NEVILLE RESIDENCE
SCANNED
BY
St. Lucie County
SCOPE OF WORK
1. MOBILIZE
2. REMOVE & DISCARD EXISTING DOOR
3. INSTALL NEW DOOR PER PLANS
4. DEMOBILIZE
GENERAL NOTES:
CODES AND STANDARDS
1. THE PROJECT WAS DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:
1.1. FLORIDA BUILDING CODE, BUILDING & EXISTING; 6TH EDITION; 2017, ASCE 7-10, ASO, &
AISC
2. DRAWING NOTES:
2.1. BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK, THE CONTRACTOR SHALL
VERIFY ALL MEASUREMENTS TO PROPERLY SIZE OR AT THE WORK. NO EXTRA CHARGE
OR COMPENSATION WILL BE ALLOWED BY THE OWNER RESULTING FROM THE
CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT.
2.2. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND
ENGINEER BEFORE PROCEEDING WITH ANY WORK.
3. SECTIONS AND DETAILS:
3.1. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWINGS ARE INTENDED TO BE
TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE
SHOWN.
4. SUBMIT SHOP DRAWINGS AS REQUIRED. ALL SUBMITTALS SHALL BE CHECKED AND SIGNED BY
THE GENERAL CONTRACTOR AND SIGNED AND SEALED BY THE DELEGATED ENGINEER.
5. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWING
THE CONTRACTOR SHALL NOTIFY THE ENGINEER -OF -RECORD IN WRITING OF SUCH
OMISSIONS OR ERRORS PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION.
IN THE EVENT THE CONTRACTOR'S FAILING TO GIVE SUCH NOTICE, HE SHALL BE HELD
RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF
RECTIFYING THE SAME.
6. INFORMATION FOR THE LAYOUT AND DESIGN OF THESE PLANS WERE EXTRACTED FROM
FIELD MEASUREMENTS AND EXISTING DRAWINGS.
CONTRACTOR SHALL INSPECT EXISTING FIELD CONDITIONS TO ENSURE PRESENT INFORMATION
ON PLANS MATCH. IF EXISTING CONDITIONS DIFFER FROM PLANS, "GENERAL" NOTE I ABOVE ,
SHALL ALSO APPLY.
DEMOLITION:
1. PRIOR TO COMMENCEMENT OF DEMOLITION THE CONTRACTOR WILL COORDINATE HIS
ACTIVITIES WITH ALL THE APPROPRIATE SUB -CONTRACTORS AFFECTED BY THIS AREA.
2. THE CONTRACTOR IS TO COMPLETELY REMOVE AND DISPOSE OF ALL MATERIALS
THAT ARE SO INDICATED INCLUDING CONCRETE AND WOOD.
3. THE LOCATION OF ALL EXISTING UTILITIES ARE THE CONTRACTOR'S RESPONSIBILITY.
THE ENGINEER ASSUMES NO RESPONSIBILITY FOR EXACT LOCATIONS. PRIOR TO THE
START OF DEMOLITION THE CONTRACTOR SHALL VISIT THE SITE AND DETERMINE THE
LOCATION AND THE EXISTENCE OF ALL STRUCTURES AND UTILITIES SHOWN OR NOT ON
THE PUNS.
NEW DOOR
LOCATION MAP
NOT TO SCALE
BUILDING EXISTING NOTES:
1. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND BE AWARE OF ALL EXISTING
CONDITIONS AND INTERFERENCES.
2. THE CONTRACTOR SHALL CHECK CONDITION FOR EXISTING WIRING INSULATION AND NOTIFY THE
OWNER, ARCHITECT, OR ENGINEER OF ANY DANGEROUS CONDITIONS.
3. THE CONTRACTOR IS TO COMPLETELY REMOVE AND DISPOSE OF ALL ITEMS AND THAT ARE SO
INDICATED ON THE PLANS WITH THE OWNERS APPROVAL.
4. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HAVING VISITED THE SITE AND HAVING
FAMILIARIZED HIMSELF WITH ALL EXISTING CONDITIONS. ANY QUESTIONS OR DISCREPANCIES
FOUND WITH REGARD TO THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE
BUILDING ENGINEER BEFORE SUBMITTING A PROPOSAL FIELD MEASURE EXISTING CONDITIONS
PRIOR TO FABRICATION OF ALL MATERIALS.
5. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE FIELD
VERIFIED BY THE CONTRACTOR.
6. IF MATERIALS, QUANTITIES, STRENGTHS OR SIZES INDICATED BY THE DRAWINGS OR
SPECIFICATIONS ARE NOT IN AGREEMENT WITH THESE NOTES, THE BETTER
QUALITY AND/OR GREATER QUANTITY, STRENGTH OR SIZE INDICATED, SPECIFIED
OR NOTED SHALL BE PROVIDED AND APPROVED BY EOR.
DIMENSIONS:
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON JOB SITE WITH COMPLETE SET OF LATEST
DRAWINGS. NOTES AND DIMENSIONS SHALL BE CHECKED AND VERIFIED WITH ARCHITECTURAL
AND STRUCTURAL DRAWINGS. ANY DISCREPANCIES IN NOTES OR DIMENSIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE COMMENCING WORK SO THAT PROPER
WORK CAN BE EXECUTED. DO NOT ASSUME OR GUESS ANY DIM. OR ELEMENTS
CONNECTIONS AND ELEVATIONS.
2. UNLESS SPECIFICALLY DETAILED ON THESE DRAWINGS, CONTRACTOR SHALL FURNISH AND
INSTALL
ADEQUATE SHORING, BRACING, ETC. REQUIRED TO SAFELY SUPPORT ALL CONSTRUCTION LOADS AND
SHALL BE FULLY RESPONSIBLE FOR THE SAME. SHORING MUST COMPLY WITH ALL LOCAL AND
OSHA REQUIREMENTS.
3. DETAILS AND CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN ACCORDANCE
WITH DETAILS SHOWN FOR SIMILAR CONDITIONS AND MATERIAL
zt
A _
N
KEY- BUILDING FOOTPRINT
NOT TO SCALE
STRUCTURAL DESIGN CRITERIA:
THE DESIGN COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING &
EXISTING; 6TH EDITION; 2017, ASCE 7-10, & ASO
MEAN ROOF HEIGHT
WIND LOAD
WIND VELOCITY
WIND VELOCITY
EXPOSURE
Qz
Kd
Kz
REDUCTION FACTOR
ROOF SLOPE
LOAD COMBINATIONS
INTERNAL PRESSURE COEFFICIENT
RISK CATEGORY II
OCCUPANCY
CONSTRUCTION TYPE
200'
FBC 2017 & CHAPTERS 1, 2, 26,
& 28 OF ASCE 7-10
165 MPH; ULTIMATE WIND SPEED
128 MPH; NOMINAL WIND SPEED
"D'; ENCLOSED DESIGN
96 PSF
0.85
1.61
0.6
FLAT
ASCE 7-10 CHAPTER 2.4: DL+LL;
0.6DL+0.6WL
+/-0.18 PER TABLE 26.11-1
RESIDENTIAL
V
GENERAL COMPONENTS AND CLADDING
ZONE 5 AND MEET THE DESIGN PRESSURES STATED
ZONE
I 7RIRlRARf
DOOR
WIND
AREA
TYPE
ESSUE
WwT
1 lasts
9
1M wT
1 4
iRx/-RI
DL+0.6WL;
610 - 01%
File.Copd
1 • E
�®E 00
E ��l
SHEET
DESCRIPTION
S-1 COVER SHEET & NOTES
