HomeMy WebLinkAboutPROJECT INFORMATIONunITED REFRIGERAI in Inc. 1flA/KIN COMFORT FOR LIFE 7 SERIES WALL MOUNT wifications Model )oling Capacity 17 Series Wall Mount Indoor Specifications FT*B09AXVJU FT*B12AXV1U FT*B18AXUJU 8,8000 11,000 18,000 FT*624AXVJU 21,200 eating Capacity 9,400 11,300 17,900 21,200 oisture Removal Gallons/Hour rFlow Wet 378/345/272/215/165 392/358/282/232/165 578/529/471/1418/374 703/654/585/507/437 rFlow Dry 378/345/272/215/165 392/358/282/232/165 578/529/471/418/374 703/654/585/507/437 )und Pressure Cooling 41/40/34/29/21 42/41/34/30/22 44/40/38/35/32 46/43/41/37/33 )und Pressure Heating 41/40/34/29/21 1 42/41/34/30/22 44/40/38/35/32 46/43/41/37/33 imensions 1111/16 x 35 1/16 x 81/4 12 5/8 x 461/8 x 91/2 !eight 20lb 1 30lb 17 Series Outdoor Specifications R*B12AXVJU R*B18AXVJU R*B24AXVJU Cooling 46 51 51 e Heating 46ge =Modelodel Cooling ge Heating urrent Protection15A 50 -115 Degrees F 5 - 64 Degrees F 20A 721518 )imensions 2515/16 x 10 3/4 2511/16 x 3311/16 x 1215/16 Veight 53lb 57lb 82lb 97lb Accessories JL16x36 Condenser Pad 3R440 Wall Bracket (85003 Condensate Pump 09-18 (87721 Condensate Pump 24+ n8016 Pump Enclosure X95003 Parts & Labor Plan EWDKEC1OPL Transferrable Extended Service Plan EWDEI10PL 6-10 Year Parts;10 Year Labor' abor See more installation supplies & accessories starting on page 61. SCq St �Ur By�FO e Couhy 12 Specifications are subject to change at anytime. United Refrigeration is not responsible for changes, errors & omissions. GINITED REFRIGERATION INC. 17 SERIES WALL MOUNT Residential COMFORT • Titanium Apatite air purifier • Hot Start & Auto Changeover (Heat Pump) • Vertical Louver Auto Swing • Powerful Mode • Automatic Fan Speed • Dry Mode • Quiet Operation Indoor & Outdoor unit ova t�. w-•. Residential Applications } ;}• r Iry Timely registration is required in most states. 1''I li��lf Refer to page 6 for details Indoor Outdoor FTKB09AXVJU RKB09AXVJU FTKB12AXVJU RKB12AXVJU FTKB18AXVJU RKB19AXVJU FTKB24AXVJU RKB24AXVJU DA/K/N COMFORT FOR LIFE ' 3 CONVENIENCE CY • Remote Control included • Night Set -Back • Self -Diagnostic Control • Auto Restart • Multi color LED Function Light • Precharged Outdoor Units (25'); Adjust Charge .21 oz/ft �i CERTIFIED° EFFICIEN • Inverter Technology • 24 Hour On/Off Timer) • Eco+ Mode DURABILITY-' • Anti -Corrosion Coating • Daikin Swing Compressor This model is M suitable for low ambient cooling applications -EER EERWHSPFdcopgtu/h Cooling Heating Btu/h Drain Line Set w/ 14/4 Wire*Length Max. Max. HeightL7.0 11.08,800 — D17.0 8.511,000 ----17.0 DH-16 MS1S1412144••-1/2 98' 32' 10.518,000 21,200 ---- DH-16 MSLS1458144••-1/2 98, 32' 17.0 11.0 -- --- FTX1309AXVJU RXB09AXVJU 17.0 11.0 93.56 8,800 9,400 DH 116 MSLS1438144••-1/2 65' 32' FTXB12AXVJU RXB12AXVJU 17.0 8.5 9 3.30 11,000 11,300 DH-16 MSLS1438144•• 1/2 65' 32' FTXB18AXVJU RXB18AXVJU 17.0 10.5 9 3.30 18,000 17, 000 DH-16 MSLS1412144••-1/2 98' 32' FTXB24AXVJU RXB24AXVJU 17.0 11.0 9 3.68 21,2D0 21,200 DH-16 MSL51458144••-1/2 98 65' ••Line Sets are available in 25' & 50' lengths (Example: MSLS143850-1/2+ 58340803). if metal clad