Loading...
HomeMy WebLinkAboutFL ENERGY EFFICIENCY CODE' iDepartment od' COf(ATIUn.i.t)' Afiai.r5 SN: 5550 ,. FLORIDA FNKR,Y OFFACIENC'1' CODE FOR LIUTt DING CON4TRUCTTUH FORM 60OA-93 1F2?si' entStil- componput Prescriptive Method A CENTRAL RROJECT NAME: K.OLTER TgOME5 TU41_DER: M.J FERRITER CON:-IRUCTTON AND ADDRESS: TOWNHORES MODEL #D ;PERMITTING ;CLrMAIE PORT :11 1_UICF FL_ 3m9lUFF[CF: ;ZONE: 41_.1 T?i.._i 61_1'' OWNER, WERMIT NO. !JUR1:iDrCTION NO. CK 1. New construction or addition 1. New Construction 2. Single family detached or Multifamily attached z. Multi -Family 3. If Multifamily -No. of units '3. 0 4. 1f Multifamily, is this a worst. case (yes/no) 4. No 5. Conditioned floor area (sq.ft..) 5. 1554.00 6. Predominant eave overhang (ft.) 6. 1.00 7. Porch overhang .length (ft.) 7. 8.00 S. Glass area and type: Single Pane Double Pane a. Clear Glass 8a_. O.Osgft O.Oosgft b. Tint, fi.l,m or -solar screen 8b.188.Osgft O.00sgft 9: Floor type and insulation: a. Slab on parade (R-value, perimeter) 9a.R= 0.00 , 149.00 ft 10.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) 10a-1 R= 4.20, 24S6.00sgft__._-..._ a. Adjacent: 2. Wood frame (insulation R-value) .lOa-2 R=11.00, 160.00sgft_-_,__ 11.Ceiling type area and insulation: a. Under attic (insulation R-value) 1 "La .R=1 %00 , 1650.0Osgft._...__._ 12.Air distribution syitems a.. Ducts (Insulation 1 L-ocation) 12a. R= 6.50 uncond 13.Coo.l.ina system SCANNED 1-3• type: Cent.r-;II A/(. _ BY SEER: 10.00 14.Heating System: St. Lucie County 14. Type- H. at. Pump --_--- I iSPF : 7.00 -- 15.Hot water system: 15. lypo: Electric FF: 0.90 1:6.Hot Water Credits: (HR-Heat Recovery, 16. - - DHP-Dedicated Heat Pump) -- 17.1nfiltration practice: .1, 2 or 3 17. 2 18.HVAC Credits (CF-Ceili.ng Fan, CV -Cross vent., 18. HF-Whole house fan, RB--Att,ic radiant. barrier, MZ--Mult.izone) 19.EPI. (must not. exceed 100 points) 19. n3.60 a. Total As_Built. points 1.9a. 28347.11 b. Total Base points 19b. 33908.42 ------------------------- I Hereby certify that the specifications covered by laticn are in compliance Florida Energy Code. PREPARED ER'i :,_-._-----._...._ DATE: �_..- - ------ - 1 hereby certify that this building is in compliance with the Florida Fnergy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: SUMMER CALCULATIONS BASE AS-BUTLT GLASS ---------------- ORIEN AREA x BSPM POINTS I TYPE SC ORTEN AREA x SPM x SOF POINTS --------------------------------------------------------- i --------------------- N 54.00 82.2 4438.8 SGL TINT N 04.0 51.6 .72 1994.6 E 40.00 82.2 3288.0 SGL TINT E 40.0 107.1 26 11130 S 94.00 82.2 7726.3 SGK TINT S 64.0 98.3 .25 1572.8 SGL TINT S 30.0 98.3 .45 1221.2 ------------------------- -------------------- L -------------- L ----------------- .15'x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS i GLASS AREA AREA FACTOR POINTS POINTS ------ POINTS --7 ---------------------------------------------------------------------- ;15' 1,554.00 188.00 1.240 15,453.60 19,160.82 6,007.43 NON GLASS------------ _---__ AREA x BSPM = POINTS TYPE R-VALUE AREA x SPM = POINTS ------------- I ----------------------------------------------------------------- WALLS---------------- Ext 2456.0 1.0 2456.0 Ext NormWtBlock In 4.2 24S6.0 1.16 2849.0 Adi 160.0 .7 112.0 Adi Wood Frame 11.0 160.0 .70 112.0 DOORS ---------------- Ext 24.0 4.8 115.2 Ext Wood 24.0 7.20 172.8 Adi 22.4 1.6 35.8 Adi Wood 22.4 2.40 53.8 CEILINGS ------------- UA 1554.0 .6 932.4 Under Attic 19-0 1650.6 1.10 IBIS&) Sib 109.0 -31.8-4738.2 i SJab-on-Grade .0 149.0 -31.90 -4753-1 I NF I L I RAT1 ON ---------- 1554.0 10.9 16938.6 Practice 12 1554.0 10.90 16938.6 TOTAL SUMMER POINTS 3S,012.66 23,195.45 TOTAL x SYSTEM COOLING TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT POINTS COMPON RATIO MULT MULT MULT POINTS 3S,012.66 .37 12,954.68 1 23,195.45 1.00 1.063 .340 1.000 8,382.17 **31..:isY::i=X::*:isY,%K:i::K:t::KA:=K:Y•:Y.:k;K%K:Y.;K:Y.W-:isY�:K%Y.-X%Y•:K:Y.%K:k:k%isY::k*:K-K=I::K:Y.*W.:K:K:K:i:k:1::V:*%1: M:K:k WINTER CALCULATIONS :K:k*****:K**:K*:K*****i****Av***********:t**A:*****:t*A:*****:K*********:k****.*:i�****:K****** BASE _-_ i =_= AS -BUILT GLASS-------------- ORIEN AREA x BWPM = --------------------------------------------------------------------------------- POINTS i TYPE SC ORIE.N AREA x WPM x WOF = POINTS N 54.00 -3.4 -183.6 ; SGL TINT N 54.0 9.6 1.18 612.1 E 40.00 -3.4 -136.0 SGL TINT F_ 40-0 -2.0 --S,04 403.2 S 94.00 -3.4 -319.6 ; SGL TINT S 64.0 -10.2 -1.`09 711.6 SGL TINT S 30.0 -10.2 .12 -37.2 --------------------------------•------------------ .15 x COND. FLOOR / TOTAL GLASS --------------------------- = ADJ. x GLASS = AD.I GLASS ; GLASS AREA ----.------------------------ AREA ---------------------------------------------------- FACTOR POINTS POINTS ; POINTS .15 1,554.00, 188.00 1,240-639.-'0-792.54 1,689.65 NUNAREA x BWPM = POINTS IYPE R-VALUE AREA x WPM --------------------------------- = POINTS WALLS---------------- Ext 2456.0 1.1 2701.6 ; Ext NormWt.Block In 4.2 2456.0 3.26 8006.6 Adj 160.0 1.8 288.0 Adj Wood Frame 11.0 160.0 1.80 288.0 DOORS------- Ext24.0 Adj 22.4 CEILINGS--- UA 1554.0 5.1 122.4 4.0 89.6 6 932.4 FLOORS --------------- Slb 149.0 -1.9 -283.1 INFILPRATION ---------- r Ext Wood 24.0 7.60 182.4 Adj Wood 22.4 5.90 132.2 Under Attic 19.0 1650.0 1.00 1650.0 Slab -on -Grade .0 149.0 2.50 372.5 1554.0 4.1, 6371.4 ; Practice 412 1554.0 4.10 6371.4 TOTAL WINTER POINTS 9,429.76 18.692,67 TOTAL x SYSIF.M - HEATING I'OTAL x CAP x DU(;T x S'YSIFM x C:RFDI'1 = HEATING WIN PiS MUL1 -­------------------- POINTS ; COMPON RATIO MOLT -------- ...