HomeMy WebLinkAboutGENERATOR INFORMATIONGENE RAC® INDUSTRIAL
POWER
SD 03 Industrial Diesel Generator Set
S�13Y EPA Certified Stationary Emergency
I
St Lucie County
Standby Power Rating
30 M 38 kVA 60 Hz
Prime Power Rating*
27 M 34 kVA 60 Hz
DSO l
�9001•
2006
l O° o.
o
O -C.v
-
eaw**ee..�.arv,.ara
*EPA Certified Prime ratings are not available in the U.S. or its Territories
Codes and Standards
Generac products are designed to the following standards:
c 91 m UL2200, UL508, UL142, UL498
14-1 NFPA70, 99,110, 37
NFPA
nec * NEC700, 701, 702, 708
IQ IS09001, 8528, 3046, 7637, Pluses #2b, 4
19MAN NEMA ICS10, MG1, 250, ICS6, AB1
ANSJ ANSI C62.41
Ametican National Standards Institute
Image Used for illustration purposes only
Powering Ahead
For over 50 years, Generac has led the industry with
innovative design and superior manufacturing.
Generac ensures superior quality by designing and
manufacturing most of its generator components,
including alternators, enclosures and base tanks,
control systems and communications software.
Generac's gensets utilize a wide variety of options,
configurations and arrangements, allowing us to
meet the standby power needs of practically every
application.
Generac searched globally to ensure the most reliable
engines power our generators. We choose only engines
that have already been proven in heavy-duty industrial
application under adverse conditions.
Generac is committed to ensuring our customers'
service support continues after their generator
purchase.
GENERAC" I INDUSTRIAL
� —��POWER
SD030
Standard Features T'
ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE (if selected)
General
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel flexible exhaust connection
• Critical Exhaust Silencer (enclosed only)
• Factory Filled oil
• Radiator Duct Adapter (open set only)
Fuel System
• Fuel lockoff solenoid
• Primary fuel filter
Cooling System
• Closed Coolant Recovery System
• UV/Ozone resistant hoses
• Factory -Installed Radiator
• Radiator Drain Extension
• 50/50 Ethylene glycol antifreeze
• 120 VAC Coolant Heater
Engine Electrical System
• Battery charging alternator
• Battery cables
• Battery tray
• Solenoid activated starter motor
• Rubber -boated engine electrical connections
CONTROL SYSTEM
• UL2200 GENprolect'"
• 12 leads (3-phase, non 600 V)
• Class H insulation material
• Vented rotor
• 2/3 pitch
• Skewed stator
• Auxiliary voltage regulator power winding
• Amortisseur winding
• BmshlessExcitation
• Sealed Bearings
• Automated manufacturing (winding, insertion,
lacing, varnishing)
• Rotor dynamically spin balanced (get tolerance)
• Full load capacity alternator
• Protective thermal switch
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of circuits- high/low voltage
• Separation of circuits - multiple breakers
• Silencer Heat Shield
• Wrapped Exhaust Piping
• Silencer housed in discharge hood (enclosed only)
• Standard Factory Testing
• 2 Year Limited Warranty (Standby rated Units)
• 1 Year Limited Warranty (Prime rated units)
• Silencer moumedinthe discharge hood (enclosed only)
• Rust -proof fasteners with nylon washers to protect
finish
• High performance sound -absorbing material
• Gasketed doors
• Stamped air-intake louvers
• Air discharge hoods for radiator -upward pointing
• Stainless steel lift off door hinges
• Stainless steel lockable handles
• Rhino Coat'" -Textured polyester powder coat
TANKS (if selected)
• UL142
• Double wall
• Vents
• Sloped top
• Sloped bottom
• Factory pressure tested (2 psi)
• Rupture basin alarm
• Fuellevel
• Check valve in supply and return lines
• Rhino Coat" -Textured polyester powder coat
• Stainless hardware
•
Real/Reactive/Apparent Power
•
15 channel data logging
•
All Phase AC Voltage
