Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSr ALI APPLICABLE INFO MUST BE COII FOR APPLICATION TO BE ACCEPTED Date: 08/11/2015 Permit Number: � ) v 1 Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line III ti'PRO�MPROVEMENT LOCATION: r Address: 5218 Buchanan Dr, Ft Pierce FL, 34982 Legal Description: Indian River Estates Unit 01-blk 4 lots 19 & 20 9map 341025) (or 1482-2529 ) Property Tax ID #: 3402-602-0125-000/3 Site Plan Name: Posey Residence Project Name: Posey Carport Setbacks Front25 Back:15 Right Side: 10 Left Side: 10 Lot No.19 & 20 Block No. 4 [,,,DETA1LEb IOES,,(RIPTION;OF`WORK: E. Carolina Carport Inc 12x36x8 ft high Metal frame and roof car port to be installed on and anchored to the exsisting 3000 lb fibor crete concrete slab. CONSTRUCTION INFORMATION: ArIflttiona worKto tie nertormed under tispermit—check all apply: FHVAC Gas Tank ❑Gas Piping In _ Shutters Q Windows/Doors 10 Electric 0 Plumbing Sprinklers Ei Generator 1:1 Roof Total Sq. Ft of Construction: 432 SFt of First Floor: Cost of Construction: $ 2900 Utilities: Sewer ElSeptic Building Height: 8 01NNpER/LESSEE:, a CONTRACTOR; NameOames A Posey Name: Owner Builder Address:5218 Buchanan Dr Company: Carolina Carports INC City: Ft Pierce State:FL Zip Code: 34982 Fax: Phone No. 772 332 7336 Address: P.O. Box 1263, 187 Cardinal Ridge Terrace City: Dobson State: NC Zip Code: 27017 Fax: Phone No. 800 670 4262 E-Mail: pose7242@bellsouth.net Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail: cci@ccihq.biz State or County License: Owner Builder If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPTLEMENTALGONSTRUCTIOVOEN LAW,INFORMATION': y DESIGNER/ENGINEER: _ Not Applicable Name: Bechtel Engloneedngand Testing INC MORTGAGE COMPANY: _ Not Applicable Name: Address:605 West New York Ave Address: City: Deland State: FL Zip: 38538 Phone: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before of Owner/ Lessee/Agent s Signature of Contractor/License Holder STATE OF FIL v STATE OF FLORIDA COUNTY OF COUNTY OF The fo dra; instr ent was acknowledged efore me this � day of 20by (Name off*rson acknowledging The forgoing instrument was acknowledged before me this day of (Name of person acknowledging) 20 _by (Signature o Notary Public- State of FloMa (Signature of Notary Public- State of Florida ) )' • d'k(NtY 14i1T<614E Personally Known OR�Pr'1 t e degrjgt ryP�ejr, pally Known OR Produced Identification Type of Identification Produced ! :`- wed hfar22 2U1S of identification Produced c� ®fliffllWOR M EE 877 1L Commission No. �'a 'i,i S�N�@@fpfag®hHtlldnolhint� e ° ission No. (Seal) Revised 07/15/2014 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Planning & Development Services vepartment Building & Code Regulations 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence for your use and occupancy. You may also build or improve a commercial building at a cost not exceeding $75,000.00 as long as it is for your own use or occupancy. You may not build or improve said structures