PRODUCT DATA SUBMITTALS
109-B Concord Drive ®1 D Y N A F I R E �sselberry, 65 32707 E T Alarm s 407.830.6500 D Y N A�E • I Germ Monitoring A DynaFire.com t' SCANNED BY St. Lucie County PRODUCT DATA SUBMITTALS FIRE ALARM SYSTEM DATE: August 16, 2019 PROJECT: SEC Prima Vista CUSTOMER: Southeast Centers Jordan Dailey PREPARED BY: Ryan Buckley RECEIyED OCT y 6 2019 Pe St. L� le CAP qr ent Casselberry I Largo -I Jacksonville I Pompano I Melboume EF20000529 I FL PE26483 I NICET IV 99907 1 FP16491600012009 I FPC15-000057 SEC Prima Vista Fire Alarm System Submittal ITEM PART # MANUF. DESCRIPTION Panel Equipment 1 NFW-100X Notifier Addressable Fire Alarm Control Panel w/ Display w/ back up batteries 2 FCPS-24S8 Notifier Power Supply 3 FDU-80 Notifier Annunciator 4 7788 F-ULP AES Wireless Fire Alarm Communicator Addressable Devices 1 NP-200 Notifier Photoelectric Smoke Detector 2 NMM-100 Notifier Monitor Module 3 NMM-100P Notifier Mini Monitor Module 4 NDM-100 Notifier Dual Monitor Module 5 NC-1 o0R Notifier Relay Module 6 NOT-BG12LX Notifier Manual Pullstation 7 DNR Notifier Duct Detector Housing DST-5 Notifier Sampling Tube RTS-151 Notifier Remote Test Station Notification Appliance Devices 1 P2RL System Sensor Wire 1 SLC Windy City Wire 2 Remote Ann. Windy City Wire 3 Initiating Windy City Wire 4 Notification (strobes) Windy City Wire Surge Suppression Devices 1 E120V-GT Space Age 2 DTK-2-LVLPF Ditek Batteries & Calculations 1 Batteries Notifier Horn/Strobe Wall Mount 16 AWG, 1 pair jacketed, FPLP 16 AWG, 2 pair jacketed, FPLP 18 AWG, 1 pair jacketed, FPLP 14AWG, 1 pair jacketed, FPLP 120 VAC Surge Suppression 24 VDC Surge Suppression See Shop Drawings SEC Prima Vista 8/16/2019 Fire Alarm System Panel Equipment NOT IFIER® by Honeywell NFW-100X Intelligent Addressable FACP with Communicator General The FireWarden400X (NFW-100)Q is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-1 DD (NFW-100). The NFW-100X comes with a pre -installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The preinstalled IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IF communicator's Internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the ]POTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a meta] cabinet. Available accessories include local and remote uploadidownload software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features • Listed to UL Standard 864, 10th edition • Pre -installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator overAlarnNet • Optional CELL -MOD or CELL-CAB-N GSM Central Station Com- municator over AlarnNetRi • Automated activation of the NFC-50/100 Emergency Command Center • NFC-FFT Firefighter Telephone option • Compatiblewith SWIFTO wireless devices • Auto -programming (learn made) reduces installation time. Reports two devices set to the same address • Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendarwith automatic daylight savings control • History file with 1,OOD event capacity • Addressable sounder base compatibility • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Water0ow selection per module point • Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One -person audible or silent walk test with walk -test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP • Supports FlashScan® and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 198 addressable device capacity (99 addressable detectors and 99 modules) • Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ua4 NOTIFICATION APPLIANCE CIRCUITS (NACS) • Four independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACS with two -stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACS NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is Z7 A DN-60959:C • 7116/2018 — Page 1 of 4 PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 99 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows6based software package, and upload/download system programming locally. Ofiline program- ming requires an ethernet connection. FS-Tools is available on www.notfier.com. User interface LED INDICATORS • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha -numeric pad • Acknowledge Alarm Silence • Drill (Manual Evacuate) our (4) programmable function keys • Reset (lamp test) PRODUCT LINE INFORMATION NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, eta FS-Tools: Programming software for Windows® -based PC com- puter. Available for download at wwwnotifier.com. CELL-CAB-N/CELL•MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES•R: Optional dress panel for the NFW-100X (red). DP-ES-B: Optional dress panel for NFW-100X (black). TR-CE-B: Optional trim ring for semi -flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. BS-25: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi -modules in a BB-25 cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG420: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANNA 00R: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-110: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial(Parallel Printer Gateway module provides a connecton for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low -profile photoelectric smoke detector. FlashScan only. FSP•951-IV: Addressable low -profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low -profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-2004V: Addressable low -profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low -profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-20OT: Addressable low -profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-20OR-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. PST-951: Low -profile 136'F fixed thermal sensor. FlashScan only. FST-9514V: Low -profile 135"F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low -profile 135"F fixed thermal sensor. B300-6 base included, FlashScan only. NH-2004V: Low -profile 135'F fixed thermal sensor. Ivory. B300-64V base included, FlashScan and CLIP mode. FST-951R: Low -profile, intelligent, rate -of -rise thermal sensor. FlashScan only. FST-951R-IV: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. FlashScan and CLIP mode. Page 2 of 4 — DN-60959:C • 7/16/2018 NH-200R: Law -profile 135"F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R4V: Low -profile 135"F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low -profile intelligent 190"F/88°C fixed thermal sensor. Flash Scan only. FST-951H4V: Low -profile intelligent 190°F/88"C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low -profile intelligent 190"F/88"C fixed thermal sensor. B300-6 base included, FlashScan only. NH-200H4V: Low -profile intelligent 190"F/88°C fixed thermal sen- sor. Ivory. B300-64V base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low -profile ionization smoke detector. NI-100: Addressable low -profile ionization smoke detector. FSP-851: Addressable low -profile photoelectric smoke detector. NP-100: Addressable low -profile photoelectric smoke detector. FSP-851T: Addressable low -profile photoelectric smoke detector with thermal sensor. NP-100T: Addressable low -profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast -response, low -profile heat detector. NH-100: Fast -response, low -profile heat detector. FST-551 R: Fast -response, low -profile heat detector with rate -of -rise option. NH-100R: Fast -response, low -profile heat detector with rate -of -rise option. FST-851 H: Fast{esponse, low -profile heat detector that activates at 190"F/88"C. NH-100H: Fast -response, low -profile heat detector that activates at 190"F/88"C. FAPT-851: Addressable low -profile mufti -sensor detector. NP-Al00: Addressable low -profile multi -sensor detector. B200S: Programmable, addressable sounder base. B20DSR: Addressable sounder base. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order FSP-851 R, FSP-951 R, or NP-100R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-100R separately.) Addressable Modules FMM-1: Addressable Monitor Module for one zone of normally -open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of4ine resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM4: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-1: Addressable Control Module for one Style Y2 (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style Y2 (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly, to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. N100-ISO: Fault Isolator Module. ISO-6: Six -fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- loOP. NMM-100-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six -zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200ROR135: LlteSpeed intelligent wireless rate of rise (135") heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIX135: intelligent wireless fixed -temperature (135") heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-12LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the RmWarden-100X, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N1004SO (DN-6994), NP-100 series (DN-6995), NH-100MH-100R (DN- 6997), DNR/InnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-f00P/NDM-f00/NZM-100 (DN-6999), NC-100 (DN- 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-11 FZM-1/FMM-101 (DN-6720), FCM-11FRM-1 (DN-6724), NOT-BG12LX (DN-7001), NBG-12LX (DN-6726), and FireWarden SLC Manual (52304). DNE0959:C - 7116/2018 —Page 3 of 4 SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits................................................1 • Addressable device capacity ..................................................198 • Programmable software zones.. ............................................... 99 • Annunciators............................................................................. 16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50160 Hz, 3.25 A. auto -sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 25omA regulated. End -of -Line Resistor: 4.7k ohm, %a watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 k12 - 22 k4 ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non -power -limited, non -supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CEIB): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49"C/32 —120"F and at a relative humidity 93% t 2% RH (noncondensing) at 326C t 2"C (90"F t 3"F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27"C/60 — 80"F. Addressable Device Accessories End -of -Line Resistor Assembly (R-47K and R3.9K): The 47kohm assembly supervises the NMM-100-10, NDM-100, NMM- 10013, and NC-100 module circuits. The 3.9k ohm assembly super- vises the NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). —AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). —REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). —CENTRAL STATION (Automatic, Manual and Waterflow. and Sprinkler Supervised). —OT, PSDN (Other Technologies, Packet -switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 CSFM: 7165-0028:0505 FDNY: COA#6268 I® rd®%sumosim pSSllTr SYSTEMS 1Fs dommmt a ndt vtleMad to be use0 for valaSatlon ryryoses. We ay to keep our piodtat Wwmalm LINO maM amaate We mood a0 speck aWlaoors m animpam m mquuememe. AS speorxaems are subject M durye a,dam mtim. Anft*,, Ne11nER9, RmWa dew, SWIFTW, and System SeiaaO NOTIFIER me tmdemarka Of Homyadi InN OW me K.S000aM 12 Clintonville Road Wyda s&ammgrseedtade a,kadmekmm°aca'p� �J NOTIFIER ® Northford, CT 06472 UOIS by Hormpe0 Ideamfi al ma MI � awned. UmutladrM 203A84.7161 memedmxrn tisssbrypmni . m by Honeywell m=v.notifier.com counbyorodgm:USA FCPS-24S6(C/E) & FCPS- 24SS(C/E) 6- & 8-Amp 24-Volt General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 2458 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24136C & FCPS-24SBC are ULOlisted. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used In this document refers to the standard FCPS- 2456 and FCPS-24S8, FCPS-24S6C and FCPS-24SBC, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commanders' appliances. • Operates as a "sync -follower' or as a "sync -generator" (default). See note on page 2. • Contains two fully -isolated inpuVcontrol circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently"ON" (stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. • Optional power -supervision relay (EOLR-1). • In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. • Fully regulated and filtered power output - optimal for pow- ering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated/<Hered power. • Power -limiting technology meets UL power -limiting require- ments. • Form-C normally -closed trouble relay. • Fully supervised power supply, battery, and NACs. • Selectable earth fault detection. • AC trouble report selectable for immediate 2-hour delay. • Works with virtually any UL 864 fire alarm control which uti- lizes an industry -standard reverse -polarity notification cir- cuit (including unfiltered and unregulated NAC power). • Requires input triaaer voltaae of 9 - 32 VDC. • Self-contained in compact, lock!i x 2.75"D (cm: 38.1 H x 36.83W x DN-692T.A2 (�J NOT 1 F 1 E R° by Honeywell • Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- les. • Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. • Fixed, clamp -type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. Specifications Primary (AC) Power: • FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. • FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. • Wire Size: minimum #14 AWG (2.Omm2) with 600 V insula- tion. Control Input Circuit: • Trigger Input Voltage: 9 to 32 VDC. • Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. • 3.0 A maximum for anyone circuit. • Total continuous current for all outputs (stand-alone mode): — FCPS-24S6: 4.0 A maximum. — FCPS-24S8: 6.0 A maximum. Total short-term current for all outputs (NAC expander mode): — FCPS-24S6: 6.0 A maximum. — FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead -acid batteries only. DN-5927:A2. 5117113 — Page 1 of 2 • Float -charge voltage: 27.6 VDC. • Maximum current charge: 1.5 A. • Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style `/) outputs or tour Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse -polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances' away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE. Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the and of a NAC wire run, the FCPS-24S6/-24S8 can track (i.e. "follow') the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower, the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 are configured (via DIP switch settings) as a "sync generator, the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-24SB comply with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635, S674 • ULC Listed: S635 (FCPS-24S60 & FCPS-24SBC) • CSFM Approved: 7315-0028:225 • MEA: 299-02-E • FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24SB: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24SBC Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24SB with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style 1) NAC option module. EOLR-1: 12/24 VDC end -of -line relay for monitoring four -wire BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIERO are registered trademarks of Honeywell International Inc. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I® This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 9I6311IM B MASAFALfABMA All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.nodfieccom Page 2 of 2— DN-6927:A2.5117/13 NOTIFIER 0 FIRE S7rSTEMS GENERAL The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER AFP300, AFP-400, and AFC-600 Fire Alarm Control Panels. The FDU- 80 mimics the display of the control panel and displays com- plete system point status information. Up to 32 FDU-80's may be connected onto the EIA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. NOTES: 1) The FDU-80 is compatible with the NOTIFIER AFP-3001 400 Rev. 3.62 or higher, and AFC-600 (all revisions). 2) The FDU-80 can be used on the same data loop as the LCD-80ILCD-BOTM annunciators revision 1.6 software or higher. FEATURES • 80character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. • System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. • No programming necessary — FDU-80 connects to the terminal mode port. • Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. • Time and date display field. • Aesthetically pleasing design. • May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). • Up to 32 FDU-80 annunciators per FACP. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. • Local piezo sounder with alarm and trouble resound. • Semi -flush -mounts to2-3/16"/55.56mm(minimum)deep, three -gang electrical box (NOTIFIER PIN 10103) or three- gangable electrical switchbox. • Surface -mounts to NOTIFIER SBB-3 surface backbox. OPERATION The FDU-80 annunciator provides the FACP with point an- nunciation with full display text on an 80-character LCD dis- play. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All geld -wiring terminations on the January 2, 2001 FDU-80 80-Character Liquid Crystal Display Fire Annunciator DN-6820 • D-123 Section: Annunciators California State Fire U I I A�ys�yf Marshal I. L 7120-0028:209 LISTED CS100 S635 FDU-80 Annunciator I <— FDU-80 use removable, compression -type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communi- cations (two in and two return); and two for the 24 VDC regu- lated power. Dip switches control local functions such as: piezo disable, control switches/key-switch disable, transmit/ receive mode. INSTALLATION The FDU-80 can be semi -flush mounted to a 2-3/16"/55.56 mm (minimum) deep, three -gang electrical box (NOTIFIER P/N 10103) or three-gangable electrical switchboxes. Alter- nately, an SBB-3 surface backbox is available for surface - mount applications. This document is not intended to bea used for installation purposes. We try keep our IYO 9001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 § N OTI RI E W 12 Clintonville Road, Northford, Connecticut 06472 8ueuu�IN6 &MANA81C111M Made in the U.SA. ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key -switch lock. 10103 Three -gang electrical box, minimum 2-3/16" (55.56 mm) deep, for semi -flush -mount applications. SBB3 Three -gang surface backbox for surface -mount applications. FDU-80 TERMINAL MODE WIRING EXAMPLE a. •:°: •�: •a:•: — - Phsc:arn Up to 6,000 ft. (1828.8 m) between EACH DEVICEin the EIA-485 loop Terminal Mode FDU-80 \ FDU-80 EIA-485 1t (2-wires) r ; A�.�•.�S 24vDC 0090 ® B'ODO AFP-400 Up to 6,000 ft. (1828.8 m) back from last device to end of EIA-485 loop FDU-80 Terminal Mode EIA-485 return (2-wires) Notes: 1) EIA-485: Maximum of 5,000 feet (1828.8 m) cable length from FACP to FDU-80 annunciators and back to FACP (6,000 feet [1828.8 m) total). Circuit is power -limited. 2) Up to 32 FDU-80 annunciators may be used on the EIA-485 circuit. When multiple FDU-80's are used, certain panels will require additional power supplies (refer to panel documentation). 3) Between each FDU-80 annunciator are four wires: a twisted -shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. 4) On the AFP-300/400, software revision 3.62 or higher is required. MOUNTING TO BACKBOX(ES) The FDU-80 annunciators can be Mounting semi -flush -mounted in a three -gang electrical box Holes (4) with a minimum depth of 2-3116" (55.56 mm) (NOTIFIER PM 10103). The FDU-80 annunciators can be mounted in three gangable electrical switch boxes connected together. NOTE., Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backbox for surface -mount applications. 5-13116" (147.6375 mm) wide x 4- (101.6 mm) high x minimum 2-3116" (55.5625 mm) deep, three -gang electrical box (NOTIFIER P/N 10103, shown at right). FDU-80 flange 0 0 FIRE ALAFA ANNUNCtATOR • ' Page 2 of 2 — DN-6820 •01/02/01 Features — All models • LIL Listed commercial fire alarm applications. • Meets NFPA 72 requirements • Direct reporting to DynaNet receiver across DynaNet wireless mesh network • Each Subscriber acts as transmit-ter/receiver/ repeater • Simple and fast activation on network • On board status LEDs for easy set up • 8 programmable zone inputs — 7788 F • 4 programmable zone inputs and 4 reverse polarity inputs • Easy programming via DynaNet handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application Model 7788 F-ULP with IntelliPro Fire also includes • IntelliPro Fire transmits full alarm data from virtually any fire alarm panel digital communicator • Alarm format support for Contact ID, Pulse, or Bosch Modem Ile or Modem IIla2 • Easy installation in DynaNet subscriber • Operates in applications with or without a phone line DYNA�ET WIRELESS ALARM MONITORING Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2-way communications capability provides easy installation, expansion, and management when compared to alternative communication methods, both wired and wireless. YNAFIRE ADVANCED WIRELESS ALARM MONITORING The DynaNet mesh radio network offers unmatched reliability and speed in delivering wireless alarm signals to a central station without third party fees or reliance on networks owned by companies outside the security and fire alarm industry. DynaNet 7788 F Series Smart Subscriber Transceivers provide the wireless communication link between the fire alarm panel and the central station receiver. The 7788 F Series is ideal for most commercial fire alarm applications. Each 7788 F Series Subscriber is housed in a full sized, red, locked, steel cabinet and supports a range of alarm panel inputs including EOL fire, EOL supervised, and direct voltage from the panel (nonfire applications). SUPERVISED OPERATION DynaNet Subscribers offer fully supervised operation that includes monitoring of operating power (both primary AC power and battery backup) and the connection to the radio network. Each Subscriber "checks in" with the DynaNet central station receiver at least once every 24 hours. The supervision check in time can be set for as often as once per minute and, because DynaFire owns the wireless network, there is no additional cost for airtime to transmit supervisory signals. FULL DATA REPORTING FROM ALARM PANEL DIGITAL DIALER Model 7788 F-ULP comes equipped with an IntelliPro Fire Full Data Module (DynaNet-7794) which enables reporting of full alarm data captured from the fire alarm panel's digital communicator. IntelliPro Fire supports most alarm communication formats including Contact ID, Pulse, as well as Bosch Modem Ile and Modem Illa2. DynaNet Models Model Description 4 Zone Fire Alarm 7744F Subscriber with 4 reverse polarity inputs 7788 F 8 Zone Fire Alarm Subscriber 7788 F-ULP 7788 F Fire Alarm Subscriber with IntelliPro Fire full data module Optional Accessories 7041 E Subscriber Handheld Programmer 7794 IntelliPro Fire Full Data Module C&Us LISTED gvvl ® 7788 F SERIES SUBSCRIBERS Dimensions • 13.25"H x 8.5"W x 4.3"D (34cm H x 21.5cm W x 11 cm D) Weight • Approx. 7 pounds (3.2 kilograms), excludes battery. Radio Frequency • Standard Frequency Range: 450-470MHz (others available) • Output Power - 2 Watts (others available) Antenna • Included 2.5 db tamper resistant antenna mounts on enclosure • Multiple remote antenna options available Power Input • 16.5VAC, 40VA (transformer not included) Backup Battery • Will charge 12V battery up to 7.5 AH. Requires 12VDC 7.5 AH battery for UL 864. Alarm Signal Inputs (subscriber) • 7788 F— 8 individually programmable zonesL UL Standards • UL 864 Edition 9 — Standard for Control Units and Accessories for Fire Alarm Systems • UL 365— Standard for Police Station Connected Burglar Alarm Units and Systems • UL 1681 —Standard for Central Station Burglar Alarm Units Mi HOMO Antenna Cut / Communication Trouble Output • Form C relay; fail secure; rated for 24 VDC 1 A resistive <— Reset Button • Located on main circuit board. Operating Temperature • 0° to 50° C (32' to 122°F) Storage Temperature • -10' to 60' C 04' to 140°F) Relative Humidity • 0 to 85% RHC, Non Condensing 7794 INTELLIPRO FIRE Input / Output Connections • RJ11 connection to AES subscriber for module data and power • RJ11 connector for Handheld Programmer/PC programming • RJ31 X Telco connections - T and R both in and out via terminal strip and RJ45 • Alarm Panel digital communicator T and R both in and out via terminal strip and RJ45 • Trouble output: Form C relay detects if Subscriber is off the network Alarm Formats • Support for Contact ID and Pulse formats as well as Modem Ile and Modem IIla2 converted to CID Size • 2.8 x 5.0 inches (7.1 cm x 12.7cm) Power Requirements • 12 VDC nominal - primary and backup power provided by the DynaNet 7788 Fr A Wireless ® Y N /'1 E T I Alarm Monitoring SEC Prima Vista 8/16/2019 Fire Alarm System Addressable Devices DN-60979:A NP-200 Series Addressable Photoelectric Detectors General The NOTIFIER NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modem, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series Addressable Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indi- cation. Dual electronic thermistors add 135'F (57'C) fixed tempera- ture thermal sensing on the NP-200T. The NP-20OR is a remote test capable detector for use with DNR Series duct detector housings. Features SLC LOOP • Two -wire loop connection. • Unit uses base for wiring. ADDRESswo • Addressable by device. • Rotary, decimal addressing: Please refer to the FireWarden pane/ manuals for device capacity. ARCHITECTURE • New modem profile for improved aesthetics. • Unique single -source design to respond quickly and dependably to a broad range of fires. • Integral communications and built-in type identification. • Built-in tamper -resistant feature. • Removable cover and insect -resistant screen for simple field cleaning. OPERATION • Designed to meet UL 268 7th Edition. • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. • Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. • Low standby current. MECHANICALS • Sealed against back pressure. • Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS • Remote LED output connection, RA100Z. Installation NP-200 series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. (�J NOTI FI E R° by Honeywell NP-200 in B300-6 Base Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE., Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T--taps" or branches are permitted for Style 4 (Class B) wiring. NP-20OR mounts in a DNRIDNRW duct detector housing. Operation Each NP-200 Series detector uses one possible addresses on the FireWarden Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire - Warden Series for record keeping. Specification Voltage range: 15 — 32 VDG (peak). Standby current: 200 pA ® 24 VDC. Max current: 4.5 mA (9 24 VDG (latched "ON"). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Sensitivity: UL Applications: 0.5 % to 4.0% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. — B300-6: 6.1' (15.6 cm) diameter. — B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). Operating temperature range: • NP-200: 0"C to 50oC (32°F to 122"F); • NP-200T: D'C to 38oC (32'F to 100"F). • NP-20OR: installed in a DNR(A)/DNRW -20"C to 70oC (-4oF to 158"F). DN-69979:A • 3/29/18 — Page I of 3 Relative humidity: 10%-93%, non -condensing. Listings and approvals below apply to the NP200 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listed: S911 • CSFM: 7272-0028:0503 • FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed \\�.1 below. NOTE: "IV" suffix indicates FlashScanO and CLIP device. NP-200: White, Addressable photoelectric detector; B300.6 base included. FlashScan only. NP-200-IV: Ivory, Addressable photoelectric detector; B300-6 base included. NP-200T: White, Same as NP-200 but with thermal element, B300-6 base included. FlashScan only. NP-200T-1111: Ivory, Same as NP-200 but with thermal element; B300-6 base included. NP-20OR: White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. FlashScan only. NP-200R4N: Ivory, Remote test capable addressable photoelectric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60961. B300.6: White, 6" base, standard flanged low -profile mounting base. (CSFM. 7300-1653:0109 Pending) 9300-6-IS: White, 6" base isolator. (CSFM: 7300.1653:0109 Pend- ing) B300-&IV: Ivory,6" base, standard flanged low -profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6. ULC listed. 13300A-0411: Ivory, 6" standard flanged low -profile mounting base, ULC listed. 8300.6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653.,0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B5014V: Ivory color, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109 Pending) B501BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653.,0216 Pending) B224RI34V: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-N: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224BI-N: Ivory Isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B20CS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol.. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S4V, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653.,0238 Pending) B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0236 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300.1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653.,0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN{0979:A • 3129/18 — Page 2 of 3 NOTIFlERO and FIREWAROEN® are a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ® All specifications are subject to change without notice. Q UAIIT BMANOfTEMS Q OIIlI7T SYSTEMS For more information, contact Notifier.Phone:(800) 627.3473, FAX:203484-7118. ( ) www.notifier.com Page 3 of 3— 0N-60979:A • 3129/18 DN-6999:E Monitor Modules NMM-100(A), NMM-100P(A), NZM-100(A), and NDM-100(A) for FireWarden Series General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry -con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry -contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of drycontact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single -gang box behind the device it monitors. NZM-100(A) is a standard -sized module that monitors and supervises compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard -sized dual monitor module that monitors and supervises two independent two -wire Style B (Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two wire sys- tems. LiteSpeed' is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM-100(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 99 on FireWarden-100- 2, 01 — 50 on FireWarden50. • LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two -wire or four -wire fault -tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry, -contact alarm activation devices. May also be used (�J NOT 1 F i E R® by Honeywell NMM400(A) (Type H) to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32"F to 120"F (0"C to 49"C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11 A3 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-i OOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. ON-6999:E • 07/302015 — Page 1 of 4 Powered directly by two -wire SLC loop. No additional power required. High noise (EMFIRFI) immunity. Tinned, stripped leads for ease of wiring. Direct -dial entry of address: 01 — 99 on FireWarden-100-2, 01 —50 on FireWarden-50. 141 01 O 01 ��13 2 �2 O 4 LOOP O 4 1098 7 65 98 7 65 TENS ONES I @ S ca The NMM-100P(A) Mini Monitor Module can be installed in a single -gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelli- gent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a two - wire initiating device circuit for normally -open -contact fire alarm and security devices. NMM-100P(A) NMM-100le(A) APPLICATIONS Use to monitor a single device or a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally -open dry -contact devices. May also be used to monitor normally -open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuiUdevice is wired as an NFPA Style B (Class B) Initiating Device Circuit A 47K Ohm End -of -Line Resistor (provided) terminates the circuit. NMM-1001P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:450 pA. EOL resistance: 47K Ohms. Temperature range: 32'F to 120'F (O'C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM-100(A) Interface Module • Supports compatible two -wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry entry of address:, 01— 99 on FireWarden- 100.2, 01 —50 on FireWardenSO. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two -wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two -wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPucanoNs Use the NZM-100(A) to monitor a zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ nornallshort) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFlcArioms Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIC and T11): • DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Temperature range: 32'F to 120"F (0"C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DW6999:E • 07/30/2015 NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in Intelligent, two -wire systems. It provides two independent two - wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel - controlled LED. NOTE: The NDM-100(A) provides two We B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26, then it will automati- cally assign itself to addresses "26" and "27° NOTE: "Ones" addresses on the NDM-100(A) are 0, Z 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power -limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electd- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635. • ULC: S635. • FM Approved. • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100). • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: A"sutFx indicates ULC-listed model / NMM-100(A):Monitor module. NMM400P(A): Monitor module, miniature. NZM400(A): Monitor module, two -wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. ON-6999:E • 07130/2015 — Page 3 of 4 Notified and FimWarden® are registered trademarks and UteSpeed- and FireWatch" are trademarks of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 81CIMMM I MMIMCMG All specifications are subject to change without nofice. QUALITY SYSTEMS For more information, contact Notifies Phone: (203) 484-7161, FAX: (203) 484-7118. www.notReccom Page 4 of 4 — DN-6999:E • 07/30/2015 dn-7000:a2 • A7-360 NC.100(A) Control Module for FireWarden Series Panels General The NC-100(A) Addressable Control Module provides NOTI- FIER's FireWarden Series intelligent control panels a super- vised Class B (Style Y) of Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the NC-100(A) to be activated, either manually or through panel programming, on a select (zone or area of cov- erage) basis. Features • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry powered directly by two -wire SLC loop. The NC-100(A) module requires power (for horns, strobes, etc.). • Integral LED "blinks" when communicating, and turns on steady when activated. • High noise immunity (EMF/RFI). • The NC-100(A) may be used to switch 24-volt NAC power. • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 — 99 with FireWarden- 100-2(% or 01 SO with the FireWarden-50(0). Applications The NC-100(A) is used to switch 24 VDC audibieMsual power. Construction • The face plate is made of off-white heat -resistant plastic. • Controls include two rotary switches for direct -dial entry of address setting. • The NC-100(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. Operation Each NC-100(A) uses one of the module addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normallshort status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The NC-100(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the NC-100(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay -isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. �J NOT 1 F 1 E R° by Honeywell EnNMltl •cNt• NC-100(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 350 pA (LED flashing). External supply voltage: maximum 80 volts (RIMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32•F to 120"F (0'C to 49•C). Humidity range: 10% to 93% non -condensing. Dimensions: 4.5° (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125' (5.398 cm) deep box. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fao- Cory for latest listing status. • FM approved • ULNLC Listed: file S635. • CSFM approved: file 7300-0026:230. • MEAapproved: file 72-01-E Vol. 2. dn.7000:a2. OW77110—Page 1 of 2 Contact Ratings Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non -Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non -Coded .9 A 125 VDC Resistive Non -Coded .5A 30 VDC Inductive Coded (UR=5ms) 1 A 30 VDC Inductive Coded (UR=2ms) .3 A 125 VAC Inductive (PF=0.35) Non -Coded Inductive 1.5A 25 VAC (PF=0.35) Non -Coded Inductive .7 A 70.7 VAC (PF=0.35) Non -Coded Inductive 2A 25 VAC (PF=0.35) Non -Coded Product Line Information NC-100: Intelligent addressable control module. NC-100(A): Intelligent addressable control module, ULC listed version. SMB500: Optional surface -mount backbox. CB500: Optional control module barrier, required by UL for separating power -limited and non -power -limited wiring in the same junction box as NC-100(A). NOTE: For installation instructions, see document 156-2592-001 and reter to the SLC tiring Manual, document 52304. The NC- 100R(A) relay module, previously on this data sheet, is now on DN-60363. NOTIFlER® is a registered trademark of Honeywell International Inc. @2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ffm�=! We cannot cover all specific applications or anticipate all requirements. HIMME SMANIF90116 All specifications are subject to change without notice. QUALITY SYSTEMS Madeinthe U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifieccom Page 2 of 2 — dn-7000:0.06/17/10 DN-7001:0 • A1-380 NOT-BG12LX Addressable Manual Pull Station General The Notifier NOT-BG12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BGI2LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 pA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 320F to 120"F (0'C to 49'C) • Relative Humidity: 10%to 930/ (noncondensing) • For use Indoors in a dry location Installation The NOT-BG12LX will mount semi -flush into a single -gang, double -gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SBA 0 or SB-VO sur- face backbox. If the NOT-BG12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. �J NOTIFIER® by Honeywell The NOT-BG12LX Addressable Manual Pull Station The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 99 on NFW2-100/NFW2-100C, 1 — 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed nN-7001:D • 4/73l2012 — Pagel of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian applications.) SBA 0: Surface backbox; metal. SB-UO: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non -Cana- dian applications). • MEA: 67-02-E Vol. W. • CSFM: 7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO is a registered trademark of Honeywell Intemational Inc. C2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not Intended to be used for installation purposes. We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. �IIf�MINLBfARftI@fll®Yb, All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484.7118. www.notifier.com Page 2 of 2 — DN-70010 • 4/132012 DN-60429:C1 DNR(A)/DNRW InnovairFlex Intelligent Non -Relay Photoelectric Duct Smoke Detector General The Notifier InnovairFlex® DNR(A) intelligent non -relay photo- electric duct smoke detector and DNRW watertight non -relay photoelectric duct smoke detector feature a pivoting housing that fits both. square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, Is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -40F to 158OF (-20•C to 700C), and a humidity range of 0 to 95 percent (non -condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly Installed sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-Inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low -flow technology. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s). • Versatile mounting options: square or rectangular configu- ration. • Broad ranges for operating temperature (-4•F to 158•17, - 20•C to 70•C) and humidity (0% to 95% non -condensing). • Patented sampling tube installs from front or back of the detector with no tools required. • Cover tamper signal. • Increased wiring space with a newly added 39" conduit knockout. • Available space within housing to accommodate mounting of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). • Clear cover for convenient visual inspection. • Remote testing capability. • Requires cam line power only. • Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NO.10019) for applica- tions requiring a Form-C relay. (J NOT 1 F 1 E R° by Honeywell Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4 F to 158'F (-20•C to 70°C). Storage Temperature Range: -22•F to 158•F (-30°C to 70•C). Operating Humidity Range: 0% to 95% relative humidity (non -condensing). Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote -test -capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA1 OOZ OmA 12 mA Max RTS151/ DmA 12mA Max RTS151KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S911, S3705. • ULC: 5635. ON-60429:C1 •4/192012—Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE: A suffix indicates ULC listed model. DNR(A): Intelligent non -relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non -relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851R(A): Remote test capable addressable low -profile photoelectric smoke detector. FSP-851(A): Addressable low -profile photoelectric smoke detector. NP-100: Addressable low -profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low -profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 It to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DSTS(A): Metal sampling tube duct widths up to 4 It to 8 It (1.2 Ito 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). D1114000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magriet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. <— RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. NotifierO and FlashScanO are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I V O 9U01 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MAA�I E MAhT@CI®IM NI specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Nofrfier. Phone: (203) 464-7161, FAX: (203) 484-7116. www.notifiencom Page 2 of 2— DN-60429:Cl • 4/19/2012 SEC Prima Vista 8/16/2019 Fire Alarm System Notification Appliance Devices Z4SYSTEM NSO Indoor Selectable= Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95.110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings ataxwxa LISTED S5512 I'M aP,.ed eM 1 ?1ii w 51g11 fa AlDirnodch n3S16i.M aasrdas, msrmx The System Sensor L-Series offers the mast versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that Increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is Installed. Installers can also easily adapt devices to a suit a wide range of applicationrequirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AOSgfi5Q5 • V2] 18 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/e-inch back box, 4 x 4 x lyrinch back box, 4-inch octagon back box, or double -gang back box. L-Sedes compact products shall mount to a single -gang 2 x 4 x 17A-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, LSeries products, when used with the Sync•Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75. 