---------------------`------- MUL'I MUL'I- POINTS 9,429.76 1.10 10,372.74 : 18,692,6/ 1.00 1.063 .484 1.000 ;,615.94 ENERGY GUIDE For detailed intormat.i.on of the EPI raL.i.ng numbem or for any 11EH listed, ask your Builder for LPI= 83.6 DCA Form 600A-93 or Form 600E:3-93 0 JO 40 30 40 50 60 70 80 90 1.00 ---_---"------------------------ '-X-------' The maximum allowable EPI is 1.00. The lower the EPI the more effic:i.ent the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS ..................... Single Tint INSULATION .................. Ceiling Fc-Value......... 19.0 Wall R-Value.......... 4.6 Floor R-Value...... ... 0.0 AIR CONDITIONLR............. SEER/EER.................. 10.0 SINGL CLR DBL TINT ------ X--------- ------ i. R-10 R-30 k-0 R-7 ' - ---- R-0 R-19 X--------------------' 10.0 SEER 17.0 X----'...--'-----"---'---. �.7 EER 16.0 HEATING FYSTE111.............. 6.8 HSPF 12.0 Electric COP/HSPF..,...... 7.O ;X -------------•------ 0.78 AFUE. 0.90 Gas AFUE.... ........ 0.00------- — ------------ WATER HEATER ................ Electric EF.— ........... 0.90 Gas EF.............. 0.00 Solar- EF.............. OTHER FEATURES .............. 0.88 0.96 - : ------X----------------' 0.54 0.90 0.40 0.80 ---------------------' I certify that these energy sa.vina•features required for the Florida Energy Code have been installed .in this house. Builder Address : _ _ ..... _.... _ .----- Ua to : Florida Energy Code for F3ui1ding Construction - 1993 Florida Department of Community Aftairs FL-EPL CARD93 WAI'EIR HEATING BASE AS -BUILT NUM OF x MULI = TOTAL -rAll1K VOLUME EF TANK x MULT x CREDIT = TOTAL BEDRMS RATIO MULT ------------- ------ ---------------------- --------------------------------------- 3 3527.0 10,581.00 so .90 1-000 3449.7 1.00 10,349.00 SUMMARY BASE AS -BUILT ------------------------ COOLING HEATING HOT WATER TOTAL COOLING HEATING HOT WATER TOTAL POINTS k POI;NTS POINTS = POINTS i POINTS POINTS + POINTS = POINTS ------------------ ---------------------------------------------------------------- 12954.7 10372.7 10581.0 33,908.42 83811.2 9615.9 10340.0 28.347.11 F p 1 = 83.1-,0 oei3al'tlrit+nt. 'of Community Affai"rs SN: 5550 FLORIDA EhtEla::;Y I_FFii;1ENC'i CORE FOR BUILDING CONSTRUCTION ' moral 6600ri-'la P.esi.ritantial:Con'ipoiient.. pres,c'riptive Method A NTRA1. ,Nft.)ta:l' IIAME:. KCJLTER HOMES 1BUILDLe: M.J FERRITER CONSTRUCTION AND ADDRESS: TOWNHOME:i 1,10DEL #E :PF-RMITTING !CLIMATE PORT ST I.IJICF FL 34910FFICF-; !'ZONE: 41_! 51_1 61._ - OWNER, lPERM� NO. :JURISDICTI'ON NO. GK l_ New consLruction or addition 1. New Construction -.2. r,irigle family detached or Multifamily attached _ 2. Multi. -Family - 3. 