for the purposes of selling or leasing that building. If you sell or lease a building you have built or improved within one year after construction is complete, then a presumption is created that it was built or improved for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a license contractor who is not licensed to perform the work being done. Your construction must comply with all a li bI laws, ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on the minimum code. initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. I understand that if I compensate any person or company for work performed they are rt licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and cost of the license. initial I understand that if any person that is unlicensed and uninsured gets injured on my consi they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and cost, which could include loss of wages during recovery from their injury. Inii To qualify for this exemption under this subsection, an owner must personally appear and sign permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and �o ing Dep nt to the Florida State Department of Professional Regulation. Signed and acknowledged on this day of _ of 20 U+0er/Bui—Ider Signature STATE OF FLORDR COUNTY OF The fo oing ins vment as acknowledged before me this U day of 20� by �Q�. Kjr� who is personally known to me, or who has produce t as identificat Signature of Notary Type or Print Name of Notary (Seal Title: Notary Public Commission Number DAWN MILONE a", „ ;.,,MW !4", Notary Public - Bt3'e of Florida SLCPDSD Revised 05/152014 •; My comm. Expires n,- 22 2017 ;. '%o$,', E F17571 Commission S E :1 Bonded Through National Notary Assn ,r u JOSEPH E. SMITH, CLERK OF TH-URCUIT COURT — SAINT LUCIE C TY FILE # 4100721 OR BOOK 377 r\GE 252, Recorded 08/12/20� 10:47 AM AFrER RECORDINGAMRN TO F PERMITNUMBER: .:Ir •.,rv,,.:ctb i NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: SUBDIVLSION..." BLOCK4 TRACT LOT19&20 BLDG UNIT01 Indian River Estates Unit 01- Blk 4 lots 19 & 20 (map-34/025) (or 1482-2529) 2. GENERAL DESCRIPTION OF IMPROVEMENT: 12X36 Metal Carport 3. OWNER INFORMATION: a. Namdames A Posey b. Addm,,5218 Buchanan Dr, Ft Pierce FL 34982 c. interest in propertyowner d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Owner builder 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: none 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: PNC Bank US1 Port Sain 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: dames A Posey, 5218 Buchanan Dr, Ft Pierce FL 34982 772-332-7336 w 8. In addition to himself or herself, Owner designates- the following to receive a copy of the Lienor's Notice as provided in Sect" p 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: Evelyn D Posey, 5218 Buchanan Or, Ft Pierce FL, 34982 772-332-6449 ¢ o 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is y r specified) 20_ , ` U= w SiWdatum of Owner or Owner's Authorized O Print Name and Provide w�r!