Loading...
HomeMy WebLinkAboutONSITE SEWAGE TREATMENT AND DISPOSALCP�C SCANNED BY PERMIT #:56-SF-1986602 STATE OF FLORIDA St. Lucie County APPLICATION #:AP1431212 DEPARTMENT OF HEALTH DATE PAID: ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM RECEIVED RECEIPT #: OCT 0 4 2019 DOCUMENT#: P2R1252882 CNSTRUCTION PERMIT FOR: OSTDS Existing New ST. Lucie County, Permitting jpee 7i!y( �'7 )� —0018 .PLICANT: (Wallaby's Fabrication) PROPERTY ADDRESS: 3414 Industrial33rd St Fort Pierce, FL 34946 LOT: 5 BLOCK: 3 SUBDIVISION: Airport Industrial Park PROPERTY ID #: 1Q2g_5Q1_QQ29-QQQ_� [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAR ID NUb[BER] i'YSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C_ DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME.• ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND T [ 1,200 ] GALLONS / GPD SeDtic New CAPACITY A [ ] GALLONS / GPD CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ 600 ] GALLONS DOSING TANK CAPACITY [82.06 ]GALLONS @[ 6 ]DOSES PER 24 ERS #Pumps [ 1 ] D [ 613 ] SQUARE FEET Drainfield New SYSTEM R [ ] SQUARE FEET SYSTEM A TYPE SYSTEM: [ ] STANDARD [X] FILLED [] MOUND I ] I CONFIGURATION: [R] TRENCH [ ] BED [ ] N F LOCATION OF BEN001ARK: BM top Of Stubout I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D FILL REQUIRED:- 122.001 INCHES O T H E R [ 5.00 1 [1 INCHES FT 111 ABOVE BELOW] BENCHMARK/REFERENCE POINT [ NCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT 3.00 3 [FI ling Lift Dosing. must be certified as suitable for distributing sewage effluent. BY: MICHAEL W STURR TITLE: Registered Septic Tank Contractor APPROVED BY: — /'w" TITLE: Environmental Supervisor I St. Lucie CeD Dianna 9 May DATE ISSUED: 09/18/2019 EXPIRATION DATE: 03/18/2021 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC C Page �1 f 3 r I NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. Ron DeSantis Mission: Governor To protect, promote & improve the health Scott A. Rivkees MD of all people in Florida through integrated State Surgeon General state, county & community efforts. HEALTH Vision: To be the Healthiest State in the Nation ,r September 18, 2019 MICHAEL STUHR (ASHTON SEPTIC TANKS, INC.) 376 CYCLONE Drive Fort Pierce, FL 34945 RE: Contingency Letter Application Document No: AP1431212 Centrax Permit Number: 56-SF-1986602 OSTDS Number: 3414 Industrial 33rd St Fort Pierce, FL 34946 Lot:5 Block:3 Subdivision: Airport Industrial Park Dear Applicant: This will acknowledge receipt of an application dated 08/29/2019 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. From a review of your completed application, it has been determined that your existing onsite sewage treatment and disposal system has been out of service for more than a year and must be brought into compliance with the standards for new systems before it can be approved for use. In order to proceed with your proposal, you will need to make application for a new system construction permit and bring your system into full compliance with 64E-6, Florida Administrative Code. If you have any questions on this matter, please call our office at (772) 8734931. Sincerely, Dianna May, Environmental Supervisor I Enclosures cc: Florida Department of Health v .FloridaHealth.gov in ST. LUCIE COUNTY TWITTER:HealthyFLA 5150 NW Milner Or, Port Saint Lucie, FL 34983 FACEBOOK:FLDepartmentofHealm PHONE: (772) 8734931 FAX: (772) 8734893 1 YOUTUBE: fidoh St. Lucie County Health