HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY St. Lucie County NEMO I etc. Certificate ofAuthorization #32455 353 Christian Street, Unit H13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT CertainTeed Corporation REVIEWED �-OR Evaluation Report 3520.03.04-R24 20 Moores Road FI-2533-R23 Malvern, PA 19355 CODE COMP�- ANCE Date of Issuance: 09/19/2005 (610) 651-5847 ST. LUCIE CUUNTY Revision 24:06/20/2019 SCOPE: 0qO^d' This Evaluation Report is issued under Rule 61132 - an?t'ee applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: FlintlasticO Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it Shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 67-page Appendix. Prepared by: FILE -OPY Robert J.M. Nieminen, P.E. % The facsimile seat appearingwas authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Niernmen, PE. on 061 This does not serve as an Z-' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated ourcontrolled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nienninen, P.E. does not have, norwill acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEM01 etc. nor Robert Nierninen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: FlintlasticO Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11�2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 REFERENCES: ERDY. Examination Reference Date ERD (TST6049) FM 4470 3504.06.01-1 06/0512001 ERD (TST6049) Fly 4470 3513.08.02 08/15/2002 ERD (TST6049) Fly 4470 03515.07.03 07/22/2003 ERD (TST6049) Fly 4470 3519.12.03 12/22/2003 ERD (TST6049) FM 4470/4474 3522.07.04 07/28/20G4 ERD (TST6D49) FM 4470/4474 0284102.05-11 02/10/2005 ERD (TST6049) FM 4470/4474 3533.01.06 01/06/2006 ERD (TST6049) FM "70/"74 4674.11.01-1 03/21/2006 ERD (TST6049) Physical Properties 3535.10.06 10/31/2006 ERD (TST6049) FM 4470/4474 3521.07.G4-Rl 10/26/2007 ERD (TST6049) Fly 4470/4474 02764.09.05-Rl 12/10/2007 ERD (TST6049) FM 4470/4474 02762.03.05-RI 12/10/2007 ERD (TST6049) Physical Propenies C7290.01.08 01/16/20UB ERD (TST6049) Physical Properties C10080.09,08 09/04/2008 ERD (TST6049) FM �70/4474 C8370.08.08-RI 10/05/2009 ERD (TST6049) FM 4470/4474 P6860.06.07-RI 09/10/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 C31420.08.10 09/21/2010 ERD (TST6049) FM 447G/4474 C33980.12.10 12/22/2010 ERD (TST6049) FM 4470/4474 C33830.02.11 02108/2011 ERD(TST6049) TAS 117(B), Rupture C35500.02.11 02109/2011 ERD (TST6049) FM "70/4474 07820�07.12 0712412U12 ERD (TST6049) FM 4470/4474 C37830,07.12 07/26/2012 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C39670.08.12 08/20/2012 ERD (TST6D49) Fly 4470/4474 C42280.08.12 08/20/2012 ERD (TST6049) TAS 117(A) A35880.04.12-Rl 10/26/2012 ERD (TST6049) FM 4470/4474 C44580.07.13 07/25/2013 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470/4474 C45620,03.14 03/27/2014 ERD (TST6049) FM 4470/4474 C46760.06.14 06/19/2014 ERD (TST6049) FM 4470/4474 C47320.03.14-111 04/01/2015 ERO (TST6049) FM 4470/4474 CTR-SCE995.10.15 10/14/2015 ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01/14/2016 ERD (TST6049) FM 4470 CTR-SC9920.01.16-111 01/20/2016 ERD (TST6D49) FM 4470/"74 CTR-SCID420.01.16 01/25/2016 ERD (TST6049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016 ERD (TST6D49) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016 ERD (TST6049) FM 4470/4474 CTR-KlIS90.09.16-111 09/06/2016 NEMO ETC, LLC Evaluation Report 3520.03.134-IR24 Cenificate OfAuthorizotion #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL2533-R23 CertainTeed Flintlastic- Modified Bitumen Roof Systems; 1610) 651-5847 Revision 24: 06/20/2019 Page 2 of 6 NNEMOjetc. En� Examination