�LIJ J=� •r ¢ 1— State of Florida County of The foregoing instrument w knowI d ed before me this _�— day of , 20 By as (N of person) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) f� For f y(—." (Name party on behalf of whom i s ument was executed) Personally Known_ or produced the following type of ID: DAWN MILONE (Printed Name of Notary Public) (Signature of Notary Public) i`i,?•. Utary Publle •State of Florida Under penalties of perjury, I declare that I have read the foregoing and that the facts in it a 6tii;,(q;BCe t��FBq'�IjSlOroaVrrelgart�- belief (section 92.525, Florida Statutes). ed Thraaph National Notary At- Signature(s) of Owner(s) nler(s)' Authorized Otticer/Director/Partner/Manager who signed above: By: By Rev.e IRavNinel y Corporate Office Carolina "11'oll Free: — -- (800).670 4262 P.O. Box 1263 Local: (336) 367-6400 187 Cardinal Ridge Tr. ,.4 Fax: (336) 367-6410 Dobson, NC 27017 Carports, Fax: (336) 367-6411 Email: cci@ccihq.biz Website: www.carolinacarportsinc.com Inc,. FL# - CBC1254822 DEALER f' t or Dealer Phone No. b �" '"Date `Z —'2 e - CUSTOMERNAME N-S"' COUNTY`' 2 S L TAX %-Mhere Ddlivered) ADDRESS 52-1 ID r CITY —1�i ti t z-rc/— STATE 1- 1 0- ZIP= PHONE: WORK HOME OTHER 0 2 `�-) 3 3 z -'13 3 h UNIT SIZE W. Z L. tO Ht. Yj Ga. 14 12 ❑ All Orders C.O.D. C 'I COLOR TOP G ik (v4 n$I ES TRIM Price _ `� 3 T. �r� L• D \I" Subwtal � �d... _ 4WS Down Payment - Before Tax Total 2— 1 . Additional Labor Charge ' Ba11= ❑neon l al Instal I FT. SHORTER THAN ROOF LENGTH NOTE: FRAMElati Roof Style Regular ❑ Boxed Eave ❑ Vertical Installation Type Cement �!r Ground ❑ Asphalt ❑ Other ❑ Power Available Yes MNo ❑ Uncertified ❑ Certified ❑ BINDING PURCHASE CONTRACT This purchase agreement (the "Agreement") is made by and between Carolina Carports, Inc. ("CCI" ), a North Carolina corporation, and --'S Iv��? O SLO S� (the "Buyer"). Buyer agrees, after being fully educated about CCI's various products including the fourteen (14) gauge, twelve (12) gauge, and certified units, to buy, and CC) agrees to sell, pursuant to the terms listed in this Agreement, the item described above. Buyer has read and understands the terms of this Agreement, including the terms and conditions contained on the reverse side of this document, which terms are expressly incorpdrated herein by reference, as well as any and all relevant warr ��ryr in orm n, and agrees to be bound by same. ' Customc CCI: - Email: By. Authorized Dealer J Z 3 \ How did you hear about C.C.I?: 13 C.C.I. Event m C.C.I. REP C3 Word of Mouth ❑ Other b� �mn O 4c 7J � ti :D S st m n Ct- UI U G m53 rot =v S. L X'C a)J �3 m nm c C D {, n 0. o= BRADLLEY STREET h BOUNDARY FOUND IRON ROD NO /' � ®V 1 V D J 1 � A R S R VE •L- N.W. CORNER OF LOT 1, BLOCK 4 INDIAN R/YER ESTATES UNIT 1 SEP77C BEYOND 75' OF PROPERTY 1 V 1 ,� EXISTING RESIDENCE lSH FLOOR ELE VA77ON = 19.4 Prim e o - LOT 18 C>tjr�0✓`� ,1 ,1`` $ +'6' '00,�0"E 300.00'(P) 299.92(M) IDLY 3(� ,ab 15� ROD &0 IRFOUND 0 RON 19 + POWER PO[E , � I FOUND J5 IRON ,1 -� / ,1• s cAP (aa ,vml ' PROPOSED DRIVEWAYMIN. 