ESR-2074).
7.2 The report holders contact information is the
following:
5.0 CONDITIONS OF USE SMART VENT PRODUCTS, INC.
430 ANDBRO DRIVE, UNIT 1
The Smart Vent® FVs described in this report comply with, PITMAN, NEW JERSEY 08071
or are suitable alternatives to what is specified in, those (877) 441-8368
codes listed in Section 1.0 of this report, subject to the www.smartventcom
following conditions: info(ftmartvent.com
5.1 The Smart Vent® FVs must be installed in accordance
with this report, the applicable code and the
manufacturers installation instructions. In the event of
a conflict, the instructions in this report govern.
TABLE 1—MODEL SIZES
MODEL NAME
MODEL NUMBER
MODEL SIZE (in.)
COVERAGE (sq. ft.)
FloodVEN
1540-520
15 /4" X 73la'
200
SmartVENT®
1540-510
153/4" X 73W
200
FloodVENT® Overhead Door
1540-524
15314" X rW
200
SmartVENT® Overhead Door
1540-514
15a/4" X 73/4"
200
Wood Wall FloodVENT®
1540-570
14" X 83/4'
200
Wood Wall FloodVENT" Overhead Door
1 1540-574
14" X 83/4'
200
SmartVENT® Stacker
1540-511
16" X 16"
400
FloodVent® Stacker
1540-521
16" X 16"
400
For SI: 1 inch = 25.4 mm; 1 square foot = m2
FIGURE 1—SMART VENT: MODEL 1540-510
ESR-2074 I Most widely Accepted and Trusted Page 3 of 6
FIGURE 2—SMART VENT MODEL 1540-520
FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN
FIGURE 4—FLOOD VENT SEALING KIT
IMES Evaluation Report ESR-2074 CBC and CRC Supplement
Reissued February 2019
This report is subject to renewal February 2021.
www.icc-es.org i (800) 423-6587 i (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43—VentslFoundation Flood Vents
REPORT HOLDER:
SMART VENT PRODUCTS, INC.
EVALUATION SUBJECT:
SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540520; #1640521; #1540510; #1640511; #1540-
570;#1540-574;#1540524;#1540514
FLOOD VENT SEALING KIT#1540526
1.0 REPORT PURPOSE AND SCOPE
Purpose:
The purpose of this evaluation report supplement is to indicate that Smart Vent® Automatic Foundation Flood Vents,
recognized in ICC-ES master evaluation report ESR-2074, have also been evaluated for compliance with codes noted
below.
Applicable code edition:
■ 2016 California Building Code (CBC)
■ 2016 California Residential Code (CRC)
2.0 CONCLUSIONS
2.1 CBC:
The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.6 through 7.0 of the master evaluation report
ESR-2074, comply with 2016 CBC Chapter 12, provided the design and installation are in accordance with the 2015
lntemational Building Code (IBC) provisions noted in the master report and the additional requirements of CBC Chapters
12, 16 and 16A, as applicable.
The products recognized in this supplement have not been evaluated under CBC Chapter 7A for use in the eiderior design
and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any
Wildland-Urban Interface Fire Area.
2.2 CRC:
The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report
ESR-2074, comp with the 2016 CRC, provided the design and installation are in accordance with the 2015 International
Residential Code (IRC) provisions noted in the master report.
The products recognized in this supplement have not been evaluated under 2016 CRC Chapter R337, for use in the
exterior design and construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas
or any Wildland-Urban Interface Fire Area..
The products recognized in this supplement have not been evaluated for compliance with the International Wildland-Urban
Interface Code' .
This supplement expires concurrently with the master report, reissued February 2019.
7CGESEvaluarion Repomore notto be consvvedw represenffngamahetier orany othes atMbutesnorspecifically addressed, noramthey to be mnsnued
asanendorsementofihesubjeaofthereponorarecommendationforia=e.Tltexisnota mlybyfCCEvalwlion Se,Wm LLGespresaorimplied,ar 91
m aayfmdingor other nuarerin this repor4 or= io anyproduct covered by the report
Copyright O 2019 ICC Evaluation Service, LLC. All rights reserved. Page 4 of 5
ICC-ES Evaluation Report ESR-2074 FBC Supplement
Reissued -February 2019
This report is subject to renewal February 2021.
www.icc-es.org i (800) 423-6587 i (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
SMART VENT PRODUCTS, INC.
EVALUATION SUBJECT:
SMART VENT AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540520; #1540421; #1540510; #1540511;
#1540-570; #1540-674; #1540524; #1540514
FLOOD VENT SEALING IGT #1540526
1.0 REPORT PURPOSE AND SCOPE e
Purpose:
The purpose of this evaluation report supplement is to indicate that Smart Vane Automatic Foundation Flood Vents, recognized
in ICC-ES master report ESR-2074, have also been evaluated for compliance with the codes noted below.
Applicable code editions:
■ 2017 Florida Building Code —Building
■ 2017 Florida Building Code —Residential
2.0 CONCLUSIONS
The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the master evaluation report
ESR-2074, comply with the Florida Building Code —Building and the FRC, provided the design and installation are in
accordance with the 2015 International Building Code® provisions noted in the master report.
Use of the Smart Vent® Automatic Foundation Flood Vents has also been found to be in compliance with the High -Velocity
Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential.
For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report, reissued February 2019.
1CGESEvaluationRepor ore not to be comftedas representing acaftedw or any olherattrlbutes not specifically addressed, nor are they fo be construed c
m m endorsement oflhe sublw ofthe report or a remmmendafion foriu ma There is no warrantybylCCEv.1=lion Service, LLr-espress or implied, as
to anyfmdingor othermaner in dds report, oral to anyprodnct coveradby the report -
Copyright 0 20191CC Evaluation Service, LLC. All rights reserved. Page 5 of 5