Reference Date ERD (TST6049) I'M 4470/4474 CTR-SC12255.12.16 12/27/2016 ERD (TST6049) Criticality ICP-SC15630.09.17 09/0612017 ERD (TST6049) Criticality 1CP-SC16225.09A7 09/06/2017 ERD (TST6049) FM 4474 CRT-SC15775.17 09/13/2017 FM Approvals (TST1867) FM "70 OE3A2.AM 03/30/1982 FM Approvals (TST1867) FM 4470 3WOA4.AM 03/16/1993 FM Approvals (TSTIE67) FM 4470 3WOA2.AM 03117/1993 FM Approvals (TST1867) FM 4470 3WDA3.AM 03/17/1993 FM Approvals (T5TIS67) FM 4470 IZ4A6.AM 09111/1996 I'M Approvals (TSTIE67) FM 4470 3Y8AI.AM 09/30/1996 FM Approvals (TST1867) Flyl 4470 2D5A9.AlA 06/22/1999 FM Approvals (TST1867) FM 4470 3009502 12/12/2000 FM Approvals (TST1867) FM 4470 3008869 03/19/2001 FM Approvals (TST1867) FM 4470 3009610 10/1512001 FM Approvals (TST1867) FM "70 3006025 12/28/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3009814 09/06/2002 FM Approvals (TST1867) FM 4470 3014502 04/04/2003 FM Approvals (TST1867) FM 4470 3015444 07/11/2003 FM Approvals (TST1867) FM "70 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3018579 10109/2003 FM Approvals (TST1867) FM "70/4474 3020703 07/30/2004 FM Approvals (TST1867) FIVI 4470/4474 3021759 06/03/2005 FM Approvals (TST1667) FIA 4470/4474 3022038 0410SY2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals iTST1867) FM "70/4474 3026128 08/04/2006 FM Approvals (TST1867) FM 4470/4474 3024311 11/01/2006 FM Approvals (TST1867) FM 4470/4474 3025766 11/13/2006 FM Approvals (TST1867) FM 4470/4474 3028410 02/19/2007 FN4 Approvals (TST1867) FM 4470/4474 3026964 07/25/2007 FM Approvals (TST1867) FM 4470/4474 3031262 11/30/2007 FM Approvals (TST1867) FM 4470/4474 3031199 12/23/2008 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3037127 01/11/2010 FM Approvals (TST18671 FM 4470/4474 3039848 12/02/2011 FM Approvals (TST1867) FM 4470/4474 3046104 08/13/2013 FM Approvals (TST1867) FM 4470/4474 3048520 09/19/2013 FM Approvals (TST1867) FM 447014474 305S491 12/0512016 FM Approvals (TST1867) FM 4470/4474 3063970 09/14/2018 MTJ (TST2508) Physical properties DX08C4A 03/22/2004 MTl (TST2508) Physical properties DX2OE3A 03122/2004 MTl (TST2508) Physical properties DX2GE3A-001 01/134/2006 MT] (TST2508) Physical properties AX31GSA 08/21/2008 MTl (TST2508) Physical properties AX31G8D 09/05/2009 MTI (TST2508) Physical properties AX31GEF 06/05/2009 MTI (TST2508) Physical properties AX21GSC 01/28/2011 NEW (T5T6049) FM 4474 4L-CTR-18-002.09.18-1; CTR-Cl, C2 09/21/2018 NEMD (TST6049) FM4474 4L-CTR-28-002.09.18-2; CTR-C3 09/21/2018 NEMO (TST6049) FM 4474 4L-CTR-18-002.10.18; CTR-A1, A2, C4 10/22/2018 NEMO (TST6049) FM 4474 4L-CTR-18-002.03.19A; CTR-05 TO CS 03/07/2019 NEMO (TST6049) FM 4474 4L-CTR-18-002.04.19B; CTR-C11 04/12/2019 NEMO (TST6049) FM 4474 2L-CTR-19-001; CTR-C9 & CTR-CIO 04117/2019 PRI (TST5878) Physical Properties CTC-032-02-01 0111612008 PRI (TSTS878) Physical Properties CTC-G34-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5978) Physical Properties CTC-068-02-01 08108/2011 PRI (TST5878) Physical Properties CTC-07G-02-01 08/08/2011 PRI (TSTS878) Physical Properties CTC-071-02-01 08/08/2011 PKI (TST5978) Physical Properties CTC-093-02-01 08108/2011 PRI iTST5878) Physical Properties CTC-116-02-01 04103/2012 PRI (TSTS878) Physical Properties CTC-183-02-01 10/04/2013 PRI (TST5879) Physical Properties CTC-259-02-01 12/11/2015 ILL, LLC. (QUA9625) Quality Assurance Service Confirmation, R11656 03/09/2017 NEMO ETC, LLC Evaluation Report 3S20.03.04-RZ4 Certificate ofAuthofizotion #32455 6"EDITION (2027) FBC NON-HVHZ EVALUATION FL2533-R23 CertainTeed Flintlastic' Modified Bitumen Roof Systems; 1620) 651-5847 Revision 24: 06/20/2019 