HomeMy WebLinkAboutONSITE SEWAGE TREATMENT AND DISPOSALCP�C SCANNED
BY PERMIT #:56-SF-1986602
STATE OF FLORIDA St. Lucie County APPLICATION #:AP1431212
DEPARTMENT OF HEALTH DATE PAID:
ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM RECEIVED
RECEIPT #:
OCT 0 4 2019 DOCUMENT#: P2R1252882
CNSTRUCTION PERMIT FOR: OSTDS Existing New ST. Lucie County, Permitting jpee 7i!y( �'7 )� —0018
.PLICANT: (Wallaby's Fabrication)
PROPERTY ADDRESS: 3414 Industrial33rd St Fort Pierce, FL 34946
LOT: 5 BLOCK: 3 SUBDIVISION: Airport Industrial Park
PROPERTY ID #: 1Q2g_5Q1_QQ29-QQQ_� [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAR ID NUb[BER]
i'YSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C_ DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME.• ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND
T [ 1,200 ] GALLONS / GPD SeDtic New CAPACITY
A [ ] GALLONS / GPD CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ 600 ] GALLONS DOSING TANK CAPACITY [82.06 ]GALLONS @[ 6 ]DOSES PER 24 ERS #Pumps [ 1 ]
D [ 613 ] SQUARE FEET Drainfield New SYSTEM
R [ ] SQUARE FEET SYSTEM
A TYPE SYSTEM: [ ] STANDARD [X] FILLED [] MOUND I ]
I CONFIGURATION: [R] TRENCH [ ] BED [ ]
N
F LOCATION OF BEN001ARK: BM top Of Stubout
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
L
D FILL REQUIRED:- 122.001 INCHES
O
T
H
E
R
[ 5.00 1 [1 INCHES FT 111 ABOVE BELOW] BENCHMARK/REFERENCE POINT
[ NCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT
3.00 3 [FI
ling Lift Dosing.
must be certified as suitable for distributing sewage effluent.
BY: MICHAEL W STURR
TITLE: Registered Septic Tank Contractor
APPROVED BY: — /'w" TITLE: Environmental Supervisor I St. Lucie CeD
Dianna 9 May
DATE ISSUED: 09/18/2019 EXPIRATION DATE: 03/18/2021
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC C Page �1 f 3
r
I
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
Ron DeSantis
Mission: Governor
To protect, promote & improve the health Scott A. Rivkees MD
of all people in Florida through integrated State Surgeon General
state, county & community efforts. HEALTH
Vision: To be the Healthiest State in the Nation
,r
September 18, 2019
MICHAEL STUHR (ASHTON SEPTIC TANKS, INC.)
376 CYCLONE Drive
Fort Pierce, FL 34945
RE: Contingency Letter
Application Document No: AP1431212
Centrax Permit Number: 56-SF-1986602
OSTDS Number:
3414 Industrial 33rd St
Fort Pierce, FL 34946
Lot:5 Block:3 Subdivision: Airport Industrial Park
Dear Applicant:
This will acknowledge receipt of an application dated 08/29/2019 for a permit to use an existing
onsite sewage treatment and disposal system located on the above referenced property.
From a review of your completed application, it has been determined
that your existing onsite sewage treatment and disposal system has been out of service
for more than a year and must be brought into compliance with the standards for new
systems before it can be approved for use. In order to proceed with your proposal,
you will need to make application for a new system construction permit and bring your
system into full compliance with 64E-6, Florida Administrative Code.
If you have any questions on this matter, please call our office at (772) 8734931.
