Loading...
HomeMy WebLinkAboutGENERATOR INFORMATIONGENE RAC® INDUSTRIAL POWER SD 03 Industrial Diesel Generator Set S�13Y EPA Certified Stationary Emergency I St Lucie County Standby Power Rating 30 M 38 kVA 60 Hz Prime Power Rating* 27 M 34 kVA 60 Hz DSO l �9001• 2006 l O° o. o O -C.v - eaw**ee..�.arv,.ara *EPA Certified Prime ratings are not available in the U.S. or its Territories Codes and Standards Generac products are designed to the following standards: c 91 m UL2200, UL508, UL142, UL498 14-1 NFPA70, 99,110, 37 NFPA nec * NEC700, 701, 702, 708 IQ IS09001, 8528, 3046, 7637, Pluses #2b, 4 19MAN NEMA ICS10, MG1, 250, ICS6, AB1 ANSJ ANSI C62.41 Ametican National Standards Institute Image Used for illustration purposes only Powering Ahead For over 50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac's gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. Generac is committed to ensuring our customers' service support continues after their generator purchase. GENERAC" I INDUSTRIAL � —��POWER SD030 Standard Features T' ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE (if selected) General • Oil Drain Extension • Air Cleaner • Fan Guard • Stainless Steel flexible exhaust connection • Critical Exhaust Silencer (enclosed only) • Factory Filled oil • Radiator Duct Adapter (open set only) Fuel System • Fuel lockoff solenoid • Primary fuel filter Cooling System • Closed Coolant Recovery System • UV/Ozone resistant hoses • Factory -Installed Radiator • Radiator Drain Extension • 50/50 Ethylene glycol antifreeze • 120 VAC Coolant Heater Engine Electrical System • Battery charging alternator • Battery cables • Battery tray • Solenoid activated starter motor • Rubber -boated engine electrical connections CONTROL SYSTEM • UL2200 GENprolect'" • 12 leads (3-phase, non 600 V) • Class H insulation material • Vented rotor • 2/3 pitch • Skewed stator • Auxiliary voltage regulator power winding • Amortisseur winding • BmshlessExcitation • Sealed Bearings • Automated manufacturing (winding, insertion, lacing, varnishing) • Rotor dynamically spin balanced (get tolerance) • Full load capacity alternator • Protective thermal switch GENERATOR SET • Internal Genset Vibration Isolation • Separation of circuits- high/low voltage • Separation of circuits - multiple breakers • Silencer Heat Shield • Wrapped Exhaust Piping • Silencer housed in discharge hood (enclosed only) • Standard Factory Testing • 2 Year Limited Warranty (Standby rated Units) • 1 Year Limited Warranty (Prime rated units) • Silencer moumedinthe discharge hood (enclosed only) • Rust -proof fasteners with nylon washers to protect finish • High performance sound -absorbing material • Gasketed doors • Stamped air-intake louvers • Air discharge hoods for radiator -upward pointing • Stainless steel lift off door hinges • Stainless steel lockable handles • Rhino Coat'" -Textured polyester powder coat TANKS (if selected) • UL142 • Double wall • Vents • Sloped top • Sloped bottom • Factory pressure tested (2 psi) • Rupture basin alarm • Fuellevel • Check valve in supply and return lines • Rhino Coat" -Textured polyester powder coat • Stainless hardware • Real/Reactive/Apparent Power • 15 channel data logging • All Phase AC Voltage • 