150.3 - LOT 1 103.0' I � I SE FRONT VACANT LAND 4& I �3 1" ) I h 0 SIDES [ Q W GSB' Q� Q �,1ry�4 `109 CNR SIDES _4A ,6i RFnR I �1a VS7LIRY h \PROPOSED 11• \k•; �1 O ZNG. _— LjU yp Q TECHyl��" J$O1503' D0' 0 ,o O co s ,1• L� 20 A PROPOSED ___ 1 ^�i I 12 IJM.* INSTALL AREA f y /� y. I b 0LA—L SOUARE FEET •• L%DTAL AVAICAB/F - �• +' .-- -" C. :. .1 _ Q• "'/• s ``: . 8 .. CORNER COVEREO a Frs BroEeRls N57 't c B� i - _ _ I N. 90. 0'00"E �ja 00'(P & M) jf I _ _... �A�• �_�j VICANT I I LAND LOT 21 II 1 LEGAL DESCRIPMW..• LOTS 19 & 20, BLOCK 4, /ND/AN RIVER ESTATES UNIT ONE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK f0, PAGE 43 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURVEYORS N07ES 1. LANDS SHOWN HEREON HERE NOT AB57RACTEO FOR EASEMEA17S AND/OR RIGHTS IOF WAY OF RECORD EXCEPT AS SHOWN ON THE RECORD PLAT IF ANY. 2. NO ATTEMPT WAS MADE BY THIS FIRM TO LOCATE UNDERGROUND FOOTINGS OF BUILDINGS OR FENCES ON OR ADJACENT TO THIS SITE. -AR/NGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF S.00170 00 oT RIGHT OF WAY LINE OF BUCHANAN DRIVE. IN FLOOD ZONE X' AS SHOWN ON FEMA MAP No.1202B5-02 D-F, 9• 199L '00.00 SOUARE FEET OR 0.909 ACRES MORE OR LESS 'ON FURNISHED BY CLIENT ARE BASED FROM NA770NAL GEODETIC WER77CAL DA7UM OF 1929. CER77RCA77ONS 1. JAMES & L YNN Pl SEY SURVEYORS' CERl1f7CA77aV- I HEREBY CER77FY M4T THIS AOF SURVEY WAS PREPARED UNDER MY RESPONSIBLE CHARGE ANO PLMELTS T 7HE MIN/MUM TECHNICAL STANDARDS'AS SET FOR771 BY 7HE F:ORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS IN CH✓P7ER'61G77--6, FLORIDA STATUTES, AND THAT /T IS TRUE AND CORRECT TO THE BEST OF A!Y KNOWLEDGE AND BELIEF. NOT VALID WWUr 7HE S16NA7URE AND THE ORIGINAL RAISED SEAL OF A FLORIDA ROBERT BLOOMS7ER o PROFESSIONAL LAND S NO. 4134 STATE OF F. LEGEND I. (P) = PLAT 2. (M) = MEASURED J. L.B. = LICENSE BUSINESS BLOOMSTER PROFESSIONAL LAND SURVEYORS,INC. 791 NORTHEAST DIAE HIGHWAY JENSEN BEACH, FLORIDA 34957 PHONE 561-334-0868 LOT 47 LOT 48 C \�y Y, LOT 49 ��°Q� � 1 LOT 50 PREPARED FOR JAMES & L MN POSEY BUCHANAN DRIVE" ST. LUCIE COUNTY, FLORIDA. TABLE 1 BOW/RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS, AND POSTS OR GIRTS WIND ULTIMATE NOMINAL POST / RAFTER (INCHES) INTERIOR END EXPOSURE WIND SPEED WIND SPEED SPACING CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 115 TO 150 89 TO 116 5.0 6 6 B, C, or D 151 TO 180 117 TO 139 1 4.0 1 6 6 NOTES: 1. Specifications applicable to 26 gauge metal panels fastened directly to 12 or 14 gauge steel tube bow frames. 2. Fasteners consist of 1/4• 14M" self -drilling screws with control seal washer. 3. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7" to 27" (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. APPROVED PRODUCTS LIST PRODUCT CATEGORY SUB CATEGORY MANUFACTURER APPROVAL No. & DATE STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL6596.R3 26 Gauge AG Panel 06/28/15 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.R3 26 Gauge AG Panel 06/28/15 EXTERIOR DOORS SWINGING POCAHONTAS ALUMINUM COMPANY, INC. FL12903.R3 Model DD100 07/16/15 EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.R4 ' Model 203 05/31/15 WINDOWS SINGLE HUNG POCAHONTAS ALUMINUM COMPANY, INC. FL12940.R3 Model 100 VS I 07/08/15 METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS FOR CONSTRUCTION IN THE ` STATE OF FLORIDA TERa.� �tki41E�Y:.:.dk •I�a ,J. 1.a:CC.v PREPARED FOR: /�u( �{3`d� e? +,�^Ilq�' A cy.q .,� -� n�' CAROLINA CARPORTS, INC.1/)j e-C7 r5 0�..., Y.�! �tai 1 �'�(,ji�� P.O. BOX 1263 (f DOBSON, NORTH CAROLINA 27017 BUIL61N PREPARED BY., BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 CONCEALED FASTENERS OR ATTACHMENTS Certificate of Authorization No. 00005492 ARE THE RESPONSIBILITY OF THE CONTRACTOR OFREC09D CONCRETE NOTES: (THESE ARE RECOMMENDATIONS ONLY (INCLUDING DIMENSIONS OF FOUNDATIONS FOR BASE RAIL ANCHORAGE DISPLAYED ON SHEET 3 OF 4). BECHTOL ENGINEERING AND TESTING, INC. AND CAROLINA CARPORTS, INC. ARE NOT RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF CONCRETE FOUNDATIONS) () !?- Q / CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF ST. LUCIE COUNTY 2500 PSI AT 28 DAYS. BUILDING DIVISION REVIEWED COVER OVER REINFORCING STEEL FOR CO I CE FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFROCING BARS REVIEWED BY SHALL BE: DATE 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PLANS AND PERMIT PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR MUST BE KEPT ON JOB OR WEATHERAND 1-112 INCHES ELSEWHERE. NO INSPECTION WILL BE MADE REINFORCING STEEL: THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. THIS IS TO CERTIFY THAT THE CALCULATIONS AND GALVANIZATION: SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT THE UNDERSIGNED PROFESSIONAL ENGINEER, AND DIRECTLY EXPOSED TO THE WEATHER SHALL BE GALVANIZED IN ACCORDANCE ARE IN ACCORDANCE WITH THE REQUIREMENTS OF WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS AND SECTION 1609 OF THE FLORIDA BUILDING CODE, NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE STAINLESS STEEL OR FIFTH EDITION (2014). THE PLANS ARE VALID UNTIL HOT DIPPED GALVANIZED. THE NEXT REVISION OF THE FLORIDA BUILDING CODE. \`\x%%%lI1111///Y', �. gRHe GENERAL NOTES: 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THESE STRUCTURES ARE DESIGNED AS UTILITY/STORAGE BUILDINGS CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. AND ALL PROPOSED WORK 3. ALL STEEL TUBING SHALL BE 50 KSI STEEL. THESE PLANS TO ANY CORRECTIONS 4. FASTEN METAL ROOFAND WALL PANELS TO FRAMING WITH 1/4° x 1' SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER Q 6" O.C. AVERAGE. ARE SUBJECT REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO 5. ALL FIELD CONNECTIONS SHALL BE 1/4' x 1• SELF DRILLING SCREWS. COMPLY WITH ALL APPLCAOLE CODES. 6. ALL SHOP CONNECTIONS SHALL BE WELDED. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS ARE ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. 8. CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. DELAN'O-'—I�§A 32720'910. 