HomeMy WebLinkAboutPRODUCT APPROVAL� r" A U1 �
Business & Professional Regulatioh
IN LQ
acrs;= I Lwm I Uww�� WtT. fi�A�Am
P" 5-b-lt5u�-Me SW�&F-� reCs,ff I ,,SSMMp j U.�
oduct Approval
d b" oo r 9 Do Pr ER: NbliC U� r,�, r Me- V—�
klyU=?
�ud Aoom�l Men" > �Ud 'r Aro�U�� S��Kh > ADDIUMOn I 1� > Applimton D�i
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Emall
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
AddresslPhone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048-116
Revision
2017
Approved
Lim
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.mlz@tribuiltmg.com
David Ruiz
david.ruiz@trJbuiltmg.com
SCANNED
BY
St. Lucie County
David Ruiz
250 Route 17 North
East Rutherford, Rl 07073
(201) 842-2449
david.mlz@tribuiltmaterlalsgmup.mm
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
C Evaluation Report - H,Tdcopy Received
Robert Nleminen
PE-59166
UL LLC
07/1812020
John W. KnezevlCh, PE
LV Validation Checklist - Hardoopy Received
EL1604a R6 COI 2017 01 COT N[gM[nen.pdf
Standard
Year
ASTM D1970
ASTM GISS
2015
2005
FM 4474
FRSA/-rRJ REVIEWED F
f
2011
2012
UL1897 COMPL
CODE IAI
2012
ST. LUCIE COUNTY
BOCqbv 0720`19
FILE COPY
https://www.floridabuilding.orgtpr/pi�_app_dtl-aspx?param--wGF wtD tF iND 1/12/2018
,VXQ q PmdY ...
FloTida Building Code Oji�" -
I
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
SummarV of Products
Method I Option D
09/2512017
10/01/2017
10/03/2017
12/12/2017
FL Ah
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen r,,r wderlayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
Approved for use outside HVHZ: Yes
H 2017 09 FINAL ER TRI-
Ki AYMEW5 FL16048-R6.pd
Impact Resistant; N/A
Design Pressurez +N/A/-150
ventieci 13y: RobertN!eminen PE-59166
Other., 1.) The design Pressure noted herein pertains be use
Created by Independent Third Party: Yes
Evaluation Reports
Of foam -on tile systems overtop the self-adhering
aFUL6k48 R6 AE 2Q17 09 FINAL ER TRI-
underlayment for one particular application See ER Section
BUILT UNULRLMENTS Fl 16048-R6.ncl
5.6.4 for details. 2.) Refer to ER Section 5 ir othe. U ....
�reavfu DY Independent Third Party: Yes
Use.
Q00"dU
EE FER
owe
�dd.et A m.. Adne,ds:
== R Him
mcs
aedn...�..�7.1395.lftisaart,a
he Depamnent wiin an emen addram if
re Rhin, moord. If Wu do not whih W
To dateradre if Wu am a 1hoon,na, We
https://www.floridabOding.org/pr/pi�__app _VXQwtDqtFF`mdYiND... 1/12/2018
_dt1.aspx?param=wGF
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT P13
OXFORD, Cr 06479
12031262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A42960.10.12-R6
PO Box 70 FL16048-R6
Rutherford, NJ 07070 Date of Issuance: 10/25/2012
(800) 516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (W17) Florida Building Code
sections noted herein.
