Loading...
HomeMy WebLinkAboutPLANSf8851 itTWaterstone Builders LLC This play equipment is Drawn By. Total Play Components 6 recommended for Sandra Nance Elevated Pla Blvd children ages: Scale: 1/4" = 1'-0" y Components 6 User Capacity FL 34951 5-12 This drawing can be Date: V Elevated Play Components Accessible by Ramp 0 Req. 0 20-30 scaled only when in 8/28/2019 Elevated Components Accessible by Transfer 6 Req. 3 Critical Fall Height Minimum Area Required: an 11" x 17" format Quote Number. 405 Golfway West Drive, Suite 302 BYO Recreation 6 05 7 — P P 33'-1" x 26'-6" 675-121941 Saint Augustine, FL. 32095 Accessible Ground Level Components Shown 2 Req. 2 V-0" 1-80043535316/w .byoplayground.wrn Different Types of Ground Level Components 2 Req. 2 DUIPMraft Arrows at deck comers indicate orientation of I PLAY SYSTEMS io each upright. See upright label detail. ORDER NUMBER: 88976 g CE"(Duramax use only) RECEIVE® 33'-1 " Structural Engineering, Inc. �— 10' — 45" Spencer N. Robinson, P.E. NOV 2 6 2019 8 Florida Lic. #81250 ST. Lucie County, Permitting 921 Shadow Drive, Suite 3 Lakeland, Florida 33809 TRIANGLE (863) 815-9541 TRANSFER POINT W\HANDHOLD 62349 RETURN'STEP 615 SQ FT Sc' 62345 MINIMUM REVIEWED FOR CNN 1 1 —913 SURFACINGREVIEWED St t er FQ 1 6 ENHANCED ENHANCED CODE COMPLIANCE 11%c Unt oO U BARRIER 6 RIER BARRIER 6 RIER ST. LUCIE COUNTY o Y (B.Y.O.) o� 1'4 U DRUM LINE RATTLE & RING BOCC (BELOW) SQUARE DISCOVROOF o o BPANEL,,`, R 63791 `1� "rtrrrr'�o,,,, 68501 69101 E %VS' L �'. g' E .tPo No 250 �• y 26'-6" MAXCLIMB 3.4.. 5,4„ 6,0„ ASCEND 4'8" 62253 '� & of '�� _ , � •.. 4 P .: 4:e BUBBLE PANEL AIN''��� •,S70 .HALE ,,` N�'�`� WHEEL L �����fills"O 63954 63776 HURRICANE SPIRAL DECK TO SLIDE DECK STAIRS 62130MU (1'-4" RISE) 8" KICKPLATE NOTE. (;k 0 P, 69144 62015 APEX CLIMBING 8" KICKPLATE 1. DESIGN CONFORMS WITH 2O17 FLORIDA ATTACHMENT 62015 BUILDING CODE (BUILDING & ACCESSIBILITY) (BYO) SINGLE ENTRACE DESIGN, 6TH EDITION, CRITERIA FOR 160 MPH WIND FORCES PER ASCE/SEI 7-10 68526 69264 MINIMUM DESIGN LOADS FOR BUILDINGS & 69264 OTHER STRUCTURES. 2. RISK CATEGORY II 3. CHAPTER 30 COMPONENTS/CLADDING (C&C) 4. INTERNAL PRESSURE COEFFICIENT '0' OPEN 5. EXPOSURE 'B' 0 5 10 20 It is the manufacturers opinion that the structure shown herein complies with current ads standards concerning accessibility If used with proper accessible surfacing and together with other necessary ground level play equipment. IMPORTANT: Never install play equipment over hard, unresilient surfaces such as asphalt, concrete, or compacted earth. It is the owner's responsibility to ensure the "minimum area required" contains an appropriate amount of resilient material to cushion accidental falls. L J r 't ' This play equipment is Total Play Components Watt Wat a Builders LLC Drawn By: v p a recommended for Sandra Nance B Elevated Play Components 6 User Capacity 8851 Waterstone Blvd children ages: Scale: 1/4" = 1'-0" i.