38538 Co'"_Ieg*oltratlon No. 6492 Thomas ST OF .•• (v FlodHa U®na4 •• Ink OVERALL LENGTH VARIES 26G GALVAN�D METAL ROOF PANELS FPSTENEO TO RAFTER WRH 1M• x 1• GOFN WITH CONTROL SEAL WASHER (SEE TABLE 1 FOR FASTENER SPACING), _ J1 I 9 u. 9 1 1 i � .Y � a BOX CAVE OPTION SIDE EXTENSION -24• 16 GA UCW.NNEL BRACE FASTENEDTOFACHBOWFRAME WTIH 19• x I-SDFs MONOLITHIC SLAB FOUNDATION CONTIMIOUSCONCRETESIAB (OPEN CARPORTS ONLY) 30'-0' MAX. RAFTER 1 ANcxoNsxDT AEweEDWmI TYPICAL BOW RAFTER SECTION FAxORE1E5UBCOUSIRUCRM Not TOSOaI• (sEE P ETAIL t OR z GHFET s of •) 26 GA GALVANIZED METAL ROOF PANELSTH CONTROL RARER HM 1/4'.(SECTiWR FOR FASTENER SPACHER 12 (GEETABLEIFOR FASTENER SPACING). 3F, --.i�� BOX CAVE OPTION SIDE EXTENSION INISH GRACE MONOLRHIC SLAB FOUNDATION OR TOP OF CONCRETE (OPEN E W NIRP RTS ONLY) SLAB (OPEN CARPORTS ONLY) TRUSSED BOW SECTION NWTOS®N BOX CAVE OPTION UE MRARER SET MONOLITHIC SLAB FOUNDATION CONTINUOUS CONCRETE SIFS (OPEN CARPORTS ONLY) �14'-0' MAX. SPAN 3('-0' MAXIMUM_ RAFTER SPAN axcxons roTREauwEDwTm CONCRE}E 81AS COHSIR WIp4) ISEE CETNL t OR1. SIIFEf 9OF 41 TYPICAL SIDE/LEAN-TO EXTENTION SECTION Not To Scale 6' TYP. W a DEPENDS ON NUPABER AND SPACING OF BOWS �1-1�1—�I�1■ �1-I�1-�I-1■ I'SIDE SEE TABLE I OR END SEE TABLE i SEE TABLE I SEE TABLE �1=1 LITIIIIn1111u1111n11111T1110 111 111aIIISIIIu1111111;�1111 �1111 �111111111 IUIIIIIUIi)IIa01?I)III II11 a ulwORs xoruou•1FnwrtN Cdl }[ JjL�• P, j 61,{V!f F r g -1r- I Da yz .9°F,) 0 `NE rlfi l A BUILQINC, WIDE F' ROUNDANCHORS C EACH ENO SIDE ELEVATION INfERIOGRAFIUERI�TiorwTioN NNT. St (SEE DETAIL 3, SHEET 3OF4) END WALL OPENING ANg1Og6 NOT RLWwEO WmI Not To Sm 14sEEon,1Ei 1�ORBIEE9oFij THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT IAAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. GABLED OPEN END WALL SECTION Not TO SwIe I.NGpR9 NOTREWIVEPWTI SONGRIE: CONCRMESLAB SONSIRIICIIGI ($EEOETA6 (GEEOETNLI OR].sNEETioFQ Zb G0. GALVANIZED METAL ROOF PANELSFH CONTROL RAFTER HER 1/4'x 1- SOPo LEIII CONTROLSEAL WASHER (GEE TABLE1fORFASTENERSPACING) ERECT OF LVANIZED ,OF PANELS S BOX SAVE OPTION 3 A 3 1 MONOLTHIC SLAB FOUNDATION 2 1 CONTINUOUS CONCRETE SLAB 3 (OPEN CARPORTS ONLY) ANCXORS HOTREo11WFD WIIN CONCRETES CONSIR 4) (6EE DETM 10113, SfRET30F4) x 3C WR11 �L 4•HELIX WTII-0N 6.OF FACN BOW WITH EXTENGIONS (SEE DETAIL 3, b1{EEf 9 OF 4) TYPICAL FREESTANDING LEAN-TO Not To Scale OWN ENGINEERING, 30' LONG WTH ROD AND DBL 4' HELD( EYE ANCHDR DETAIL 3, SHEET 3 OF 4) SIDE OPENINGS Not TOSFBI• END WALL SECTION �M=ASMUM ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD SEE TABLE 1. SHEET 1 OF 4 26 GA GALVANIZED /�METAL ROOF PANELS —TS ENDWALL POST �6 GA GALVANIZED METAL SIDE PANELS —GROUND ANCHORS @ EACH END RAFTER POST AND EVERY OTHER END POST LOCATION (SEE DETAIL 3 ON SHEET 3 OF 4) NOTE: 14 GA FRAMING IS 2.1/T • 2-17 TUBE STEEL (TS). 12 GA FRAMING IS 2-1/4• x 2-1/4•TS. NIPPLES ARE 2-1/4' x 2-1/4' 12 GA TS FOR 14 GA FRAMING. NIPPLES ARE 2• x 2' 12 GA TS FOR 12 GA FRAMING. .. 