HomeMy WebLinkAboutDESIGN CERTIFICATION FOR WIND LOAD COMPLIANCEr s St. Lucie County PUBLIC 'WORKS DEJ PARTM)ENT �°%o5t'2�t<` CODE COMPLIANCE DfVISION n � 2300 Virginia Avenue �G7 Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance This Certification must be completed by the project design architect or engineer. This Certification ntusl be subtilittod in duplicate with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any oouresidential structure. This Certification shall not apply to interior renovations (provided that no exterior Structural Willis, colunms or other components are being affected) and certain other minor building perulih. For further assistance, please contact the Building Inspection Office at (772)462-2172. Project Nallie l $ t Lo o _ SuLct Address O-Liss i.�Yid7:;' �"N 4M jthT1;'9'rtY�"y.,L!11�dGSVJ:4P {Q0�1 yY'�6i'^i��inr�� £Yt ';. �y '(Y_•,.. Permit Number F Occupancy T e .] t G fowl o- Construction T re Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designui to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St, Lucie County. 1 also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. I)eaiin Parameter and A,ssumutiou,,Ts;d• (Please check or complete the appropriate box.) 1 Florida Building Code 20 07 Edition with 20 09 Supplements and ASCE 7 4)5 2. Building Design is: Enclo t'�ed: PartiallY Enclosed: Open Building: r � 3, Menu Roof height: t Roof Pitch;. JJ ( Internal Pressure Coefficient: o. CO 4. Width of End Zone: 4 -� Wind Speed: (3 see. gust) S. Building Classification 'ruble 1-1, ASCE 7 -OS FBC Table 1604.5 .IL 6, Wind Exposure Classification: C Adjustment Factor for Exposure & Height: r2I 7. Components & Cladding Wind Pressure on Roof Zone 1_� 11L,_?__J0'- —3_,1 �q pSN 8. Components & Cladding Wind Pressure on Wall Zone 4 4z. 4.-L-s+42,-7/-s7a i inw, 9. Components & Cladding wind Pressure on Overhead Garage Door_. 1L ^^—PSF 10. Loads: Floor-4 PSF Root%deod —9,1�--PSF Root%Bve 1y7,,PSF 11. Shear Walls Considered for Structure?. Yes �—Q No _ (if No, attach explauutiunjo 12. Continuous load Path provided? Yes No _ (if No, attach explanation) 13. Are Component and Cladding Details Provided? Yes CC No _ (ir No, attach 14. Minimum Soil Bearing Pressure: � P* Ptesumptivc: ^ By Test: PSF As a itnessed by my seat, I hereby certify that the information included with, this cectiricatfuu is true and cocrect, to the best of my knowledge and belief. Naar; PAUL WELCH P.E. Cert#: 29945 S)tsign Films: PAW- WEL04 MC Dan: AUG 1 9 2010 SAXVDV Form # U2v f)t? ntevrsed 511811)9 (('L) SEAL n1;