♦ Fort Pierce, FL 34951 This Brewing can be Date: O Elevated Play Components Accessible by Ramp 0 Req. 0 20 30 5-12 scaled only when in 8/28/2019 405 Golfwa West Drive, Suite 302 Elevated Components Accessible by Transfer 6 Req. 3 Critical Fall Height an 11" x 17' format y Accessible Ground Level Components Shown 2 Req. 2 8'-01 Minimum Area Required: Quote Number: Saint Augustine, FL. 32095 BYO Recreation 6 057 - P P 33'-1" x 26'-6" 675-121941 1-800.653-5316Iw .byoplayground.wrn Different Types of Ground Level Components 2 Req. 2 IDV���w{{ Arrows at deck comers indicate orientation of ISO f�M'tiiili° Aeach upright. See upright Iabe1 detail. ORDER NUMBER: 88976 9 0 0 1 K AY SYSTEMS use (Duramax only) CERTIFIED 33'-1" Structural Engineering, Inc. f — 10 - 5» 48 Spencer N. Robinson, P.E. Florida Lie. #81250 921 Shadow Drive, Suite 3 Lakeland, Florida 33809 (863) 815-9541 615 SID FT G63311 MINIMUM 11 '-g13» SURFACING 16 G63308 REVIEWED FOR v° u CODE COMPLIANCE 001'411 0 G63310 63310 ST• LUCIE COUNTY G63310 BOCC G63311 `,,pp��f r4uq�i N.izE 60 •C) 26'-6" 3'4» 5'4.. 4'8" =Di .F r' O.•'•� �'�`� G63311�G6 3310 "-i.!ONAL EN`+`, G63308 UPRIGHT INFOR-MATe U 63311 UPRIGHT DESCRIPTION G63308 11' GENERIC DRILLED UPRIGHT G63309 12' GENERIC DRILLED UPRIGHT G63310 13' GENERIC DRILLED UPRIGHT G63311 14' GENERIC DRILLED UPRIGHT 0 5 10 20 It is the manufacturer's opinion that the structure shown herein complies with current ada standards concerning accessibility if used with proper accessible surfacing and together with other necessary ground level play equipment. IMPORTANT: Never install play equipment over hard, unresilient surfaces such as asphalt, concrete, or compacted earth. It is the owner's responsibilityto ensure the "minimum area required' contains an appropriate amount of resilient material to cushion accidental falls. L J r Waterstone Builders LLC 8851 Waterstone Blvd Fort Pierce, FL 34951 BYO Recreation DURAIM PLAY SYSTEMS Structural Engineering, Inc. Spencer N. Robinson, P.E. Florida Lic. #81250 921 Shadow Drive, Suite 3 Lakeland, Florida 33809 (863)815-9541 SHOCK ABSORBING PROPERTIES OF RESILIENT SURFACING MATERIALS VARY. IF YOU DETERMINE THAT LESS THAN 10" OF SURFACING IS REQUIRED. MAKE UP THE DIFFERENCE IN ELEVATION WITH EARTH BEFORE APPLYING SURFACING. IF MORE THAN 10" IS REQUIRED MAKE UP THE DIFFERENCE BY REDUCING THE DEPTH OF THE GROUND HOLE BY NO MORE THAN 2". EARTH VARIES REFER TO 6057—PP TYPICAL FOOTING RESILIENT SURFACE MATERIAL This play equipment is recommended for children ages: 5-12 Minimum Area Required: 33'-1" x 26'-6" �O Scale: 1/4" = 1'-0" This drawing can be scaled only when in an 11' x 17" format Drawn By: Sandra Nance Date: 8/28/2019 Quote Number. 675-121941 8O 013 7OA 12 5 B 9 OO 4 11 A XA A M15 N 18 O 23 10 A A 170 14 10"[25A cm] SURFACING 6O CONCRETE (3000 PSI) BRICK OR EQUIVALENT 405 Golfway West Drive, Suite 302 Saint Augustine, FL.32095 1-600-853-5316 /www.byoplaygmund.com 22 O 210 23 K A B 24 160190 N 11 Total Play Components Elevated Play Components Elevated Play Components Accessible by Ramp Elevated Components Accessible by Transfer Accessible Ground Level Components Shown Different Types of Ground Level Components 0 IRea.10 6 1 Req. 1 3 2 Req. 2 2 Req. 2 Arrows at deck comers indicate orien"' n of each upright. See upright label detail. ORDER NUMBER: 88976 (Duramax use only) User Capacity 20-30 Critical Fall Height 8'-0" FOOTINGS ORDINATE