Page 3 of 6 NNEMOIetc. This Evaluation Report covers FlintlasticO Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. TABLE TYPE 1: ROLL-GoODS FOR FLINTLASTIC* MODIFIED BITUMEN ROOF SYSTEMS PRODUCT SPECIFICATION REFERENCE GRADE TYPE Base Sheets FlintlasticO SA NaiIBase ASTM D4601 N/A 11 Glasbase'm Base Sheet ASTM D4601 N/A 11 All Weather/Empire T" Base ASTM D4601 N/A 11 Flexiglas'" Base ASTM D4601 N/A 11 FlintlaStiCTM Base 20 ASTM D4601 N/A 11 Flintlastic Poly SMS Base Sheet ASTM D4601 N/A 11 YosemiteO Venting Base ASTM D4897 N/A I fl Ply Sheets FlintglasO Ply 4 ASTM D2178 N/A IV FlintglasO Premium Ply 6 ASTM D2178 N/A VI Base/Ply Membranes (APP) Flintlastic- APP Base T ASTM D6509 N/A N/A Flintlasti0 STA ASTM D6222 5 1 FlintlasticO STA Plus ASTM D6222 S I Cap Membranes (APP) FlintlasticO STA ASTM D6222 S I Flintlastic- STA Plus ASTIVI D6222 S I Flintlastics GTA ASTM D6222 G I Flintlastica GTA CoolStar— ASTM D6222 G I FlintlasticO GTA-FR ASTM D6222 G I FlintlasticO GTA-FR CoolStu- ASTM D6222 G I Base/Ply Membranes (SBS) Flintlastic' SA PlyBase ASTIVI D1970 NIA N/A Black Diamond- Base Sheet ASTIVI D3.970 N/A N/A Flintlastic* SA Mid Ply ASTIVI D6163 S I Flintlastic* Ultra Glass SA ASTIVI D6163 S I Flintlastic' Base 20 ASTM D6163 S I Flintlastic' Base 20 T ASTM D6163 S I Flintlastic* Ultra Poly SMS Base Sheet ASTM D6164 S I Cap Membranes (SBS) Flintlastic' FR Dual Cap ASTM D6162 G I Flintlastic* SA Cap FR ASTM D6163 G I Flintlastic' SA Cap FR CoolStarTm ASTM D6163 G I Flintlastic* FR Cap 30 ASTM D6163 G I Flintlastic' FR Cap 30 CoolStaff ASTM D6163 G I Flintlastic' FR Cap 30 T ASTIVI D6163 G I Flintlastic* FR Cap 30 T CoolStar— ASTM D6163 G I Flintlastic* SA Cap ASTIVI D6164 G I Flintlastic' SA Cap CoolStarT' ASTM D6164 G I Flintlastic' FR-P ASTIVI D6164 G 11 Flintla5tic* FR-P CoolStar� ASTM D6164 G I Flintlastic* GIVIS ASTM D6164 G I Flintlastic' GM5 CoolStaff ASTM D6164 G I Flintia5tic' GTS-FR ASTM D6164 G 11 Flintlastic* GTS-FR CoolStar" D6 G 11 2 Pr2mium FR-P ASTM 164 G H 22� n!!,,!t!�c: Prmiurn FR-P CoolStar" ASTM D6164 G 11 NEMO ETC, LUC Evaluation Report 3S20.03.04-RZ4 Certift.W of Auth.,hotio. #3245S rEDITION (2017) FBC NON-HVHZ EVALUATION FL2S33-R23 Certainreed FlintlaStic- Modified Bitumen Roof Systems; (610) 651-S847 Revision 24: 06/20/2019 Page 4 of 6 ONEMOletc. 5.1 This is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 This Evaluation Report does not purport to address codified fire requirements. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FEIC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure.criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with F8C Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANISI/SPRJ IA-1, ASTM E907, FIVI Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(l), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 Cenoficate ofAuthotization #32455 eEDITION (2017) FRC NON-HVHZ EVAWATION F1.2533-1123 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 651-5847 Revision 24: 06/20/2019 Page 5 of 6 ON EMO I etc. 6.1 FlintlasticO Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP"= Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: LI L, LLC. — QLA9625; (414) 248-6409, karen.buchmann@ us.ul.com THE 67-PAGES THATFOLLOW FORM PART OF THIS EVALUATION REPORT- NEMO ETC, LLC Evaluation Report 3520.03.134-R24 certificate ofAuthon2ation #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FLZS33-R23 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 6S1-S847 Revision 24: 06/20/2019 Page 6 of 6 ONEMID I etc. APPENDIX 1:ATTAOHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-8 1C Wood New, Rerocif (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10-11 1E Wood New, Reroof (Tear -Off) or Recover D Insulated, Mach. Attached Base Sheet, Bonded Roof Cover 12-14 117-1 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15-17 IF-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18-19 0 M. 17M. �71-7_0-�w @_ N 3-OLCove ED 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech, Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 20-22 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mach. Attached Insulation, Bonded Roof Cover 23-27 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Insulated, Much. Attached Base Sheet, Bonded Roof Cover 28-30 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 31-38 3B Structural concrete New or Reroof (Tear -Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 38 3C Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 39 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 40-43 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 44-46 4C Lightweight concrete New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47-52 4D Lightweight concrete Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 52 5A Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded RoofCover 53 so Cementitious wood fiber New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded RoofCover 54 5C Cernentitious wood fiber New, Reroof (Tear -OR) or Recover C Mach. Attached Insulation, Bonded RoofCover SS SO Cementitious wood fiber New, Renoof (Tear -Off) E Non -Insulated, Mach. Attached Base Sheet, Bonded Roof Cover 55 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 56-58 6B Existing gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 58-59 ISC Existing gypsum Reroof (Tear -Off) C Mech. Attached Insulation, Bonded Roof Cover 59 ED Existing gypsum Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation, Bonded RoofCover 61-67_ 7B Various Recover F Non -Insulated, Bonded Roof Cover 67 NEMO ETC, LUC Evaluation Report 3520.03.04-R24 for F1.2533-1123 Certificate of Authorization U32455 6"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/20/2019 Prepared by: Robert Niernmen, PE-59166 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 651-5947 Appendix 1, Page 1 of 67 NNEMOjetc. The following notes apply to the systems outlined herein. " 7 , `TC rRrils s- va rtam to�oove4d 'T 5 3-atiar,'hereln7 MT753f, djk7baf ;pff;e,;"Qs;R-w7dMcks shallibe in titicordance7ivitni F 7requlremenisfo iffe 55tiifm� iFfic"EM17a 4 amp IV W, C; �5C A R, "'me 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: • Wood Deck: OMG #14 Roolgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Eakfast #14 with Hex Plate or 3" Round Insulation Plate, Trufast HID with Trufast 3" Metal Insulation Plates or FIIntFa5t #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. • Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HID with ONG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3" Round Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast H12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast 414 or DekSpIke with Hex Plate or 3" Round Insulation Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates, Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board orgypsum-based roof board that meets the CA requirements of F.A.C. Rule 61620-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-Inch thick lightweight insulating concrete may be substituted for, or installed beneath rigid insulation board for System Type D (mechanically attached base sheet, handed roof cover), whereby the base sheet screws and plates are installed through the UNIC