wire is required, order your line set and wire separately f Recommended mounting plate retention spots (5 spots in all) LNSTALLATION PLATE 09112 sole on All dimensions are in Inch (mm) Dimension A # B C H I S !! B L M ;Model 3-/16 3[6t -11/16 dI6i-6 b' (153) (181) (707) 2-1116)51 514 2 (89p) (6a (297) (21 (104) (�) ( f Recommended mounting plate retention spots (7 spots in all) R INSTALLA17ON PLATE 1824 e wall hole 65mm) position All dimensions are in Inch (mm) Duaer�on s B' C i D E F G H I I J I% I L I M -a E F (64D g C 0 o 0 o Dimension A g C D E F G H I J K L M N 0 P Q Model 09112 21-Sf8 25-151161 2 17116 107z4 518 9f4701 (96) 3(93)6 3(94)6 (60) (14) (133) (8) 0 ) (2 9) r 0 0 0 0 0 All dimensions are in Inch (mm) Dimension C D E F G H I J K L M N 0 A E Model 18 3(gIl5)6 (628) 1(328)6 (520) (179) 1(46)6 (101) (113) 603) (126)6 �164) (IS) 1(34)6 1O (362) yl 33-1ll16 28- 1 z1;5116 21 20 I�� (�7g) I-�4�6 (101) (113) 603) (126)6 (164) (IS) 1(34)6 1(23) ( 62) Dimension P Q R S T Model 2 6 2-5/8 114 18 (13) (75) (8) (67) 0) yI 2-T18 2-15116 ,�, 5116 m 2-518 (fi71 114 (71 1-3 Air Conditioning & Heating Product Features • Internal factory -installed thermal expansion valves for cooling and heat pump applications • Direct drive, multi -speed ECM blower motor • All -aluminum evaporator coil • Coil mounting track for quick repositioning • Optimized for use with R-410A refrigerant • Cabinet air leakage less than 2.0% at 1.0 inch H2O when tested in accordance with ASHRAE standard 193 • Cabinet air leakage less than 1.4% at 0.5 inch H2O when tested in accordance with ASHRAE standard 193 • AHRI certified; EfL listed ASPT SERIES MULTI -POSITION, MULTI SPEED, ECM -BASED AIR HANDLER WITH INTERNAL TXV 1'2 To 5 TONS Contents Air Handler Nomenclature ....................2 Heater Kit Nomenclature ...................... 2 Product Specifications ...........................3 Dimensions ............................................ 4 Airflow Data ........................................... 6 Heat Kit Data .......................................... 8 Wiring Diagram....................................15 Accessories..........................................18 • Rigid SmartFrame'M cabinet • Horizontal or vertical configuration capabilities • 21" depth for easier attic access • DecaBDE-free thermoplastic drain pan with secondary drain connections • Screw -less sides and back helps to reduce condensation when installed in humid locations • Foil -faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grain -embossed finish • Glue -less cabinet insulation retention • Tool -less filter access • Field Installed 3 kW —25 kW electric heater kits available ir 1 O PARTS * _ L cosmumrmx <ouwxvvmx LIMITED c us puumsrssear vrvw<xumru.srsrsa easmxmar wrvpi. eexrwmeroxv<s YEAR WARRANTY' mWm a•twm In_tertek a Ivry IBM. • Umplete warrantydetei6 available fram your loral dealer ar at ..goodmanmfg.com. To receive the ll Year Parts Limped Wamroy, online registmdon must be completed within 0 days of installation. Online regirtmdan is not required in Ulilomia a mdwc SS-GASPT www.goc)dmanmfg.com 6/19 Supersedes 