HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Sf
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: LIBERTY TIRE RECYCLING
Project Address: 9675 RANGE LINE ROAD, PORT ST. LUCIE, FLORIDA 34987
Permit #:
Type: Construction
BH-4sc by
FOUNDATION DESIGN
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) %
1. DESIGN CODE: Florida BUILDING Code 2010 Edition with 20 17 Supplements using ASCE 7-}dl 6
2. Structure Designed as (check one): _Enclosed _Partially Enclosed _Open
3. Risk Category: X 11 _II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 145 mph _ASD x LRFD End Zone Width: ft
S. Mean Roof Height ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
\�\\\ gyp SEngG AHMADREZA SEDAGHAT
Q�EN SF h,'4A Print Name Cent # & Co. Cent Auth.
%v
-t % 74A61 is
No•
Signa e, anil FLORIDA ENGINEERING AND DESIGN INC.
PLO .. , Company Name &Address
,N[�`� SEP 2 5 2019
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 % o
co
Certification for Design Load Compliance ��L
Project Name: LIBERTY TIRE RECYCLING
Project Address: 9675 RANGE LINE ROAD, PORT ST. LUCIE, FLORIDA 34987
Permit #: Occupancy Type: Construction Type: FOUNDATION DESIGN ioi 9��•a5�
INSTRUCTIONS FOR USE: by Dw ►J.%�
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring'a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) ID
1. DESIGN CODE: Florida BUILDING Code 2010 Edition with 20 17 Supplements using ASCE 7/,
2. StructureDesignedas (check one): _Enclosed _Partially Enclosed _Open
3. Risk Category: X I 11 _III IV Exposure Category: B X C _D
4. Design Wind Velocity 145 mph _ASD X LRFD End Zone Width: ft
5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings)
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? NO Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: IC) �� `s. ® Fo®
I certify that, to the best of my knowledge and belief, the attached plans & specificati n e �p Igne to Irl
comply applicable structural portions of the building codes currently ad d%DI�rijl�ui %0P. s ANCE
�'iih �fi�
C ,.� GIs at structural elements depicted on these plans provide adeSIP.r sUMEtWUNTY
AHMADREZA SEDAGHAT 1 OCC
Q;, A i
No. 74461 Prin Name Cert # & Co. Cert Auth.
STATE OF
itu;�{�CA?]de\FLORIDA ENGINEERING AND DESIGN INC.
Company Name & Address
Revi e/d6mom��� SEP 25 2019