HomeMy WebLinkAboutNOASCANNED
BY
DADE St. Lucie County 10 xe4 %0
MIAWDADE Lpa --'a, MIAMI-DADE COUNTY
le"! 00 67 PRODUCT CONTROL SECTION
1616r,5�-e,
oel, 11�, 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOUR(% *R) Miarai, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miantidade.gov/economy
Johns Manville Corporation
717 17th Street
Denver, CO 80202
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami -Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner, the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: JM TPO Single Ply Roof Systems over Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
Tj-0A. Failure to comply with any section of this NOA shall be cause for termination and removal of.
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, FI orida,' and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 14-0627.07 and consists of pages I through 4 1.
The submitted documentation was reviewed by Jorge L. Acebo.
, �J
FILE COPY
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval.Date: 12113/18
Page I of 41
ROOFING SYSTEm APPROVAL
Category:
Roofing
Sub -Category:
Single Ply
Materials:
TPO
Deck Type:
Concrete
Maximum Design Pressure:
-465 psf.
TRADE NAmEs OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
TABLE 1
Product
JM TPO 45
JM TPO 60
Test
Dimensions SPecifleation
45 mils thick
60 mils thick
� �JMTPO �80� �80mils �thick
JM TPO F13 115
JM TPO FB 135
JM TPO FB 150
JM TPO FB 175
DynaBase
JM Urethane Insulation
Adhesive
JM One Step Foamable
Adhesive
JM Two Part Urethane
Insulation Adhesive
JM Two Part Urethane
Insulation Adhesive
Canister
JM Roofing System
Urethane Adhesive
60 mils thick
Product
Description
ASTM D6878
Polyester reinforced Thermoplastic
TAS 131
Olefin single ply membrane.
ASTM D6878
Polyester reinforced Thermoplastic
TAS 131
Olefin single ply membrane.
ASTM D6878
Polyester reinforced Thermoplastic
TAS 131
Olefin single ply membrane.
ASTM D6878
Polyester reinforced, fleece backed,
TAS 131
Thermoplastic. Olefin single ply
membrane.
80 mils thick
ASTM D6878
Polyester reinforced, fleece backed,
TAS 131
Thermoplastic Olefin single ply
membrane.
60 mils thick
ASTM D6878
Polyester reinforced, heavy -fleece
TAS 131
backed, Thermoplastic Olefin single ply
membrane.
80 mils thick
ASTM D6878
Polyester reinforced, heavy -fleece
TAS 131
backed, Thermoplastic Olefin single ply
membrane.
39-3/8" x 49'211
ASTM D61631
An SBS modified bitumen coated,
Type I Grade S
fiberglass reinforced base sheet.
1 gal.
Proprietary
A one part, cold -applied adhesive.
N/A Proprietary Two part urethane low rise foam
insulation
Various Proprietary A two -component, cold -applied
adhesive.
N/A Proprietary Self-contained two-part, low-rise foam
adhesive
Various Proprietary A two-componefit, cold -applied
adhesive.
NOA No.: 18-0501.02
MAMMADE COUNW
M. - 1=1 Expiration Date: 12124/23
Approval Date: 12/13/18
Page 2 of 41
TRADE NAmEs OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
TABLE 1
Test
Product
Product,
Dimensions
SRecification
Description
T
FdhepM TPO Membrane
5 gal.
Proprietary
A synthetic rubber -based adhesive used
siovie (Solvent -Based)
'So'v t- s'
on single ply roofing membranes.
embramne
n o i
m 11
5 gal.
Proprietary
One -part, synthetic polymer -based
=Bondping
.
sl (TPO a
Adhesive (TPO & EPDM)
membrane adhesive
JM TPO Membrane
5 gal.
Proprietary
A synthetic rubber -based adhesive used
Adhesive (Low VOC)
with fully or partially adhered TPO
roofing membrane systems.
JM TPO Low VOC
5 gal.
Proprietary
A synthetic rubber -based a dhesive used
Membrane Adhesive
to adhere TPO roofing membrane
systems.
JM TPO LVOC Membrane
5 gal.