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Ham Strobe Combination The horn strobe shall be a System Sensor LSeries Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411116 x 411/16 x 2'/6-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Strobe Flash Rate Nominal Voltage Regulated 12 DC or regulated 24 DG/FVVHI Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InnutTerminal Wire Gauae 12 to 18 AWG Wall -Mount Dimensions (Including lens) 5.6-L x 4.7'W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions Qncluding lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Ham Dimensions 5.6-L x 4.7"W x 1.25"D (143 mm L x 119 mm W x 32 mm D) Compact Ham Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 ed. Avnsaesos-vrr a -cages ao IP� a N 0 �i :v O A A I W V W W N N L-Series Dimensions tn• yy ,�. .35mn emm ,�• 35T ,�- Bem L33' 3xmm 1;1 vnl oa mn) 32. F ,r, o ICSR' Jiw.1• O IDi9 mm 53T , rySi ae) o ss9mm i1 „ n Psa nxa7-90 nosh-oo Compact Strobe, Ham Strobe Compact Ham Compact Wall Surface Mount Back Box SBBGRL, SBBGWL ..r (t.95 CI,) 119 mm dY mein • uV tm.10 (S1emm) p � ® o _� i� x3• O ryArun) 1Mmm ,,,'e 'nb3 mnl 443i i� Strobe, Mom Strobe A0�O00 Horn Wall Surface Mount Back Boxnas of SB13RUSBBWL L-Series Ordering Information likhr-T-171 I. . Model Description Ham Strobes Homs` P2RL 2-Wire, Horn Strobe, Red HRL` Horn, Red P2WL 2-Wire, Horn Strobe, White HWL` Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRLSP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT HGRL` Compact Horn, Red HGWL• Compact Horn, White TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no'FIRE" marking on cover). All SP models have "FUEGO" marking on cover. All -ALERT models have'ALEFT° marking on cover. *Horn -only models are listed for wall or ceiling use. O "STEW Phone: Ohio Avenue • St. Charles, IL 60174 ®m,e syvem sm,so.. Phone: 800SENSOR2 • Fax: 630-377-6495 emmm umscuhleaatlwgeximo,ammcaV� ym,,,mww„ Cw, /'f p ,vamemmamdu+bmm�uem muum,y me iseavuum orw:asadwn. SEA/so�° viww.systemsensoccom nvosassos•vzzn_ate SEC Prima Vista 8/16/2019 Fire Alarm System Wire CABLE SPECIFICATIONS DESCRIPTION CONDUCTOR INSULATION COLOR CODE SHIELD DRAIN WIRE JACKET JACKET COLOR MARKING OVERALL DIAMETER CABLE WEIGHT. SMARTWIHE GL/O T E C H N O L O G Y 16 AWG 2 Conductor Bare Copper, Non -Shielded Plenum Fire Alarm, UL C(UL) CMP or FPLP UL 16 (Solid Bare Copper) i Low -Smoke PVC .O1D" Black/Red! a--, N/A Low -Smoke PVC.018" Red Jacket—_ 16 AWG CAPACITANCE I 26fpF/Ft. Nam. IMPEDA fCE L-72.Ohms/Mft. DC RESISTANCE 4.10 Ohms/Mft @ 20 deg. C RATURE RATING j0 Ctg75 C / 300 Vol[ ,f INDUSTRY AGENCY UL ILME4.RATINGApproved For Plenum Use Without Conduit Per ' it,!, _ �.1, ., i 1, t APPROVALS NEC Article 800, 760; UL C(UL)'CMP or FPLP. U I UL cRUM DEVICE /IZONEABCDE0123456789 7 j I j i j i R S ! CABLE SMART WIRE CAL/O . DESCRIPTION 16 AWG 4 Conductor Bare Copper, Twisted, Non -Shielded Plenum Fire Alarm, FPLP (UL) CONDUCTOR 16 (Solid Bare Copper) INSULATION Low -Smoke PVC.010" COLOR CODE Black/Red/Brown/Blue LAY LENGTH 4.0" LHL (3 TPF) SHIELD N/A DRAIN WIRE N/A JACKET Low-Smake-PVC .018" JACKET COLOR Red Jacket! I MARKING FIRE/LIF.E SAFETY -"CON 1fiAWG-FPLP (UL) ( RC OVERALL DIAMETER CABLE WEIGHT i CAPACITANCE IMPEDANCE TEMPERATURE RATING 'e .1 'i f INDUSTRY AGENCY Nam 72 Ohms Nam. i i; E1 i 5's IL CABLE INITt/iIND'. DEVICE /,ZONE A B�C D E 0 1 2 3 4 5 6 7 8 9 MADE IN THE USA! ( i C / 300 Volt for Plenem Usle Without Conduit Per NFPA 262 Flame Test 760; FPLP (UL), RoHS-Compliant; Made in the USA 7 f 1 All specifications referenced are nominal measurements unless otherwise noted. CABLE SPECIFICATIONS DESCRIPTION CONDUCTOR INSULATION COLOR CODE LAY LENGTH SHIELD DRAIN WIRE JACKET JACKET COLOR MARKING .- OVERALL DIAMETER j CABLE WEIGHT 1, t CAPACITANCE IMPEDANCE OC RESISTANCE INDUSTRY STAP FLAME AGENCY SMAR'tW IRE -^- GL/O E C H M U L 4 G V 18 AWG 2 Conductor Bare Copper, Twisted, Non -Shielded Plenum Fire Alarm, FPLP (UL) 18 (Solid Bare Copper) Low -Smoke PVC .010" l Black/Red 3.0" LHL (4 TPF), •s I N/A ' I N/A y i ?'I E Low-SmokeAVC.018"..s t I Red Jacket i.-f FIRE/LIFE SAFETY C6NTROL CABLE INIT'/;IND:,DEVICE /�ZONE'A B,C D E 0 1 2 3 4 5 6 7 8 9 18AWG-OLP (UL) 4 ROHS1 MADE IN THE.USM t .158," Nom.- 221bs/Mft. t 1 t l 22 pF/Ft. Nom. `— I 86 Ohms 6.52 Ohms/Mft @ 20 deg. C t ( y 1 r r �0 C to'75 C / 300 Volt 1 't {{ 11 i li f t if Approved For Plenum UeWithout,.Conduit.P:r NFPA 262 �Flame Test NEC Article, 760{+'FPLP (Ul_ ; RoHS Compliant; Made mtthe USA/ 'S All specificabons referenced are nominal measurements unless othemise noted. SMAFO WIR Gesso T E C H N O t O G Y CABLE SPECIFICATIONS DESCRIPTION 14 AWG 2 Conductor Bare Copper, Non -Shielded Plenum Fire Alarm, FPLP (UL) CONDUCTOR 14 (Solid Bare Capper) ; "? ; -a INSULATION i Low -Smoke PVC .010" COLOR CODE Black/Red SHIELD N/A 1 e; DRAIN WIRE N/A > (+ JACKET Low -Smoke PVC .018" i- f y; JACKET COLOR Red IackeEWittfBl9ck Stripe:{ - MARKING I FIRE/LIFE SAFETY CONTROL CABLE INIT /lIND._DEVICE NE.A,B C D E 0 1 2 3 4 5 6 7 8 9 14 AWG FPLP (UL)LROHSs MADE IN THE USA; I } , f 1 OVERALL DIAMETER .206j-No4 ; p CABLE WEIGHT 3 {i361Lbs/Mft. CAPACITANCE 9 pF/Ft. Nom. IMPEDANCE 72 Ohms/Mft. DC RESISTANCE 2.57 Ohms/Mft @ 20 deg. C INDUSTRY 9 AGENCY All speciffcatlons referenced are nominal measurements unless otherwise noted. SEC Prima Vista 8/16/2019 Fire Alarm System Surge Suppression Devices Standard_ Features_ : • Available in 120 VAC • UL Listed 1449 3rd Edition Type 2 & 3 • Includes lockout & labels per NFPA 72 2013 10.6.5.2 • Surface or conduit mounting • Diagnostic indicator light • Self restoring • 3 Wire device (18° length) Protection Safety and performance is what Eclips is all about. While there are many varying criteria to be considered for surge protective devices (SPD), if the design engineer neglects the importance there can be serious implications for the client and equipment. Every piece of electrical equipment is designed to operate at a specified nominal voltage. Typically equipment is designed to handle minor variations. However external sources such as lightning, motors, and short circuits cause wild and damaging variations. Critical systems wired to your electrical service like Fire Alarm Control Panels (FACP), Mass Notification systems, amplifiers, motors, pumps (HVAC), power boosters and many more must require appropriate levels surge protection. The E120 series is an ideal choice for your 120V AC applications. because it has the robustness not only to absorb a spike, but to clamp long enough to trip the branch circuit breaker and still be functional for additional surges. The number one cause of destruction, degradation and down- time of critical electrical equipment isfrompower surges lightning strikes. The El20V-GT device is an ideal solution to protect equip- ment. UL listed it maintains system integrity and protects against transients introduced into / onto electrical lines via poor atmospheric and utility conditions as well as internally gener- ated inductive loads and transient TVSS. It reduces system downtime associated with power surges and lightning strikes. Prevents destruction and degradation of electrical components in the system. Fix your nuisance and