TABLE HOLE X Y DIAG 1 —3'-3" —2'-3 1/2" 3'—l1 1/2" 2 —4 1/2" —3'-0 1/2" 3'-1" 3 0" —3' 3' 4J42 0" 0" 5" 2'-3" 2'-3 1/2" 6 —7'-5" 7'-6 1/2" 7" 3'-6" 82" 5'-4 1/2" 5'-9 1/2" 92" 2'-3" 3'-5 1/2" 10-3' 4'-3" 110" 3' 12" 2'-8" 4'-8" 13" 4'-11" 6'-3" 14 —3' 5'-2 1/2" 15 4'-3" 0" 4'-3" 16 6' —7'-4 1/2" 9'-6" 17 7'-3" —3' 7'-10" 18 7'-3" 0" 7'-3" 19 8'-2" —7'-4 1/2" 11' 20 8'-9" 2'-7" 9'-1 1/2" 21 9'-10" —l'-6" 9'-11 1/2" 22 1 11'-4" 1'-1" 11'-5" 23 14'-5 1/2" —l'-3" 14'-6" 24 15'-7 1/2" —3'-1 1/2" 15'-11" k a i FOOTINGS TABL TYPE DIAMETER/SIDE DEPTH QTY. A 1'-6" 45.72cm 1'-8" 50.8cm 12 B 1'-2" 35.56cm 1'-8" [50.8cm] 11 K 3'-0" 91.44cm 1'-8" r50.8cmnl 1 FOOTING TABLE I VARIES I KhV1hVVII=U f]'"ur t REFER TO GROUND PLAN CODE COMPLIANCE It is the manufacturer's opinion that the structure shown herein complies with current ads standards concerning accessibility' If used with proper accessible surfacing and togetherwith other necessary ground level play equipment. ST. LU CI E COUNTY IMPORTANT: Never install play equipment over hard, unresilient surfaces such as asphalt, concrete, or compacted earth. It is the owner's responsibility to ensure the 'minimum area required" contains an appropdate amount of resilient material to cushion accidental falls. BOCC I `.... EASEuwT I£R p .BC 2W. PA. 105 I 1 � 16p' iLOPIOa vpMFA s Ilbli Cp. EA3]I0Ii PFA QR.Bptl( 2W. PA(£ 12N 1 I W1IFASTW E - PH pNE PLaT BOW 5 PepES ]5-47 LEGAL DESCRIPTION: (BY CLIENT) NOV 2 B 2O? g.= PARCEL R-1, WATERSTONE - PHASE ONE, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 52, PAGES 35-47, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. cue County, Per( $� Uwl NR _,mv Vml - l,w1 . Euu.(uMl -xxm (�sm7IF Y -fwrme..0 �'Wnm f - NKl¢rt m'. Srtm os (•-.ona�Fu e m Y - � - •cnnY 4_________ a o aJMlo E� g Ntlpw Rb129 A+4'SR] TW✓16T SR=54 W�a� 50 39 LNE�.Yfi - _ 5 63.; 4 6p� Cpp lvos.rms SS r wmini�,ac� Q3 _ __ _ m qA 4 qb OAi4Pti� 5 Ad q8 `.: T nyA Klmm 'renmwc oR PfAWNG q � 1pN^' IF D� q„ q IN BAIXRB.VL CW T 'Y 8 q Kg_ ,N g ARq Im €L a pgRq SS ..q 1 tee 21,77 44 N I sl q° f q ex�s — yl �uN Aq I � S P .yt 1 m'°' vao ai 9 aV' ranNmH+.N A q n n�..,e:t 4S°" _ tf•^'-,U N MNa BSJ, IF q•.` WAT S.E - PH. WE PUT EM 52 PPGES JS-47 TRACT R-1 3.863 ACRES IE dICAEIE ', gip° '� d PK N1 I / I y \ J In^ N rvI� /ah GSi ��e�p• I J ` / /\\Y/// N 7j•2 0 W �- 77.41' pmL-12 IEXSiWE - I. 01 Z BWX 54 PAQ5 47 GRAPHIC SCALE (w veer ) 1 Lm.=m a MIN. SETBACK MI R sips 1 RFA _ HANDICAP RAMP DETAIL AQ st{¢Tt A4 U /SURVEWIS NOTE£ 1) I F/059 N RIGNIS-OF-WRY SHOWN XEREON EXCEPT AS L,(rLD FCR W ME PUT OMY "JWU `" S I .. IO iXE $UR✓EYOR iXE EUMflpR 1L15 NgOE NO SEYtLX OF R2 I'UOIC RFOR SWJI. 2. ONLMYY OOPEN PNO NOTORIOVS SIgWN EV,Nom FMS OF FA$ENqNO RIGYT-W-'MAY ME LOfA]ED Ni0 XEAEON wE SURhYOR W$ NOT LOG7FD /NY VNOERTFOUNO UilllilES OR FOUNhAipfG Wl1Gl INY ENLROICN. J. BURINGS XEREON ME REi£RREO M qN A6UNE0 VALVE OF J 8TA6Y0 E fOR IXE GW2RME OF'M' TERSIOVE BOVIEVAFD JNp bTARIHC 6 IMM/GL NRN SXE qAT OF REMR0. l TM1£ OF SURrFY. BOUNOA4Y S ARIOm INS OLOE OUMM lWw OZPWNNE. X AS 9M1MN 0.4 R000 dNSURWCE P97E IUP NNUVNT' N0. ]oad5. pgNEL 0070 . EUFFIX J. EiFEL7R.E M7E {E8LL4gY 16. ZOIZ A USE QKY PRGPWIY