0.2 msec high speed data logging ,yy • All Phase Currents • Alarm information automatically comes up on the �+ • Oil Pressure display • Coolant Temperature • Coolant Level Alarms ®p� • Engine Speed • Oil Pressure (Pre -programmable Low Pressure • BatteryVoltage Shutdown) • Frequency • Coolant Temperature (Pre-programmed High Temp Control Panel • DatefriFault History (Event Log) Shutdown)me • Digital H Control Panel - Dual 4x20 Display • Isochronous Governor Control • Coolant Level (Pre-programmed Low Level Shutdown) • Programmable Crank Limiter • Waterproof/sealed Connectors • Low Fuel Pressure Alarm • 7-Day Programmable Exerciser • Audible Alarms and Shutdowns • Engine Speed (Pre-programmed Over speed • Special Applications Programmable PLC • Not in Auto (Flashing Light) Shutdown) • RS-232/485 • Auto/Off/Manual Switch • Battery Voltage Warning • All -Phase Sensing DVR • E-Slop (Red Mushroom Type) • Alarms & warnings time and date stamped • Full System Status • NFPA110 Level I and II (Programmable) • Alarms & warnings for transient and steady slate • Utility Monitoring • Customizable Alarms, Warnings, and Events conditions • Low Fuel Pressure Indication • Modbus protocol • Snap shots of key operation parameters during • 2-Wire Start Compatible • Predictive Maintenance algorithm alarms & warnings • Power Output (kW) • Sealed Boards • Alarms and warnings spelled out (no alarm codes) • Power Factor • Password parameter adjustment protection • kW Hours, Total & Last Run 0 Single point ground GENERAC' I INDUSTRIAL ® POWER SD030 Configurable Options• 1 ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE General O Altemator Upsizing O Oil Make -Up System O Anti -Condensation Heater O Oil Heater O Tropical coating O Industrial Exhaust Silencer O Permanent Magnet Excitation Fuel System O Flexible fuel lines O Primary fuel filter Engine Electrical System O 10A UL battery charger O 2.5A UL battery charger O Battery Warmer CONTROL SYSTEM CIRCUIT BREAKER OPTIONS O Main Line Circuit Breaker O 2nd Main Line Circuit Breaker O Shunt Trip and Auxiliary Contact O Electronic Trip Breakers GENERATOR SET O Gen -Link Communications Software(English Only) O 8 Load Position toad Center O 2 Year Extended Warranty O 5 Year Warranty O 5 Year Extended Warranty O Weather Protected O Level 1 Sound Attenuation O Level 2 Sound Attenuation O Steel Enclosure O Aluminum Enclosure O 150 MPH Wind Kit O 12 VDC Enclosure Lighting Kit O 120 VAC Enclosure Lighting Kit O AC/DC Enclosure Lighting Kit O Door Alarm Switch TANKS (Size on last page) O Electrical Fuel Level O Mechanical Fuel Level O 54 Gal (204.4 L) Usable Capacity O 132 Gal (499.7 L) Usable Capacity O 211 Gal(798.7 L) Usable Capacity O 300 Gal If 135.6 L) Usable Capacity O 8"Vent Extension O 13" Vent Extension O 19" Vent Extension O 21-Light Remote Annunciator O Remote E-Stop (Red Mushroom Type, Surface O Remote Communication - Ethernet O Remote Relay Panel IS or 16) Mount) O t0A Run Relay O Oil Temperature Sender with Indication Alarm O Remote E-Slop (Red Mushroom Type, Flush O Ground fault indication and protection functions O Remote E-Stop (Break Glass Type, Surface Mount) Mount) O Remote Communication - Modem Engineeredd Op Lions ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE O Coolant heater ball valves O 3rd Breaker System O Motorized Dampers O Block Heaters O Door switched for intrusion alert O Fluid containment pans GENERATOR SET O Enclosure ambient healers TANKS CONTROL SYSTEM O Special Testing O IBC Seismic Certification O Overfill protection valve O Spare inputs (x4)/outputs(x4)-H Panel Only O UL2085 Tank O Battery Disconnect Switch O ULC S-601 Tank O Stainless Steel Tank O Special Fuel Tanks (MIDEO and FL DEP/DERM, etc.) O Vent Extensions Rating Definitions �- - Y _..�_� Standby —Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. Prime —Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications. Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP). GENERAC' I INDUSTRIAL ® POWER S0030 application and engineering data ENGINE SPECIFICATIONS General Make Generac _ _ _ ,EPA Emissions Compliance Stationary Emergency ' EPA Emissions Reference See Emissions Data Sheet Type In -Line Displacement - L (cum) 2.4 (146.46) Bore - mm (in) 90 (3.54) [Strooke -mm (in) 94 (3.70) Compression Ratio 21.3:1 Intake Air Method Turbocharged Cylinder Head Type Cast Iron Piston Type Aluminum. - Engine Governing Governor Electronic Isochronous Frequency Regulation:(Steady Stale) ± 0.25% Lubrication System Oil Pump Type Gear l0il'filterType Full Flow Crankcase Capacity - L (qts) 6.2 (6.52) ALTERNATOR SPECIFICATIONS Standard Model 390 Poles. ^ 4 _ Field Type Revolving Lnsulation Class —'Rotor " H Insulation Class - Stator H TotarHarmonic Distortion < 5% Telephone Interference Factor (TIF) < 50 Standard Excitation Synchronous Bearings Single Sealed Cartridge Coupling _ Direct, Flexible Disc Load Capacity - Standby 100% Prototype Short Circuit Test _ Yes Cooling System Cooling System Type [Water Pump Flow Fan Type Fan Speed (rpm) - Fan Diameter mm (in) Coolant Heater Wattage Coolant Heater Standard Voltage Fuel System Closed Recovery Pre-Lubed, Self Sealing Pusher 2698 560 (22) 1500 120 VAC Fuel Type Ultra Low Sulfur Diesel Fuel Fuel Specifications ASTM - Fuel Filtering (microns) 5 Fuel Inject Pump Distribution Injection Pump Fuel Pump Type Engine Driven Gear Injector Type Mechanical' . Fuel Supply Line - mm (in) 7.94 (0.31) Fuel Return LLine -,mm (in) 7.94 (0.31) Engine Electrical Syste System Voltage Battery Charging Alternator Battery Size Battery Voltage ' Ground Polarity 12 VDC Sid ' See Battery Index 0161970SBY 12VDC " Negative Voltage Regulator Type Digital Number of.Sensed Phases All Regulation Accuracy (Steady State) ± 0.25% GENERAC I INDUSTRIAL ----�� POWER SD030 operating data POWER RATINGS Single -Phase 120/240 VAC @1.Opf Three -Phase 120/208 VAC @0.8pf Three -Phase 120/240 VAC @0.8pf Three -Phase 277/480 VACS@0.8pf Three -Phase 346/600 VAC @0.8pf STARTING CAPABILITIES (SKVA) Standby 30 kW Amps: 125 30kW - Amps: 104, 30 kW Amps: 90 30 kW Amps: 46 30 kW Amps: 36 sKVA vs. Voltage Dip 480 VAC 208/240 VAC Alternato kW 10% 15% 20% 25% 30% 35% 10% 15% 20% 1 25% 30% 35% Standard 35 24 36 48 60 72 84 18 27 36 1, 45 54 63, Upsize 1 40 27 41 54 68 81 95 20 31 41 1- 51 61 71 Upsize2 50 34 52 69 86 103 120 26 39 52 1 65' 77 90 FUEL CONSUMPTION RATES* COOLING Fuel Pump Lift - It (m) 3 (1) Total Fuel Pump Flow (Combustion + Return) 4.5( Percent Load gph ([ph) 25% 0.92 (3.5) 50% s -. 