S-2 UNIT LAYOUT & SCHEDULE
S-3 DETAILS
S-4 NOA PRODUCT APPROVALS
TOTAL - 4
NEW DOOR
NEVILLE RESIDENCE
ISLANDIA CONDO
9550 S OCEAN DR, UNIT 1405
JENSEN BEACH, FL 34957
rm s m
ENGINEERING
CIVIL • STRUCTURAL • MARINE
CSM ENGINEERING, LLC
2OS SW 0CEAN BOULEVARD
STUART, FLORIDA 34994
772.220-4601
WwW CSM-E.NET
CERTIFICATE OFAUTHORIZATION: Z9057
TIE BITf➢i xSxHT BO'lIRm4Y 183m4 HSABI OxOQI
W fWlmRR xB MRR RxHRiT BOAS P6E RN6 /!OI
MOILS xa W m BE 1EPROMCED, OM GM MPIA OR
♦� m xa 1w.m wRD x xn R1O M IL91ER
Bl9mBfR xmDR FEET MLOUS BARE xRRd
FN DE
Rld®1 N0 fB&M ff C91 AEBBIG, UL
m6 OOOIFN[ iiff ffIs ILO ff3R6 xasorAim IRmIL
AS xl 161R1QR ff PBRFS$VL 4mS{ 6 ROEWIY ff
m BmhBAx' uc xm s 1or m a Isa a xxDF M a
RAm RR xm anuR ERLo-cr xnsur LIR ewnLn
NmORVd ff CRI BElRBRL, IlG
C91 BmmBOG, TIC DWRRR =15
PERMIT SET
10-17-19
NOI6 & WYYENIS
aL mmsxs svu a W'RRD x mE FELD Rr 1xL
NxIRW90R. 11E NNIP.WTM B IiW®E RR mE
owRxanx ff xL Mmaes
RU scvs ImrA101 m2ua ro nxls ROR
RSD® B: DRnD am
Max B:
Dm>Rn Rr. DFRB am
rae a Rar
RRECf k
\V111111111TT/
N. DA
No,76910, -_
��O`•. STATE OF
i/
1
CHAHES A DNDBI JR
MTE
ROM®�ROOFLR
n1xR
COVER SHEET & NOTES
sa k
S-1
EXISTING UNIT FOOTPRINT
SCALE: 1/8" = 1'—O"
DOOR SCHEDULE:
DESIGNATION
APPRO% OPENING
SIZE (WRH)
TYPE
QUANTITY
REMARKS
MANUFACTURER
PRODUCT
APPROVAL N0.
EVALUATION
AGENCY
EXPIRATION
DATE
MAX. DESIGN
PRESSURE
EXTERIOR:
[11
1 IM5
SLEQlC OIm
3
DOUBLE VANE OD'ACT
I
NOA 17-12I621
IDAIB OADE1
1R-2F=q
W I -160 PS
of, ('f
-rue C°p3'
NEW DOUR
NEVILLE RESIDENCE
ISLANDIA CONDO
9550 S OCEAN DR, UNIT 1405
JENSEN BEACH, FL 34957
rm ms m
ENGINEERING
CIVIL • STRUCTURAL • MARINE
CSM ENGINEERING, LLC
208 BIN OCEAN BOULEVARD
STUART, FLORIDA 34994
772.220-4601
W .CSM-E.NET
CERTIFlCATE OFAUTHORIZATION: 29057
PIE BRfEi HRE7OPA34T IIBBMS IFAER dIORI
W fDVIHiR NB OEIX REHmY EREES RESE RMS"
OP/aNs I12 txf m ff RRiml1'ID, tlW1®, D1PELl OR
•� m AYl nw ERRrc x eR faRl aR RnER
RwomBTR nnDur R6f OEDtac nc DPi4 BEfIFN
PDa®x NEI OW411T rt CEI DEEiB1USRb, IIG
lIa D]OIENI; IIE QAS Ilx DFSIa6 lIOa6DPARD NDREL
u a xsnaEnrt v FI91Ea�W. SeR1LE a RCRmT a
m DLunms, uc xm s xm m a Isla x xIDE a x
PNIf RR Ntl 11E fRTEN
EC9®3A
OF ON BRiOL,
x1110EZ9O16 UG
U
ON DEN]MC UD alRtaiE =15
mm & COINQNI6
ALL OEE]@a 9Wl � RIO®x TE HID of TE
RNOLW'IOL 110 OlI1RACl0t a k.40®E flR 11E
NDI✓DELVW W NL LIE]®S
ALL Ala xTfAm RRD31 m 11k17 H015
®m) EN awa ven
D RR
DBiID BC area aml
siEe A Rar
Ra6T k
\\�111111111/T��'
J4
..