DEsCRIPTION: TRI-BUILT Roof Underlayments
LAITEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT- The Evaluation Report number preceded by the words "rrinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEcrION, Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report Consists of pages I through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4 ANE1983
\JTPJNITYIERD
� fb.hge A �.6 b, �,
P-EmOns/2fiI7. �Isdmnw�mwane��a�!!V�C�d
�.�t
CERTIFICAMON OF INDEPENDENCE:
1. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not h . ave nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the appioval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
I. SCOPE:
Q\TRINITYIERD
Product Category: Roofing
Sub -Category: Underlaynnent
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6"' Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TR1 April 2012 (04-12)
2012
3. REFERENCES:
KQ!!_bf
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
b3/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44810.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD VST6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-RI
05/W2014
ERD (TST6049)
Physical Properties
S43530.05-14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC852o.b4.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045-05.17-RI
06/07/2017
LIL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC. (QUA9625)
QualityControl
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced,
sand -surfaced, SBS
modified bitumen
roof underlayment, with a 36-inch sheet width; meets ASTIVI D100.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced,
SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth
HT S/A Underlayment is a self
-adhering, glass -mat reinforced,
film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-116
CC,Vflwte of Authorizatlan #.9503 e EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILTRoof Underlayments; (800) 516-1485 Revision 6:09125/2017
Page 2 of 6
TRINITY I ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on. this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
..iTABLE 1:,RO COVER OPTIONS
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam -On ri le
Metal
Wood Shakes
Slate
a Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5,5.1
Yes
Yes
Yes
No I
No
aeF1
Yes
!__Y;D
5.5.1 "Foam -On Tile" is limited to use of the following Approved NIP adhpqivpc -, --ki-
-TABLE PL ALLOWABLE TILE Atimsivii UNDERLAYMEM COMEFINATIO NS
Adhesive
ilorida Product Appro A
Underlayments
I
ILP Acilresives PolysetO AH-160
FL6352
I Tri-Built S/A HT TU Underlayrnent -
DowTIIeBond-
FL22525
I Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Bullt Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment Or Tri-Built Smooth HT S/A
Underlayment applied to:
> Plywood; ASTM D41 primed plywood; OSB; ASTIVI D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered Adth plywood or
OSB prior to installationlof the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-11 SA Shingle Underlayment, Tri-Bullt S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
> Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with RIM 4474, Appendix D orTAS 114, AppendixJ.
I Refer to Tile Manufacturer's orAdhesiveManufacturers Florida PrOductApprovalfor Overturning Moment Resistance Performance.
Eictersor Research and Oesign, U.C.
Certificate ofAuthorkation #9SO3 6' EDITION (20173 FBC NON-HVHZ EVALUATION Evaluation Report A42960.10.12-116
FL16048-R6
TRI-BUILT Roof Underlayments, (800) 516-148s Revision 6:09/25/2017
Page 3 of 6
5.6.3 Bond to MechanicalIV Attached Base Laver: "\�TRINaYIERD
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
> ASTM D226, Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRJ April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSAITRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following Wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC ILSG4�9 has already been applied). Refer to FRSA/TRl April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 maximum DesignPressure=-45.0osf
Deck:
Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment:
Trl-Bullt S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure= -67.5 ps
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Soprema Elastocol 600c
Underlayment:
Trl-Bullt S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure= -15OLD
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
.Deck Preparation: Plywood shall he thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure= -60.0 psf.,
Deck:
Min. 19/327inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction. -
Base Sheet:
Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-ifich laps and 6-inch o.c. in three
equally spaced rows in the center of the sheet.
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design,LLC. Evaluatian Report A42960.10.22-R6
Certli'lcate of Authorization #9503 6rxEDInON (2017) FBCNON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments, (800) 51r,1485 Revision 6:09/25/2017
Page 4 of 6
'\�TRINITYJERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSAITRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone I
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/5PRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2616) for Zone 2/3 enhancements.
