Loading...
HomeMy WebLinkAboutPLANSrs Master Bath Shower/Tub Area Existing Fire Wall _-`"� Fire Rating ---------- ----- 2 Hr. --- 0 � Design . Z U V488 Z m m Q ; Description ' U C/) —t or Base layer 5/8 in. (15.9 mm) Fire -Shield Gypsum Board } to applied vertically or horizontally to each side of a double row Tub/Shower\ t of 2-1/2 in. (63.6 mm) steel studs 24 in. (610 mm) o.c. \ evenly staggered between the two rows with 1 in. (25.4 mm) Type S or S-12 screws 16 in. (406 mm) o.c. Face layer —� Fire -Shield Gypsum Board applied vertically or horizontally to each side with 1-5/8 in. (41.3 mm) Type S or 5-12 screws 16 in. (406 mm) o.c. Screws offset 8 in. (203 mm) from I screws in base layer. Joints staggered each layer and side. Exhau Fan NOT : Rece* Lights t\ her is no plan to penetrate a rated wall assembly but if neec ed, use detail abv. or match exist. -------------- E I----- \ S S Swing Door • -- ; - ell ---------- B o W N Qp U CD Z € N y a All work to conform to FBC 2017 6th Edition C Cooke Construction, Inc. Scope of Work Job: Mullis Renovation Division Master Bath Shower/Tub Area CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 1 of 3 New Master Bath Shower Area ` Existing Fire Wall _ O 1 1 Recest Lights Shower (Dam Rated) I Remains in Same Location I I Exhaust an I t New Mid/Low Wall I \ (Non -Load Bearing) i Pocket Door Master Bath Shower * Remove Tub & Shower Valves * Convert Tub Drain to Shower Drain (Drain Remains in Same Location) * Install Mid/Low Wall @ Shower (Non -Load Bearing Wall) * Install New Shower Pan & Wall System * Install Shower Valves * Frame & Install New Pocket Door Interior Wall (Non -Load Bearing Wall) * Relocate Light/Fan Switches per Code NOTE: Shower to remain open No Enclosure All work to conform to FBC 2017 6th Edition Ne Mid/Low Wall (No -Load Bearing) G C Cooke Construction, Inc. Scope of Work Job: Mullis Renovation Division Master Bath Shower Area CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 2 of 3 As per ASTM C754 attachment to concrete or masonry will be via er-driven fasteners. Attachment in all substrates, secure runners with -rs located 51mm (2") from each end and spaced max. 600mm (24") o.c. Attachment to post tension slab can be made using power -driven pins.. as long as the pin length is 3/4" or less. The minimum cover requirements for post tension cables should not conflict with a 3/4" pin penetration. Ceiling. Top Plate f ,I� f cl�l ,il -•� II �. Typical Interior Wall i MetallFraming (Floor 'Sill Plate — =� 4 All work to conform to FBC 2017 6th Edition CCooke Construction, Inc. Renovation Division CGC1520585 Business Park Place Phone: (772) 530-0659 FL 34957 Fax: (772) 334-9911 Typical Interior Wall Attachment To Concrete Subfloor & Ceiling Owner: Mullis Address: 10410 S. Ocean Drive #706 Jensen Beach, FL 34957 Job: Mullis Date: October 4, 2019 Drawn By: Nate Cooke Sheet #: 3 of 3 Master Bath Shower/Tub Area j Tuber \\ l 1 / I Recess Lights I jExhust Fan 1 1 1 \\ I I � I — \\ ; Swing Door J 1� All work to conform to FBC 2017 6th Edition C Cooke Construction, Inc. Scope of Work Job: Mullis Renovation Division Master Bath Shower/Tub Area CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 1 of 3 New Master Bath Shower Area \�\ O —, 1 Reces6 Lights Shower (Dame Rated) Remains in Same Location 1 I Exhaust an I t New Mid/Low Wall (Non -Load Bearing) i Pocket Door v` .......... Cooke Construction, Inc. Renovation Division CGC1520585 Master Bath Shower * Remove Tub & Shower Valves * Convert Tub Drain to Shower Drain (Drain Remains in Same Location) * Install Mid/Low wall @ Shower (Non -Load Bearing Wall) * Install New Shower Pan & Wall System * Install Shower Valves * Frame & Install New Pocket Door