1 F Multifamily -No. of units 3. 0 �. If I•tul.t.ifamily, is this a worst. case (yes/no) 4. No 5. Conditioned floor area (sq.ft.) 5. 1530.00 6. Predominant eave ovt-.-rhang (ft.) ti. 1 .oU 7. Porch overhang length (ft.) 7. 6.00 _ B. Glass area and type. 5i.nctl.e Pane Double Pane - - a. Clear Glass 8a. 0.Osgft 0.00sgft. b. Tint, 1-itin or solar screen 8b.179.Osgft. O.00sgft. 9. Floor type and insulation: a. Slab on grade ( ,-va lt.tu , perimeter) 9a . R= 0.00 , 194.00 fit. 10.Net Wall. type area and insulation: a. Lxteri.or: l.. Concrete (Insulation R-value) 10a-1 R= 4.20, 1532.00sgft--_,_.__ a. Adjacent; 2. Wood frame (Insulation R-va.lue) 10a-2 R=11.00, 291.00sgft_._-_. 11.Cei.ling type area and insulation: a. Under attic (Insulation R-value) 11a.R=19.00 , 1650.00sgft.-.._. 12.Air distribution systems a. Ducts (Insulation + Location) 12a. R= 6.50 uncond 13.Cooling system SCANNED _ 13. Type: Central A/C _._._. SEER: 10.00 14 . Heat i ng System: St. Luc e County 14. Type: Heat Pump HSPF: 7.00 15.Hot water system: 15. Type: Electric EF: 0.90 16.Hot Water Credits: (HR-Heat Recovery, 16. DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or`3 17. 2 18.HVAC Credits (CF-C6iling Fan, CV -Cross verit, 18. �- HF-Whole house fan, RB-Attic radiant --- barrier, MZ-Mu.ltizone) 19.EPI (must not exceed 100 points) 1.9. 80.95 a. Total As_Bui.lt points _ 19a. 25737.63 b. Total Base points 1.9b. 31796.06 - 1 Hareby ix;rfiP: Chat thk- pl.?-ins anti ! Review of ---------------------- the plans: and specifications covered k'- lI-lis c.alcu- ! coVE-red by t:hic-s calculation indicates 1<tion arc i.ri conipli,,uca wiLh the; ! compliance with the Florida Energy Flori.ditt Er,ergy Code. ! Code. Before construction is completed this building will tie inspected for PRtPARED t`sY:! compliance in aecoi vice with Section DATE : R--__._ ,--_--.-- -- ! 553.908 F.S. I hereby certify that this building is in compliance with the Florida Energy Code. OWNER/AGENT: _ _ ! BUILDING OFFICIAL: DAiE: - -- ! DATE:-- •�.:K.K.!'.T .T #- K-K. i- ! .i .K,K Y, h {. A::Y :K:t 1 . K 1. -t: it r 1':1:.k .k'6:K:t- * !: !..!: * * *, t.:4:.K.* .K 4. K:K -!:'I:.T .K'K-i:: SUhI'r1F.:rt CFri I;roNs #:f A %:X4k4:3, X %-:k *'K :K:K M:I: *%::K%':K:T 4:'K X *:K:K:K�;%'.1:�c%:%"%::KA::K:K.1: GLASS ---------------- `OR1EN AREA x C,SPM = ---------------•----------------------------------------------------------------- POINTS ; TYPE SC ORIEN AREA x SPM x SOF = POINTS N 22.00 82.2 1808.4 i SGL TINT N 22.0 51.5 .72 814.6 S 84.00 82.2 6904.8 ; SGL TINT S 84.0 98.3 .45 3699.4 W 73.00 82.2 -----------------------------------------•------------------ 6000.E. ; SGl- TINT W 73.0 107.1 .26 2032.8 .15 x COND. FLOOR / TOTAL