HomeMy WebLinkAboutHVAC LOAD CALCULATIONSSFP 2 4 M9 ST, Wde Harbour Ridge REM-ENCL f HVAC Load Calculations for Harbour Ridge POA 13404 HARBOUR RIDGE BLVD 2A PALM CITY. FLORIDA 34990 SC'gAt . . St 4gy �u "Cie nr`nfY SHGC WARNING: The window performance values consist of the u-factor for the frame, and Solar Heat Gain Coefficient (SHGC) for the glass. These values have a huge Impact on the building thermal envelop and may have a significant Impact on the following: • the size of the HVAC system(a), $$$ • the duct work layout and design, $$ • delays with permitting, $$$$ • Inspector comments or failed Inspections $$ It Is Important to us that your project stay on schedule and if there are any changes to the design base It may impact any of the bullet points above. KO Enemy Design must be contacted immediately at info enkoenemydesion.com or (561) 327-7272 to help support any changes to your project Information. Prepared By: Karen KO Ener( 1470 N Conglq West Palm Wednesday, Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. �® �G e d® &er4, 2019 ®�klGJOB ,Rhvac -Residential &tight Commercial HVAC.Loads -Elite Software Development, Inc. KO Enerav Design LLC �;. �11 • Harbour Ridqe REM-ENCL 13404. 1 Pro'ed Report Ll G6neraIiPro'ect'Informati6nse '1ZZK'` :ice ME3 '•'` Project Title: Harbour Ridge REM-ENCL 13404 Designed By: Karen Oliver Project Date: Wednesday, July 3, 2019 Client Name: Harbour Ridge POA Client Address: 13404 HARBOUR RIDGE BLVD 2A Client City: PALM CITY, FLORIDA 34990 Company Name: KO Energy Design Company Representative: Karen Oliver Company Address: 1470 N Congress Ave, Ste 106A Company City: West Palm Beach, FL Company Phone: 561-327-7272 Company E-Mail Address: info@koenergydesign.com Company Website: www.koenergydesign.com Permit Number(s): Jurisdiction: 661000 Desi nData Reference City: Fort Pierce, Florida Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Bulb Grains Difference Deb Wat Bulb RAIHijm BeLHum Dry Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 s• rChec Ei` fires '��;:'.P Total Building Supply CFM: 1,293 CFM Per Square ft.: 0.739 Square ft. of Room Area: 1,749 Square ft. Per Ton: 624 Volume (ft3): 14,551 Buildin 'Loads a ;?' �w n i :.: r ` ':E* "1, r"tom "" fiif Total Heating Required Including Ventilation Air: 26,155 Btuh 26.155 MBH Total Sensible Gain: 28,429 Btuh 85 % Total Latent Gain: 5,205 Btuh 15 % Total Cooling Required Including Ventilation Air: 33,634 Btuh 2.80 Tons (Based On Sensible + Latent) `Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J Bth Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ... \13404 Harbour Ridge Blvd-MJ.rh9 Wednesday, September 4, 2019, 2:32 PM RfivaomResidential 8 Light Commercial HVAC MOMM `,_O7EnerpV�De�sign LLG Elite Software Development, Inc. Harbour Ridga REM-ENCL 13404 e'i ` m. Load Preview Report Ne ft. Sa La Ne Se Htg Cg Al,Duct Scope To /ro Are (Se Gai Gal Loss CFM CFM CFM SiZ Buildino 2.80 624 1,749 28,429 5.205 93,634 26.155 340. 1,293 1,293 System 1 2.80 6241,749 28,429 5,205 33,634 26,155 3401M 1,293 0' SuoDly Duct Latent 1,284 1,284 _ Zone 1 1.749 28,429 3,921 32,350 26,155 340 1,293 1-Existing 1,559 17,316 2,944 20.260 14,763 192 788 4-0 2-Back Enclosure 122 7,643 505 8,148 6,448 84.348 2-0 3-Fmnt Enclosure 68 3.470 472. 