non -billable service calls as a result of transients and poor power quality and show your customer you care about system integrity. ISO 9001 REGISTERED W COMPANY Made In U.S.A. NFPA Uses UL Recognized Components •% r,;MINA Space Age Electronics, Inc. 2013 LT10629 Rev.6 1/2 OF Space Age Electronics, Inc. www.ISAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! (SPACE AGE WW ELECTRONICS, INC. Specifications: All 120volt AC equipment will have Transient Voltage Surge Suppression (TVSS) protection manu- factured by Space Age Electronics, Inc., part number E120V-GT ECLIPS Brand. The Unit shall be UL listed to standard 1449 rev 3. The unit will be labeled clearly with indelible ink. Mounting can be con- duit mounted with a %" pipe threaded nipple to secure in panel, or surface panel mount with 2 external mounting holes. The unit shall have thermal fuses to protect against fire in short circuit conditions. The El20V will have 18" long, 14 gauge wires (3x) ground wire must be green. The enclosure will be a non dielectric material UL94 QMFZ2/8 grade material providing UV protection. The unit shall provide visual indication (LED) that unit is protecting and functioning. Specifications - Performance: Short Circuit Current Rating (SCCR) : 5KA Enclosure Material: UL94 QMFZ2/8 (green) VPR=700(L — N) 700 (L — G) 600 IN — G) Capacitance: < 2,000 pf Clamping Response Time: < 5 nanoseconds Current: Non -Load Bearing Max Operating Voltage (MCOV) : 140 volts AC, 50/60 Hz Design : Thermally Fused Hybrid Operation Indicators : LED Specifications - Operating: Service Voltage: 120 Single Phase Circuits Protected : L-N L-G N-G Connection Type: Hardwired Installation Configuration: Parallel Specifications - Physical: Weight Dimensions Operation Temperature Mechanical Drawing: Specifications - Compliance: F UL Listed: 1449 Third Edition - VZCA 1.5" 2 1" File Number: E319370 Vol.1 Sec.1 O Wiring Diagram:L-2.6" Breaker panel T 1r—1 Protected Device Space Age Electronics, Inc. www.1SAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description 5.2oz 2.75" x 1.55" x 4" long -40 to +850 C 4.4" E120V-GT 120V Hybrid Surge Protective Device ELOCK-FA Circuit Lockout Kit This document is subject to change without notice, see doc # ED0479 for legal disclaimer LT10629 Rev.6 2/2 LVLP Series Voice, Data and Signaling Circuit Surge Protection J _ D.ITEK1 General Product Specifications DITEK's Low Voltage Line Protector series of signal, data and loop circuit surge protectors provide strong protection in a compact hard wire package. Applications DTK-4LVL include protection of 4-20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. Models are available to protect 1, 2, 4 or 8 pairs. LVLAWG models can handle #14410 AWG wiring connections. DTK-LVLP Selection Guide Application Features • Series connection, parallel function adds no resistance to loop circuits • Protect 1, 2, 4 or 8 pairs to match your configuration needs • Seven voltage levels available to protect all types of voice/data/loop applications • "SCP" model provides automatically resetting fusing and sneak current protection Specifications Agency Approvals: UL497B, UL497A Connection Method: #22416 AWG screw terminals (LVLP), #14410 AWG screw terminals (LVLAWG) Max Continuous Current: 5 Amps, 0.15 Amps (-SCP) Max Surge Current: 2,000 Amps per pair (6V-50V) 9,000 Amps per pair (75V-130V) Protection Modes: Line -Ground (All) Operating Temperature: -40"F - 158"F (-40"C - 70"C) Maximum Humidity: 95% non -condensing Dimensions: 1 LVL-4LVL —1.6"H x 3.0"W x 1.6"D (41 mm x 76mm x 41 mm) 8LVL —1.5"H x 4.8"W x 2.3"D (35mm x 122mm x 58mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty Accessories: DIN Rail Kit— Part Number DTK-DRK DTK- # #LVL# # # SAD -Based: "Z" I Number of Pairs:: 1, 2, 4, 8 Wire Gauge: "P" for #22-16, "AWG" for #14-10 Sneak Current Protection: .1 5A current, "SCP" Voltage Level: D, X, LV, OPX, SPK, SGR, RUV (see table below for voltage ranges) Example:_ DTK-4LVLPSCPD Example: DTK-8LVLAWGRUV Example: DTK-Z4LVLPLV Performance Data Model DTK-LVL# Service Voltage MCOV Clamp Voltage D 0-6 V 8VDC 12V X 14 V 18VDC 22V LV 30 V 38VDC 47V OPX 50 V 66VDC 82V SPK 75 V 102VDC 120V SGR 95 V 127VDC 150V RUV 130 V 175VDC 204V ISO 9001-2000 1 C L US One DITEK Center 1-800-753-2345 Direct: 727-812-5000 Doc. Number. SPS-100030-001 Rev 2 9-07 1720 Starkey Road Technical Support:1-888-472-6100 ©2007 DITEK Corp. Largo, FL 33771 www.ditekcoro.com Specification Subject to Change SEC Prima Vista 8/16/2019 Fire Alarm System Batteries DN-6933:D • E-205 BAT Series Batteries �J NOT 1 F 1 E R° Sealed Lead -Acid by Honeywell Power Supplies General BAT Series Batteries are Power -Sonic brand batteries. BAT Series (or Power -Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leak -proof construction. • Ruggedly constructed, high -impact case (ABS). • Long service life. • Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Recognized Components: MH2O845 (Power -Sonic) Part Number Reference & Specifications 6W..1Gg Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH). BAT-1270•BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH). BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH). BAT-12180-SP: 2-unit bulk pack of BAT-12180 (12 V 18 AH). BAT-12260-BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH). BAT-12550: single battery (12 V 55 AH). BAT-1 21000: single battery (12 V 100 AH). Part Number Power-, Sonic Part Number Battery Description DIMENSIONS Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. width Depth Height Height over terminal Weight In. mm in. mm In. mm in. mm lb. kg. BAT-1250 PS-1250 7 2 - 6 -- seated3.54 90 2:76- 70 3.98 0 4.2 07- 3.50 - .59 BAT-1270 PS-1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 3.00 76 6.59 167 6.59 167 12.6 5.72 BAT-12260 PS-12260 12 26 sealed 6.5 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12550 12 55 sealed 9.04 230 5.45 138 8.15 207 8.98 228 36 16.33 BAT-121000 PS-121000 12 100 sealed 12 W5 6.6 168 8.15 1207 8.98 228 68 30.84 DN-69330 • 02/2812013 - Page 1 of 2 n Discharge Characteristic Curves at 200C (680F) For6V For12V BaOcry BaHery 6.5 13.0 p 6.0 12.0 5.5 11.0 D.tOC. DaSC q 0.40C GC 5.0 10.0 - 0.60C - c 2C 1C M 4.5 9.0 4.0 r 6L 0 100 O 80 c 0 a 60 K 0 40 n m 1 2 4 6 6 10 20 40 60 2 4 6 810 20 Minuiez z4- Houn -a Discharge Time PS-121000 Shelf -Life and Storage I Gw,ry0'snA )� neo?ssaryunles ttt 100%Aapazil! 5°c �� useBneceb� ({ tOhelp Omver (41°F) .(} twapaory. q Ma }lilt{4 �tlry. Do trot 40°C 3 °C 20°C (104°F) (86°F) (gg° letwft;esrme IIIISk tlfissrate. { 1 V 00 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 Ambient Temperature 20°C fib°F t3.0 12.0 m c 11.0 N 10.0 E m` F 9.0 8.0 1.2 2.4 6 12 24 36 48 1 2 4 6 810 20 40 in 11 h Discharge Time eQwi S Effect of Temperature on Capacity 120 110 e s0 m 60 3 40 20 0 40 -30 -20 -10 0 10 20 30 40 50 60 Temperature(-C) 0.05 c 0.10 C 025 C 0.50 C tc NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. 02013 by Honeywell International Inc. All rights reserved- Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. OWNRAE 5 MAHM I MI✓6 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifies Phone: (203) 484-7161, FAX: (203) 484-7118. www.notdlercom Page 2 of 2 — DN-6933:D ° 02/28/2013