6/19 NOMENCLATURE ' A S 1 Brand A Single -piece Air Handler C Ceiling Mount PSC Motor D Downflow PSC Motor E Multi -Position Variable -Speed Motor R Multi -Position PSC Motor 5 Multi -Position EEM Motor W Wall Mount PSC Motor Cabinet Finish U Unpainted P Palmed N Uncased T Expansion Valve P T IS B 3 4 5,6 7 _ - HKS X 03 X A AA 1 2 3 4 Unit Type HKS Heat Kit for Air Handlers Circuit Breaker X No circuit breaker C Circuit Breaker Heating Capacity @ 240 Volts 03 3.0 kW 15 14.4 kW 05 4.5 kW 19 19.2 kW wth 150F limit 06 6.0 kW 20 19.2 kW with 170F limit 08 8.0 kW 25 25.0 kW 30 9.6 kW 5 4 AA 8 10 1 Engineering • Major/ Minor Revisions • Not used for Inventory management Refrigerant Charge 4 = R-410A Electrical 1 208/240 V,1 Phase, 60 Hz Cabinet Width B 17Y," C 21" D 24%" Nominal Capacity Range @ 235EER 25. 29, 33-2Tons 47-3Y, Tons 35.37-2S5 Tons 49-4 Tons 37, 39 — 3 Tons 59, 61— 5 Tons 6,7 Revisions Engineering Revisions Phase A :__1_ nL_.._ B Single Phase 240 V F Three Phase 208/240 V C Single Phase 208/240 V G Three Phase 460 V D Three Phase 208 V Cabinet Size (NIA) C C Cabinet D D Cabinet X AIICabinetSizes 2 www.goodmanmfg.com SS-GASPT PRODUCT SPECIFICATIONS NOMINAL RATINGS Cooling (Btu/h) 24,000 24,000 24,00 228,000 30,000 36,000 36,000 42,000 48,000 60,000 42,000 48,000 60,000 BLOWER Diameter 9'/," 9Y>" 30'/!' 9Yi' 9%" 10'%,, 10%' 10%" 105/a' 10%" 10'/a' Width 6" 6" 8" 5" 6" 8" 8" 10%" 8" 10%" 101W. 10%s' 10%." COIL CONNECTIONS Liquid W. W. 'YS' 'Y.' '/!' Ya' Y." IV '/.' W. W. Ya' W. Suction Y" Ya' �." s/e" Ya' Yo" Y.' W. %' %' Ya' Ys' Ya' Coil Drain Connect (FPT) y�ir Y., �ri Yid Yn 33/ri 3�r� 3�ri %rr K., 3�ir ELECTRICAL DATA Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity 5.8/5.8 5.8/5.8 4.9/4.9 5.6/5.6 5.6/5.6 5.6/5.6 4.9/4.9 4.9/4.9 7.1/7.1 7.9/7.9 5.6/5.6 8.6/8.6 8.6/8.6 Max. Overcurrent Device 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 (Amps) Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 253 253 253 1 253 253 253 Blower Motor Full Load Amps (FLA) 4.6 4.6 3.9 4.5 4.5 4.5 3.9 3.9 5.7 6.3 4.5 6.9 6.9 Horsepower (HP) Y '/. Y. Y. '/. % 'M '% '/. 1 Y. 1 1 SHIP WEIGHT (Liss.) 116 129 118 1 129 129 1 144 118 144 1 125 144 155 167 167 •Airflow rate @.3 static Note: Assumes dry coil; SUM correction for wet coil = 4%(208V / 240V) SS-GASPT www.goodmanmfg.com . . 1 DIMENSIONS 3.06' (7.62 cm) bS (4.13 pn) 1.45 (3.68 un) 21• 4.5 9.21' (11.4m 7.5' (19.1 cm) 2.93 '�� 5.2' un) (13.3 m) 0 3.1' (7.9 cm) 11.3' (26.70 cm)� DRAIN PORT DETAIL B 1.4• 55• .SS 55' (3.6 cm) (1.40 cm) (1.40 cm) (1.40 cm) PLASTIC 1.8' BREAKER (4.6 m) COVER LOGO LOCATION 2.1T (5.5l..) SUCTION TUBE A LIQUID LIN INLET G TUBE SEE DRAIN PORT DETAIL D H L 19.5' (49.5.) 1.73' -F 1.73' 1' 1.551 (4.39 cm) INLET (4.39 cm) (2.54 an) INLET (1.40 cm) (FRONT VIEW) (RIGHT SIDE VIEW) ASFi25B14• 45 16% 17% I 15Y 12 14 9 123/. ASPT29B14' 53% 16% 17Y. 23% 20A 14 9 7% ASPT33C14' 49 19Y 21 1791" 14% 17% 109/16 12% ASPT35B14" 45 16% 17Ya 15Y 12 14 9 123/< ASPT37B14" 53% 16'% 17% - 233/e 20% 14 9 7% ASPT37C14• 53% 19Ye 21 2113/,c 28% 17Y. 107/a 6Ye ASPT39C14` 49 19Ya 21 179/16 14% 17% 109/16 12Y2 ASPT47C14" 53% 19Ye 21 2113/i6 18% 17Y. 101/. 