CORNERS Fqt CWd"IRUC1pN OF FPTIS AW � pwm wvRowuwra PROJECT NUMBER: SHEET: I OF 1 y N Eq D 00 1yy1CJJ11 � ^ =MM o F�rA N on N�v � M o z = IF a RECEIVED NOV 2 6 2019 ST. Lucie County, Permitting co J v 6 NSCANNED NOTES. BY St. Lucie County 1. All surface under and within 6 feet horizontally of the play equipment meets ASTM Slide Bedvray F1292-13. All Engineered Wood Fiber surfacing meets ASTM F2075-15. All Loose -Fill Rubber surfacing products meet ASTM F3012. — — ilin. -lirn. 1 Exit Height 4 Top of Safety Surfacing 2. All play structures and activities, unless noted otherwise, meet ASTM F1487-11. Finished Height of Al _r—� AI AOA Transfer Platform Height to Safety Surfacing 1 Safety Surfacing 3. Playground area is full, nmple i A8 ac. essible routes in accordance with Section 206.2.17 and - F-Forida Accessibili Code o Building Construction, except Slide elevation: >4gin. • Exit Height between Tin. - 11i tY g P <d8in:-Exit Height no greater than ilin. . as modified by 1008.2. Slide Exit Height to Safety Surfacing; 4. Playground Structures and Playground area are fully compliant with Sections 453.10.5.2 and 468.2.2 of Florida Building Code (Building) for Playgrounds and equipment. 5. Maximum Fall height from any point on any structure is no greater than 120 in. (10 ft) 1m;W'A+na9er,n,rYro:�nt4Ce atxirQee Qe:stiar above the top surface of the installed safety surfacing and does not exceed the fall attenua- w 13e4,104;*(t, *f c„tRerr,1 tion capacity of the chosen surface. as defined by ASTM standards. ; Top of Safety Surfacing 5 SafetYsvrladngthkicness Gradelevel 6. Surfacing material (Concrete, EWF, Rotational molded Plastic), used to construct ADA ac- cessible routes to and from the designated playground area are of materials as shown on Al Ai the plans, and have a slope no greater than 1:20. izin.M n.• Engineered wood fiber(Et9Fltnulch:9inmin. Loose fit) Rubber mulch: 6in min. • Top of: Safety Surfacing - 'Measured Wren Occupied b. Maximum Users 6o se fin safety.Surfi cing Minimum Thickness within the 7. Surfacing material (EWF, Loose Fill Rubber mulch, PIP, Bonded Rubber) used to construct Y ufetone accessible routes within the playground use zones are materials that meets minimum Belt Seat Height to Safety Surfacing thickness requirements or greater and comply with Advisory 302.. 8. ADA ramp shall be BYO model 20272-CW, or equivalent. Ramp is constructed of rotation- al molded plastic, commercial grade, and meets ASTM and CPSC standards and is certified by the International Play Equipment Manufacturers association (IPEMA) and is ADA compli- ant. r r r 9. ASTM certification is not required for the following play activity structures and associat- 3 6 ed items that do not include a play surface, a defined use zone, or a fall height requirement Al J Ai if shown on the site plan: • Tetherball .. za;n. Min. • Site Amenities (Benches, trash receptacles, dog waste stations, etc.) iop ofSafety Surfacing • plastic landscape borders 'Measured When occupied by Maximum Users Enclosed Bucket feat Height to Safety Surfacing 10. Unless otherwise directed by the licensed Engineer of record, all -installations comply with the provided