Proprietary
A synthetic rubber -based adhesive used
Adhesive
to adhere TPO roofing membrane
systems.
JM LVOC Membrane
5 gal.
Proprietary
'A synthetic rubber -based adhesive used
Adhesive (TPO & EPDM)
to adhere TPO roofing membrane
systems.
JM TPO Membrane
5 gal.
Proprietary
A polymeric, wet laying (single side
Adhesive (Water -Based)
application), low-VOC adhesive.
JM TPO Water Based
5 gal.
Proprietary
One part, water based adhesive used to
Membrane Adhesive
adhered TPO roofing membrane systems
ICP Adhesives CR-20
Various
Proprietary
Spray applied, two-part reactive
urethane foam adhesive
JM TPO Membrane Primer
3 gal.
Proprietary
A synthetic polymer -based primer.
JM Single Ply Membrane
3 gal.
Proprietary
A low VOC, synthetic polymer -based
Primer (Low VOC)
primer.
JM Green Two Part
5 gal.
Proprietary
A two -component, plant based, low
Urethane Insulation
VOC adhesive.
Adhesive
562" x 30" x 50'
Proprietary
Textured walkway protection
membrane.
JM TPO Detail Membrane
24" x 50'
TAS 131
Non -reinforced membrane for wrapping
pipe flashings and vertical stacks and for
waterproofing joints of JM TPO Coated
Metal.
JM TPO Universal Comers
Various
TAS 131
Pre -molded for easy installation of curb
flashings or comer flashings on JM
TPO-Coated Metal or JM TPO
Membrane.
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval Date: 12113/18
Page 3 of 41
TRADE NAmEs OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
TABLE 1
Test
Product
Dimensions
Specification
Description
�JMTPO T-Joint Patch
4"
TAS 131
Non -reinforced membrane patch for
covering t-joints and/or discs and
fasteners.
JM TPO =Pipe Boots
ill x 61'
TAS 131
Cone -shaped stepping boots designed
for flashing pipe penetrations.
JM TPO Peel & Stick Pipe
it, x 61'
TAS 131
Cone -shaped stepping boots designed
Boo
for flashing pipe penetrations.
QM TPO =Split Pipe Boot
Vario us
TAS 131
Cone shaped stepping boots designed
.
for flashing pipe penetrations.
JM Square Pipe Boots
211 X 8" & 411 X 8"
TAS 131
Square shaped stepping boots designed
for fla�hing pipe penetrations.
JM TPO Cover Tape
6" x 100'
TAS 131
30 mil membrane with a factory -applied
peel and stick adhesive tape used to strip
in metal flanges.
JM TPO 10" Cover Tape
10" x 100'
TAS 131
.30 mil membrane with a factory -applied
peel and stick adhesive tape used to strip
in metal flanges.
EJM T7:P0::Penctration 7Pocl et
7.51' X 61'
TAS 131
Two-piece molded pocket with a rigid
vertical wall and preformed flanges.
(ETPO CoatedMetal
4'x 10'
Proprietary
JM TPO Membrane laminated onto
galvanized steel.
JM TPO Peel & Stick 6"
6" x 100'
TAS 131
45 mil TPO membrane strip with a 3"
RTS
tape factory laminated along one edge.
JM TPO Peel & Stick 10"
10" x 100'
TAS 131
45 mil TPO membrane strip with a 3"
RPS
tape factory laminated along one edge.
18" x 50'
TAS 131
60 mil TPO membrane for flashing
curbs and parapet walls.
JM TPO Reinforced Cover
8" X 50'
TAS 131
60 mil TPO membrane strip use as a
Strip
heat -weldable strip in mechanically
fastened systems.