Sincerely,
Dianna May, Environmental Supervisor I
Enclosures
cc:
Florida Department of Health v .FloridaHealth.gov
in ST. LUCIE COUNTY TWITTER:HealthyFLA
5150 NW Milner Or, Port Saint Lucie, FL 34983 FACEBOOK:FLDepartmentofHealm
PHONE: (772) 8734931 FAX: (772) 8734893 1 YOUTUBE: fidoh
St. Lucie County Health Department
5150 NW Milner Dr PortSaint Lucie, FL 34983
HMTH
PAYING ON: #•56-SF-1986602 BILL DOC#56-BID-4377444 CONSTRUCTION APPLICATION #: AP1431212
RECEIVED FROM: ASHTON SEPTIC TANKS, INC. (Regist AMOUNT PAID: $ 380.00
PAYMENT FORM: CREDIT CARD 034816 PAYMENT DATE: 08/29/2019
Mill- TO: (Wallaby's Fabrication)
FACILITY NAME:
PROPERTY LOCATION:
3414 Industrial33rd St
Fort Pierce, FL 34946
Lot: 5 Block: 3
Property ID: 1429-501-0029-000-7
EXPLANATION or DESCRIPTION:
QUANTITY
FEE
-1 - Surcharge (All)
1
$
45.00
124 - OSTDS Construction Repair or Mod Site Evaluation
1
$
115.00
126 - OSTDS Construction Permit (New or Mod, Amendment)
1
$
55.00
127 - OSTDS Construction System Inspection
1
$
75.00
131 - OSTDS Construction Application & Existing System E
1
$
50.00
- 139 - OSTDS Application Approval Existing, No Insp
1
$
35.00
128 - OSTDS Construction System Inspection Research Fee
1
$
5.00
RECEIVED BY: MontanezNM AUDIT CONTROL NO. 56-PID-4083255
4 STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
PERMIT NO. (D- SF - I°t&A QOA
DATE PAID: ac, [cl
FEE PAID: 7�"O.00� CC.
RECEIPT # R40--0 �
[� ] New System [ ] Existing System [ ] Holding Tank [ ] Innovative
[f ] Repair [ ] Abandonment [ ] Temporary [ ]
1
"PLICANT: Wallaby's Fabrication
AGENT: Ashton Septic Tanks
MAILING ADDRESS: 376 Cyclone Dr Ft. Pierce, FL 34950
TELEPHONE: 772-216-9827
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
1*zk*)04i 40!•lfiiUl�' 0SrN hY to) .I
LOT: 5
BLOCK: 3 SUBDIVISION:
Airport Industrial
PLATTED:
1950
PROPERTY ID
#: 1429-501-0029-000-7
ZONING: 4100
I/M OR EQUIVALENT: [
Yes ]
PROPERTY SIZE: 1.22 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [,/]<=2000GPD [ 1>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ Yes ] DISTANCE TO SEWER: N/A FT
PROPERTY ADDRESS: 3414 Industrial 33rd St
DIRECTIONS TO PROPERTY: 3414 Industrial 33rd St
BUILDING INFORMATION RESIDENTIAL _ [ I COMMERCIAL
._Unit Type of No. of Building Commercial/Institutional System Design
No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC
1 Metal Fabrication 0 14000 2&employees x 15gal= 390 plus lbay door 100 gal =490
2 490 gal of flow
3
4
[ ] Floor/Equipment Drains [ ] Other (Specify)
SIGNATURE: z3 W DATE: r
DH 4015, 08 09 (Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC Page I of 4
dFTMe
o STATE OF FLORIDA
�` ` DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
�, SITE EVALUATION AND SYSTEM SPECIFICATIONS
� ,2,ss`
PERMIT #•n'-[r]�i�/1i�
APPLICANT: Wallaby's Fabrications AGENT: Ashton Septic Tanks
L-OT:�5 BLOCK: 3 SUBDIVISION: Sunrise Homesites
I
PROPERTY ID # : 1429-501-0029-000-7 [ Tax ID Number ]