6Ye ASPT47D14• 53% 233/e 24% 21Y. 185/16 21 12% 67/e ASPT49C14• 49 19Ye 21 17°/16 14% 17A 10°/36 12% ASPT49D14' 58 233/e 24Ya 26Ya 22% 21 12% 13'/. ASPT59C14` 53% 19Ye 21 2113/16 18% 17Y2 101/e 6Ye ASPT61D14' 58 23% 24% 26Ye 22Ya 21 12% 131/. 4 www.goodmanmfg.com SS-GASPT DIMENSIONS (CONT.) SEE Daan low 1 WI W (28." vn) (1z ) i(t.C3 Pn) 4112' (11.93 an) 1 vey4.t3an)� HOR20NTAL DMM PO( DETNL 3111W (713an) � 2 IWIW p.41 flan) � i VEHTIG1LDMNPCWDt NL SS-GASPT www.goodmanmfg.com S •� Air Conditioning&Heating COOLING CAPACITY: 18,000 - 60,000 BTU/H SCANNED BY St. Lucie County GSX14 ENERGY -EFFICIENT SPLIT SYSTEM AIR CONDITIONER UP To 15 SEER & 12.5 EER Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data.........................5 Performance Data ............................... 29 Wiring Diagrams.................................33 Dimensions .......................................... 34 Accessories .......................................... 34 Standard Features Cabinet Features • Energy -efficient compressor • Heavy -gauge galvanized -steel cabinet • Single -speed condenser fan motor with a louvered sound control top • Factory -installed filter drier • Attractive Architectural Gray powder -paint • Copper tube/aluminum fin coil finish with 500-hour salt -spray approval • Service valves with sweat connections • Steel louver coil guard and easy -access gauge ports • Top and side maintenance access • Contactor with lug connection • Single -panel access to controls with space • Ground lug connection provided for field -installed accessories • AHRI Certified; ETL Listed • When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurri- cane -type winds (Anchor bracket kits available.) O PARTS I . EIV LIMITED mmranwms cosvaxvwlm °•au^°��r a°TM°"°rwtusrsma j CEXIIfltn BY 0Ne4L EEFfIflED aY DNV W. YEAR waggnxiv{ Intertex aoeoor=-rsosemr= i ,� • Completewarrantydetails available Fmmyourloral dealeroratwwwgoodmanmfgcom.Ta receive IB the lUVeat Pans limited Warranty, Online regisvaton must be completed within M days Of em installation. Online registmdon Is not reouired in California or Quebec. SS-GSX14 www.goodmanmfg.com /11y 5upersedes6/" NOMENCLATURE G S X 14 036 1 AA 1 2 3 4,6 6,7,8 9 10,11 Brand G Goodman® Brand S Split System Unit Type X Condenser R-410A Z Heat Pump R-410A Efficiency 13 13SEER 14 14 SEER 16 16SEER 18 18 SEER Engineering' Major &Minor revisions • Not uud for iry ntory oontml. Electrical 1- 208/230 V, 1 Phase, 60 Hz 018-1%tons 030-236 tons 042 3YTons 019-VA tons 031-2%tons 043 3%Tons 024-2 tons 036-3 tons 048 4Tons 025- 2 tons 037- 3 tons 060 5 Tons 2 www.goodmanmfg.com SS-GSX14 PRODUCT SPECIFICATIONS GSX14 r: r r r 0301 r CAPACITIES Max Cooling (BTU/h) 18,000 18,000 24,000 24,000 30,000 30,000 SEER/EER 14/11.5 14/12.2 14/12 14/12.2 14/12.0 14/12.2 Decibels 75 71 74 71 74 72 COMPRESSOR RLA 6.0 9.0 7.7 13.5 12.8 12.8 LRA 37.5 47.5 38.0 58.3 64 67.8 CONDENSER FAN MOTOR Hp 1/8 1/8 1/8 1/8 1/6 1/6 FLA 0.65 0.7 0.7 1 0.7 0.95 0.95 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) W. fie" W. '�• '�•' W, Suction Line