•
0.2 msec high speed data logging
,yy
•
All Phase Currents
•
Alarm information automatically comes up on the
�+
•
Oil Pressure
display
•
Coolant Temperature
•
Coolant Level
Alarms
®p�
•
Engine Speed
•
Oil Pressure (Pre -programmable Low Pressure
•
BatteryVoltage
Shutdown)
•
Frequency
•
Coolant Temperature (Pre-programmed High Temp
Control Panel
•
DatefriFault History (Event Log)
Shutdown)me
•
Digital H Control Panel - Dual 4x20 Display
•
Isochronous Governor Control
•
Coolant Level (Pre-programmed Low Level
Shutdown)
•
Programmable Crank Limiter
•
Waterproof/sealed Connectors
•
Low Fuel Pressure Alarm
•
7-Day Programmable Exerciser
•
Audible Alarms and Shutdowns
•
Engine Speed (Pre-programmed Over speed
•
Special Applications Programmable PLC
•
Not in Auto (Flashing Light)
Shutdown)
•
RS-232/485
•
Auto/Off/Manual Switch
•
Battery Voltage Warning
•
All -Phase Sensing DVR
•
E-Slop (Red Mushroom Type)
•
Alarms & warnings time and date stamped
•
Full System Status
•
NFPA110 Level I and II (Programmable)
•
Alarms & warnings for transient and steady slate
•
Utility Monitoring
•
Customizable Alarms, Warnings, and Events
conditions
•
Low Fuel Pressure Indication
•
Modbus protocol
•
Snap shots of key operation parameters during
•
2-Wire Start Compatible
•
Predictive Maintenance algorithm
alarms & warnings
•
Power Output (kW)
•
Sealed Boards
•
Alarms and warnings spelled out (no alarm codes)
•
Power Factor
•
Password parameter adjustment protection
•
kW Hours, Total & Last Run
0
Single point ground
GENERAC' I INDUSTRIAL
® POWER
SD030
Configurable Options• 1
ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE
General O Altemator Upsizing
O Oil Make -Up System O Anti -Condensation Heater
O Oil Heater O Tropical coating
O Industrial Exhaust Silencer O Permanent Magnet Excitation
Fuel System
O Flexible fuel lines
O Primary fuel filter
Engine Electrical System
O 10A UL battery charger
O 2.5A UL battery charger
O Battery Warmer
CONTROL SYSTEM
CIRCUIT BREAKER OPTIONS
O Main Line Circuit Breaker
O 2nd Main Line Circuit Breaker
O Shunt Trip and Auxiliary Contact
O Electronic Trip Breakers
GENERATOR SET
O Gen -Link Communications Software(English
Only)
O 8 Load Position toad Center
O 2 Year Extended Warranty
O 5 Year Warranty
O 5 Year Extended Warranty
O Weather Protected
O Level 1 Sound Attenuation
O Level 2 Sound Attenuation
O Steel Enclosure
O Aluminum Enclosure
O 150 MPH Wind Kit
O 12 VDC Enclosure Lighting Kit
O 120 VAC Enclosure Lighting Kit
O AC/DC Enclosure Lighting Kit
O Door Alarm Switch
TANKS (Size on last page)
O Electrical Fuel Level
O Mechanical Fuel Level
O 54 Gal (204.4 L) Usable Capacity
O 132 Gal (499.7 L) Usable Capacity
O 211 Gal(798.7 L) Usable Capacity
O 300 Gal If 135.6 L) Usable Capacity
O 8"Vent Extension
O 13" Vent Extension
O 19" Vent Extension
O 21-Light Remote Annunciator O Remote E-Stop (Red Mushroom Type, Surface O Remote Communication - Ethernet
O Remote Relay Panel IS or 16) Mount) O t0A Run Relay
O Oil Temperature Sender with Indication Alarm O Remote E-Slop (Red Mushroom Type, Flush O Ground fault indication and protection functions
O Remote E-Stop (Break Glass Type, Surface Mount)
Mount) O Remote Communication - Modem
Engineeredd Op Lions
ENGINE SYSTEM
ALTERNATOR SYSTEM
ENCLOSURE
O Coolant heater ball valves
O 3rd Breaker System
O Motorized Dampers
O Block Heaters
O Door switched for intrusion alert
O Fluid containment pans
GENERATOR SET
O Enclosure ambient healers
TANKS
CONTROL SYSTEM
O Special Testing
O IBC Seismic Certification
O Overfill protection valve
O Spare inputs (x4)/outputs(x4)-H Panel Only
O UL2085 Tank
O Battery Disconnect Switch
O ULC S-601 Tank
O Stainless Steel Tank
O Special Fuel Tanks (MIDEO and FL DEP/DERM, etc.)