manufacturer's installation instructions and follow the manufacturer's guidance for best practice installation procedures. wwur, BYOPlaygraund.mm NOTES 1. All surface under and within 6 feet horizontally of the play equipment meets ASTM Slide Bediway F1292-13. All Engineered Wood Fiber surfacing meets ASTM F2075-15. All Loose -Fill Rubber surfacing products meet ASTM F3012. q Exit Height 4 Top of Safety Surfacing 2. All play structures and activities, unless noted otherwise, meet ASTM F1487-11. Finished Height of Ai Ai ADA Transfer Platform Height to Safety Surfacing Safety Surfacing 3. Playground area is fully complete with ADA accessible routes in accordance with Section Slide elevation: 248in,-Exit Height between 7in.-15in. 206.2.17 and Chapter 4, 2014 Florida Accessibility Code for Building Construction, except <48im Exit Height no greater than Stin. as modified by 1008.2. Slide Exit Height to Safety. Surfacing 4. Playground Structures and Playground area are fully compliant with Sections 453.10.5.2 and 468.2.2 of Florida Building Code (Building) for Playgrounds and equipment. 5. Maximum Fall height from any point on any structure is no greater than 120 in. (10 ft) u+ssg��+w+mrtimms�rrotsctvdeewKttentsela above the top surface of the installed safety surfacing and does not exceed the fall attenua- tion capacity of the chosen surface. as defined by ASTM standards. Top of safety'Snrracing 2 ; 5 Safety surfacing thickness 6. Surfacing material (Concrete, EWF, Rotational molded Plastic), used to construct ADA ac- cessible routes to and from the designated playground area are of materials as shown on Ai Ai Grade min. Level the plans, and have a slope no greater than 1:20. t2m. Min.' Engineered Rubber%Nroonber- bin mutdraii min. Loose fill blSer mulch: bin min; -Top of Safety SuiladnZ - Loose fill Safety Surfacin; Minimum Thickness within the 'Measured When Occupied by Maximum Users 7. Surfacing material (EWF, Loose Fill Rubber mulch, PIP, Bonded Rubber) used to construct use zone accessible routes within the playground use zones are materials that meets minimum Beft Seat Height to Safety Surfacing thickness requirements or greater and comply with Advisory 302. 8. ADA ramp shall be BYO model 20272-CW, or equivalent. Ramp is constructed of rotation- al molded plastic, commercial grade, and meets ASTM and CPSC standards and is certified by the International Play Equipment Manufacturers association (IPEMA) and is ADA compli- ant. 3 9. ASTM, certification is not required for the following play activity structures and associat- g ed items that do not include a play surface, a defined use zone, or a fall height requirement Al Ai if shown on the site plan: • Tetherball x41n. Min." • Site Amenities (Benches, trash receptacles, dog waste stations, etc.) Top ofsafety surfacing • plastic landscape borders Measured y.'hen Occupied by Maximum Users Enclosed Bucket fiat Height to Safety Suifacinp 10. Unless otherwise directed by the licensed Engineer of record, all installations comply with the provided manufacturer's installation instructions and follow the manufacturer's guidance for best practice installation procedures. m w .BYOPlayground.co