Size ("O.D.) Refrigerant Connection Size Liquid Valve Size ("O.D.) a/" %s' �s' W 'W, W. Suction Valve Size ("O.D.) a 3 'a/°" '�" Y., W, Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Charge 68 68 72 75 80 90 Included piston: 0.051 0.053 0.057 0.057 0.065 0.063 ELECTRICAL DATA Voltage-Phase(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity 4 8.2 12 10.3 17.6 17.0 17.0 Max. Overcurrent Protection a 15 amps 20amps 15 amps 30 amps 25 amps 25 amps Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Conduit Y211 or'/°" W" or 'h" or'/<" "or'/." %I Or'a/°" %:" or'/." EQUIPMENT WEIGHT 102 131 126 136 162 162 SHIPPING WEIGHT 117 146 141 153 180 180 ' Line sizes denoted for 251me sets, tested and rated in accordance with AHRI Standard 2101240. For other line -set lengths or sizes, refer to the installation & Operating instructions and/or the long line -set guidelines. ' Installer will need to supply''/•" to W adapters for suction line connections. ' Installer will need to supply''/." to 1W adapters for suction line connections. ° Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ' Must use dme-delay fuses or HACK -type circuit breakers of the same size as noted. Narrs • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15'of W liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. SS-GSX14 wwwgoodmanmfg.com PRODUCT SPECIFICATIONS (CONT.) r r I. t, 048 I.r CAPACITIES Nom Cool (BTU/h) 36,000 36,000 42,000 42,000 487,000 60,000 SEER/EER 14/12 14/12.2 14/12 14/12.2 14/11.7 Decibels 73 73 73 73 75 COMPRESSOR RLA 14.1 14.1 16.7 16.7 19.9 25.0 LRA 77 72.2 79 79 109 134 CONDENSER FAN MOTOR Hp 1/6 1/6 1/6 1/6 1/4 1/4 FLA 0.95 0.95 0.95 0.95 1.3 1.3 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) W. W. W W. W. %" Suction Line Size ("O.D.) %" 1%" 1'/e" SY:' 114" Refrigerant Connection Size Liquid Valve Size("O.D.) %" %s" %" W. '31°1 W. Suction Valve Size ("O.D.) %x° y %" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Charge 81 81 93 93 101 120 Included piston: 0.068 0.071 0.074 0.074 0.078 0.088 ELECTRICAL DATA Voltage -Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity 4 18.6 18.6 21.8 21.8 26.2 32.6 Max. Overcurrent Protection s 30 amps 30 amps 35 amps 35 amps 45 amps 50 amps Min/Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Conduit z or W x" or'/," '/:" or'�" Y" or'/." y" or'�" W or 1/4" EQUIPMENT WEIGHT 162 162 189 189 220 260 SHIPPING WEIGHT 180 180 207 207 242 280 Line sizes denoted for 25' line sets, tested and rated in accordancewith AMR[ Standard 210/240. For other line -set lengths or sizes, refer to the installation & Operating instructions and/or the long line -set guidelines. ' Installer will need to supply %"to'/." adapters for suction line connections. ' Installer will need to supply X"to1'h' adapters for suction line connections. ' Wire size should be determined In accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ' Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. Naas • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15'of Wliquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. www.goodmanmfg.com SS-GSX14