Loading...
HomeMy WebLinkAboutFENCE PLANSCANNED BY St. Lucie County 2j'xl�'xO.062' ALUM, CAP 5' MAX. 3.9' L--:i±BTW. PICKETS 5' BOTTOM RAIL ATTACHED TO POST 34' a W/ L 1'xl'xl'xh' CONCRETE FOOTING 34' d 3,000 PSI MIN. I, ,�ls•�f' �ls, 5' HIGH POOL FENCE DETAIL (N.T,SJ STRUCTURAL NOTES, 1. DESIGN COMPLIES WITH FBC 2017, SIXTH EDITION AND ASCE 7-10. 2. ALUMINUM EXTRUSIONS SHALL BE 6063-T6 GRADE. 3. CONCRETE STRENGTH FOR GATE POST FOOTINGS SHALL BE MIN 3,000 PSI, 28 DAY COMPRESSIVE STRENGTH, 4. WIND DESIGN PRESSUREi - 150 MPH - CATEGORY II - EXPOSURE C. 2x2'xO.125' ALUM. POST J'xj'x0,062' ALUM, PICKET 1'x2'xO.093' ALUM. BOTTOM CHANNEL GENERAL NOTESi 1. BRONZE POWDER COATED FINISH. ._I STRUC 1, D 2. AI 3. CI PSI, 2 4. WIND DESIGN PRESSURE, - 150 MPH - CATEGORY II - EXPOSURE C. GENERAL NOTES, 1, BRONZE POWDER COATED FINISH. DATE 11/07/2019 WIND LOADS 34 Wind Pressure (psf) 90 Panel Length (in) 60 Panel Height (in) 0.75 Picket Horiz Dim (in) 58 Picket Vert Dim (in) 2 Bott Rail Vert Dim (in) 2 Post Horiz Dim (in) 10.88 Tributary Area (ftA2) 369.92 Wind Load at Post Center (Ibs) POST DESIGN 30 h at Load (in) 369.92 Load (Ibs) 2 Post Sq Dim (in) 0.125 Post Thickness (in) 11097.6 M (lb -in) 0.551758 S (inA3) 20113.17 fb (psi) < 24,000 psi FOOTING DESIGN (Unconstrained 2.5 h at Load (ft) 369.82 Load (Ibs) 18 Ftg Diam (in) 39 Ftg Depth (in) 300 Lat Bearing Pressure (psf) 325 S 1.775136 A 39.11137 Depth (in) Tributary Area (ftA2) = 10.88 Allowable Lateral Pressure Sand 150 psf/ft x 2 P = 125 (2.5) / 2.5 P P = 125 LBS 2.5 ft 39" > 125 Ibs Yamil Kuri, P.E. Fla Reg No. 44726 Civil/Structural 511 San Juan Drive Coral Gables, FL 33143 (786)290-7283 Wind Pressure Calculation qz = [0.00256 (Kz) Kzt (Kd) VA2] G (Cf) qz = 0.00256(0.85)1.0(0.85)150A2(0.85)1.6 qz = (56.6) x 0.6 = 34 PSF Risk Category II Exposure C >_ [(90 x 58) / 144] x 0.30 = 10.88 OK = 300 psf 0'1 WIND LOADS 34 Wind Pressure (psf) 150 Panel Length (in) 60 Panel Height (in) 0.75 Picket Horiz Dim (in) 58 Picket Vert Dim (in) 2 Bott Rail Vert Dim (in) 2 Post Horiz Dim (in) 18 Tributary Area (ftA2) 612 Wind Load at Post Center (Ibs) > 500 Ibs POST DESIGN. 30 h at Load (in) 612 Load (Ibs) 2.5 Post Sq Dim (in) 0.125 Post Thickness (in) 18360 M (lb -in) 0.895573 S (inA3) 20500.84 fb (psi) < 24,000 psi FOOTING DESIGN (Unconstrainedi 2.5 h at Load (ft) 612 Load (Ibs) 18 Ftg Diam (in) 48 Ftg Depth (in) 300 Lat Bearing Pressure (psf) -400 S 2.3868 A 48.10934 Depth (in) Tributary Area (ftA2) = 18 >= Allowable Lateral Pressure Sand 150 psf/ft x 2 = P = 250-(5) / 2.5 P �P = 500 LBS 2.5 ft 48" Yamil Kuri, P.E. Fla Reg No. 44726 Civil/Structural 511 San Juan Drive Coral Gables, FL 33143 (786)290-7283 ih ` Wind Pressure Calculation qz= [0.00256 (Kz) Kzt (Kd) VA21 G (Cf) qz = 0.00256 (0.85) 1.0 (0.85) 150A2 (0.85) 1.( qz = (56.6) 0.6 = 34 PSF Risk Category II Exposure C [(150x58)/144]x0.30=18 OK 300 psf I . SCANNED BY St. Lucie County 20' (V,I,FJ 3,9' MAX. BTW, PICKETS 5' 48 1�18,4 EU2' 2x2'xO,125' ALUM, GATE FRAME DROP ROD 2'x�' ALUMINUM FLAT BAR CONCRETE FOOTING 3,000 PSI MIN, DOUBLE SWING GATE .DETAIL m•t�;7 >..' qga (N.T.S.) STRUCTURAL NOTES: 1, DESIGN COMPLIES WITH FBC 2017, SIXTH EDITION AND ASCE 7-10, 2. ALUMINUM EXTRUSIONS SHALL BE 6061-TG GRADE, 3, CONCRETE STRENGTH FOR GATE POST FOOTINGS SHALL BE MIN 3,000 PSI, 28 DAY COMPRESSIVE STRENGTH. /�V� D; 7 4, WIND DESIGN PRESSURE: - 150 MPH ST. LUCIE COUNTY — CATEGORY II BUILDING DIVISION } — EXPOSURE C. REVIEW FOR C I NC13 REVIEWED BY, DATE 1 [i Vr 4 1)" GENERAL NOTES: 1, BRONZE POWDER COATED FINISH. PLANS ANO PF.RMIP - MUST BE KEPT ON JOB C%G NO INSPECTION WILL BE" NOV 0 7 2019 2z'x22"X0,125" ALUM, POST j'xj"x0,062' ALUM, PICKET $' J—BOLT THRU GATE FRAME WELD TO POST ��pIRR0 r T w�T S;RSE 0 S801ONP01%`��,