HomeMy WebLinkAboutOUTSIDE AIR CALCULATIONI
Consulting
October 18, 2019 Art Kamm, PE, LEED AP CxA �-
Bradly Brown, PE, LEED AP
Lon T. Carter, P.E., LEED AP
Reply to: Fort Pierce Mike Pella, PE, LEED AP 1,
Gordon Scott
Plaza 1: Break the Bank Arcade
7173 S. US Hwy 1
Port St. Lucie, FL 34952
RE: Outside Air Calculation
St. Lucie County Permit # 1907-0705
To whom it may concern,
SCANNED
BY
St. Lucie County
Below is the outside air calculation provided,as requested for the above referenced project.
Space Data (from Architectural plans):
2262 sq.ft.
64 seats
Per 2017 Florida Building Code — Mechanical, 6t' edition Chapter 4, Ventilation; table 403.3.1.1
epodsandamasement
BeW q alleys (sealing areas)
0
10
0.12
—
OB dar etlo
100
20
0.W
—
Pfame
Thus:
2262 x 0.18 = 407.16 CFM
64 x 7.5 = 480.0 CFM
887.16 CFM of ventilation air.
If you have any questions or require additional information, please contact me directly.
Sincerely,
KAMM CONSULTING, INC.
John �Mayr, LEED AP, BD+C
Project Manager
954.448.0792
Florida:
1407 West Newport Center Drive
Deerfield Beach, Florida 33442
954-949-2200
954-949-2201 FAX
OFFICES
Florida: o,
1408 Orange Avenue
Fort Pierce, Florida 34950
772.595.1744
772.595.1745 FAX
www.kammconsulting.com