5.7 Exposure Limitations,
Tri-Bullt Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longerthan 311-clays after installation
Tri-Built S/A HTTIJ Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations LrAS 103 Per FRSAITRI April 2012 (04-12)):
When loading roof tiles on the underlayment in,direct-deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TIOSLI�PAGE.IjlvnrAnONSFOR�
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. IG-tile stack
-
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
"A
- F-4 . i
Tr -'-Built S/A HTTU
Underlayment
Lugged
Exterior Research and Design, LLr— Evaluation Report A42960.10.12-Rfi
Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL26048.R6
TRI-BUILT Roof Underlaryments, (800) Sir,1485 Revision 6: 09/25/2017
Page 5 of 6
r_��
S. INSTALLATION: \ ",�TRINITYJERD
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the 1-imitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment. Tri-Built S/A HT TU UnderlaVolent or Tri-Built Smooth HT S/A
Underlayment,
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -rile applications:
While priming is optional, TRI-BUILT Materials Group, ULC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 fit of membrane and peel back the first 3
fit of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group,LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, ILLC recommends back -nailing in the
overlap area at thetop of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04712).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
B. MANUFAcrURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406, k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-116
Certf7wte of Authorization #9503 eEDITION (2017) FBCNON-HVHZ EVALUATION FL16048.Rfi
TRI-BUILT Roof Underlayments, (800) 516-14&5 Revision 6: 091ZS/Z017
Page 6 of 6
'Flofida Building Code Onlint
Page 1 of 4
Iff
Business & Professionpl Regulation
fir
BUS t �g 1. 1 Uwr "!�St�n �!,TOPIO �bmltSu�aMe SWMIkFaM ftbilt.M FBC Soo I BCIS Slie M-P
Product Approval
�Puiij�u.'
Ayp�l Me,,U 01 Mll�b� ArOaWn LIA > APPIIWUM D"I I
FL # FL14645-R3
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived F1
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 54S South 3rd Street, Suite 200
Louisville, KY 40202
(502) 855-4300
dstemer@metaisai�.us.com
Authorized Signature David Stemner
dstenmer@meta1sales.uS.COm
Technical Representative
Address/Phone/Emafl -SCANNED
BY
Quality Assurance Representative
Address/Phone/Emali St. Lucie County
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
:j Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifimbons, Inc.
Quality Ass�urance Contract Expiration Date 12/27/2026
Validated By Yoosef Lavi, P.E.
96 Validation Checidist - Hardcopy Received
Certifimbe of Independence FL14645 R3 COI Certifi�telndependencexdf 'ii�
Referenced Standard and Year (of Standard) Standard
FM 4470
TAS 125
UL 1897
UL SBO
Equivalence of Product Standards
Certined By
Sections from the Code
cot)f lUU1'jHIi'- litAl"I
ST. LUG%e4o
1300C
(;Opl
0 7' ZO
https://www.floridabuilding.org(prlp�_app_dtl.aspx?param=wGEVXQwtDqsw8ZVNfe8A... 1/12/2018
ProduCtApproval Method Method I Option D
Date Submitted 09/09/2017
Date Validated 09/14/2017
Date Pending FBC Approval 09/1512017
Date Approved 12/12/2017
ummary a roductes
FIL * I
Model, Number or Name
De,scription
14645.1
2.5' Corrugated
Min. 26 ga., 21.33- wide coverage through fastened roof
I
panel over min. 19/32" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: NO
Fl 14645 R3 II EvalliglignRenortC21132 1.12A
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party; Yes
Design Pressure: +NIAI-66.0
Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36' o.c.
FL14645 R3 AE EvatuationReportC2182 I.Odf
and 86.0 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.2
SV-Crimp
Min. 26 ga., 24 wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel flat
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F1 14645 R3 II F—valualignReportC2182 2.nd
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingarn PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure; +N/A/-149.6
Evaluation Reports
Other: Uplift load of 84.5 psf at rastener spacing of 24"
FL14645 R3 AE EvalualignReportC2182 2.uff
o.c., 131.3 psf at fastener spacing of 18" o.c. and 149.6 psf
Created by Independent Third Party: Yes
at fastener spacing of 12" o.c.
14645.3
SV-Crimp
Min. 26 ga., 24' wide through fastened mof panel over min.
19/32" thick plywood deck with fasteners through panel rib.
Limits of Use
Installation Instructions
Approved for Use in HVHZ: No
Fl 14645 R3 11 EvalualignReportC2182 3,12d
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingarin PE 62240
Impact Resistant: N/A
Created by Independent Third Parly: Yes
Design Pressure: +N/A/-196.75
Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing or 36"
FL14645 g3 AE FxaluptignReportC2182 3,pd
O.c., 74.8 psAdastener spacing of 16" o.c. and 196.75 psf
Created by Independent Third Party: Yes
It fa5twierspacing of 8' o.c.
