HomeMy WebLinkAboutSOIL COMPACT TESTHeadquarters 11345 US. Highway 1 C01 t ENGINEEF Sebastian, FL. 32958 Orlando L%% AND TESUM 723 Progress Way Sanford, FL. 32771 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED: January 22, 2020 KSM JOB # PERMIT #. 1910-0067 CONTRACTOR: Grande Construction JOB LOCATION: 13400 Palmetto Village SCANNED Bldg 3 BY Palm City, Florida St. Lucie County Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone:772-589-0712 C.A.# 5693 KSMengineer ng.net 200298-3d/M H/jo ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. S.E. 0" -12" 50 113.6 113.9 99.7% 2. Center it " 110.3 96.8% 3. N.W. It11 111.6 98.0% Soil Description: Brown Sand with traces of Rock In Place Moisture: 7.9% Optimum Moisture: 11.0% Max. Dry Density: P.C.F. 113.9 @ Test Locations The Density & Penetrometer Readings Indicatethe Degree of Compaction Meets Minimum Required for Staked Foundation Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Email to: greg@grandefl.com Proudly Serving Florida since 1990