HomeMy WebLinkAboutWINDOW REPLACEMENTSCHEMATIC PLAN
Y*NO
N40111 * :
A. LU
STATE OF :4
2019-08-14
OPENING "E" 5'X5' END ZONE
NOA 17-0411.08 PGT HR-5510
BUILDING PRESSURE +45/ -94 PSF
PRODUCT DESIGN PRESSURE +65/ -110 PSF
GLASS TPYE 10-12, 14-16
1/4" STEEL ULTRACON W/1j" EMBED, 1" EDGE DISTANCE
(5) EACH JAMB, 8" MAX FROM CORNER, THEN EQUALLY
SPACED
(8) AT HEAD AND SILL: 8" MAX FROM CORNER AT HEAD,
3" MAX AT SILL, (2) AT SASH SECTION, (2) AT FIXED
SECTION 12j"MAX OC, (4) CLUSTERED ® 4" OC CENTERED
ON MEETING RAIL
OPENING "C" AND "D" 4'X4'
FPA # 16736.1 PGT 8200 XO
BUILDING PRESSURE +46/-51
PRODUCT DESIGN PRESSURE +/-60 PSF
GLASS TYPE "A"
3/16" ITW TAPCON 6" MAX FROM CORNER AT HEAD, SILL,
JAMB, 121" OC MAX HEAD AND SILL, (4) ® 3" CENTERED
ON MEETING RAIL, 17" OC JAMB
OPENING "H" 6'X5'
FPA # 16736.1 PGT 8200 XO
BUILDING PRESSURE +44/-50
PRODUCT DESIGN PRESSURE +/-60 PSF
GLASS TYPE "A"
3/16" ITW TAPCON 6" MAX FROM CORNER AT HEAD, SILL,
JAMB, 121" OC MAX HEAD AND SILL, (4) @ 3" CENTERED
,N MEETING RAIL, 17" OC JAMB
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
FIDE COPY
SCANNED
BY
St. Lucie County
43,
WINDOW REPLACEMENT le
rAKLI=YI=NGINI=I=.KING,LLC
ACKER RESIDENCEI.
I'FANc FARLEY, PE 40111 GA 251�
3870 N. AtA UNIT 301 �As N.
R X565
FT. PIERCE FL Fii. 58y 6229 FAx 58�6229