1.45;(55)•• _ 75% 1.96 (7.4) 100% : 2.74.(10.4). Fuel supply installation must accommodate fuel consumption rates at 100% load. Standby Coolant Flow, per Minute _ gpm Opm) 10.(38)'. Coolant System Capacity gal (L) 2.8 (10.95) Heat Rejection to Coolant BTU/nr 111,000 Inlet Air cfm (m3/hr) 4,500 (7647) Max:OperatingRadiator Air Tamp FO(CO) 122:(50) _ Max. Ambient Temperature (before demte) F° (CO) 104 (40) Maximum Radiator Backpressure in'H O 0.5 COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power cfm (m3/min) 90 (2.55) ENGINE EXHAUST Standby Rated Engine Speed rpm 1800 Horsepower at Rated _ hp 49 Piston Speed f /min (m/min) 1110 (338) BMEP psi d53 " Refer lo'Emissfons Data Sheer for maximum bHP for EPA and SCAM permitting purposes. Standby Exhaust Flow (Rated Output) cfm (0/min) 230 (391) Max.Backpressure.(PostSilencer) InHij(r _ 1.5(5.1) Exhaust Temp (Rated Output) OF (eC) 850 (454) Exhaust Outlet Size (Open Set) Run (in) 63.5 (2.5) ' Deration — Operational characteristics consider maximum ambient conditions. Demte factors may apply under atypical site conditions. Please consu8 a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with IS03046, BS5514, 1S08528 and DIN6271 standards. GENERAC' I INDUSTRIAL POWER 30030 dimensions and weights* i Lk VV OPEN SET BUN TIME USABLE HOURS CAPACITY Lx W x H in(mm) Wf Rs(kg) -Tank S Open Set GAL (L) NO TANK - 76 (1930.4) x 38 (914.4) x 46 (1168.4) 2060 (934) 20 54 (204.4) ' 76 (1930.4) x 38 (914.4) x 59 (1498.6) 2540 (1152) 48 132 (499.7) 76 (1930.4) x 38 (914.4) x 71 (1803.4) 2770 (1257) 77 211 (7987) ` I 76 (1930.4) x 38'.(914A) x 83 (2108.2) _ 9 (1351) 2973042 109 300 (1135.6) 93 (2362.2) x 38 (914.4) x 87 (2209.8) (1380) STANDARD ENCLOSURE RUNTIME HOURS USABLE CAPACITY GAL (L) Lx Wx H in(mm) WT Us(kg)- Enclosure Only Steel Aluminum NO TANK - 95 (2413) x 38 (965.2) x 50 (1270) LEVEL 1 ACOUSTIC ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL (L) L x W x H in (mm) I WT Ibs (kg) - Enclosure Only Steel Aluminum NO TANK - 113 (2870.2) x 38 (965.2) x 50 (1270) 455 (206) 288 (131) 20 54 (204.4) 113 (2870.2) x 38 (9652) x 63 (1600.2) 48 132 (499.7) 113 (2870.2) x 38 (965.2) x 75 (1905) 77 211.(798.7)'.'-113(2870.2) x 38 (965.2) x87(2209.8) 109 300 (1135.6) 113 (2870.2) x 38 (965.2) x 91 (2311.4) LEVEL 2ACOUSTIC ENCLOSURE RUNTIME HOURS USABLE CAPACITY GAL (L) Lx W x H in(mm) WT lbs(kg)- Enclosure Only Steel Aluminum NO TANK - 95 (2413) x 38 (965.2) x 62 (1574.8) 460 (209) 291 (132) 20 54 (204.4) ._ 95 (2413) x 38 (965.2) x 75 (1905) 48 132 (499.7) 95 (2413) x 38 (965.2) x 87 (2209.8) 77 211 (798.7) _ 95 (2413) x 38 (965.2) x 99 (2514.6)' 109 300 (1135.6) 1 95 (2413) x 38 (965.2) x 103 (2616.2) 'All measurements are approximate and for estimation purposes only. Sound dBA can be found on the sound data sheet. Enclosure Only weight is added to Tank 8 Open Set weight to determine total weight. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Indust4al Dealer for debited installation dmwings. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02014 Generac Power Systems, Inc. All rights reserved. All spectticabons are subject to change without notice. Bulletin Ok5085-C / Ponted N U.S.A. 0324114