to engage the structural steel or concrete deck. The structural deck shall be of equal argreater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance ofthe roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FIVI Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions > Hot asphalt (HA); Full coverage at 25-30 b51'square > Ashland Pliodeck (A-PD); Continuous 0.75 inch wide ribbons, 12,inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the foyer below. > Dow I NSTA-STIK Qulk Set insulation Adhesive (D-IS): Continuous 0.75 to I inch wide ribbons, 12-inch o.c. > ICP Adhesives Polyset BOARD -MAX: Continuous 3-inch ribbons, 12-inch o.c. > ICP Adhesives Polyset CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. ), Millennium One Step Foarnable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. > Millennium PG-1 Pump Grade Adhesive (M-PG1); Continuous 0.5 to 0.75-inch wide ribbons, 12�inch o.c. > OMG OiyBand 500 or OIyBDnd Green (OR500): Continuous 0.75-inch wide ribbons, 12-inch o,c, (PaceCart or SpotShot) Note: When multiple layers(s) ofinsulodon andlor coverboard are installed in ribbon -applied adhesive, boards shall be staggeredfrom layer-to-loyer. > Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase'the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: • Ashland Pliodeck (A-PD) @ 12Anch o.c. MDP -105.0 psi (Min. 1.0-inch) • Ashland Pliodeck (A-PD) @ 6-mch o.c. MDP -277.5 psf (Min. 1.0-inch) • Dow INSTA-STIK Quk Set Insulation Adhesive (D-15): MDP -120D psf (Min. 1.0-inch) • ICP Adhesives Polyset CR-20: MDP -117.5 psf (Min. 1.0-inch) • Millennium One Step Foarnable Adhesive (M-OSFA): MDP -157.5 psf (Min. 1.0-inch) • Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 1.0-inch) • OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi -Max FA3) • OMG O[yBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL) • OMG OlyBond 500 (013500)� MDP -315.0 psf (Min. 0.5-inch ENRGY3) • ONIG OlyBond 500 (OB500); MDP -487.5 psf (Min. 0.5-inch ACFoann 11) NEMO ETC, U-C Evaluation Report 3520.03.04-R24 for F1.2533-1123 Certificate ofAuthorization #32455 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/20/2019 Prepared by: Robert Klieminen, PE-59166 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 2 ofn ONEMOletc. 8. Bonded polyisocyanurateinsulation boards shall be maximum 4x4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonlyused methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum require me nts for the system. Testing and analysis shall be in accordance with ANSI/SPR I FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, I'M Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Concrete Deck or Recover Applications using System Type D, the insulation is optional. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Unless otherwise noted, use ofthese fistings in new construction or re -roof (tear -off) applications is at the discretion of the Designer of Record and Authority Having Jurisdiction. 10 Q_Me—ss o-treWl Mel �93=1111092=_ REFERENCE LAYER MATERIAL APPLICATION BP -AA (Base and Ply sheets, Asphalt -Applied) Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Hot asphalt at 20-40 lbs/square Ply One or more Fl I ntglas P ly 4; Fl I ntg1as Premium Ply 6 BP-AA2 (Base, Spot-Asphalk-Applied) Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP.AA3 (Base, Spot -Asphalt -Applied) Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 (Ba, She Asphalt Applied) Base Yosemite Venting Base Hot asphalt in 9-Inch wide ribbons spaced as noted herein. BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square BP-CA3 