11II II.. INSTALL 12' x MINIMUM W EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER POST ALONG SIDES AND INSIDE EVERY OTHER END WALL POST ALONG END WALL SECTIONS T MINIMUM MINIMUM 2.12' EMBEDMENT 12" . 12' ONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 P5's CONTINUOUS �1 CONCRETE BASE RAIL ANCHORAGE 1 Not To Scab (OPTIONAL) DRILL 5/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 112' DIAMETER THROUGH -BOLT /A� WASHERS / I ITS CONT. BASE RAIL MINIMUM 4' L CONTINUOUS 4' CONCRETE PAVEMENT EYEANCHOR 518" ROD 24' LONG �F WITH DBL 4' HELIX CONCRETE BASE RAIL ANCHORAGE Not To Scab (WHERE SLAB IS TOO NARROW TO USE CONCRETE EXPANSION ANCHOR BOLTS) TS RAFTER POST 2k4' 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH 1/4' x 1' SDFs, 2 ON POST AND 2 ON RAFTER TS 2Y452' 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH 1/4'x 1' SDPs, 2 ON RAFTER, 2 ON POST INSTALL 1/2' x MINIMUM 5- EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER POST ALONG SIDES AND INSIDE EVERY OTHER END WALL POST ALONG END WALL SECTIONS 1---- 1 MIN. 6- 2-12' EMBEDMENT NO SCREWS REQUIRED IN BOW BEND 24- 16 GA U-CHANNEL BRACE (S TOT POST) 46' 16 GA U-CHANNEL BRACE (8' TO 14' POST) RAFTER BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL NOTE: BRACE NOT REQUIRED AT CORNER IF END ENCLOSED 24' 16 GA U-CHANNEL BRACE (5' TO T POST) 48' 16 GA U-CHANNEL BRACE IS TO 14' POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL NOTE: BRACE NOT REQUIRED AT CORNER IF END ENCLOSED / MINIMUM 4"� 5" 3' �6LONG TS 12 GA NIPPLE 6' LONG TS 12 GA NIPPLE SECURE POST TO NIPPLE WITH SECURE RAFTER AND POST TO 41/4' x 1' SDFs CONTINUOUS 43' ' CONCRETE PAVEMENT NIPPLE WITH 4 TS RAFTER POST SELF•DRILUNG FASTENERS ERSV.-Ts RAFTER POST GCONCRETE BASE RAIL ANCHORAGE Not To Scale (OPTIONAL- OPEN CARPORTS ONLY) DRILL 5/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 11T DIAMETER CONT. BASE RAIL TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE EYEANCHOR U 5/8' ROD 24' LONG WITH DBL 4' HELIX �1 BASE RAIL ANCHORAGE Not To Stale CONCEALED FASTENERS OR ATTACHME TS - . 2 12 FOR ARE THE RESPONSIBILITY OF THE 14�FROIRNG CONTRACTOR OF RECORD 1 12GAFRAMING POST / LEAN-TO RAFTER CONN. DETAIL O Not To Stale �1 BOW RAFTER/POST DETAIL BOX EAVE RAFTER/POST DETAIL Not To Stale s NoI TO Scale FILL Yoh NIPPLE TO 3/16' 6' LONG TS 12 GA NIPPLE RAFTER SECURE WITH 4 1/4SU' SDFs 12' LONG TS 12 GA NIPPLE. SECURE POST TO NIPPLE WITH 4 lW x l' SDFs, 1-1R' x 1-02' x 2' 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL W/ 41/4'Al" o SDFs, 2 ON TOP, 2 ON BOTTOM 7-12'x 1-12'x 2' 16 GA 6' CLIP ANGLE SECURE TO RAFTER POST AND GABLE 24.16 GA U-CHANNEL BRACE (5' TOT POST) RAIL W/ 4 1/4'xl' SDPs 48.16 GA U-CHANNEL BRACE (8' TO 1W POST) 2 ON TOP, 2 ON SIDE TS GABLE RAIL BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL TS RAFTER POST NOTE: BRACE NOT REQUIRED AT CORNER IF END ENCLOSED TS RAFTER POST Tt:ESET114�1`6�tAYE8"'E+ ElfE��o�� 1 @ c r v w'�1�{ e1„ ai toy .ill kH, � 1E d II I ,11,1f t i%r) � `Z F t li�U'C%`ii.