Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Sf Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: LIBERTY TIRE RECYCLING Project Address: 9675 RANGE LINE ROAD, PORT ST. LUCIE, FLORIDA 34987 Permit #: Type: Construction BH-4­sc by FOUNDATION DESIGN INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) % 1. DESIGN CODE: Florida BUILDING Code 2010 Edition with 20 17 Supplements using ASCE 7-}dl 6 2. Structure Designed as (check one): _Enclosed _Partially Enclosed _Open 3. Risk Category: X 11 _II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 145 mph _ASD x LRFD End Zone Width: ft S. Mean Roof Height ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design \�\\\ gyp SEngG AHMADREZA SEDAGHAT Q�EN SF h,'4A Print Name Cent # & Co. Cent Auth. %v -t % 74A61 is No• Signa e, anil FLORIDA ENGINEERING AND DESIGN INC. PLO .. , Company Name &Address ,N[�`� SEP 2 5 2019 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 % o co Certification for Design Load Compliance ��L Project Name: LIBERTY TIRE RECYCLING Project Address: 9675 RANGE LINE ROAD, PORT ST. LUCIE, FLORIDA 34987 Permit #: Occupancy Type: Construction Type: FOUNDATION DESIGN ioi 9��•a5� INSTRUCTIONS FOR USE: by Dw ►J.%� • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring'a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) ID 1. DESIGN CODE: Florida BUILDING Code 2010 Edition with 20 17 Supplements using ASCE 7/, 2. StructureDesignedas (check one): _Enclosed _Partially Enclosed _Open 3. Risk Category: X I 11 _III IV Exposure Category: B X C _D 4. Design Wind Velocity 145 mph _ASD X LRFD End Zone Width: ft 5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings) Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: IC) �� `s. ® Fo® I certify that, to the best of my knowledge and belief, the attached plans & specificati n e �p Igne to Irl comply applicable structural portions of the building codes currently ad d%DI�rijl�ui %0P. s ANCE �'iih �fi� C ,.� GIs at structural elements depicted on these plans provide adeSIP.r sUMEtWUNTY AHMADREZA SEDAGHAT 1 OCC Q;, A i No. 74461 Prin Name Cert # & Co. Cert Auth. STATE OF itu;�{�CA?]de\FLORIDA ENGINEERING AND DESIGN INC. Company Name & Address Revi e/d6mom��� SEP 25 2019