HomeMy WebLinkAboutPLANGENERAL NOTES: !' 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION, ACI 318 (LATEST EDITION), NCMA, o. NATIONAL FOREST PRODUCT ASSOC., NOS, TPI (LATEST EDITION), AND ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF N WORK. 3. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. DESIGN PARAMETERS FOR LOAD COMPLIANCE 1. RISK CATEGORY: II 2. CODE REFERENCE: 2017 FLORIDA BUILDING CODE (6TH EDITION) & ASCE 7-10 3. STRUCTURE DESIGN: OPEN 4. GCpi: t0.00 5. WIDTH OF END ZONE: 6. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST 124 MPH (Vasd) 3-SECOND GUST *USED FOR ANLAYSIS' 7. WIND EXPOSURE: D 8. LOADS: 8.1. FLAT SURFACES: +1-55 PSF 8.2. RAILING/POST: 50 LB/FT OR 200 US (GREATER OF THE TWO) 9. SHEAR WALLS WERE CONSIDERED 10. A CONTINUOUS LOAD PATH WAS PROVIDED 11. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE. ALUMINUM NOTES 1. ALL FASTENERS TO BE 2024-T4 ALLOY, NON-MAGNETIC STAINLESS STEEL, OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH 5.1AC SPECIFICATIONS FORALUMINUM STRUCTURESSECTION 1, THE ALUMINUM ASSOC., INC. & APPLICABLE FEDERAL STATE & LOCAL CODES. 2. ALL MEMBERS SHALL BE AND HAVE BEEN DESIGNED USING ALUMINUM ALLOY 6064-T52 UNLESS NOTED OTHERWISE. 3. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS. 4. ALL WELDS TO USE MINIMUM OF 4043 FILLER (ALUM)/E70XX (UNLESS OTHERWISE NOTED). S. ALL WELDS ARE SUBJECT TO INSPECTION BY THE ENGINEER OF RECORD FOR THIS DESIGN, AND MUST CONFORM WITH THE AMERICAN WELDING SOCIETY (AWS) CURRENT CODES (D1.2) & PRACTICE. 5.1. ALL STRUCTURAL WELDS ARE TO BE 1W(UNLESS SPECIFIED OTHERWISE). 6. ALL ELECTRICAL GROUND AND RELATED WIRING, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 7. ALL ALUMINUM IS 6061-T6 MIN. SCOPE OF WORK: 1. INSTALL RAILINGS PER PLANS & SPECIFICATIONS ABOVE. *PLEASE CONTACT ENGINEER IF CHANGES ARE REQUIRED* w 'EMS" 428-53-215 TOP CAP RAILING V X 1- X 1/8" WALL ALUM. PICKETS 70-3/8" MAX. SPACING 8 G TMP 4" SPHERE UNABLE TO PASS THRU v NOTE: (2) GATES W/'MAGNA LATCHES' (59' ABOVE THE GROUND) & SELF -CLOSING HINGES (SEE PLAN FOR LOCATION) EXIST. CONC. SLAB 2" X 2" X 1/8' RAIL/POST ALUMINUM RAILING ELEVATION SCALE: 1/4" = T-0" SCANNED St LucBCounty 1/4'THKALUM. PLATE 2" X 2- X 1/8' WALL ALUM. TUBE 1/4' X 2-1/4-TAPCONS (4 PER POST) POST MOUNTING PLATE DETAIL SCALE: 3" =1' 0" RECEIVED —] �`— NOV z 7 _19 ST, wcle County, Permitting 1'/1 — VS i i ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR Cc P lIANCE REVIEWED BY DATE PLANS AND PER IT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE • um-oo-no HK WALL ALUM. TUBE \\\\,1111 � Q ALUM. PICKETS ' 5 $ AKALUM.TUBE 11/4' THKALUM. BASE 4-X 2-1/4' THK 4 GLASS RAILING SECTION SCALE: 1-112" = T-0" ru O$ V1 E V)m�`[ co PSI L ,_c M V 1 VM �zs Caa Go LL O US N� Se S-1