JM Vapor Barrier SA
45" x 134'
Proprietary
Polyethylene -Reinforced, Self -Adhering
SBS Vapor Barrier
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval Date: 12/13/18
Page 4 of 41
APPROVED INSULATIONS:
P����
GY 3, ZGY 3 25 PSI,
ValuTherm, ValuTherin 25 PSI,
R-Pancl, R-Pauel 25 PSI
ENRGY 3 AGF,
ENRGY 3 AGF 25 PSI,
ENRGY 3 CGF,
ENRGY 3 CGF 25 PSI,
ValuTherm AGF,
ValuTherm AGF 25 PSI,
ValuTherm CGF,
ValuTherm CGF 25 PSI
ENRGY 3 FR,
ENRGY 3 FR 25 PSI
Invinsa Roof Board
Invinsa FR Roof Board
RetroPlus Roof Board
JM SECUROCK Gypsum -Fiber
Roof Board
DensDeck
DEXCcll FA Glass Mat Roof Board
DEXCell Cement Roof Board
MIAMMADE COUNTY
�Kwlllrd=
TABLE2
Product Description
Polyisocyanurate insulation
Isocyanurate Insulation with glass
reinforced facers
Isocyanurate Insulation with inorganic
coated glass reinforced facers; bottom
face is premium coated for
combustible decks.
High density polyisocyanurate board
with fiber glass reinforced facers
High density polyisocyanurate board
with fiber glass reinforced facers
High density, perlite base cover board
Fiber reinforced coverboard
Silicone treated gypsum
Coated glass mat faced gypsum cover
board
Cement and glass mesh cover board
Manufacturer
(With Current NOA)
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Georgia Pacific Gypsum, LLC
National Gypsum Company
National Gypsum Company
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval Date: 12/13/18
Page 5 of 41
APPROVED FASTENERS:
TABLE3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1
UltraFast 3" Round
Galvalume AZ55 steel
3" diameter
Johns Manville
Metal Plates
Insulation Plate
2.
UltraFast Square Metal
Galvalume AZ55 steel
3" square
Johns Manville
Plate
Insulation Plate
3.
All Purpose Fasteners
Insulation and membrane
#14 x 16" max.
Johns Manville
fastener
length; #3 Phillips
head
4.
High Load Plates
Seam plate with
2-3/8" round steel
Johns Manville
reinforcing ribs and
plate
eyehooks
5.
JM TPO RhinoPlate
Insulation Plates
3.15" diameter,
Johns Manville
6.
High Load Plus Plate
Seam plate with
2-3/4" round steel
Johns Manville
reinforcing ribs and
plates
eychooks
I
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval Date: 12/13/18
Page 6 of 41
EVIDENCE SUBMITTED:
Test AgencV
Test Identifier
Description
Date
FM Approvals
3032235
FM 4470
06/27/08
3030383
FM 4470
05/13/08
3023458
FM 4450
07/18/06
3036942
FM 4470
10/02/09
3036559
FM 4470
10/02/09
3035538
FM 4470
10/02/09
3044716
FM 4470
10/29/12
3046174
FM 4470
04/03/13
3051609
FM 4470
08/24/14
3053026
FM 4470
01/20/15
3056677
FM 4470
02/22/16
3060614
FM 4470
04/14/17
3058326
FM 4470
09/30/16
3063554
FM 4470
02/15/1'8
3055845
FM 4470
05/25/16
3056049
FM 4470
01/13/16
3033308
FM 4470
09/03/08
Momentum Technologies
RXlOA8A
TAS 131
03/29/10
RX14C8A
TAS 131
03/29/10
RX10A813
TAS 131
03/29/10
PRI Construction Materials
JMC-088-02-01.5
ASTMD1876/TAS 117(13)
02/22/18
Technologies LLC
TAS 117(A)/TAS 114(C)
JMC-132-02-02
TAS 114(D)
07101/13
JMC-143-02-01
TAS 114(D)
07/01/13
JMC-180-02-01
Physical Properties
11/11/13
JMC-183-02-01.1
Physical Properties
12/18/13
JMC-186-02-01.1
TAS 131
09/19/14
JMC-186-02-02.1
TAS 131
10/10/14
JMC-193-02-01
TAS 114 J
04/01/14
JMC-193-02-01A.1
TAS 114 J
04/2/14
JMC-209-02-01
TAS 114 J
10/15/14
JMC-214-02-01
Physical Properties
11/03/14
JMC-221-02-01
Physical Properties
11/19/14
JMC-277-02-01
TAS 114 D
05/04/17
JMC-303-02-01
TAS 114 J
05/25/17
JMC-311-02-01
TAS 114 D
06/26/17
ADCO-001-02-01
Physical Properties
06/16/13
UL LLC
R10167
UL 790
11/20/13
Trinity I ERD
J33600.08.13
TAS 131
08/09/13
SC4910.02.14
TAS 114J
02/10/14
NOA No.: 18-0501.02
MIAMI-DADE COUNTY
r —W 0=1 Expiration Date: 12/24/23
Approval Date: 12113/18
Page 7 of 41
Membrane Type: TPO
Deck Type 31: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(6): One or more layers of insulation adhered with approved adhesive; membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more,layers of any of the following insulations.