O Vent Extensions
Rating Definitions �- - Y _..�_�
Standby —Applicable for a varying emergency load for the duration of a utility power outage with no overload capability.
Prime —Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. The
Prime Power option is only available on International applications.
Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP).
GENERAC' I INDUSTRIAL
® POWER
S0030 application and engineering data
ENGINE SPECIFICATIONS
General
Make
Generac
_ _ _
,EPA Emissions Compliance
Stationary Emergency '
EPA Emissions Reference
See Emissions Data Sheet
Type
In -Line
Displacement - L (cum)
2.4 (146.46)
Bore - mm (in)
90 (3.54)
[Strooke -mm (in)
94 (3.70)
Compression Ratio
21.3:1
Intake Air Method
Turbocharged
Cylinder Head Type
Cast Iron
Piston Type
Aluminum. -
Engine Governing
Governor Electronic Isochronous
Frequency Regulation:(Steady Stale) ± 0.25%
Lubrication System
Oil Pump Type Gear
l0il'filterType Full Flow
Crankcase Capacity - L (qts) 6.2 (6.52)
ALTERNATOR SPECIFICATIONS
Standard Model
390
Poles. ^
4 _
Field Type
Revolving
Lnsulation Class —'Rotor "
H
Insulation Class - Stator
H
TotarHarmonic Distortion
< 5%
Telephone Interference Factor (TIF)
< 50
Standard Excitation
Synchronous
Bearings
Single Sealed Cartridge
Coupling _
Direct, Flexible Disc
Load Capacity - Standby
100%
Prototype Short Circuit Test _
Yes
Cooling System
Cooling System Type
[Water Pump Flow
Fan Type
Fan Speed (rpm) -
Fan Diameter mm (in)
Coolant Heater Wattage
Coolant Heater Standard Voltage
Fuel System
Closed Recovery
Pre-Lubed, Self Sealing
Pusher
2698
560 (22)
1500
120 VAC
Fuel Type
Ultra Low Sulfur Diesel Fuel
Fuel Specifications
ASTM -
Fuel Filtering (microns)
5
Fuel Inject Pump
Distribution Injection Pump
Fuel Pump Type
Engine Driven Gear
Injector Type
Mechanical' .
Fuel Supply Line - mm (in)
7.94 (0.31)
Fuel Return LLine -,mm (in)
7.94 (0.31)
Engine Electrical Syste
System Voltage
Battery Charging Alternator
Battery Size
Battery Voltage '
Ground Polarity
12 VDC
Sid '
See Battery Index 0161970SBY
12VDC "
Negative
Voltage Regulator Type Digital
Number of.Sensed Phases All
Regulation Accuracy (Steady State) ± 0.25%
GENERAC I INDUSTRIAL
----�� POWER
SD030 operating data
POWER RATINGS
Single -Phase 120/240 VAC @1.Opf
Three -Phase 120/208 VAC @0.8pf
Three -Phase 120/240 VAC @0.8pf
Three -Phase 277/480 VACS@0.8pf
Three -Phase 346/600 VAC @0.8pf
STARTING CAPABILITIES (SKVA)
Standby
30 kW Amps: 125
30kW -
Amps:
104,
30 kW
Amps:
90
30 kW
Amps:
46
30 kW
Amps:
36
sKVA vs. Voltage Dip
480 VAC
208/240 VAC
Alternato kW
10%
15%
20%
25%
30%
35%
10%
15%
20%
1 25%
30%
35%
Standard
35
24
36
48
60
72
84
18
27
36
1, 45
54
63,
Upsize 1
40
27
41
54
68
81
95
20
31
41
1- 51
61
71
Upsize2
50
34
52
69
86
103
120
26
39
52
1 65'
77
90
FUEL CONSUMPTION RATES*
COOLING
Fuel Pump Lift - It (m)
3 (1)
Total Fuel Pump Flow (Combustion + Return)
4.5(
Percent Load
gph ([ph)
25%
0.92 (3.5)
50% s
-. 1.45;(55)•• _
75%
1.96 (7.4)
100% :
2.74.(10.4).
Fuel supply installation must accommodate fuel consumption rates at 100% load.
Standby
Coolant Flow, per Minute
_ gpm Opm)
10.(38)'.