Department 5150 NW Milner Dr PortSaint Lucie, FL 34983 HMTH PAYING ON: #•56-SF-1986602 BILL DOC#56-BID-4377444 CONSTRUCTION APPLICATION #: AP1431212 RECEIVED FROM: ASHTON SEPTIC TANKS, INC. (Regist AMOUNT PAID: $ 380.00 PAYMENT FORM: CREDIT CARD 034816 PAYMENT DATE: 08/29/2019 Mill- TO: (Wallaby's Fabrication) FACILITY NAME: PROPERTY LOCATION: 3414 Industrial33rd St Fort Pierce, FL 34946 Lot: 5 Block: 3 Property ID: 1429-501-0029-000-7 EXPLANATION or DESCRIPTION: QUANTITY FEE -1 - Surcharge (All) 1 $ 45.00 124 - OSTDS Construction Repair or Mod Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 131 - OSTDS Construction Application & Existing System E 1 $ 50.00 - 139 - OSTDS Application Approval Existing, No Insp 1 $ 35.00 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 RECEIVED BY: MontanezNM AUDIT CONTROL NO. 56-PID-4083255 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. (D- SF - I°t&A QOA DATE PAID: ac, [cl FEE PAID: 7�"O.00� CC. RECEIPT # R40--0 � [� ] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [f ] Repair [ ] Abandonment [ ] Temporary [ ] 1 "PLICANT: Wallaby's Fabrication AGENT: Ashton Septic Tanks MAILING ADDRESS: 376 Cyclone Dr Ft. Pierce, FL 34950 TELEPHONE: 772-216-9827 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. 1*zk*)04i 40!•lfiiUl�' 0SrN hY to) .I LOT: 5 BLOCK: 3 SUBDIVISION: Airport Industrial PLATTED: 1950 PROPERTY ID #: 1429-501-0029-000-7 ZONING: 4100 I/M OR EQUIVALENT: [ Yes ] PROPERTY SIZE: 1.22 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [,/]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Yes ] DISTANCE TO SEWER: N/A FT PROPERTY ADDRESS: 3414 Industrial 33rd St DIRECTIONS TO PROPERTY: 3414 Industrial 33rd St BUILDING INFORMATION RESIDENTIAL _ [ I COMMERCIAL ._Unit Type of No. of Building Commercial/Institutional System Design No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 1 Metal Fabrication 0 14000 2&employees x 15gal= 390 plus lbay door 100 gal =490 2 490 gal of flow 3 4 [ ] Floor/Equipment Drains [ ] Other (Specify) SIGNATURE: z3 W DATE: r DH 4015, 08 09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC Page I of 4 dFTMe o STATE OF FLORIDA �` ` DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM �, SITE EVALUATION AND SYSTEM SPECIFICATIONS � ,2,ss` PERMIT #•n'-[r]�i�/1i� APPLICANT: Wallaby's Fabrications AGENT: Ashton Septic Tanks L-OT:�5 BLOCK: 3 SUBDIVISION: Sunrise Homesites I PROPERTY ID # : 1429-501-0029-000-7 [ Tax ID Number ] TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. -COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO. NET USABLE AREA AVAILABLE: 1.22 ACRES TOTAL ESTIMATED SEWAGE FLOW: 3050 GALLONS PER DAY[RESIDENCES-TABLE I ] AUTHORIZED SEWAGE. FLOW: 850 GALLONS PER DAY [2500GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: .SWI(')(^.O SQFT UNOBSTRUCTED AREA REQUIRED:__Awgiq SQFT BENCHMARK/REFERENCE POINT LOCATION: 6 m , o e oL� )Qb V r ELEVATION OF PROPOSED SYSTEM SITE IS [INCHES ] ABO THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: N/A FT DITCHES/SWALES: 40 FT NORMALLY WET? [ [ YES [✓] NO WELLS: PUBLIC: N/A FT LIMITED USE: N/A FT PRIVATE: N/A FT NON -POTABLE: N/A FT BUILDING FOUNDATIONS, 10 FT PROPERTY LINES: 15 FT POTABLE WATER LINES: 40 FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES [✓j NO 10 YEAR FLOOD ELEVATION FOR SITE: N/A FT MSL/NGVD SITE ELEVATION: N/A FT MSL/NGVD aviu racvc a.... u�rvauleai.ivav oii'a i MUNSELL #/COLOR TEXTURE DEPTH 