!R&Watiup I�ayer Insulation Fasteners Fastener
Q
(Table 3) Density/ft'
Invinsa Roof Board, JM SECUROCK Gypsum -Fiber Roof Board
Minimum 1/41' thick N/A N/A
Ea1RGX-3,E.NRGY3 25 PSI, ValuTherm, ValuTherm �5 PSI, R-PaneI, R-Panel 25 PSI,
ENRGY 3 AGF, ENRGY--T-A-GF 25 PSI, ValuTherna AGIF, ValuTherm AGF 25 PSI,
ENRGY 3 CGF, ENRGY 3 CGF �5 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI,
ENRGY 3 FR, ENRGY 3 FR 25 PSI
Minimum 1.511 thick NIA N/A
Note: All Insulation layers shall be adhered JM.Roofing System Urethane Adhesive JM Two -Part
Urethane Insulation Adhesl�e, or JM Two Part Urethane Insulation Adhesive Canister applied in
%11 to %" ribbons spaced 12", o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment;
Membrane: JM TPO fully adhered to insulation using JM TPO Water Based Membrane
Adhesive applied at the rates listed below. Side laps will be a minimum 2.5" wide
and shall be sealed with a minimum 1.5" wide heat weld.
0.63-0.83 gal./sq. when applied over ENRGY 3, ValuTherm, or R-Panel Insulation
Boards.
0.56-0.71 gal./sq. when applied over Inivinsa Roof Board.
0.59-0.77 gal./sq. when applied over JM SECUROCK GypsummFiber Roof Board.
Or
(to ENRGY 3 only) JM TPO fully adhered to insultion using JM Membrane
Bonding Adhesive (TPO & EPDM) applied at a combined rate of 1. 10 gal./sq. to
both the membrane and the substrate. Side laps will be a minimum 2.5" wide and
shall be sealed with a minimum 1.5" wide heat weld.
Or
(to E14RGY 3 or SECUROCK only) JM TPO FB 115 or 135 fully adhered to
insulation using JM Two Part,Urethane Insulation Adhesive Canister applied in
splatter pattern at 0.318 gal./sq. Side laps will be a minimum 2.5" wide and shall
be sealed with a minimum 1.5" wide heat weld.
Maximum Pesign -195 psf. with ENRGY 3, ValuTherm, or R-Panel (See General Limitation #9)
Pressures: -255 psf with Invinsa Roof Board (See General Limitation #9)
465 psf with SECUROCK (See General Limitation #9)
NOA No.: 18-0501.02
MIAMDADE COUNTY
BE 0=1 Expiration Date: 12/24/23
Approval Date: 12/13/18
Page 14 of 41
CONCRETE DECK SYSTEM LIMITATIONS:
1 If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a
field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns
and density. All testing and fastening design shall be in compliance with Testing Application Standard
TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137, calculations shall be signed and
seated by a Florida Registered Engineer, Architect, or Registered Roof Consultant.
GENERAL LIMITATIONS:
I Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the
fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations-�when the base sheet is fully mopped. If no recovery board is used the base sheet shall be
applie&using spotpopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8"
ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous
area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each
ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12
lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275
lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-
tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official,
a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a
Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When
this limitation is specifically referred within this NOA, General Limitation #9 win not -be
applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
conform with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and comers). Neither rational analysis, nor extrapolation shall be pernritted for enhanced
fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this
limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 6 1 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-0501.02
Expiration Date: 12/24/23
Approval Date: 12/13/18
Page 4i of 41