HomeMy WebLinkAboutENGINEERINGa .. sneering . sting, Inc. Dated: September 18, 2019 t�ol.ol,�a ARK Home Remodeling, Inc. 8206 Santa Clara Blvd. Ft. Pierce, FL 34951 Attn: Tony Profeta RE: Field Withdrawal Resistance Test Crematorium 8549 US Highway 1 Port St. Lucie, FL 34982 Dear: Sirs: SCANNED BY Phone' 954-784-2941 . C+ I E-Fax: 9547784-7875 SEP 19 M9 ST. Lucie County, Job Order# 19R633 Pursuant to your request, Federal Engineering & Testing, Inc. (FE&T) has performed a field withdrawal resistance test in compliance with Testing Application Standard TAS-105 and the Florida Building Code High Velocity Hurricane Zone at the above referenced site. The purpose of our test,was to determine the uplift capacity of the mechanical fasteners at the above referenced project. FE&T. is a Miami Dade. Certified Testing .Laboratory. (Certification #18-1105.02). On 09/17/2019 our field representative visited the referenced site and conducted ten (10) field withdrawal resistance tests on the Dekfast #12 fasteners into the metal roof deck. All tests were found in compliance with the Florida Building Code and TAS-105. See attached copies of TAS-105 forms with test results. The test results presented reflect the condition of the roof system at the time of the test. These results are time and, sample dependent since roof conditions are continuously changing due to exposure to the elements. All tests were conducted according to the Florida Building Code Test Protocol TAS-105'using a calibrated Comten Industries Fastener Tester Model, No.DFG 2W2000 (see attached calibration). FE&T is an independent third party providing un-biased testing inforniation and results; FE&T is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. Federal Engineering & Testing, Inc., appreciates the opportunity to be of service to you at this phase of your project. If you have 'any`questions or comments, please give us a call. It has been a pleasure working with you and look forward to doing s'c It the near future. 1 `tai -e)l 62 REVIEWED FOR �ino,'ielg. 'FILE Keith kBlane,PIE:• Federal Engineering and Testing Inc. Florida Reg. Number 59394 Certificate of Authorization # 5471 Miami -Dade County Certification # 18-1105.02 CODE COMPLIANCE ST. LUCIE COUNTY BOCC Attachments include the following: Field Withdrawal Resistance Test Results Field Sketch Comten Calibration Florida Building Code Test Protocol TAS-105 Building Code Compliance Office Testing Application Standard TAS 105-11 Field Withdrawal Resistance Test Results General Information: Job Name: Crematorium Job Address: 8549 US Highway 1 _ Port St. Lucie, FL 34982 Contact Individual at jobsite (if any) Tony Profeta Testing Agency / Equipment Information: Q edel Q ngirane ring BQQesting, Inc. Note: The undersigned acknowledges that all testing has-been conducted and results have been reported in compliance with Florida Building Code Test Protocol TAS-105 Testing Agency Name: Federal Engineering & Testing Inc. . Company Address: 3370 NE.5th Avenue, Oakland Park, FL 33334 Company Telephone: (954) 784-2941 Company Fax:. (954) 784-7875 Representative Name: Mr. Keith LeBlanc P.E: . Representative Title: Professional En ' eer Signature: ,a Testing Apparatus:. Comten Industries, Fastener Tester Mode1,DFG2W2000 r, Building / Roof System Information: Building / Roof System Information: Building / Roof System Information: Area Number: 1 Roof Area Height .15 ft. Roof Area Length 140. - ft. Second Largest Dimension 35, ft. Total Roof Area . 5050 ft2 .51. sq. Perimeter Area . 1180 ft2 - (See RAS 117) - - Q ederal Q ngineering & QOesting, Inc. Area Number: . Roof Area Height ft. Roof Area Length ft. SecondLargest Dimension ft.' Total Roof Area ft2 sq. Perimeter Area ft? (See PAS 117) " Area Number: Roof Area Height ft. Roof Area Length ft. Second Largest Dimension ft. Total Roof Area ft2 s.q Perimeter Area ft2 (See RAS 117) Q ederal. Q ngineerng ®Q estin g r rawa esrs ance ecor mg eet Component to be secured: Area Number 1 ❑ Insulation (Refer to deck dimensions on Page No. 2) ❑ Membrane Fastener Type: #12 ❑ Anchor or Basesheet Fastener Manufacturer: Dekfast ❑ Woodblocking Predrilled: Yes ❑ No 0 ❑ Metal Profiles If Yes, Drill Bit Size:. N/A "diameter ID Resistance Verification Only Hole Depth; N/A See Section 8 to determine number of tests (If drill is Sample & Plan Identifier Initial Failure Load,(lbf) Roof Area 1 382' C' ' 2' 344 C 3.. 562 C. -' 4 313 P 5 . , 235 P 6. 255 P. 7: 261 F g..;..:: .34.7. : = F . 9 270 F 11: ' 12 13 14 15 " 16 17... 18. 19 20 21.- 22 23. 24 25. igh tolerance include range in 1/1000" tolerance) Sample,& Plan Initial Failure Roof Area Identifier Load (lbf) ' 26 - 27 . .28 29.. 30 31.. . 32 33 34 35. 36. 37 38 39.: 40 41 .42 43 44 '45 46 . :47 :48..• 49 50 Fastener Installation Information: Is the fastener a self driller? ❑ Yes 0'No If yes, list the type of tool used for fastener installation: N/A Speed of tool: N/A . rpm's Number of tests conducted: n= 10: * See section.8 of Test Protocol TAS 105 - - * Note the locations of all tests on "Building Infornation" Detail #l, attached) Mean Failure Load' Sample Standard Deviation Minimum Characteristic Resistance Force F= 320.80 lbf Sf= 98.74 If P= 298.34 lbf iederal ngineeringOesting,. Inc. Notes: 1) Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet. fastener spacing, as outlined in RAS 117, shall utilize the minimum characteristic resistance force (P), determined in compliance with Section 9 of TAS 105. No margin of safety shall be applied to field withdrawalresistance test results determined incompliance with TAS 105. - - 2) A safety factor of 2 to I shall be applied to all results of laboratory testing... 3) The following pagesshall be completed for each roof area'and included with all Field Withdrawal Resistance Test Recording Sheets. if it T6 11 1 :3s, 41 L, 14-4 j I 4p --1 I 1 1% v t NTS -Job Address - City, State