Loading...
HomeMy WebLinkAboutSOIL COMPACT TESTHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: �C1 t ENCINEEWjIG f;JiYi AND TESien6 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 January 22, 2020 1911-0031 Grande Construction 13400 Palmetto Village Bldg 10 Palm City, Florida / 1 II— Mailing c ! PO Box 78-1377 Sebastian, FL. 32978 Phone:772-589-0712 C.A.# 5693 KSMengineering.net I.f•'ldiofrJ-lfF 200298-9d/MH/jo ITEM TESTED. Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. N.W. 0"-12" 54 113.3 113.9 99.5% 2. Center 52 112.6 98.9% 3. S.E. 51 110:6 97.1% Soil Description: Brown Sand with traces 115.0 of Rock W l In Place Moisture: E I I I I I 9.6% I I—..—.�—..—�.—..—�.------ 114.0 I I I I Optimum Moisture: H I T113.0—.... —..— .•--I .•.•:--.•.• Max. Dry Density: P.C.F. P 1 113.9 @Test Locations The 112.0 —••—•4III — •—•IIIII •—••—I�II4I -11.0% Density & Penetrometer F Readings Indicate the I I I I — —I — — I ^t Degree of Compaction Meets D 111.0 — {— — l y Minimum Required R I I I I I for Staked Foundation Y 110.0—..—.;—..—;.—..—�.—.. I I I I �..—..T..—..; I 8 9 10 11 12 13 14 Rqsoe%ui& _'zC(tf9d% %% ......... •�,�GEN$E••,• ,9 % Moisture - % of Dry Weight r� E Disclaimer: Contractor is responsible to maintain p' the tested area in the condition that KSM completed the indicated passed compaction test. ful ter C9 KSM is not responsible if the tested area has been reBf .. altered from the approved inspected condition. E # 68366 1/23/2020 Email to: greg@grandefl.com Proudly Serving Florida since 1990