HomeMy WebLinkAboutWINDOW & SLIDING DOOR REPLACMENT PLAN�I ? C WINDOW & SLIDING GLASS DOOR REPLACEMENT PLAN NTS GENERAL STRUCTURAL NOTES: GENERAL: ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE 2017 FLORIDA BUILDING CODE. ALL WINDOWS TO BE INSTALLED PER NOA AND THE MANUFACTURER'S RECOMMENDATIONS/SPECIFICATIONS. LOADINGS: WIND LOADS: ULTIMATE WIND SPEED, 3 SECOND GUST: 165 MPH BUILDING CATEGORY: II EXPOSURE CATEGORY: D INTERNAL PRESSURE COEFFICIENT. +/-0.18 SECOND FLOOR OF BUILDING N\l \` Ni SCNNED =_ St. Lucie % Count, ;O� WINDOW/SLIDING GLASS DOOR SCHEDULE OPN'G PRODUCT SIZE GLASS PRODUCT WIND ACTUAL WIND I.D. (WXH) DESCRIPTION PRESSURE (ASD) PRESSURE (ASD) OS SLIDING GLASS DOOR 141.5"x95" NON -IMPACT +60.0 -98.5 +43.6 -56 O2 SLIDING GLASS DOOR 69.5"x95" NON -IMPACT +60,.0 98 5 +43.6 -56 O SINGLE HUNG WINDOW 51.75"x62" NON -IMPACT +50 -56.3 +43.6 -56 0 SINGLE HUNG WINDOW 35.375'x62" NON -IMPACT +50 -96.7. +43.6 -56 OINDICATES WINDOW OR SLIDER TO BE REPLACED IN EXISTING OPENING -SEE SCHEDULE .kSUMMII DESIGN & FORENSICS, INC. nsv Us WwaE aw., sum fw m3 kk(TltUlviWm S/0NAL011111110 OLn 0w zo �z C6 06 og Oa OF Tn Z g w E Ur w U c� g za H w Ul J D. oes,rnrn aeno-33 aM o"nwx asao-is tim cnec"Eo OB NO. 2019-146 S-1