L .........
FR0,
� Q`..• G_EM1S �
•��\�
No:,76$10,. —_
��Q '• STATE OF,
�'.c�•.•• F{O OP .,: G�?N
CR4DiS 611E
UNIT LAYOUT & SCHEDULE
Ertrk
S-2
1/2" GYPSUM WOOD BOARD
PT. WOOD FURRING (AS REQ'D)
PT. WOOD BLOCKING
PER PLANS (AS REQ'D)
WINDOW/DOOR FRAME PER PLANS
PROPOSED WINDOW DOOR
(SEE PLAN FOR SI E)
RUM
-LASHING/SEALANT SHALL EXTEND TO THE SURFACE
)F THE EXTERIOR WALL FINISH AND SELF —ADHERED
LASHING SHALL COMPLY WITH AAMA 711.
STUCCO FINISH
8" C.M.U. PER PLANS
CONC. FILLED CELL.
TYPICALL WINDOW/DOOR JAMB FLASHING DETAIL
SCALE: N.T.S.
BUCK INSTALLATION NOTES (AS REQ'D)
1. WINDOW OR DOOR BUCK FASTENING DETAILS TO MATCH OR EXCEED THE MANUFACTURER'S TEST
APPROVALS AND RECOMMENDATIONS.
2. WINDOW BUCKS ARE DESIGNED FOR WIND LOAD COMPLIANCE ONLY. ANY ADDITIONAL FASTENERS
OR BUCKING REQUIRED FOR IMPACT RESISTANCE ARE TO BE SPECIFIED BY THE SPECIALTY
ENGINEER FOR THE WINDOW MANUFACTURER IN ACCORDANCE WITH FLORIDA BUILDING CODE, BUILDING
& EXISTING; 6TH EDITION; 2017
3. WINDOW BUCKS ARE TO BE iX6 OR 1xB, #2 S.Y. PINE, P.T. PER INDUSTRY STANDARDS.
BUCKS ARE TO BE FULLY BONDED TO MASONRY W/ SIKA 1A CONSTRUCTION ADHESIVE. FOR
DOUBLE BUCK INSTALLATION, BUCKS ARE TO BE FULLY BONDED TO EACH OTHER.
4. FASTENERS ARE TO BE 1/4°0 TAPCONS WITH MINIMUM PENETRATION OF 1 3/4" INTO
CONCRETE USE STAGGERED SPACING OF TAPCONS EQUAL TO, OR EKCEEDING REQUIRED
FASTENERS SPECIFIED BY MANUFACTURER FOR FRAME TO BUCK INSTALLATION.
5. BUCKS TO BE FASTENED HORIZONTALLY AND VERTICALLY TO CONCRETE BEAMS AND
COLUMNS OR CONCRETE FILLED MASONRY. CONTRACTOR TO COORDINATE OPENING
DIMENSIONS.
