Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS,dl/ud lu: OZ rnx 817 222 8550 CARTER & BURGESS 0004 i St. Lucie County U45OR Building and Zoning Department S0,2300 Virginia AvenueFort Pierce, FL 34982 561.462-1553 Pum P pou5c— Design Certification for. Wind Load Compliance This Certification is to be completed by'the project design.architect or engineer. This Certification must be submitted with all applications for building permits involving the bonstruction'of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to inferior renovations (provided that no atructuial walls, columns or ottiei srnillar component is being effected) snd certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462.1553 o� 462-2172. Project Name W M Z De_ 92 Office Use Only Street Addiess "` oe F L to ¢N P i;;;;Le Permit Number - g. _-ursa - D-dE occupancy e Lc-t 1- D Pr�at� 'Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) l- Florida Building Code 2001 Edition - k ASCE 7-98 2. Building Design is (check one) Enclosed X Partially Enclosed Open Building 3. Building Height: 14 11 ° .4. Wind Speed Used in Building Design: 1 , 3 second gust 5. Wind Exposure CIassification (refer to exposure tables in Building Code identified in Line #1): ^ 6. Average Wind Velocity Pressure on Exterior Faces of Structure 204 Z PSF 1. PeakWind Velocity Pressure on. Exterior Faces of Structure PSF 8. Importance/Use Factor (obtain from Building Code): 9. Loads: Floor I-1/A PSF Roof/dead 3 PSF Roof/live 20 pSF 10.. Were Shear Walls' Considered for Structure (check one): Yes No X (if No, attach explanation) 11. Is a Continuous Load Path•Provided (check one): Yes X No (if No, attach'expianation) 12. Are Component and Cladding Detail Provided (check one): Yes No _0tNo, attach explanation) 13. Minimum Soil Bearing Pressure: Z S Qo PSF. As witnessed by my seal, I hereby certify that the information included with this certfecation is trite and correct, to the best of my knowledge and belief. Name: STnvc-tit M - �FfoM- -s Certification t 47., 19 [Sea] Nerel _ 1;MignFirm: PUTLEe Date: O-I- io SLCCDV Fproi 9 02^-(Jli �-z�o3 ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW 2400 Rhode Island Avenue Telephone: 772-462-8306 Ft Pierce, FL 34950 FAX: 772-462-8466 ( ew Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Jurisdiction: Occupancy: Address: Contractor Contractor's Address: State: Architect/Engineer: Building Owner: Occupancy Type: Gross sq ft: Occupant Load: Construction Type: SLC Walmart Distribution Fire Pump House 4001 S. Jenkins Rd. Unknown at this time Carter & Burgess, Inc. Wal-Mart Stores East Business F.P.B.: Building Dept: Number of stories: Phone # City: Zip Code: Phone # Review Date: Automatic sprinklers: 1,600 Net sq ft: Based On: SBCCI Type: B-03-101 23030447 817-222-8736 4/22/2003 IV unp NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 4. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. REVISIONS REQUIRED ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED( ) 1. A separate permit is required for the installation of the fire sprinkler and fire alarm systems. Monitoring is required. 2. Installation of the fire pumps require a separate permit. Reviewed by: -7- Date: 4/22/2003