Loading...
HomeMy WebLinkAboutSOIL COMPAC TESTHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: 401 t ENGINES CmPiYlAND TESTING SOIL COMPACTION REPORT ASTM D 1SS7 and ASTM D 2922 January 22, 2020 1911-0033 Grande Construction 13400 Palmetto Village Bldg 9 Palm City, Florida SCRNNED By St, Lucie County L �� [—c�� Mailing I PO [3ox 78-1377 Sebastian, FL. 32978 Phone:772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB M 200298-8d/MH/jo ITEM TESTED: Compacted Foundation Fill TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. N.W. 0" -12" 51 113.3 113.9 99.5% 2. Center 50 111.4 97.8% 3. S.E. 53 113.7 99.8% Soil Description: Brown Sand with.traces 115.0 of Rock W In Place Moisture: E I I I I I I Optimum Moisture: H I 11.0% T I I I I I 113.0 j—..—.J—..— —..4_.. .—..1..—..: Max. Dry Density: P.C.F. P I I I I I 113.9 I I I I I C I @ Test Locations The 112.0—••—•I— •—•I•—••—G•—••�••— ! ••—••• Density & Penetrometer F I I I I Readings Indicate the 111.0 I I I I f Degree of Compaction Meets D Minimum Required R I I I I I for Staked Foundation Y I I f I I 8 9 10 11 12 13 14 RespectfyllN 6ubr6i jted: S. •.• �\ �,,,....,,� (� •., • .Q 4 Moisture -% of Dry Weight Disclaimer: Contractor is responsible to maintain ' the tested area in the condition that KSM • ` T ,� completed the indicated passed compaction test. ALI��`� KSM is not responsible if the tested area has been •• • �"""�C�G •`�• altered from the approved inspected condition. r �NAt- PE # �i$i 6ll. „r.• 1/23/2020 Email to: greg@grandefl.com Proudly Serving Florida since 1990