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. SB5-AA (SOS, Asphalt Applied) Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 lbs/square Ply One or more Flintlastic Base 20; Flintlastic Poly SMS Base; FlIntlastic Ultra Poly SMS Base Cap Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar; Flinflastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar, Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar NEMO ETC, ULC Certificate of Authorization 932455 Prepared by: Robert Nienninen, PE-59166 So" EDITION (2017) FBC NON-HVHZ EVALUATION CertalnTeed Flintlastic- Modified Bitumen Roof Systems; (6101 651-SB47 Evaluation Report 3520.03.04-R24 for F1.2533-1123 Revision 24: 06/20/2019 Appendix 1, Page 3 of 67 NNEMOjetc. CERTAINTEEo FLINTLASTIC' MODIFIED BITUMEN COMPONENTS &APPLICATION MaHODS (CONTINUED) .. ... .. ... REFERENCE LAYER MATERIAL APPLICATION Base Flintlastic Base 20; Plintlastic Poly SIAS Base; Flintlastic Ultra PolySMS Base Note: Base plycures overnight priorto application ofthe ply orcap ply. FlintBond Brush or Karnak No. 81 Cold SBS­CA1 Ply Flintlastic Base 20; Flintlastic Poly SIMS Base; Flintlastic Ultra PoIySMS Base Process Modified Bitumen Adhesive Brush Cap Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FIR Dual Cap; Flinflastic FR-P; Flintlastic FR-P PSS, Cold -Applied) Grade at I gal/square CoolStar; Flinflastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flinflastic GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA2 Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Henry #903 Adhesive at 1.5 gal/square. Cap Flintlostic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P (SBS, Cold -Applied) CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar Base Flinflastic Base 20; Flinflastic Poly SMS Base; Flintlastic Ultra Poly SIAS Base SBS-CA3 Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Millennium Hurricane Force Membrane (SBS, Coki-Applied) Adhesive, beads spaced 6-inch D.C. Cap Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flinflastic FR-P CODIStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; FlIntlastic GMS CoolStar Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T SBS-TA (SBS, Torch -Applied) Torch -Applied Ply One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T Cap Flintlastic PR Cap 30 T, Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS-FR; Flintlastic GTS-FR CoolStar Base One or more Flintlastic APP Base T, Flintlastic STA; Flintlastic STA Plus APP-TA (APP, T.,ch-A,pMd) Torch -Applied Cap Flinflastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR CoolStar SBS-SA-H (SES, Self-Adherng, HJ,,W S,,Wro�) Base/Ply Black Diamond Base Sheet, Flintlastic Ultra Glass SA Self -Adhering (gas7 (PR 'nt la"st7SAP I 'vB a se. �FILT ead'17qSA =1dP1 rih CO. (�,Rntfqlc SA Ca Ill i ntlastic SA Cap PR CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FIR Cool Star 16, Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following MDP I imitations. The lesser of the MDP listings below vs. those in Table 3Aap plies: VAPOR BARRIER OPTIONS; SrRUCTURALCONCRETE DECK; ADHERED INSULATION PER TABLE 3A� (The lesser of the MDP listings below vs� those 'in Table 3A a p plies) OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH VB-1. FlintPrime Flintlastic SA PlyBase Self -adhering OB500,12-inch D.C. -82.5 VB-2. FlintPrime Flintlastic GTA Torch -applied M-OSFA or M-PG1, 12-inch D.C. -420.0 VB-3. FlintPrime Flintlastic Base 20 T, FlintlasticFRCap30TorFlintlasticGTS Torch -applied M-OSFA or M-PG1, 12-inch D.C. -495.0 17. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. NEMO ETC, LUC Evaluation Report 3520.03.04-R24 for FL2S33-1123 Certificate ofAuthorization 932455 V"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/20/2019 Prepared by: Robert Niammen, PE-S9166 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 4 of 67 ONEMOjetc. TABLE IF-2: WOOD DECKS — NEW CONSTRUCTION, REACCIF (TEAR -off) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BON DIED ROOF COVER System Deck Base Sheet Root Cover (Note 15) MDP No. (Note 1) Base Fasteners Attach Ply Cap (Psf) Glasbase; Flexiglas; Flintlastic Flintfast 3 in. Insulation Plates with (Optional) BP- Min. 15/32-inch plywood Base 20; Poly SMS Base; Ultra FlintFast P12 or 914; Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c. in three AA, SBS-AA, SBS-AA, SBS- W-95 at max 24-inch spans Poly SMS Base; Yosemite Venting Insulation Plates with DP or HD; OMG 3 (3), equally spaced, staggered center rows SBS-TA or TA or APP-TA -97.5 Base in. Round Metal Plates with OMG 414 HD APP-TA Min. 15/32-inch plywood OMG 3 in. Round Metal Plates with ONIG 6-inch o.c. at 4-inch lap and 6-inch o.c. in three W-96 at max 24-inch spans Flintlastic APP Base T M14 HD (3), equally spaced, staggered center rows. APP-TA APP-TA -97.5 Glasbase; Flexiglas; Flintlastic Flintfast 3 In, Insulation Plates with (Optional) Bp- Min. 15/32-inch plywood Base 20; All Weather/ Empire 8-inch o.c. at4-inch lap and 8-inch o.c. at three SBS-AA or W-97 at max 24-inch spans Base; Poly SMS Base; Ultra Poly FlintFast#14; Trufast3" Metal Insulation (3) equally spaced, staggered center rows AA, SBS-AA or SBS-TA -97.5 Plates with Trufast HID SBS-TA SMS Base; Yosemite Venting Base Glasbase; Flexiglas; Flinflastic BP -AA, SBS- Min. 19/32-inch plywood Base 20; Poly SMS Base; Ultra 7-inch o.c. at 3-inch lap and 7-inch o.c. in three SBS-AA, SBS- W-98 at max 24-inch spans Poly SMS Base; Yosemite Venting Note 2 (3), equally spaced, staggered center rows AA, SBS-TA or TA or APP-TA -105.0 Base APP-TA Min. 19/32-inch plywood OMG 3 in. Round Metal Plates with OMG 7-inch a. c. at 3-inch lap and 7-inch o.c. in three W-99 at max 24-inch spans Flintlastic APP Base T #14 HD or Dekfast Hex Plate with Dekfast (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 414 Glasbase; Flexiglas; Flintlastic Flintfast 3 in. Insulation Plates with (Optional) BP- Min. 15/32-Inch plywood Base 20; Poly SMS Base; Ultra FlintFast #12 or#14;Trufast3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c. in four AA, 5BS-AA, SBS-AA, SBS- W-100 at max 24-inch spans Poly SMS Base; Yosemite Venting Insulation Plates with DIP or HID; OMG 3 (4), equally spaced, staggered center rows SBS-TA or TA or APP-TA -127.5 Base in. Round Metal Plates with OMG 414 HD APP-TA Mm 1�12'41 - �' 0 G 3 in. Round Metal Plates with OMG 6 nch h lap and 6-Inch o.c. in four -; W_1O1 at a _n cc�hP,.1:o.c1 s Flintlastic APP Base T If IM4 H D 4 e =nd taggered center rows. ( , q , s APP-TA APP-TA -127.5 Ooui-Appum Sysnms; Glasbase; Fleidglas Base; Min. 15/32-inch plywood Flintlastic Base 20; All Weather Flintfast 3 in. Insulation Plates with 8-inch a.c. at 4-inch lap and 8-inch o.c. in three (Optional) W-102 at max 24-inch spans Empire Base; Yosemite Venting FlintFast 912 or 914; Trufast 3" Metal (3), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -52.5 Base; Flintlastic Poly SMS Base; Insulation Plates with DP or HD Flintlastic Ultra Poly SMS Base NEMO ETC, U.0 Evaluation Report 3520.03.04-R24 for FL2533-R23 Certificate of Authorization H32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/20/2019 Prepared by: Robert Niemmen, PE-59166 CertainTeed Flintlastic- Modified Bitumen Roof Systems; (610) 651-5847 Appendix 1, Page 19 of 67