Loading...
HomeMy WebLinkAboutKSM - INSPECTION� Cto �� C) 504 '0 Head rters Mailing 11345 U.S. High a I I Aff ENGINEERING P.O. Box 78-1377 Sebastian, FL. 329 Sebastian, FL. 32978 Orlando, XV& AND TESTING Phone: 772-589-0712 723 Progress Wa C.A. # 5693 Sanford, FL. 32772 KSMengineering.net 11/2512019 The Storage Depot Center SCANNED 5801 S. US H-6-v I BY Fort Pierce, Florida St. Lucie County WIFF—Ei k3upjw! I KSM Project 9: 194.349-linsp Re: Structural Steel Inspection — Renovation To Whom It May Concern: Based upon a request from Matt Toeniskoetter with The Storage Depot Center on 11/2112019, we have been asked to conduct a visual site inspection to review the structural steel, as well as the, bolted and welded connections for the renovation of The Storage Depot Center. Representatives from KSM Engineering and Testing (KSM hereinafter) conducted a visual non-destructive site inspection on 11/25/2019 to review the structural steel and the bolted and welded connections for the renovation. Scope qf Inspection: To review and visually inspect the columns, beam reinforcements, added joistsfbridging, gusset plates/plate stiffeners, the bolted and welded connections for the renovation and along "vith verifying that they were installed in accordance to the signed/sealed construction draArings. 'I'lle visual non -de M-ctive observations of KSM serve to document or evaluate the condition of the structure. or assemblies at the time of the inspection within a reasonable professional engineering probability and certainly. All conclusions or.recommendations are based upon testing, observations, or information gathered on -site prior to completion of this document. If field conditions change or differ than as stated in this document, it is the responsibility of all parties to contact KSM -for additional review. General Proper�y Inforruation: Interior renovation to existing two-story CMU block construction indoor storage facility. The renovation consisted of reinforcing the flist-floor ceiling with added structural joists, beam reinforcement and upgraded column footings. Proudly Serving Florida since 1990 Page I of 4 .N. Conclusions and Recommendations: Based upon our observations, within a reasonable professional engineering certainly, the added structural reinforcement, new welded connections, new bolted connections and anchor bolts were properly installed and perf6nred according to the signed/sealed construction drawings. If you have any questions about this letter, please contact my office. Regards. Christopher S. Larun, E.I. Geotechnical Engineer Florida Lie. No. If 000.12858 11/27/2019 Proudly Serving Florida since 1990 Poge 4 of 4 UU S E OF 11/27/2.019 by,