14645.4
Min. 26 ga., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16' thick OSB with fasteners
through panel rib.
Li
Installation Instructions
Approved for use in HVHZ: No
F1 14645 R3 11 EvaluatignReportC2182 4.9d
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c.
FL'4645 R3 AF EvgluaUgnReOortC?I82 4,odf
and 172:5 psf at fastener spacing of 6" o.c
Created by Independent Third Party: Yes
14645.5
Rib
Nom. 0.032" thick, 36" wide, aluminum through fastened
roof panel over min. 15/32" thick plywood deck or 7/16"
thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
R 14645 R3 11 EvaluglignRepo C2182 5odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingarn PE 622.40
Impact Resistant- N/A
Created by Independent Third Party: Yes
Design Pressurei +N/Al-120
Evaluation Reports
Other: Uplift load of 30 pSf at fastener spacing of 36' o.c.
FL14645 R3 6E EvalWaMongeportC2182 S.gdf
and 120 psf at fastener spacing of 6' o.c.
Created by Independent Third Party: Yes
14645.6
Aluminum Vertical Seam
Nom. 0.032" thick, 16" wide, aluminum standing seam roof
panel over min. 15/32' thick plywood deck or 7/16' thick
OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
F1.14645 R3 11 EvaltiationReportC2182 6.12d
Verified By: Bala Sockalingam PE 6224U
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure; +N/Al-97.05
Evaluation Reports
Other: Uplift load of 41.6 psf at dip spacing of 36" o.c.,
Fl 14645 R3 AE EvalugtjorilleportC2182 6.pgf
71.0 psf at dip spacing of 12" o.� and 97.1 psf at clip
Created by Independent Third Party: Yes
soacina of 12' o.c. with sidelap adhesive.
https://www.floridabuilding.orglprlpr�_app_Atl.aspx?param=wOEVXQwtDqsw8ZVNfe8A... 1/12/2018
I
'Florida Building Code Onlim,
Page 3 of 4
1464S.7
minum Vertical Seam
Nam. 0.032" thick, 16" wide, aluminum standing searn roof
panel over min. 19132" thick plywood deck
Limits Of USa
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 11 EvaluationRaportC2182 7.2d
Approved for use outside HVHZ: Yes
Verified BY: Bala Sockalingarn PE 62240
Impact Resistant., N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-162.0
Evaluation Reports
Other: Uplift load of 41;6 psf at clip spacing of 36" o.c.,
FL14645 R3 AE Evaluation2goortC7182 7.RdF
100.2 psf at dip spacing of 12- o.c. and 162.0 psf at dip
Created by Independent Third Party; Yes
spacing of 12" o.c. with Support Strap.
1464S.8
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
15/32- thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Fl 14645 R3 11 EvaluatlanRevortC2 82 8.00
Approved for use outside HVHZ! Yes
Venfled BY: Bala Sockalingam PF 62240
impact Resistant. NIA
Created by Independent Third Party: Yes
Design Pressure: +NIAI-91
Evaluation Reports
Other: Uplift load of 41.5 psf at fastenerspacing of 48' O.C.
EL14645 P.3 AE EvatuatignReportC2182 B.Odf
and 91 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.9 Classic Rib
Min. 26 ga., 36" wide through fastened roof panel over min.
1
19132" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use In HVHZ; No
FL14645 R3 if EvaluptionReportC7182 2.pd
Approved for use outside HVHZ: Yes
Verified By: Bala Sockatingam PE 62Z40
Impact Resistant: NIA
Created by Independent Third Party: Yes
Design Pje,ssure: +N/A/-133.9
Evaluation Reports
Other; Uplift load of 74.8 psf at fastener spacing of 36"
F1 14645 R3 AE Evalua!jgnReportC2182 9.2Ilf
o.c., 92.3 psf at fastener spacing of 24" o.c. and 133.9 psf
Created by Independent Third Party: Yes
at fastener spacing of 18" a.c.