Coolant System Capacity
gal (L)
2.8 (10.95)
Heat Rejection to Coolant
BTU/nr
111,000
Inlet Air
cfm (m3/hr)
4,500 (7647)
Max:OperatingRadiator Air Tamp
FO(CO)
122:(50) _
Max. Ambient Temperature (before demte)
F° (CO)
104 (40)
Maximum Radiator Backpressure
in'H O
0.5
COMBUSTION AIR REQUIREMENTS
Standby
Flow at Rated Power cfm (m3/min) 90 (2.55)
ENGINE EXHAUST
Standby
Rated Engine Speed
rpm
1800
Horsepower at Rated
_ hp
49
Piston Speed
f /min (m/min)
1110 (338)
BMEP
psi
d53
" Refer lo'Emissfons Data Sheer for maximum bHP for EPA and SCAM permitting purposes.
Standby
Exhaust Flow (Rated Output)
cfm (0/min)
230 (391)
Max.Backpressure.(PostSilencer)
InHij(r
_ 1.5(5.1)
Exhaust Temp (Rated Output)
OF (eC)
850 (454)
Exhaust Outlet Size (Open Set)
Run (in)
63.5 (2.5) '
Deration — Operational characteristics consider maximum ambient conditions. Demte factors may apply under atypical site conditions. Please consu8 a Generac Power Systems Industrial
Dealer for additional details. All performance ratings in accordance with IS03046, BS5514, 1S08528 and DIN6271 standards.
GENERAC' I INDUSTRIAL
POWER
30030 dimensions and weights*
i
Lk
VV
OPEN SET
BUN TIME
USABLE
HOURS
CAPACITY
Lx W x H in(mm)
Wf Rs(kg) -Tank S Open Set
GAL (L)
NO TANK
-
76 (1930.4) x 38 (914.4) x 46 (1168.4)
2060 (934)
20
54 (204.4)
' 76 (1930.4) x 38 (914.4) x 59 (1498.6)
2540 (1152)
48
132 (499.7)
76 (1930.4) x 38 (914.4) x 71 (1803.4)
2770 (1257)
77
211 (7987) `
I 76 (1930.4) x 38'.(914A) x 83 (2108.2)
_ 9 (1351)
2973042
109
300 (1135.6)
93 (2362.2) x 38 (914.4) x 87 (2209.8)
(1380)
STANDARD ENCLOSURE
RUNTIME
HOURS
USABLE
CAPACITY
GAL (L)
Lx Wx H in(mm)
WT Us(kg)- Enclosure Only
Steel
Aluminum
NO TANK
-
95 (2413) x 38 (965.2) x 50 (1270)
LEVEL 1 ACOUSTIC ENCLOSURE
RUN TIME
HOURS
USABLE
CAPACITY
GAL (L)
L x W x H in (mm)
I
WT Ibs (kg) - Enclosure Only
Steel
Aluminum
NO TANK
-
113 (2870.2) x 38 (965.2) x 50 (1270)
455 (206)
288 (131)
20
54 (204.4)
113 (2870.2) x 38 (9652) x 63 (1600.2)
48
132 (499.7)
113 (2870.2) x 38 (965.2) x 75 (1905)
77
211.(798.7)'.'-113(2870.2)
x 38 (965.2) x87(2209.8)
109
300 (1135.6)
113 (2870.2) x 38 (965.2) x 91 (2311.4)
LEVEL 2ACOUSTIC ENCLOSURE
RUNTIME
HOURS
USABLE
CAPACITY
GAL (L)
Lx W x H in(mm)
WT lbs(kg)- Enclosure Only
Steel
Aluminum
NO TANK
-
95 (2413) x 38 (965.2) x 62 (1574.8)
460 (209)
291 (132)
20
54 (204.4)
._ 95 (2413) x 38 (965.2) x 75 (1905)
48
132 (499.7)
95 (2413) x 38 (965.2) x 87 (2209.8)
77
211 (798.7)
_ 95 (2413) x 38 (965.2) x 99 (2514.6)'
109
300 (1135.6)
1 95 (2413) x 38 (965.2) x 103 (2616.2)
'All measurements are approximate and for estimation purposes only. Sound dBA can be found on the
sound data sheet. Enclosure Only weight is added to Tank 8 Open Set weight to determine total weight.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Indust4al Dealer for debited installation dmwings.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02014 Generac Power Systems, Inc. All rights reserved. All spectticabons are subject to change without notice. Bulletin Ok5085-C / Ponted N U.S.A. 0324114