3,942 4,943 64® 158 1-0 CA ...M404 Harbour Ridge Blvd-MJ.rh9 Wednesday, September 4, 2019, 2:32 PM Rhvac -Re idential & Light Commercial HVAC Loads Elite 5oftwareMevelopment, Inc. KO Energv Design LLC Harbour Ridge:REM-ENCL 13404: 'West Palm DeaOFL,: ..... P Total Building Summaty Loads Component An°�. Lt, en�, �Tdtalr y `d3" Descri t'on a. s :r, Gam, . Gai�fi 1A-hw-o: Glazing -Single pane, operable window, heat- 133.2 3,358 0 5,415 5,415 absorbing, wood frame, U-value 0.9, SHGC 0.48 NSISGD770: Glazing-NSI Windows & Doors SDG770 190.8 5,932 0 7,853 7,853 Gray Tint, U-value 1.11, SHGC 0.43 11 D: Door -Wood - Solid Core, U-value 0.39 20 219 0 203 203 13A-5ocs: Wall -Block, board insulation only, R-5 board 927.1 3,246 0 1,773 1,773 insulation, open core, siding finish, U-value 0.125 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud 30.7 58 0 36 36 cavity, no board insulation, siding finish, wood studs, U-value 0.068 16E-30:Roof/Ceiling-Under Attic with Insulation on Attic 1582.6 1,418 0 1,266 1,266 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Light Tile, Slate or Concrete, R-30 insulation, U-value 0.032 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 190 170 0 304 304 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane R-30 insulation U-value 0.032 Subtotals for structure: 14,401 0 16,850 16,850 People: 4 800 920 1,720 Equipment: 0 4,873 4,873 Lighting: 0 0 0 Ductwork: 7,351 1,284 4,548 5,832 Infiltration: Winter CFM: 143, Summer CFM: 75 4,403 3,121 1,238 4,359 Ventilation: Winter CFM: 0 Summer CFM: 0 0 0 0 0 Total Building Load Totals: 26,155 5,205 28,429 33,634 s " CheckFi re' Total Building Supply CFM: 1,293 CFM Per Square ft.: 0.739 Square ft. of Room Area: 1,749 Square ft. Per Ton: 624 Volume (ft'): 14,551 i a xMn , , .Bu'I 'n' '•Loads ;hP .'Sa",H'S.r R"-.'�'*�.Q+ �.! =' '�';7_..„" . a�;,. s: ,. n, OF 3 Total Heating Required Including Ventilation Air: 26,155 Btuh 26.155 MBH Total Sensible Gain: 28,429 Btuh 85 % Total Latent Gain: 5,205 Btuh 15 % Total Cooling Required Including Ventilation Air: 33,634 Btuh 2.80 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance data at your design conditions. C:\ ... \13404 Harbour Ridge Blvd-MJ.rh9 Wednesday, September 4, 2019, 2:32 PM Wall 13% Glass 36% Glass 39% Roof 6% Roof 5% Wall 5% Infiltration 17% Ductwork 28% Door 1 % Infiltration 13% Door 1 % People 5% Ductwork 17% Equipment 14% CA ...M404 Harbour Ridge Blvd-MJ.rh9 Wednesday, September 4, 2019, 2:32 PM Rhvae - Residential &tight Commercial HVAC Loads ' Elite Software Development, Inc. KO Energy Design LLC . �.. � Harbour,Ridge REM ENCL 13404, W 411 4111! System 1 System #1 Summmy Loads Component' Area Sen r Son Totals =Des'' c }do uan Loss i Gain Gai"` 1A-hw-o: Glazing -Single pane, operable window, heat- 133.2 3,358 0 5,415 5,415 absorbing, wood frame, U-value 0.9, SHGC 0.48 NSISGD770: Glazing-NSI Windows & Doors SDG770 190.8 5,932 0 7,853 7,853 Gray Tint, U-value 1.11, SHGC 0.43 11 D: Door -Wood - Solid Core, U-value 0.39 20 219 0 203 203 13A-5ocs: Wall -Block, board insulation only, R-5 board 927.1 3,246 0 1,773 1,773 insulation, open core, siding finish, U-value 0.125 12E-Osw: Wall -Frame, R-19 insulation in 2 x 6 stud 30.7 58 0 36 36 cavity, no board insulation, siding finish, wood studs, U-value 0.068 16E-30: Roof/Ceiling-Under Attic with Insulation on Attic 1582.6 1,418 0 1,266 1,266 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Light Tile, Slate or Concrete, R-30 insulation, U-value 0.032 