�IiiYVW 1✓/1)i9 :Id � ��a 1 01JIMPIC. CODS. RAFTER PGSMOXEOAT45 DEGREES, WITH 2.114'x 1' SELP-0R NGSmEWSAT EACH END (4 PER E) BRACE SECTION Not To Scale SIDE EXTENSION RAFTER/POST DETAIL Nat To Scale 1.12' 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2)1/4' x 1' SELF -DRILLING FASTENER SPACED NOT MORE THAN 48' O.C. GA. METAL ROOF PANEL GABLE RAIL TO RAFTER POST CONNECTION DETAIL Nol To Swie NOTE: 14 GA FRAMING IS 2-12' x 2-12'TUBE STEEL (IS). 12 GA FRAMING IS 2.1/4' x 2.1/4' TS. NIPPLES ARE 2-1/4' x 2-1/4' 12 GA TS FOR 14 GA FRAMING. NIPPLES ARE 2- x 2'12 GA TS FOR 12 GA FRAMING. THESE PLANS AND ALL PROPOSED frN6mag� ARE BU13JC•CT TO ANY CORRECTION.. Fl01�_ RJIQUIRED 13Y FIELD INSPECTORS THA RDER TO COMP Y W THSSARY A66APP OCAS E CODES. Q� ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Smle DEL. HDR. RAFTER POST 6' LONG TS 12 GA NIPPLE LONG TS 12 GA NIPPLE. SECURE EACH WITH 4 114'x1' 11 SECURE WITH 4 NI z L SELF -DRILLING FASTENERS 1/S' SELF -DRILLING FASTENERS RAFTER POST/DBL. HEADER DETAIL Not To Scale 2'A2'kT 16 GA ANGLE CLIP SECURE TO POSTAND RAFTER WITH 114'a 1' SDFS, 2 ON TOP AND 2 ON SIDE END POST END POST/RAFTER CONN. DETAIL Not To Scale i' x i' SDF 12.O.C. ROLL -UP DOOR GUIDE TO POST CONNECTION DETAIL Not To Scale CURTAIN: 26 GA. galvanized steel with baked on epoxy primer S polyester top coat HEADER NIPPLETO DBL. HDR. RAFTER POST/HEADER DETAIL Not To Spie TS RAFTER r I: AR)fs bJz yl4 1 L}p�d�P�x�'[:til'�1 Ui.v" o-sta WILD NI ldtl 9x 1-11T x 1-1/2' x 2' 16 GA CUP ANGLE SECURE TO POSTAND BASE RAIL WITH 4 114*0' SDFS CONTINUOUS BASE RAIL END POST/BASE RAIL CONN. Not TO Sole TS POST a a 6' LONG TS 12 GA NIPPLE SECURE EACH WITH 4 114' x 1' SELF -DRILLING FASTENERS . ITS POST CONTINUOUS BASE RAIL TO RAFTER POST/BASE 3 BASE RAIL CONNECTION DETAIL Not To Scale TS TRUSSED RAFTER CHORD, OR NONSTRUCTURAL HEADER TS END POST OR DOOR/ WINDOW FRAME POST TS BASEANINDOW RAIL OR NONSTRUCTURAL HEADER 2'x2'x2' 16 GAANGLE CLIP SECURE TO POST (EACH SIDE) AND RAFTER CHORDIRAIL WITH 4-114'x1' SDFS, 2 ON BOTTOM AND 2 ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL Not To NJ 0 POST FILLUPY 6' LONG TS 12 GA NIPPLE ,,--2'x 2'x 2'16 GA ANGLE CUP SECURE WITH 4114' x A SDF's SECURE TO POST AND TOP OF HEADER, OR BOTTOM OF WINDOW RAIUGIRT WITH 114'x 1'SDFs TS NONSTRUCTURAL HEADER TS WINDOW RAIL (OR GIRT FOR VERTICAL SIDING OPTION) NON-STRUCTURAL HEADER, WINDOW RAIL, OR GIRT TO POST CONN. DETAIL Not To Scale THESE PLANS AND ALL PROPOSED WOR!. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER -- COMPLY WITH ALLAPPLICABLE NIPPLETO BASE RAIL CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECARB A SECTION Not To Scale 114' x 1' SDF Q 12- O.C. RAFTER POST CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL 8 Narosme NOTE: 14 GA FRAMING IS 2-11Y x 2-10TUBE STEEL ITS). 12 GA FRAMING IS 2-114' x 2-1/4' TS. NIPPLES ARE 2-11V x 2-1W 12 GA TS FOR 14 GA FRAMING. NIPPLES ARE 2' x 2' 12 GA TS FOR 12 GA FRAMING.