HomeMy WebLinkAboutDRAWINGSCANNED
BY
St. Lucie County
'Lo . rit
GYPSUM WALLBOARD, STEEL STUDS
One layer ale type X gypsum wallboard or gypsum veneer base applied parallel or at right
angles to each side of 35/su steel studs 24° o.o. with 1 ° Type S drywall screws 8" o.d. at
vertical Joints and 12" o.c. at floor and calling runners and intermediate studs.
Joints staggered 24" on opposite sides. (NLB)
IFS
r►
kirr
s
Thickness: 41/e"
Limiting Height Refer to Section IV
Approx. Weight: 6 psf
Fire Test FM WP-45, 6-19.68;
OSU T-1770, 8-61;
ULC 79T484, 79T500,
79T497, 8-12.81,
ULC Design W415 .
Sound Test NGC 2385, 7-28-70'
lei
Scope of Work: ' -'--
- .
Work consists of removing existing door and provide one hour fire rated infdl at 10548 US
Mghway One, Port St Lucie, FL. Door exists between two occupied tenant bays and serves to
increase security at each tenant bay.
Wind Certification -Design Criteria
-
These plans are designed to the following standards
Florida Building Code 2017��'
2011 NEC
p
ps�tti� l21?O�y
Wind Speed -165MPH Vult
"C"
Exposure ..
Structure Is enclosed
pd
Co ,.
��tY opt
Internal Pressure Coefficient+/_.18
Building Category H Importance Factor 1.0
General Notes
All work to be performed by licensed, insured contractors in accordance with all applicable
codes and ordinances -
Typical Construction
Remove existing door, and provide 3 518" metal studs (with R13 sound batt) 24" on center in
remaining opening. Provide (1) layer 5/8" "X" board each side as per GA file number WP
1200
Fk Ae� C0;'1,
S "6 Q .. Fire Rated
i'CIE DO sting Door
031v %481iighway One
St. Lucie, FL
Joseph P. McCarty, Architect, Inc.
U ;
900 East. Osceola Street
Stuart, FL 34994
DBPR registration 9639
u
r
GYPSUM WALLBOARD, STEEL STUDS
One layer s/e" type X gypsum wallboard or gypsum veneer base applied parallel or at right
angles to each side of 3W steel studs 240 o.c. with 1" Type S drywall screws 8" o.d. at
vertical joints and 12" o.c. at floor and ceiling runners and intermediate studs.
Joints staggered 24" on opposite sides. (NLB)
r
' FIRE Sb[IND v
Scope of Work:
Work consists of removing existing door and provide one hour fire rated infill at 10548 US
Ilighway One, Port St Lucie, FL. Door exists between two occupied tenant bays and serves to
..
increase security at each tenant bay.
c}lo
OCl2
Wind Certification — Design Criteria at,
These plans are designed to the following standards
Florida Building Code 2017 llh
PO�
Thickness:
47le"
2011 NEC PCu
Limiting Height:
Refer to Section IV '
Wind Speed -165 MPH V ult ')>0
Approx. Weight:
6pal
Exposure"C"
Fire Test
FM WP45, 6-19.68;
Structure is enclosed
OSUT-177018-61;
Internal Pressure Coefficient+/-.18
ULC 79T484, 79T500,
Building Category H Importance Factor 1.0
79T497,8-12-81,
ULC Design W415 ,
Sound Test.,
NGC 2385, 7-28-70'
General Notes
All work to be performed by licensed, insured contractors in accordance with all applicable
codes and ordinances
Typical Construction
.
Remove existing door, and provide 3 518" metal studs (with R13 sound batt) 241' on center in
'
remaining opening. Provide (1) layer 5/8" "X" board each side as per GA file number WP
1200
our Fire Rated
f Existing Door
S Highway One
St. Lucie, FL
Joseph P. McCarty, Architect, Inc.
900 East. Osceola Street
Stuart, FL 34994
DBPR registration 9639
0