Interior Wall (Non -Load Bearing Wall) * Relocate Light/Fan Switches per Code NOTE: Shower to remain open No Enclosure All work to conform to FBC 2017 6th Edition Business Park Place Phone: (772) 530-0659 n Beach, FL 34957 Fax: (772) 334-9911 Master Bath Shower Area Owner: Mullis Address: 10410 S. Ocean Drive #706 Jensen Beach, FL 34957 Job: Mullis Date: October 4, 2019 Drawn By: Nate Cooke Sheet#: 2 of 3 Attach Top Plate & Sill Plate w/ Polyurethane Construction Adhesive to Concrete Subfloor & Concrete Ceiling Concrete Ceiling Concrete Subfloor C Cooke Construction, Inc. Renovation Division rom.,o All work to conform to FBC 2017 6th Edition CGC1520585 Business Park Place Phone: (772) 530-0659 n Beach, FL 34957 Fax: (772) 334-9911 Typical Interior Wall Attachment To Concrete Subfloor & Ceiling Owner: Mullis Address: 10410 S. Ocean Drive #706 Jensen Beach, FL 34957 Interior Wall al Framing Job: Mullis Date: October 4, 2019 Drawn By: Nate Cooke Sheet #: 3 of 3 I Master Bath Shower/Tub Area Existing Fire Wall NN SGP�� GO��I`1 Tub/shower\ 1 \ 1 Exhau Fan I Recesls Lights 1 I I I fl I 1 S S Swing Door � 1 / 'Rating!--- 2 Hr. " UUGA V488 Description a Base layer 518 in. (15.9 mm) Fire -Shield Gypsum Board nlied vertically or horizontally to each side of a double row -1/2 in. (63.6 mm) steel studs 24 in, (610 mm) o.c, evenly staggered between the two rows with 1 in. (25.4 mm) Type S or S-12 screws 16 in. (406 mm) o.c. Face layer Fire -Shield Gypsum Board applied vertically or horizontally to each side with 1-5/8 in. (41.3 mm) Type S or S-12 screws 16 in. (406 mm) o.c. Screws offset 8 in. (203 mm) from screws in base layer. Joints staggered each layer and side. is no plan to penetrate a rated wall assembly but if d, use detail abv. or match exist. All work to conform to FBC 2017 6th Edition Cooke Construction, Inc. Scope of Work Job: Mullis Renovation Division Master Bath Shower/Tub Area CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 1 of 3 I New Master Bath Shower Area Existing Fire Wall _- 1 1 Recest Lights Shower (Da mb Rated) I/ Remains in Same Location I I Exhaust an I t New Mid/Low Wall (Non -Load Bearing) I Pocket -Door Master Bath Shower * Remove Tub & Shower Valves ' Convert Tub Drain to Shower Drain (Drain Remains in Same Location) * Install Mid/Low Wall @ Shower (Non -Load Bearing Wall) s Install New Shower Pan & Wall System * Install Shower Valves ` Frame & Install New Pocket Door Interior Wall (Non -Load Bearing Wall) * Relocate Light/Fan Switches per Code NOTE: Shower to remain open No Enclosure All work to conform to FBC 2017 6th Edition Ne Mid/Low Wall (No -Load Bearing) C Cooke Construction, Inc. Scope of Work Job: Mullis Renovation Division Master Bath Shower Area CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 r Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 2 of 3 ---- ..Building is a post tensioned system_ __ , As per ASTM C754 attachment to concrete or masonry will be via __{power -driven fasteners. Attachment in all substrates, secure runners with fasteners located 51mm (2") from each end and spaced max. 600mm (24") o.c. Attachment to post tension slab can be made using power -driven pins.. as long as the pin length is 3/4" or less. The minimum cover requirements for post tension cables should not conflict with a 3/4" pin penetration. All work to conform to FBC 2017 6th Edition Top Plate Cooke Construction, Inc. Typical Interior wall Job: Mullis Renovation Division Attachment To Concrete Subfloor & Ceiling CGC1520585 Owner: Mullis Date: October 4, 2019 1276 Business Park Place Phone: (772) 530-0659 Address: 10410 S. Ocean Drive #706 Drawn By: Nate Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL 34957 Sheet #: 3 of 3 Wall