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. -COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO. NET USABLE AREA AVAILABLE: 1.22 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 3050 GALLONS PER DAY[RESIDENCES-TABLE I ]
AUTHORIZED SEWAGE. FLOW: 850 GALLONS PER DAY [2500GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: .SWI(')(^.O SQFT UNOBSTRUCTED AREA REQUIRED:__Awgiq SQFT
BENCHMARK/REFERENCE POINT LOCATION: 6 m , o e oL� )Qb V r
ELEVATION OF PROPOSED SYSTEM SITE IS [INCHES ] ABO
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: N/A FT DITCHES/SWALES: 40 FT NORMALLY WET? [ [ YES [✓] NO
WELLS: PUBLIC: N/A FT LIMITED USE: N/A FT PRIVATE: N/A FT NON -POTABLE: N/A FT
BUILDING FOUNDATIONS, 10 FT PROPERTY LINES: 15 FT POTABLE WATER LINES: 40 FT
SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES [✓j NO
10 YEAR FLOOD ELEVATION FOR SITE: N/A FT MSL/NGVD SITE ELEVATION: N/A FT MSL/NGVD
aviu racvc a.... u�rvauleai.ivav oii'a i
MUNSELL #/COLOR
TEXTURE
DEPTH
10 YR 5/2
SAND
0
TO 15
I0YR4/I
SAND
15
To 20
10 YR 5/1
SAND
20
TO 28
10YR3/2
SAND
28
To 44
10 YR 5/3
SAND
44
TO 63
10 YR 5/3
Refusal
63
To 72
TO
TO
TO
-USDA SOIL SERIES: Arents
SOIL PROFILE INFORMATION SITE 2
MONSELL #/COLOR
TEXTURE
DEPTH
10 YR 5/3
SAND
0
TO 16
10YR4/1
SAND
16
TO 23
10 YR 511
SAND
23
TO 29
10 YR 211
SAND
29
TO. 44
10 YR 3/2
SAND
44
TO 65
10 YR 5/3
Refusal
65
To 72
TO
TO
TO
USDA SOIL SERIES: Arents
OBSERVED WATER TABLE:63 INCHES [BELOW EXISTING GRADE. TYPE: [PERCHED ]
ESTIMATED WET SEASON WATER TABLE ELEVATION: 20 INCHES [.BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: I ] YES [✓) NO MOTTLING: I✓1 YES [ ] NO DEPTH:20 INCHES
SOIL TEXTURE/LOADING RATE FOTg SYSTEM SIZING: SAND DEPTH OF EXCAVATION: N/A INCHES
DRAINFIELD CONFIGURATION: IV] TRENCH {At BED [ ] OTHER (SPECIFY)
REMARKS/ADDITIONAL CRITERIA: STRIPPING FOUND FROM 10 YR 411 TO 10 YR 511 AT 20" IN THE SOIL MATRIX 1
SITE EVALUATED BY:
)DATE: /
Dar 4015, 08/09 (Obsolet4 previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 Of 4
c
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION
APPLICANT: Wallaby's Fabrications
PERMIT # 56"5F-R%(o&O)—
CONTRACTOR ASI T'ON SEPTIC TANKS
LOT: 5 BLOCK: 3 SUBDIV: Airport Industrial Park
ID#: 14295010029007
TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC
TANS: CONTRACTOR OR
OTHER CERTIFIED PERSON. SIGN AND SEAL ALL SUBMITTED DOCUMENTS. COMPLETE ALL APPLICABLE ITEMS.
COMPLETE TANK CERTIFICATION BELOW OR NOTE IN REMARKS WHY THE TANKS CANNOT BE
CERTIFIED.
EXISTING TANK INFORMATION �)A�o-n �FXlS • hC -T-m- is
[1050 ] GALLONS SEPTIC TANK LEGEND: N/A MATERIAL: CONC
BAFFLED: I N ]
[ ] GALLONS SEPTIC TANK LEGEND: MATERIAL:
BAFFLED: IY/N ]
[ ] GALLONS GREASE INTERCEPTOR LEGEND: MATERIAL:
[ ] GALLONS DOSING TANK LEGEND: MATERIAL:
# PUMPS:[ ]
pp ��
I CERTIFY THAT THE LISTED TANKS WERE PUMPED ON / / BY
, HAVE
THE VOLUMES SPECIFIED AS DETERMINED BY I DIMENSIONS ], ARE FREE OF OBSERVABLE
DEFECTS OR LEAKS, AND HAVE A [ OUTLET FILTER DEVICE
] INSTALLED.
1
ICE=ED BUSINESS offA, i�:l 1'��1�
SI� URE OF CCONTRACTOR
DAT
EXISTING DRAINFIELD INFORMATION
[300 ] SQUARE FEET PRIMARY DRAINFIELD SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: 30 X10
[ ] SQUARE FEET SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: X
TYPE OF SYSTEM: [✓] STANDARD [ ] FILLED. [ ] MOUND [ j
CONFIGURATION: [ ] TRENCH [✓] BED [ ]
DESIGN: [✓] HEADER [ ] D-BOX [✓] GRAVITY SYSTEM [ ] DOSED SYSTEM
ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE 24 INCHES [BELOW ']
SYSTEM FAILURE AND REPAIR INFORMATION
EIM/1974 ] SYSTEM INSTALLATION DATE
[300 ] GPD ESTIMATED SEWAGE FLOW BASED ON
SITE [ ] DRAINAGE STRUCTURES [
CONDITIONS: [ ] SLOPING PROPERTY I
NATURE OF [ ] HYDRAULIC OVERLOAD
FAI-LURE: [ ] DRAINAGE / RUN OFF
POOL
r� ?P't
TYPE OF WASTE P4 DOMESTIC IV'j COMMERCIAL
[ ] METERED WATER [✓] TABLE 1, 64E-6, FAC
[ ] PATIO / DECK [ j PARKING
[ • ] SOILS [ ✓ ] MAINTENANCE
[ ] ROOTS [ ] WATER TABLE
[ ] SYSTEM DAMAGE
[ ]
FAILURE [ ] SEWAGE ON GROUND ,may. TANK [ ] D BOX/HEADER [✓] DRAINFIELD
SYMPTOM: [ ] PLUMBING BACKUP L ]
•Nr-• •• • r •- �• 1 1� V• iI S'ri G��ls.a
SUBMITTED BY: W TITLE/LICENSESQQ o2`Is DATE:
DH 4015, 08/1 (Obsole es previous editions which may not be used)
Incorporated 4E-6.001, PAC, Page 4 of 4
Lydia Galbraith
From:
May, Dianna S <Dianna.May@flhealth.gov>
Sent:
Tuesday, October 08, 2019 9:22 AM
To:
Lydia Galbraith
Cc:
William Durden
Subject: RE: Wallaby's Fabrication, 3414Industrial 33rd St. Bid. permit 1910-0018
SECURITY WARNING: This email originated from outside the County systems. Please show caution when
clicking links or opening attachments unless you recognize the sender and know the content is safe.
Questions, call Customer Service at 772-462-2146.
Good morning Lydia,
I apologize for the delayed response. After reviewing the application, this particular facility is not sized on the square
footage of the building- Instead it was sized based on the number of employees and 1 bay door. The permit did include
the additional 9,405 sf addition, itjust wasn't indicated on the application page because that's not what the drainfield
sizing was based on. I know this is a bit confusing, but he proposed addition is covered in the permit #56-SF-1986602.
If you have any questions, just let me know.
Thanks,
Dianna May
Environmental Supervisor
Florida Department of Health -St Lucie County
Division of Environmental Health
3855 South US 1, Fort Pierce, FL 34982
MAILING: 5150 NW Milner Dr, Port St Lucie, FI34983
Office (772) 873-4896
Cell (772) 370-9330
Mission: To protect, promote & improve the health of all people in Florida through integrated state, county, &
community efforts.
Vision: To be the Healthiest State in the Nation
NOTE: Florida has a very broad public records law. Most written communications to or from state officials regarding state
'business are public records available to the public and media upon request. Your email communication may therefore be
subject to public disclosure.
How are we doing? Please take our survey!
From: Lydia Galbraith <galbraithl@stlucieco.org>
Sent: Monday, October 7, 2019 5:06 PM
To: May, Dianna S <Dianna.May@flhealth.gov>
Cc: William Durden <DurdenW@stlucieco.org>
Subject: RE: Wallaby's Fabrication, 3414 Industrial 33rd St. Bid. permit 1910-0018
Good afternoon Dianna,
Did you have a chance to look at this situation?
Thank you,
-Lydia Ga(braith,
Zoning Specialist
Building and Code Regulation
(77,)) 462-1555
galbraithl@stlucieco.org
20?6= EST
How
From: Lydia Galbraith
Sent: Friday, October 04, 2019 11:36 AM
To: Dianna.Mav@flhealth.gov
Cc: William Durden <DurdenW@stlucieco.org>
Subject: Wallaby's Fabrication, 3414 Industrial 33rd St. Bld. permit 1910-0018
Good morning Dianna,
Currently we are reviewing the building permit for the metal building addition to above site. The existing building is
14,230 sf, the proposed addition is 9,405 sf. The proposed metal building addition is for a warehouse and has a
bathroom in it as well. We have received a copy of the Health Department permit with stamped floor plan and site plan.
The septic permit is indicating a 14,000 sf. However, the additional 9,405 seems not to be included. The floor plan
stamped for approval only includes the existing building while the site plan does include the proposed building.
Please advise if the permit is covering the proposed addition of 9,405 sf, and if not will they need to apply for an
additional permit?
Thank you,
Lydia GaCbraitfi,
Zoning Specialist
Building and Code Regulation
(772)462-1555
ralbraithl@stlucieco.org
20-16_- 2ot[l
PEST
° p ates
to wot)t,
6T. �UC�C G6UNSY
How are we doing? Submit your feedback to
Melissa Brubaker, Supervisor, at BrubakermPstlucieco.org
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Ple: se Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal Inspection, examination and t
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.