Loading...
HomeMy WebLinkAboutDRAWINGSCANNED BY St. Lucie County 'Lo . rit GYPSUM WALLBOARD, STEEL STUDS One layer ale type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 35/su steel studs 24° o.o. with 1 ° Type S drywall screws 8" o.d. at vertical Joints and 12" o.c. at floor and calling runners and intermediate studs. Joints staggered 24" on opposite sides. (NLB) IFS r► kirr s Thickness: 41/e" Limiting Height Refer to Section IV Approx. Weight: 6 psf Fire Test FM WP-45, 6-19.68; OSU T-1770, 8-61; ULC 79T484, 79T500, 79T497, 8-12.81, ULC Design W415 . Sound Test NGC 2385, 7-28-70' lei Scope of Work: ' -'-- - . Work consists of removing existing door and provide one hour fire rated infdl at 10548 US Mghway One, Port St Lucie, FL. Door exists between two occupied tenant bays and serves to increase security at each tenant bay. Wind Certification -Design Criteria - These plans are designed to the following standards Florida Building Code 2017��' 2011 NEC p ps�tti� l21?O�y Wind Speed -165MPH Vult "C" Exposure .. Structure Is enclosed pd Co ,. ��tY opt Internal Pressure Coefficient+/_.18 Building Category H Importance Factor 1.0 General Notes All work to be performed by licensed, insured contractors in accordance with all applicable codes and ordinances - Typical Construction Remove existing door, and provide 3 518" metal studs (with R13 sound batt) 24" on center in remaining opening. Provide (1) layer 5/8" "X" board each side as per GA file number WP 1200 Fk Ae� C0;'1, S "6 Q .. Fire Rated i'CIE DO sting Door 031v %481iighway One St. Lucie, FL Joseph P. McCarty, Architect, Inc. U ; 900 East. Osceola Street Stuart, FL 34994 DBPR registration 9639 u r GYPSUM WALLBOARD, STEEL STUDS One layer s/e" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 3W steel studs 240 o.c. with 1" Type S drywall screws 8" o.d. at vertical joints and 12" o.c. at floor and ceiling runners and intermediate studs. Joints staggered 24" on opposite sides. (NLB) r ' FIRE Sb[IND v Scope of Work: Work consists of removing existing door and provide one hour fire rated infill at 10548 US Ilighway One, Port St Lucie, FL. Door exists between two occupied tenant bays and serves to .. increase security at each tenant bay. c}lo OCl2 Wind Certification — Design Criteria at, These plans are designed to the following standards Florida Building Code 2017 llh PO� Thickness: 47le" 2011 NEC PCu Limiting Height: Refer to Section IV ' Wind Speed -165 MPH V ult ')>0 Approx. Weight: 6pal Exposure"C" Fire Test FM WP45, 6-19.68; Structure is enclosed OSUT-177018-61; Internal Pressure Coefficient+/-.18 ULC 79T484, 79T500, Building Category H Importance Factor 1.0 79T497,8-12-81, ULC Design W415 , Sound Test., NGC 2385, 7-28-70' General Notes All work to be performed by licensed, insured contractors in accordance with all applicable codes and ordinances Typical Construction . Remove existing door, and provide 3 518" metal studs (with R13 sound batt) 241' on center in ' remaining opening. Provide (1) layer 5/8" "X" board each side as per GA file number WP 1200 our Fire Rated f Existing Door S Highway One St. Lucie, FL Joseph P. McCarty, Architect, Inc. 900 East. Osceola Street Stuart, FL 34994 DBPR registration 9639 0