14645.10
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
1
7/16" thick OSB deck
Limits of Use
Installation Instructions
Approved for use in HVHZi No
FL14645 R3 11 EvaTUatjgnReoortC2I82 10jA
Approved for use outside HVHZ: Yes
Verified By: Bala Sockallngam,PE 6ZZ4U
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure! +N/A/-135.0
Evaluation Reports
Other: Uplift load of 45 psF at fastener spacing of 24" o.c.
FL14645 R3 AE EvaluationReportC2182 10-pdf
and 135 psf at fastener spacing of 6" o.c%
Created by Independent Third Party: Yes
14645.11
Classic Rib
Min. 29 go., 36' wide through fastened roof panel over min.
15/32" thick plywood deck.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R3 11 EvaluationReportC 187. ll.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PF 6224U
Impact Resistant: NJA
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.5
Evaluation Reports
Other: Uplift load of 68.4 psf at fastener spacing of 24� o.c.
FU4645 R3 AE EvaluationReportC2182 11.Ddf
and 138.5 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.12
Min. 26 ga., 16" wide concealed fastened roof panel over
min. IS/32" thick plywood deck or 7/16" thTck OSB.
Limits of -Use
Installation instructions
Approved for use in HvHZ: No
FL14645 R3 II EvaluallonReportC 182 12.vdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant; N/A
Created by Independent Third Party; Yes
Design Pressure: +N/Af-86.55
Evaluation Reports
Other: Uplift load of 20.8 psf at fastener spacing of 24"
F1 14645 R3 AE EvalugtionReportC2182 17.pdf
o.c., 63.5 psf at fastener spacing of 6" o.� and 86.55 psf at
Created by Independent Thlrd Party: Yes
fastener spacing of 6" o.c. with sidelap adhesive.
14645.13
PBR-Panel or R-Panel
Min. 26 ga., 36' wide through fastened roof panel over min.
1
15/32" thick plywood tied<.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14- - R3 I EvaluationReportC2182 13.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-131.0
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48' o.c.
F-1.14645 R.3 6E EvoluationRepo 2182 13.pdf
and 131.0 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.14
Pro -Panel 11
Min. 29 ga., 36' wide through fastened roof p
15132" thick plywood deck.
i
I
https://www.floridabuilding-orglprlpii-_app__4ti.aspx?pararn=wGEVXQwtDqsW8zVNfe8A... 1/12/1018
Fl6rida Building Code Onlini, -
Page 4 of 4
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Presaaare: +N/A/-71.5
Other: Uplift load of 41.6 psf at fastener spacing of 24' o.c.
and 71.5 psF at fastener spadng of 12" o.c.
Installation instructions
E=jjfij5. R3 I �Eva U lonliteportC21§2 14.pdf
Verified BY: Bala Sockalingann PE 62240
Created by Independent Third Party: Yes
F--1 FM�iq
Qrhart Us:: �Qn BlalrStoneRgad.Tallahosdat"23"Phone' SR�187-282
The Slamof Morldah, an AVlM0empTou.QrLydaht2M7-202 scam of Mrida. ArcmSJJNriWSmW"crt;; Renard Srabemnn
nderM Me law, emu ackirmes ampbhcrhaama� Ifyau do natowntmare-rawn addrearynileaced in reepapsato a puly �mcar!S Mond. do notsend
-Plecuarth,
chen]c mil 0 bible crazy. ImMud, comm, ine office by ph... or by,bradliforal ms. U yea hanne any parbom, plenme mn.d 850.Q7.L395.