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 190 170 0 304 304 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane R-30 insulation U-value 0.032 Subtotals for structure: 14,401 0 16,850 16,850 People: 4 800 920 1,720 Equipment: 0 4,873 4,873 Lighting: 0 0 0 Ductwork: 7,351 1,284 4,548 5,832 Infiltration: Winter CFM: 143, Summer CFM: 75 4,403 3,121 1,238 4,359 Ventilation: Winter CFM: 0 Summer CFM: 0 0 0 0 0 System 1 System #1 Load Totals: 26,155 5,205 28,429 33,634 Check, Supply CFM: 1,293 CFM Per Square ft.: 0.739 Square ft. of Room Area: 1,749 Square ft. Per Ton: 624 Volume (ft3): 14,551 Total Heating Required Including Ventilation Air: 26,155 Btuh 26.155 MBH Total Sensible Gain: 28,429 Btuh 85 % Total Latent Gain: 5,205 Btuh 15 % Total Cooling Required Including Ventilation Air: 33,634 Btuh 2.80 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\13404 Harbour Ridge Blvd-MJ.rh9 Wednesday, September 4, 2019, 2:32 PM Rhvac - Residential & Light .Commercial 'HVAC Loads KO EnergPDesign LLC West Palm Beach FL -33411, Elite Software Development, Inc. Harbour Ridge REM-ENCL13404 _ 7 S stem 1 Room Load Summa Room No Name "`�'•'SF' Htg Min Area Senses ''Htg .Btuh"^'-GFM Run Run r 4,ItZg' Clg Min , Duch DuctSens Lat�t Cig a Size "tw-?�•Vel `Btuhtir•f•Btuh'# �.,CFMi:• Act Sys CFMi --Zone 1-- 1 Existing 1,559 14,763 192 4-0 0 17,316 2,944 788 788 2 Back Enclosure 122 6,448 84 2-0 0 7,643 505 348 348 3 Front Enclosure 68 4,943 64 1-0 0 3,470 472 158 158 Duct Latent 1.284 System 1 total 1,749 26,155 340 28,429 5,205 1,293 1,293 Cooling System Su ma <, *Cooking , ,Sensible/Latent'" 3 Tons S Id Semen ble ,r Latent Btuh "'Btuh r ^ Total` Btuh Net Required: 2.80 85% / 15% 28,429 5,205 33,634 CA ...\13404 Harbour Ridge Blvd-MJ.rh9 I Wednesday, September 4, 2019, 2:32 PM KO Energy Design 561 327-7272 Field Verification Requirement Project Information Designed by: Karen Oliver Project date: Wednesday, July 3, 2019 Client name: Harbour Ridge POA Client address: 13404 HARBOUR RIDGE BLVD 2A Client city: PALM CITY, FLORIDA 34990 Company name: KO Energy Design Company phone: 561-327-7272 Field Verification Requirement All inputs/defaults/building characteristics used for the ACCA Manual J Version 8 calculations must be verified by the Homeowner and/or must be verified by the builder/owner/contractor verifying that what is built is consistent with the builder's/owners project components used in this report. All data used for Manual J sizing report is based on RFI received via customer.. K.O. Energy Design must be notified in writing of any said changes to RFI. Equipment Selection Equipment selected below was carefully chosen to meet or exceed the FL Energy Efficiency Code. Alternate equivalent equipment selection shall also meet the attached Energy Code Requirements. Any change in SEER or size of equipment will require approval and plan revision. K.O. Energy Design must be notified in writing of any said changes. Manual D Duct Sizing Duct sizing has been carefully engineered at the stated s.p. Any deviance in duct sizing could impact the performance and efficiency of selected equipment. Any change or alteration in duct sizing will require approval and possible plan revision. K.O. Energy Design must be notified in writing of any said changes. Duct sealing Air Distribution System Test to be performed and made available for Rough Duct Inspection, if required.