uemRiov nD nn.IDr
7
- - olnv
WINDOW/DOOR BUCK ANCHORAGE
NEW DOOR
NEVILLE RESIDENCE
ISLANDIA CONDO
9550 S OCEAN DR, UNIT 1405
JENSEN BEACH, FL 34957
rm s m
ENGINEERING
CIVIL • STRUCTURAL • MARINE
CSM ENGINEERING, LLC
2L1B 6W CCEAN BOULEVARD
STUART, FLORIoA 34994
772.220-46DI
W .CSM-E.NET
CERTIFICATE CIFALTTRORIZATICN: 29057
m 8R9SiY IR@8l DAY PF9.iBS f6AFP DAKmx
wE
Us Aw MRx mmRRR IDMS Its mms mm
KANmS xE RKr m RE aL ' of ' m
A90eD m.wflIWPA wwmIsm1
wwmBTR mmmKl R6f mwmK mRDW
N
RA®lllm mt®LI KT C91 Biifsml'M Lit
mw .uEEDLCm0R taxmffam mmi
M AI RSIRRENf W TIet6 L som s YRffQItt IT
CL BRs®m4 u0 m6 s wf m ff Isn w wCIE w N
NM mR AW RRIOIR 1K RmRsl
w BUR
xrtwmanl mL BRiRFImIIn ue
m vnm.�r uc �lrwf Rmts
NOI6 k WI6R7lIS
M
6 RaAlm RRDTI m IIYIY R015
KEW®RI: awt5 Dm�l
021YN BY:
DD7,ID 9F. aRm¢ KwCI
SLYE s svm
Rm[cf k
A. DA b
' 1GENS
e Na:76910•
ON L
fC 6
A BUZDEN JR 841E
Ranr, m>mmm lm®amm ntmo
DETAILS
RmR
S-3
MIAMFDADE I MIArvR-DARE COUNTY
WE PRODUCT CONTROL SECTION
DEPARTIIIENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
EGS International, LLC
3133 S.W. 25`D Street
Pembroke Park, FL 33009
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product cr material within their jurisdiction. RER reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Atlantic Series Aluminlan Sliding Glass Door- S.M.I.
APPROVAL DOCUMENT: Drawing No. W04-80 Rev I, titled "Atlantic Series SM 130 Alum Sliding Glass
Door", sheets 1 through 8 of 8, prepared by AL-Farooq Corporation, dated 09/10/04 and last revised on DEC 07,
2017, signed and sealed by Javad Ahmed, P.E., bearing the Miami -Dade County Product Control Revision stamp
with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Small Missile Impact Resistant
Limitations:
1. See Design Pressure (DP) ratings with glass types & Reinforcing in sheet 2. See DP ratings of anchor types in
sheet 3. Lower Design Pressure Ratings shall apply to entire system. Positive (Exterior) DP shall be limited to
sill height per sheet 2.
2. The total tested frame area must not exceed 180 sq. fL per FBC requirements.
3. All SOD doors containing operable panel (I) require channel reinforcement (item #31) at Bottom Rm1s.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, me del/series,
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at thejob site at the request of' the Budding Official.
This NOA revises NOA #14-0807.18 and consists of this page I and evidence pages E-1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Ishaq L Chanda, P.E.
I•RrwEbAOEcouNTv NOA No. 17-1218.21
Expiration Date: December 24, 2019
( M Approval Date: February 15, 2018
s1,$ Page 1
mR IOAM
avacm
-
m mural
lom ceR.arr - r �tu�)
Ira w
1�:% I�
A
R"M na
ru
./o
muav
Ye�m6na
sa�mnm �mn
f• - -
Q SM
6 �alR
'/•
IDy/•
_ _ "RIM;o,OS CMAGIIEs 0.r rx;s sW2r ARE
MCC ON ASN E1J00-09 (J SEC W.)
- - Axo ROXIW. eUlLC WMMR ON
- - DEDV0o0RI VAoNM Da°s-Ds-219
` �5�teg
O �O �
a e g99
Qa�
mo
V•-rtAi irvwn a.m Ml.)
J D
one
-
na/4
RurtL x0cvr -won xzaR - a
Im,mnA,vl emml rmxs.w°Mm) 8�
� >v�; d
Il rtCnJ 11
tir�4rf.£I
PC• -
ID
411ZEbf. oFTArr. C_C 07 299
t Q
a
a
1 i ri
woo-80
-
-IIID
IlI.R
pRAL„
w, f ar a 51
MANUFACTURER WIND PRESSURE CHART
u®.
�n � �® �® .m ME A_ .1'
•®
.m
im
�' Y� MXS °RLn
• °F-s I
z4.