on 45S.275(i), FTorda Matters, � OcIvaer 1, 2012, licanewaa named under �plxur 455. F.S. mp� pmAde the Deparinnent own an ennall addraSS if
y have one. 'rbe enwilb; pwided my le med far official cammalcabon whirl the fihx� Momyer emil addresses am public mcom. If you do nat �ahh to
.—H... � I.. To d�wwrnm if �u am . licensee under
product Approwl Acceplau
M.0 ON 9R ER M
Credit Card
Safe
https:llwww.floridabuild-ing*orglprlpi�_app--dtl.aspx?param=wGEVXQwtDqsw8ZVNfe8A... 1/12/2018
EVALUATION REPORT OF
M,ETAL SALES MANUFACTURING CORPORATION
'26 GA. 5V-CRE%IP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 311 Street� Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingarn, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover) %001111111111110
Installation Details (1 Page) %% sOGKAQ1v I.,
Load Span Table (1 Page)
No 62240
4Q
,01 STATE OF UJZ
Report No. C2182-4 0%
XN -'N
Date: 0.9.17 4,�- Q),
Pl- % %%%
Fl, 14645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or min. '/4" thick
wood plank (min SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5. 1.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 30.0 psf @fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: 99-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 611 o.c. across panel width
At intermediate @ 1211 o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 'Uplift Resistance
of Roof Assemblies' & UL1897-04 'Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
for fire ratings of this product.
Supporting Documents: —�580 & 1897 Test Reports
PRI Construction Materials Technologies
MSMC-O 17-02-0 1, Reporting Date 9/20/13
FL 14645.4-R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
PANEL OVERLAP
CRIMP SEE DETAlL 1 FASTENER AT PANEL FLAT
DETAIL 2 REQUIRED FOR PANEL
7� jr ENDS ONLY. � At op
#9-16 OR #10-14 WOODSCREWS
WITH SU SEALING WASHER AT
MAXIMUM SPACING OF 36" D.C.
MINIMUM ATTACHMENT:
8d x 2.5" LONG RING SHANK NAIL
UNDERLAYMENT SHALL BE INSTALLED OR 18 , 2' LONG WOOD SCREWS
AS PER MANUFACTURER'S INSTALLATION SPACED 0 6* O.C. IN THE FIELD
GUIDELINES & AT EDGES
MIN. 2X WOOD RAFTER/JOIST/
TRUSS TT MAX. 24" O.C.
TYPICAL PANEL INSTALLATION X-SECTION
5V MP
MI�CRI
26 GA.
PANEL FASTENER PER UPLIFT
LOAD TABLE
GFNERAI NOTES: E WITH THE
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANC
FLORIDA BUILDING CODE FRC).
2. ROOF PANELS SHALL BE %IN. 26 GA, (I � 0.019). EFFECTIVE COVERING
4DERLAYMIENT
DETAIL 1
CSB 7/16' THICK (MIN.) OR
PLYWOOD 15/32" THICK (MIN.)
WIDTH OF PANEL - 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
ON THIS DRAWING.
y
SPECIFIED 7141S
4. REQUIRED DESIGN WIND LOADS SHALL 13E DETERMINED FOR EACH PROJECT
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
16 OR J10-14 WOODSCREWS
WN SELF SEALING WASHER AT
ARE GREATER 114AN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING,
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THI& DRAWING & THE FLORIDA
THE MINIMUM
MAXIMUM SPACING OF 36" D.C.
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
B. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
5V-CRIMP
F MIN 26 GA-
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
\-OSB 7/16" THICK (MIN.) OR
DETAIL 2 PLYWOOD 15/32" THICK (MIN.)
METAL SALES MANUFACTURING CORPORATION
5V-Crimp Uplift Loads
(Min. 26 ga.)
Description
Fastener Spacing
along panel length
(in)
Allowable Uplift
Load
(Psf)
Coverage width: 24"
Panel Fasteners
#9-16 or #10-14 hex head
wood screws with sealed
washer
6
172.5
9
120.0
�9CFP
42'�
15
72.0
18
60.0
21
51.4
24
45.0
27
40.0
30
36.0
33
32.7
36
30.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current iastallation procedure.
3. Three or more spans condition.
CKAZ'
%%
No 62240
:rc
53,
0* STATE OF
0 V
N
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
9184925992
Bala Sockaling-am, Ph.D., P.E.
FL 62240