Loading...
HomeMy WebLinkAboutDESIGN CALCULATIONSSeals easyseals.com SCANNED By St. Lucie County DESIGN CALCULATIONS FOR WE ROCK THE SPECTRUM KIDS GYM WALL -MOUNTED SIGNS °COPY 7115 S US Hwy — Port St Lucie \\ /� DE GO �p+L1A��� GENERAL NOTES: vO . Loom Coin 1. Design is in accordance with the Florida Building Code 6th Edition (2017) S BOCC for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements ofASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The Index: existing host structure (if any) is assumed to be in good condition, Pg 1 Cover capable of supporting the loaded system, subject to building department Pg 2 Wind Loads approval. No warranty, either expressed or implied, is contained herein. Pg 3 Anchor Design 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be "WAbTr � y Eng;�e��Bt�iJ `a_t�4sealvalid required or a separate site -specific engineering evaluation performed. t 6. Aluminum components in contact with steel or embedded in concrete ` �sF • 'tn (� •..G shall be protected as prescribed in the 2015 Aluminum Design Manual, No. 67 8 Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. ,;50'- 02 4V 05 Use of this specification by contractor, et. Al, indemnifies and saves CPI ISj:la Rom# 67382 harmless this engineer for all costs & damages including legal fees & •��G.i apellate fees resulting from deviation from this design. Easy Se�19.1t1;t.�ert,Auth # 31124 1200 N Federal Hwy, #200 I` Boca Raton, FL 33432 Easy Seal .com Page 1 0 EasySeals �1.I CALCULATIO '"'FOR WALL -MOUNTED SIGNS /SCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 160 mph Basic wind speed Exposure C Calculations a = 9.5 3-sec gust speed power law exponent zg = 900' Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff 160 mph - Exp "C" WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER HEIGHT (Zone 4) (Zone 5) 15 ft 31.2 psf 39.7 psf 20 ft 33.2 psf 42.2 psf 25 ft 34.8 psf 44.2 psf 30 ft 36.1 psf ;' 46.0 psf 35 ft 37.3 psf 47.5 psf 40 ft 38.4 psf 48.8 psf 45 ft 39.3 psf 50.1 psf 50 ft 40.2 psf 51.2 psf 55 ft 41.0 psf 52.2 psf 60 ft 41.8 psf 53.2 psf 70 ft 35.3 psf 70.6 psf 80 ft 36.3 psf 72.6 psf Soft 37.2 psf 74.5 psf 100 ft 38.1 psf 76.1 psf 110 ft 38.8 psf 77.7 psf 120 ft 39.6 psf 79.1 psf 130 ft 40.2 psf 80.5 psf 140 ft 40.9 psf 81.7 psf 0 ft 41.5 psf 82.9 psf 5 ft 42.8 psf 85.7 psf 0 ft L25 44.1 psf 88.1 psf 00 ft 46.2 psf 92.3 psf ASD Load Combo Coeff: 0.6 Kd= 0.85 Directionalityfactor Kzt = 1.0 Topographic factor A = 10 sq ft Tributary area n N Y Y qx n _ U U a U (9 0.85 47.3 -1.10 -1.40 0.90 50.2 -1.10 -1.40 0.95 52.7 -1.10 -1.40 0.98 54.7 -1.10 -1.40 1.01 56.5 -1.10 -1.40 1.04 58.1 -1.10 -1.40 1.07 59.6 -1.10 -1.40 1.09 60.9 -1.10 -1.40 1.12 62.2 -1.10 -1.40 1.14 63.3 -1.10 -1.40 1.17 65.4 -0.90 -1.80- 1.21 67.3 -0.90 -1.80 1.24 69.0 -0.90 -1.80 1.27 70.5 -0.90 -1.80 1.29 71.9 -0.90 -1.80 1.32 73.3 -0.90 -1.80 1.34 74.5 -0.90 -1.80 1.36 75.7 -0.90 -1.80 1.38 76.8 -0.90 -1.80 1.42 79.3 -0.90 -1.80 1.46 81.6 -0.90 -1.80 1.53 85.5 -0.90 -1.80 Page 2 EdsySeaLs — - Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: CALCULATIO FOR WALL -MOUNTED SIGNS P = 46.0 psf Channel Letter A = 7.3 sqft (per letter, critical) Wall material: Masonry (ASTM C90, 1,500 psi min) Anchor type/size: 3/16" (#10) Rods with Adhesive Ref: Liquid Nails, 125 psi shear Min Embedment: 1.5" Min edge dist: 3" Min Spacing: 3" Anchor tensile capacity: Tcap = 110.4 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 334 lb ... = P*A (per letter) No. of anchors req'd: n = 3.0 anchors per letter ... = Rt/cap Total anchors required: 3 anchors per letter OK, critical letter size shown. Limit to min (4) per letter at "KID'S GYM", min (3) per letter otherwise, bal. Page 3