S
O. I s
u x wmw,mn mmoAOOOiaoo'�'
t► mnu ler Bo-¢ iNro mNwert
a p`
1OOVI E
p 31-y
U" ms ID 6.o. m M - w h-t6N c0
¢ Ln Sw
IDID/•
w-ID�/• ll FOR y OR" C°n'6RCIE
DO
1-3/4' Ibu o•.Em
R
rmf'c- I/.-Mw
L.
oF83
wm uvw.E cam mvWrTn ww°is
W
¢ qaf
Mao wp m snmEs twn ---)
rn
I NUlauu: ,%e•ww. �(e°v-,s wl °�O�I
LLbb
; I
�eR
a:®�'e
PI¢ncr inm PoNCREIE�
T9F'A- 6/� muirtnv®w'Flm• 6..-,n we r,-gang
wR0 zsr ua° bxxs OR Nva s vc,urMs
q n
ai l 6 e =
ID
�•/•
-IR' Mw Rnow.noO
xOR , A, a. C MFLILAOIE Ai XEM
+ a
O` {NqU 19, WCMS MO PoXL OR DIMES
xOR ,wE 9.WRK.B�E nr su O. OR
I- ^
w?
1-1/4• Mlx URED INIo OINC. OR BLOOC
..0.
mc•n- 1/4•m. m 1..- .-man
`
FlrYIID
WEd�
bICGITY Mf0 pt BIMIe�
1-1/1 Den I•n0 ¢
ttPf C [G[ 1�1
RIRI
'°1'/•
u°rz"12
p) rn EMm E.Io-e 6 x0 a ,wuaEss
"ro
Nwwuu: IN .(
SIFEL 1/6' MG R. (r, 36 K9 uINI
L_ ryrm wmmn vx xuMiMx maw.m w.rlml J
_.
-
wN1Om mo Iw*'tta'� 1O:w. - 6C 0 7 Vq
MO ubu •1/IvmfS
SI y
cv�•T><.i Ia a au m wn re - x'"`m
:. $'
c-6M muu.num mov n wes rm - zm rs Mw
r
�
:
VI
¢
XL
w04-80
aI M
MANUFACTURER CONNECTION SCHEDULE
File COPY
/a11A-lz i
NEW DOOR
NENLLE RESIDENCE
ISLINDIA CONDO
9550 S OCEAN DR, UNIT 1405
JENSEN BEACH, FL 34957
Crom
ENGINEERING
CIVIL • STRUCTURAL • MARINE
C5M ENGINEERING, LLC
ana SW OCEAN BOULEVARD
STUART, FLCRIOA 34994
772-ZZC-4601
www.CSM-E.NET
CERTIFICATE CFAUTHCRIZATICN: 29057
na aRaRm xsaar nal�r IsmMs ImrtkR mmx
w mFnmR Nm ancR nDPFR1Y awls nRg RAss MR)
DURN6 Re wr m a: RaR1aR0. aDa®. [aaEn. w
Lssv®m Mm twm war N /M' RM01 ce saoDR
WNlmrhli amour rrar asW¢Is TIE Banes xanLel
rva®x Rm mrsoR a L91 Olmra¢4 ue
1I6 mmIDM. 1H:OClC lm R®8 elVarnlRn H9%
As M NSX&IDU OF aOnmll•1 BR,4L 5I'RSFRrf 6'
= e101Maa4 UC Ira 6Im m MUSED. N 114E OR N
RIM f0R INf mmR aNFer RRIgR DE h0IIk11
MaROAI.im W = �=
I � Bo®on uc �rt Daim I
NOTES & mlum
NL OLEIme 3NL a won N na 10D ar nE
D]MR•Clat M fDRmV.Tat 6 RerDI�E fDR 11E
O10axNlC1 6' NL dO9rS
m YInS MGIfD nil¢II m 111171 IURS
Rf.'YYD6014IDI aWR a(:
o:aD W.;Ms¢m
rHc o sus rlosl.T k
\` I i11111111///
No. 76910 r, '
..L
�pQ STATE OF- =
FCORMP�.G\?�
NOA PRODUCT APPROVALS
Rm k
S-4