10 YR 5/2 SAND 0 TO 15 I0YR4/I SAND 15 To 20 10 YR 5/1 SAND 20 TO 28 10YR3/2 SAND 28 To 44 10 YR 5/3 SAND 44 TO 63 10 YR 5/3 Refusal 63 To 72 TO TO TO -USDA SOIL SERIES: Arents SOIL PROFILE INFORMATION SITE 2 MONSELL #/COLOR TEXTURE DEPTH 10 YR 5/3 SAND 0 TO 16 10YR4/1 SAND 16 TO 23 10 YR 511 SAND 23 TO 29 10 YR 211 SAND 29 TO. 44 10 YR 3/2 SAND 44 TO 65 10 YR 5/3 Refusal 65 To 72 TO TO TO USDA SOIL SERIES: Arents OBSERVED WATER TABLE:63 INCHES [BELOW EXISTING GRADE. TYPE: [PERCHED ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 20 INCHES [.BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: I ] YES [✓) NO MOTTLING: I✓1 YES [ ] NO DEPTH:20 INCHES SOIL TEXTURE/LOADING RATE FOTg SYSTEM SIZING: SAND DEPTH OF EXCAVATION: N/A INCHES DRAINFIELD CONFIGURATION: IV] TRENCH {At BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA: STRIPPING FOUND FROM 10 YR 411 TO 10 YR 511 AT 20" IN THE SOIL MATRIX 1 SITE EVALUATED BY: )DATE: / Dar 4015, 08/09 (Obsolet4 previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 Of 4 c STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION APPLICANT: Wallaby's Fabrications PERMIT # 56"5F-R%(o&O)— CONTRACTOR ASI T'ON SEPTIC TANKS LOT: 5 BLOCK: 3 SUBDIV: Airport Industrial Park ID#: 14295010029007 TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC TANS: CONTRACTOR OR OTHER CERTIFIED PERSON. SIGN AND SEAL ALL SUBMITTED DOCUMENTS. COMPLETE ALL APPLICABLE ITEMS. COMPLETE TANK CERTIFICATION BELOW OR NOTE IN REMARKS WHY THE TANKS CANNOT BE CERTIFIED. EXISTING TANK INFORMATION �)A�o-n �FXlS • hC -T-m- is [1050 ] GALLONS SEPTIC TANK LEGEND: N/A MATERIAL: CONC BAFFLED: I N ] [ ] GALLONS SEPTIC TANK LEGEND: MATERIAL: BAFFLED: IY/N ] [ ] GALLONS GREASE INTERCEPTOR LEGEND: MATERIAL: [ ] GALLONS DOSING TANK LEGEND: MATERIAL: # PUMPS:[ ] pp �� I CERTIFY THAT THE LISTED TANKS WERE PUMPED ON / / BY , HAVE THE VOLUMES SPECIFIED AS DETERMINED BY I DIMENSIONS ], ARE FREE OF OBSERVABLE DEFECTS OR LEAKS, AND HAVE A [ OUTLET FILTER DEVICE ] INSTALLED. 1 ICE=ED BUSINESS offA, i�:l 1'��1� SI� URE OF CCONTRACTOR DAT EXISTING DRAINFIELD INFORMATION [300 ] SQUARE FEET PRIMARY DRAINFIELD SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: 30 X10 [ ] SQUARE FEET SYSTEM NO. OF TRENCHES [ ] DIMENSIONS: X TYPE OF SYSTEM: [✓] STANDARD [ ] FILLED. [ ] MOUND [ j CONFIGURATION: [ ] TRENCH [✓] BED [ ] DESIGN: [✓] HEADER [ ] D-BOX [✓] GRAVITY SYSTEM [ ] DOSED SYSTEM ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE 24 INCHES [BELOW '] SYSTEM FAILURE AND REPAIR INFORMATION EIM/1974 ] SYSTEM INSTALLATION DATE [300 ] GPD ESTIMATED SEWAGE FLOW BASED ON SITE [ ] DRAINAGE STRUCTURES [ CONDITIONS: [ ] SLOPING PROPERTY I NATURE OF [ ] HYDRAULIC OVERLOAD FAI-LURE: [ ] DRAINAGE / RUN OFF POOL r� ?P't TYPE OF WASTE P4 DOMESTIC IV'j COMMERCIAL [ ] METERED WATER [✓] TABLE 1, 64E-6, FAC [ ] PATIO / DECK [ j PARKING [ • ] SOILS [ ✓ ] MAINTENANCE [ ] ROOTS [ ] WATER TABLE [ ] SYSTEM DAMAGE [ ] FAILURE [ ] SEWAGE ON GROUND ,may. TANK [ ] D BOX/HEADER [✓] DRAINFIELD SYMPTOM: [ ] PLUMBING BACKUP L ] •Nr-• •• • r •- �• 1 1� V• iI S'ri G��ls.a SUBMITTED BY: W TITLE/LICENSESQQ o2`Is DATE: DH 4015, 08/1 (Obsole es previous editions which may not be used) Incorporated 4E-6.001, PAC, Page 4 of 4 Lydia Galbraith From: May, Dianna S <Dianna.May@flhealth.gov> Sent: Tuesday, October 08, 2019 9:22 AM To: Lydia Galbraith Cc: William Durden Subject: RE: Wallaby's Fabrication, 3414Industrial 33rd