GLASS = AD.7. x GLASS = AD7 GLASS ; GLASS AREA AREA FACTOR POINTS POINTS i POINTS .15 1,530.00 .179.00 1.282 14,713.80 - 18 864.90 ' i - 9 6,546,80 NON GLASS------------ � AREA x BSPM = --- POTNTS -------------- ; TYPE R-VALI.IE AREA x SPM = POINis W A l_ L. S - - -- - - - --------- --------------- i Ext 1532.0 1.0 1.532.0 ; Ext IVorml4tBlock [n 4.2 1.532.0 1.16 1777.1 Adj 291.0 .7 203.7 ; Adj Wood Frame 11.0 291 .0 .70 20 +.7 DOORS ---------------- ExE 24.0 4.8 11.5.2 Ext Wood 24.0 7.20 :172.13 Adj 22.a 1.6 35.8 ; Adj blood i 22.4 2.40 53.8 CEILTNGS-------------- UA 1530.0 .6 918.0 ; Under Attic 19.0 1650.0 1..10 1815.0 i FLOORS--------------- � Slb 194.0 -31.8-6169.2 ; Slab -on -Grade .0 194.0 -31.90 -6188.6 INFILTRATION --------- 1530.0 10.9 16677.0 ; Practice 02 1530.0' 10.90 16677.0 TOTAL SUMMER POINTS 32,177.44 ; 21,057.58 TOTAL x SYSTEM = COOLING ; TOTAL x -----------------------------=- CAP x DUCT x SYSTEM x CREDIT L COOLING SUM PTS MULT POINTS ; ----------- ----------------------------------------------------------------------- COMPON RATIO MULT MULT MULT POINTS 32,177.441 .:37 1.1 ,905.6:» i 21 ,057.58 .1 .00 .1 .063 .340 1.000 7,609.6,1 J� 4.:K 4:#:7:'7 T;K•:1:t 4: 1'1':K:I:.K:kV.4: 1;*-4:A:M::K:k:%'*W*:%!t.**-*:4z.K�W:k:k**.%;I:�k�:�:;K:KM:%-K;KA:;k:K;K:K�:K;%**:K:1.:7:-KW�K;k WINIER rF-"II"i.ul_(iT,rurl:; �4:*:7:;%�:�:V.:k:k':K;K'*7=:K;kA:;Y-;1:4:a::%-KA::k%:k::7:Y:�:4':K4.4 Y. X.:K %:::K ':%4:K:KX::K=k:Y•A:.KW-*:l::K *'4'K;i::K *:K �: ;%:K A:;KA M'A ---- i 'Okil_III AREA x NI.IPM PUIIJ'I5 IYPE SC ORIFN ARF..A x WPM x WOF = POINTS N 22 .00 -3 .4 -74 . sj ; ----------- SGL TINT N -------- -------- 22.0 9.6 ---------- 1.. 1 8 ----- - 24'4 S 84.00 -3.4 -285 .6 i SGL TINT S 841.0 -10.2 .12 .4 -104.0 W 73.u0 -3.4 -------•------------------------------------------------------------------------ -248.2 ; SGL TINT W 73.0 -2.0 -5.04 735.8 -lb x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS i GLASS '. AREA .. ------------------------------------------------------------------------------- AREA FACTOR POINTS POINTS i POINTS .1.5 1,530.00 179.00 1.282-608.60-780.30 i 881.16 NON GLASS ------------ AREA x BWPM = -------------------------------------------------------------------------------- POINTS TYPE R-VALUE AREA x I4PM = POINTS, WAl_l_S----•------------ Ext 1532.0 1.1 1685.2 ; Ext NormWtBlock In 4.2 1532.0 3.26 4994.3 Adj 291.0 1.8 523.8 ; Adj Wood Frame 11.0 291.0 1.80 523.ri DOORS ----_•----------- ; txt :?4.o 5.1 122.4 ; Ext Wood 24.0 7.60 182.4 Ad.j 22.,1 4.0 89.6 ; i Adj Wood 22.4 5.90 132.2 CEILINGS ------------- UA 1530.0 .6 918.0 i ; Hnder Attic 19.0 1650.0 1.00 1650.0 i Sib 194.0 -1.9 -368.6 ; i Slab -on -Grade 0 194.0 2.50 485.0 INFILTRATION--------- 1 ; 1530.0 4.1 6273.0 ; Practice #2 1530.0 4.10 6273.0 TOTAL WINTER POINTS ---8,463.10 ; 15,121.83 TOTAL x SYSTEM = HEATING ' TOTAL x CAP x DUCT x SYSTEM x CREDIT = HE WIN PTS MULT POINTS ------------------------------------------------------- ; COMPON RATIO MULT MULT MULT POINTS 8,461.10 1.10 9,309.41 ; 15,121.83 1.00 1..063 .484 1.000 7,779.02 *-K**:k*:K***:k**::k4-k:1':k.A�-ka:K*W:k-kM:K:k�::kX•*:k:k a�AY:H:-K�:k*:K�::K:k:k:l:-i::k'K:K*:k:K:k�*:k****%::k *:K B:*:k**:k:k*:K:I::K WATER MEATING *'tl: *: *:p=t: X.:K:K :i::K * a:'7::i:'X:k'X-M �':k'K *:k *:+::k:K *-k *�::k:K:K'k.k �:k M :K a: ��.;K:K:{::t: •k *:k * *:K * * V: *:K h::K:k * M:k:K:K *:k * �c �c:K * * �c * Y:* �C BASE. ___ --- AS -BUILT NUM .OF x MULT - TOT AI_ TANK VOLUPE EF TANK x MULT x CREDIT = TOTAL BEDRMS ; RATTO MULT -----------'-•---------------------------- 3527_0101581-00_50_901..000--3449,7_-1`00- .10,349.00 K Y. *:K Y::{::K.K:I: a.:k * :k W :i::l::{: k: �c:k:1::K.k *'Y:'k:k:k'K•:k:k W:k:k:k.K * ** * * *.4: * * * *,+: W:k * * * *: %::K:k:k SUMMARY BASF' AS -BUILT ----------------------------------------------------------- COOLING HEATING HOT WATER TOTAL ; COOLIN1G _ HEATING HOT-WATER TOTAL - POINTS + POINTS + POINTS = POINTS ; POINTS + POINTS + POINTS = POINTS -------------------------------------------- ------------------- 11905.7 9309.4 10581.0 31,796.06 7609.6 7779.0 10349.0 25,737.63 EPI = 80.95 v 1 -For detailed information of the HPI rating number or'for any ITEM listed, ask Your' Builder for DCA .For ir, 60OA-93 • o'i Form 60OB-93 ENERGY GLIIDE EPI= 80.9 0 10 20 30 40 50 60 70 80 90 100 --------------------------- The maximum allowable EPi is 100. The lower the EPI the more efficient_ the home ITEM RESIDENTIAL ENERGY PERFORMANCE RATING SHEET HOME VALUF L41NDOl'1S..................... Single Tint INSULATION .......... Ceiling R-Value......... 19,0 Wall R-Value......... 5.3 Floor R-Value......... 0.0 AIR CONDITIONER ............. Low Efficiency SINGL CLR High Efficiency DBL TINT Ft-10 R-30 i---------X-----------, R-O R 7 i-'-------------- R-0 R-19 X------ SEER/EER.................. 10.0 10:X . ____ --_SEER---_---17i0 9.7 EER 16.0 HEATING SYSTEM .............. Electric COP/HSPF........ 7.0 6'8 HSPF 12.0 Gas AFUE............ 0.60 0.78;);90 --------------------- WATER HEATER ................ Electric EF.............. 0.90 Gas EF.............. 0.00 Solar EF............. OTHER FEATURES ............. 0.88 0.96 ---- X-------------- -' 0.54 0 90 ------------- ------- 0.40 0.80 ------ I certify that these energy saving features required for the Florida Energy Code have been installed in this house. Address: Builder Signature: City/Zip, ___ Florida Energy Code for Building Construction - 1993 Florida Department. of Community Affairs FL-EPL CARD93