St. Bid. permit 1910-0018 SECURITY WARNING: This email originated from outside the County systems. Please show caution when clicking links or opening attachments unless you recognize the sender and know the content is safe. Questions, call Customer Service at 772-462-2146. Good morning Lydia, I apologize for the delayed response. After reviewing the application, this particular facility is not sized on the square footage of the building- Instead it was sized based on the number of employees and 1 bay door. The permit did include the additional 9,405 sf addition, itjust wasn't indicated on the application page because that's not what the drainfield sizing was based on. I know this is a bit confusing, but he proposed addition is covered in the permit #56-SF-1986602. If you have any questions, just let me know. Thanks, Dianna May Environmental Supervisor Florida Department of Health -St Lucie County Division of Environmental Health 3855 South US 1, Fort Pierce, FL 34982 MAILING: 5150 NW Milner Dr, Port St Lucie, FI34983 Office (772) 873-4896 Cell (772) 370-9330 Mission: To protect, promote & improve the health of all people in Florida through integrated state, county, & community efforts. Vision: To be the Healthiest State in the Nation NOTE: Florida has a very broad public records law. Most written communications to or from state officials regarding state 'business are public records available to the public and media upon request. Your email communication may therefore be subject to public disclosure. How are we doing? Please take our survey! From: Lydia Galbraith <galbraithl@stlucieco.org> Sent: Monday, October 7, 2019 5:06 PM To: May, Dianna S <Dianna.May@flhealth.gov> Cc: William Durden <DurdenW@stlucieco.org> Subject: RE: Wallaby's Fabrication, 3414 Industrial 33rd St. Bid. permit 1910-0018 Good afternoon Dianna, Did you have a chance to look at this situation? Thank you, -Lydia Ga(braith, Zoning Specialist Building and Code Regulation (77,)) 462-1555 galbraithl@stlucieco.org 20?6= EST How From: Lydia Galbraith Sent: Friday, October 04, 2019 11:36 AM To: Dianna.Mav@flhealth.gov Cc: William Durden <DurdenW@stlucieco.org> Subject: Wallaby's Fabrication, 3414 Industrial 33rd St. Bld. permit 1910-0018 Good morning Dianna, Currently we are reviewing the building permit for the metal building addition to above site. The existing building is 14,230 sf, the proposed addition is 9,405 sf. The proposed metal building addition is for a warehouse and has a bathroom in it as well. We have received a copy of the Health Department permit with stamped floor plan and site plan. The septic permit is indicating a 14,000 sf. However, the additional 9,405 seems not to be included. The floor plan stamped for approval only includes the existing building while the site plan does include the proposed building. Please advise if the permit is covering the proposed addition of 9,405 sf, and if not will they need to apply for an additional permit? Thank you, Lydia GaCbraitfi, Zoning Specialist Building and Code Regulation (772)462-1555 ralbraithl@stlucieco.org 20-16_- 2ot[l PEST ° p ates to wot)t, 6T. �UC�C G6UNSY How are we doing? Submit your feedback to Melissa Brubaker, Supervisor, at BrubakermPstlucieco.org Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Ple: se Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal Inspection, examination and t or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers.