Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSt ALL APPLICABLE INFO MUST BE CON I, c TED FOR APPLICATION TO BE ACCEPTER Permit Number: 1 X 9- oa3$ SCANNED BY s . i St. Lucie County RECEIVED Building Permit Application AUG 111205 Planning and Development Services PEBMiTTING Building and Code Regulation Division St. Lucie County, FL 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x Date: PERMIT APPLICATION FOR: Dock/Seawall III I PROPOSED IMPROVEMENT LOCATION:. III Address: 10701 S. Ocean Dr., Lot 676, Jensen Beach, FL 34957 Legal Description: Venture Out - Section C - Lot 77 (OR 3611-589) Property Tax ID #: 4511-805-0077-000-2 Lot No. 676 Site Plan Name: Venture Out -Section C-Lot 77 Block No. Project Name: WilriSCheA 3ISO WMI Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: Install 43'+/- seawall concrete with concrete cap within 18" wet face to wet face of existing wall CONSTRUCTION INFORMATION: III IJHVAC U Gas Tank E] Electric 0 Plumbing Total Sq. Ft of Construction: Cost of Construction: $ 21500.00 Piping ❑_Shutters ❑Windows/Doors nklers ❑ Generator ❑ Roof S Ft. of First Floor: Utilities: []SewerE]Septic Building Height: OW N E RAESSEE: CONTRACTOR: Name Paul Wrischel Name: R. Williams Address:10701 S. Ocean Dr., Lot 676 Company: Wilco Construction, Inc. City: Jensen Beach State: F� Zip Code: 34957 Fax: Phone No. 4IQ .L75a . 90I? Address: 4675 N. US 1 City: Ft. Pierce, FL State: FL Zip Code: 34946 Fax: 7724606929 Phone No. 7724606928 E-Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) E-Mail: wilcoinc@bellsouth.net State or County License: 15li5 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. LIEN CAN/'I Name: City: Zip:: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: Address: City: Zip: Phone: MORTGAGE COMPANY: _ Not Applicable Name: Address: City: State: Zip: Phone: BONDING COMPANY: _Not Applicable Name: _ Address: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before Signature of Owner/ Agent/ Lessee Signature of Contractor License Holder STATE OF FL COUNTY OFORIDA ,c I � I OUNTYOFORIDA a "cti J The fo)�ggoing instryr�ent was acknowledged before me The forgoing instru nt was acknowledged before me this —day of WCII( 20 -Mby this Nay of mjy k 20—Wby 12. kJ I li dms V W it lr'ami (Name of person acknowledging) (Name of person acknowledging) DW4 4Q� i %QQ�:== (Signature of Notary Public- State of Florida) (Signature of Nota Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Produced Commission No. Revised 07/15/2014 CCDAWN R�lQGS'" E PIRBS eEeDmber 17 2017 B,d,dThm NolarPoNG Niderw*m Personally Known. OR Produced Identification Type of Identification Produced Commission No. 1506- 0X3 8 December REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE Il COMPLETE II INITIALS 51pP�EMENTAI COAISTftUGTi4N LII`LAatU 1NFORN�ATfON >� .*>Cairv7l DESIGNF �R/�E�NGINEE Not Applicable MORTGAGE COMPANY: Not Applicable Named ll��er�r�iircl Name: _ Address: I o (i moil )2d4 Address: City:° elLe State: City: State: Zip: `ri Phone:' Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recordine vour Notice of Commencement. ✓-A AUG 17 2915 Signature of Owner/ Agent/ Lessee Signature of Contractor/Eicense Holder ENVIRONMENT STATE OF FLORIDA C I I STATE OF FLORIDA I 1 RESOURCES COUNTY OF �-r� COUNTY OF 1 1dCJLQ� The fo oing instr ent was acknowledged before me The forgoing instru nt was acknowledged before me this l day of 1i(f�USt 2016 by this I�day of— au 20- by 12. V4l �` ll r'1rnS �, W 11(r'cmS (Name of person acknowledging) . (Name of person acknowledging) DW44102 (Signature of Notary Public -State of Florida) (Signature of Nota Public -State of Florida ) Personally Known V OR Produced Identification Type of Identification Produced Commission No. Revised 07/15/2014 DAWN FHMEW MY t:U JON 0 FF077529 EXPI S: ember T7,2017 Banded T hm ibM Polk UMamTb% Personally Known _ Type of Identification Commission No. 1306— c) OR Produced Identification REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW CATE ]f QREVIEW OMPLETE INITIALS r FORM #101 TO BE USED FOR VENTURE HARBOUR INC. L_ Xjm P#-rz' VENTURE OUT at INDIAN RIVER INC. VEMUREOUT09ELUCMINC SY S a 7.%2. NUMB: This fonn must be attached and made part of all dntwings or plans regarding the Installation, consintction, remodeling, setting or resetting of any permanent structum, concrete work, or any other type of work that may be effected by the rules, regulations acid bylaws of any ofthe above associations This form shall also serve as notice to the owner or owners ofLot # that the owner or owners or their agents of Lot # shall solely or jointly be responsible for the proper setting and complianoo of all rules, regulations and bylaws of any of the above associations, and the Codes, Laws, Rules and Regulations pertaining to said work as set forth by St. Lucie County. The owner, owners, or their agenis by signing this form shall hold hannless any of the above associations, its officers, directors and committee personnel as pertains to its and their duties and responsibilities as the administration of said work. Said work is approved as per dimensions shown on attached plan or drawing this, Date 3 6A461 1 Scope of work 5�ut Wa Association Building Committee By, By: c Association By: Date: 3%2c?�Z6r� ADDENDUM Qittmdor agrees to atdtched lndemrdEcation fivevocably Indent*, save hanniess and pay to adjnem assocktions against any loss, oast, damage or (y adsing comtructioubythe Buiiderfortheowtterso re velot rider) wawa art; and also agrees to Ina��ryyofthe above or Indinw* out of work or 11/02/2015 11:01 FAX 772460ir,-'°I WILCO JOSEPH E. SMITH, CU,ERT,. ,'% THE i. ;UIT COURT — SAINT LUCIE COUNTYV ME # 4127249 OR BOOK 3803 r" 2532, Recorded 11/02/2015 at C. 0 AM s J t' NOTICE OF COMMENCEMENT Portefema. I 5Jo Tax Folic, No. S- 000—� 94, State of Florida County of St. Lude Z 004 Tit undersgned hembyglyos naUcethat Improvement wilt be made to certain oral property, and In 1CWrd3rrce with Chapter 713, Findda Statutes, the following Information is provided in this Notice of Commencement d lleaalpGprd Property: andareetaddr ifavagabla); to? -Of 5. y'h 6 p rTEaoSeh 16el - Lot 74 ! y1 J2 361I .. S1C9) General dewtptlw of Improvemene Owner Iptqq�(R1pla n orlassee 1p,'d'lo�,^�rr,•w•ry��t��uo If the Lessee wntractd lot the Improvement: Name �QLLSChnl 1',�*,•L•p�sr.TIR�,TT�-�7ra� r'•tw�ii:�i'7�LA.�7�� Namt and address of tee Simple titleholder (if different from Owner listed obove): Contractor's Safety (if split fablt. a miry of the payment bond is Ma had): Amount d borW; S Namead addres: Phone number: Lender Nippon Phone Number: lender's sddrers_ Persons whi tftoStow of Florida deslpnaNd by Career upon whom liens Or other dowmeots may be aayved as provided byswuq C!--I tray Mal) (e)7., FbrNa Stldnt= m Name: Phone Number-. .'v� zr^r =cm 7s n G Address: G p g en m m =v M , 0 In addition to hMeeNar henwR, OWnerdedgruees Pf onseWea tops n t< x 9yza LNpors Notice asprovldd In Section Z19.11(11(b), Florid a Statutes. C Phone number of persrm er anthydesipatd by oAnOr. [� y m =R K a n Eapigean date of notice etoommenxment:(Neexpurtion date may not be before the completion ofconsvucNanand Penal payment �Fi oa contractor, but will be l year from the date of retarding unim a different date is spcclllacil CAFE WARNING TOOWNER; ANY PAYMENTS MADE BYTHE OWNER AFTERTKE EXPIRATION OFTHE NOTICE OFCOMMENORMEN"ARE CONS RED � W IMPROPER PAYMENTSUNDER CHAPTER 713.PARTI.SECTLON 713.13, FLORIDASTATUrES,ANDCANRESULTINYOURPAYINGTWICEFO -yy tMPROYEM£NTSTO YOUR PROPERTY, A NOTICE OF mMMENCEMEW MUST BE RECORDED AND POSTED ON THE)OB SITE REFORETNE m p NaPECIRN. IFYOU INTENDTO OBTAIN FINANCING, CONSULT WMM YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORKOR RE(DROINGYOUR NOTICE OFCOMMMCEMENT. U rp "a *duty, "re that l haA)r . the orc0ng 1101101i of W.h imrlCemerll and that the feclsstated therein are true to the best Lessee, or Owners DWYLP� WgnateNsThla/IXfi.e) •._•.• ... ThefereReina inswment vns admawledgd bda meth.-LL day dhd,;DL4 6y 11,Tr as for 5� i Name AF pefap Type of authority (e.g. officer, trustee) party on behalf of whom instrument was executed Personaay krrown_ or Produced idemlOcati. V ( um of Nola PWaitC- State f abddld t ,a,�/� (Prim,Type, or Stamp C.emmNdomd Name of Notary public) 4 Type of Identification pleduead&&Lwn C. COMe1DMWKALT OFPEVN5yLV"1A NOT� API 6-CAL KART 1VIN MATE U, ?4-um FLVNIa Mdnroovlk6oro..Ai :an/Coun CarlBlds�ionEz ices blue 21, 17 - ... ._._- .w May 16, 2014 S%' 5T. LUC� COU UILDING DIVISION REVIEWED FOR CO. LIAN'CE'n REVIEWED BY`� Paul Winschel DATE 340 Church Road PLANS AND PEMT MUST BE KEPT ONJOB Pittsburg, PA 152350RNOINSPECTION WILL BEAIADE. Sent via e-mail to agent: linenviron@yahoo.com FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION SOUTHEAST DISTRICT BRANCH OFFICE 337 N US HIGHWAY 1, SUITE 307 FORT PIERCE, FL 34950h255 (772) 467-5500 t17_� r ] { lil�l`I�b i U ems p-tic piT 5i4E5 �CWRS l REAR ZNG. Re: File No.: 56-0325514-Oo 1 THESE PLANS AND ALL PROPOSED File Name: Winschel, Paul K ARE SUBJECT TO ANY CORRECT REQUIRED WIELD INSPECTORS Dear Mr. Winschel: 9MAY BE NECESSARY IN ORDER RICK SCOTT GOVERNOR CARLOS LOPEZ-CANTERA LT. GOVERNOR T. VINYARD JR. SECRETARY On April 3, 2014, we received '�yt»sF "7i'ifiift!n"- E on May 6, 2014, the application was complete to repair and replace an approximate 43 linear feet of seawall within a maximum of 18-inches waterward of the existing wall (measured wetface to wetface), including a 28 inch concrete cap and a maximum of seven king piles and seven batter piles, as shown on the attached drawings. The project is located within a manmade canal off the Indian River, Class III Waters of the State, adjacent to 10701 South Ocean Drive Lot 676, Jensen Beach (Section 11, Township 37 South, Range 41 East), in St. Lucie County (270 16' 4.99" North Latitude, 80° 12' 29.76" West Longitude). Your request has been reviewed to determine whether it meets the requirements for any of three kinds of authorization that may be necessary for work in wetlands or waters of the United States. The kinds of authorization are (1) regulatory authorization, (2) proprietary authorization (related to state-owned submerged lands), and (3) federal authorization. The authority for review and the outcomes of the reviews are listed below. Please read each section carefully. Your project may not have qualified for all three forms of authorization. If your project did not qualify for one or more of the authorizations, refer to the specific section dealing with that authorization for advice on how to obtain it. 1. Regulatory Review. — VERIFIED Based on the information submitted, the Department has verified that the activity to repair and replace a seawall, including batter and king piles, is exempt, under Chapter 62-330.051(12)(b), Florida Administrative Code (F.A.C.) and Chapter 62-330.051(12)(d), F.A.C.; from the need to obtain a regulatory permit under part IV of Chapter 373 of the Florida Statutes. This exemption verification is based on the information you provided the Department and the statutes and rules in effect when the information was submitted. This verification will expire after one year, and will not be valid at any other time if site conditions materially change, the project CONCEALED FASTENERS OR ArrACHM ARE THE REPONSIBIL)TY OF THE www.dep.stateftusMOTOHOFfilon COPY File No.:56-0325514-001 File Name: Winschel. Paul Page 2 of 3 design is modified, or the statutes or rules governing the exempt activity are amended. However, the activity may still be conducted without further notification to or verification from the Department after the one-year expiration of this verification, provided: 1) the project design does not change; 2) site conditions do not materially change; and 3) there are no changes to the statutes or rules governing the exempt activity. In the event you need to re -verify the exempt status for the activity after the one-year expiration of this verification, a new application and verification fee will be required. Any substantial modifications to the project design should be submitted to the Department for review, as changes may result in a permit being required. Conditions of compliance with the regulatory exemption are contained in Attachment A. 2. Proprietary Review. — NOT REQUIRED The activity does not appear to be location on sovereign submerged lands, and does not require further authorization under chapter 253 of the Florida Statutes, or chapters 18-20 or 18-21 of the Florida Administrative Code. 3. SPGP Review — NOT APPROVED Authority for review - an agreement with the USACOE entitled "Coordination Agreement Between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of Environmental Protection, or Duly Authorized Designee, State Programmatic General Permit', Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water Act. Your proposed activity as outlined on your notice and attached drawings does not qualify for Federal authorization pursuant to the State Programmatic General Permit and a SEPARATE permit or authorization may be required from the Corps. A copy of your permit application has been forwarded to the Corps for their review. The Corps will issue their authorization directly to you or contact you if additional information is needed. If you have not heard from the Corps within 30 days from the date your application was received at the local FDEP Office, contact the Corps at the Palm Beach Gardens Regulatory Field Office at (561) 472-3530, for status and further information. Failure to obtain Corps authorization prior to construction could subject you to federal enforcement action by that agency. Additional Information This letter does not relieve you from the responsibility of obtaining other federal, state, or local authorizations that may be required for the activity. Please retain this letter. The activities may be inspected by authorized state personnel in the future to insure compliance with appropriate statutes and administrative codes. If the activities are not in compliance, you may be subject to penalties under Chapter 373, F.S., and Chapter 18-14, F.A.C. If you have any questions, please contact Cindy Lott at (772) 467-5560 or by email at cynthia.lott@deo.state.fl.us. When referring to your project, please use the FDEP file name and number listed above. Executed in Palm Beach County, Florida. it 1100M)79, ,, File No.: 56-0325514-001 File Name: Winschel. Paul Page 3 of 3 STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTIOP _ )I bIH Katy Collins Environmental Administrator Submerged Lands and Environmental Resource Program Enclosures: Notice of Rights Attachment A- Specific Exemption Rule Attachment B- Newspaper Publication Special Conditions for use of the SPGP Conditions Project Drawings, 7 pages Copies furnished to: USACOE Palm Beach Gardens, FDEP-SP@usace.armv.mil Linda Petz, Environmental Consulting, LLC, linenviron@yahoo.com (agent) FILING AND ACKNOWLEDGMENT FILED, on this date, pursuant to 120.52(9), Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged. l�1Li't' 1i: Y i f NOTICE OF RIGHTS This action is final and effective on the date filed with the Clerk of the Department unless a petition for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not be final and effective until further order of the Department. Because the administrative hearing process is designed to formulate final agency action, the filing of a petition means that the Department's final action may be different from the position taken by it in this notice. Petition for Administrative Hearing A person whose substantial interests are affected by the Department's action may petition for an administrative proceeding (hearing) under Sections 120.569 and 120.57, F.S. Pursuant to Rule 28- 106.201, F.A.C., a petition for an administrative hearing must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any email address, any facsimile number, and telephone number of the petitioner; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts that the petitioner contends warrant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. The petition must be filed (received by the Clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the time of filing. Time Period for Filing a Petition In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the applicant must be filed within 21 days of receipt of this written notice. Petitions filed by any persons other than the applicant, and other than those entitled to written notice under Section 120.60(3), F.S. must be filed within 21 days of publication of the notice or within 21 days of receipt of the written notice, whichever occurs fast. Under Section 120.60(3), F.S., however, any person who has asked the Department for notice of agency action may file a petition within 21 days of receipt of such notice, regardless of the date of publication. The failure to file a petition within the appropriate time period shall constitute a waiver of that person's right to request an administrative determination (hearing) under Sections 120.569 and 120.57, F.S., or to intervene in this proceeding and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another party) will be only at the discretion of the presiding officer upon the filing of a motion in compliance with Rule 28-106.205, F.A.C. Extension of Time Under Rule 62-110.106(4), F.A.C., a person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, before the applicable deadline for filing a petition for an administrative hearing. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon. Mediation Mediation is not available in this proceeding. Judicial Review Any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by filing a Notice of Appeal pursuant to Rules 9.110 and 9.190, Florida Rules of Appellate Procedure, with the Clerk of the Department in the Office of General Counsel, 3900 Commonwealth Boulevard, M.S. 35, Tallahassee, Florida 32399-3000; and by filing a copy of the Notice of Appeal accompanied by the applicable filing fees with the appropriate District Court of Appeal. The Notice of Appeal must be filed within 30 days from the date this action is filed with the Clerk of the Department. Attachment A Chapter 62-330.051 Exempt Activities. The activities meeting the limitations and restrictions below are exempt from permitting. However, if located in, on, or over state-owned submerged lands, they are subject to a separate authorization under Chapters 253 and 258, F.S., and Chapters 18-18, 18-20, and 18-21, F.A.C., as applicable. (12) Construction, Restoration, Enhancement, and Repair of Seawall, Riprap, and Other Shoreline Stabilization— (b) The restoration of a seawall or riprap under Section 403.813(1)(e), F.S., where: 1. The seawall or riprap has been damaged or destroyed within the last year by a discrete event, such as a storm, flood, accident, or fire or where the seawall or rip rap restoration or repair involves only minimal backfilling to level the land directly associated with the restoration or repair and does not involve land reclamation as the primary project purpose, as further explained in section 3.2.4 of Volume I; 2. Restoration shall be no more than 18 inches waterward of its previous location, as measured from the waterward face of the existing seawall to the face of the restored seawall, or from the waterward slope of the existing riprap to the waterward slope of the restored riprap; (d) Installation of batter or king piles used exclusively to stabilize and repair seawalls, provided they do not impede navigation. t Attachment B STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION NOTICE OF DETERMINATION OF EXEMPTION File No.: 43-0325514-001 The Department of Environmental Protection gives notice that the project to repair and replace an approximate 43 linear feet of seawall within a maximum of 18-inches waterward of the existing wall (measured wetface to wetface), including a 28 inch concrete cap and a maximum of seven king piles and seven batter piles, has been determined to be exempt from requirements to obtain an Environmental Resource Permit. The project is located within a manmade canal off the Indian River, Class III Waters of the State, adjacent to 10701 South Ocean Drive Lot 676, Jensen Beach (Section 11, Township 37 South, Range 41 East), in St. Lucie County (27- 16' 04.99" North Latitude, 800 12' 29.76" West Longitude). A person whose substantial interests are affected by the Department's action may petition for an administrative proceeding (hearing) under sections 120.569 and 120.57 of the Florida Statutes. The petition must contain the information set forth below and must be filed (received by the clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Mediation is not available. If a timely and sufficient petition for an administrative hearing is filed, other persons whose substantial interests will be affected by the outcome of the administrative process have the right to petition to intervene in the proceeding. Intervention will be permitted only at the discretion of the presiding officer upon the filing of a motion in compliance with rule 28-106.205 of the Florida Administrative Code. hi accordance with rule 62-110.106(3), F.A.C., petitions for an administrative hearing must be filed within 21 days of publication of the notice or receipt of written notice, whichever occurs first. Under rate 62-110.106(4) of the Florida Administrative Code, a person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition form administrative hearing. The Department my, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000 prior to the applicable deadline. A timely request for extension of time shall toll the maning of the time period for filing a petition until the request is acted upon. Upon motion by the requesting party showing that the failure to file a request for an extension of time before the deadline was the result of excusable neglect, the Department may also grant the requested extension of time. The petitioner shall mail a copy of the petition to the applicant at the address indicated above at the time of filing. The failure of any person to file a petition for an administrative hearing within the appropriate time period shall constitute a waiver of that right. A petition that disputes the material facts on which the Department's action is based must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The time, address, and telephone number of the petitioner; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency derision; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts the petitioner contends warant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. A petition that does not dispute the material facts on which the Department's action is based shall state that no such facts are in dispute and otherwise shall contain the same information as set forth above, as required by mle 28-106.301. Under sections 120.569(2)(c) and (d) of the Florida Statutes, a petition for administrative hearing shall be dismissed by the agency if the petition does not substantially comply with the above requirements or is untimely filed. Complete copies of all documents relating to this determination of exemption are available for public inspection during normal business hours, 8:00 a.m. to 5:00 p.m., Monday through Friday, at the Southeast District office, 400 North Congress Avenue, 3rd Floor, West Palm Beach, Florida 33401. t L bing Maps 10701 S Ocean Dr, Jensen Beach, FL 34957 Winschel Property Lot 676 a On the y09 Use m.bing.com ® ^rcectians, businesses. and rr 1 iN T 4� 04t, Q� Park 4, 56-0325514 DD1 my 1M ns<hel, Paul , Eder ND ,x 0 #dew H ReeaLdrmlace3In. ft seawall '` - •. �'tA4m. Mav 16. 2014 vl ".✓ sY: C EPaff F North River J Shem Qy ShOres R Waterbody: Artificial canal off of the Indian Wver Width: varies w/ min.100'+/- EXISTING WINSCHEL PROPERTY 10701 S. Ocean Drive, #676 Jensen Beach, FL 34957 Winschel Proposed Seawall LCTVIG, NT 0 A 25514.OD1schel, Paulde canal431a R scawall6, 2014CEL'oKPROPOSED2 of 3 ��Max.7kingibatterpiles 1 Y Min. 3 kingibatter piles MHW/MLW Pile (10-+/- OC) Proposed Concrete Seawall win 1ti" face Q10.. to face INN9�. Existing 11rlieatterPile (10'+/-OC) :cncrete—� (Angled4:1+/-, Seawall @ panel midpoint) Wilco Construction, Inc. I Date: 3/29/14 (772)460-6928; FAX(772)460-6929 NOTE: I. Concrete to have a min. Compressive Strength of 5003 psi @ 20 days. 2. Install new concrete seawall directly In from of ealstlng seawall, within 1' face to feet. 3. Into.:3 ea better plies. 3 as king piles; mat: 7 ea better piles, 7 as king plan; 4. PBings final hemmer driven to a into. of a tons each 0. Plfinga to be 12'02' prestressed concrete up to 20' langttt• r UfUrc Hooks as Bar He and Winschel Residence 10701 S. Ocean Dr, Lot 676 Jensen Beach, FL 34957 qEN,T G 14P DuDl1- sAD4 Whel 44 Marmalade canal Renai&eolace431rt ft seawall z one: May 16, 2D34 ' I Sheen 43 Ties or O.C. New Concrem Parel 1 (6' Nick s 117 Wide a 1r long)__ King Pile 1rk12' prestressed (Vertical at pare) aearre) Becldvl Betxeen Fx[Mng Wall 8 New Wall / Panels (657pea rorP� L1 penetratron for pllkgs u <,B' (bee to face) rk1) 43'+/- New Concrete Cap/Wall C* Panej fag pilot panel learn (vertical) Rebar g3 Reba 5 pTies 7 OC ZB/aver Pilo ® priest midpoint (ogled 4:10.) Expanded ' King Pile :rate ebor 8"+/ mbar 1 _V i-N3lobar 141 671y- 'r • tookepory- 'klPgng r:' . set min. embeds f Coo. PII 6' 2Ile. per pile Expanded BOTTOM Batter Pile _ bar " rebar a5 rebuffes @roc4 rte POings14 (12"X dowel with old. .,book epozy- eoler .+. set min. embedmerx. P '�. • S 2 a. per pile Oeotastlls FIOer Cloth along backside (landward side) of wall scam Cros New Seawall Wilco Construction, Inc. Date: 3/29/14 Section for the Winschel Residence (772)460-6928; Fax (772)460-6929 scale: Dim DEPARTMENT OF THE ARMY JACKSONVILLE DISTRICT CORPS OF ENGINEERS 4400 PGA Boulevard, Suite 500 Palm Beach Gardens, Florida 33410 REPLY TO July 28, 2015 ArTEmmN OF Regulatory Division Palm Beach Gardens Section SAJ-2014-01019(N W-PW B) Paul Winschel 10701 S. Ocean Drive Lot 676 Jensen Beach, Florida 34957 Dear Mr. Winschel: The U.S. Army Corps of Engineers (Corps) assigned your application for a Department of the Army permit, which the Corps received on April 14, 2014, the file number SAJ-2014-01019(NW-PWB). A review of the information and drawings provided indicates that the proposed work would result in repair to an existing 43 linear foot seawall by replacing 4 batter piles, 6 king piles and installing 43 feet of new concrete seawall within 18 inches of the existing seawall and installing a new 48 inch wide cap over the existing 20 inch wide cap. The project would affect waters of the United States associated with the Indian River Lagoon adjacent to 10701 S. Ocean Drive Lot 676 in Section 11, Township 37 South, Range 41 East, Jensen Beach, Saint Lucie County, Florida. Your project, as depicted on the enclosed drawings (Attachment A), is authorized by Nationwide Permit (NWP) Number 13. In addition, project specific conditions have been enclosed. This verification is valid until March 18, 2017. Furthermore, if you commence or are under contract to commence this activity before the date that the relevant nationwide permit is modified or revoked, you will have 12 months from the date of the modification or revocation of the NWP to complete the activity under the present terms and conditions of this nationwide permit. Please access the U.S. Army Corps of Engineers' (Corps) Jacksonville District's Regulatory Internet page to access Internet links to view the Final Nationwide Permits, Federal Register Vol. 77, dated February 21, 2012, specifically pages 10270—10290, the Corrections to the Final Nationwide Permits, Federal Register 77, March 19, 2012, and the List of Regional Conditions. The Internet page address is: hftr)://www.sai.usace.army.mil/Missions/Regulato[y.asi)x Please be aware this Internet address is case sensitive and should be entered as it appears above. Once there you will need to click on "Source Book'; and, then click on "Nationwide Permits." These files contain the description of the Nationwide Permit authorization, the Nationwide Permit general conditions, and the regional conditions, which apply specifically to this verification for NWP 13. Enclosed is a list of the six -2- General Conditions, which apply to all Department of the Army authorizations. You must comply with all of the special and general conditions and any project specific condition of this authorization or you may be subject to enforcement action. In the event you have not completed construction of your project within the specified time limit, a separate application or re -verification may be required. The following special conditions are included with this verification: 1. Self -Certification Statement of Compliance: Within 60 days of completion of the work authorized, the Self -Certification Statement of Compliance (Attachment B) must be completed and submitted to the U.S. Army Corps of Engineers. Email the completed form to: CESAJ-ComplyDocs(a)usace.army. mil or mail the completed form to the Regulatory Division, Special Projects and Enforcement Branch, 4400 PGA Boulevard, Suite 500, Palm Beach Gardens, Florida 33410. 2. Assurance of Navigation and Maintenance: The Permittee understands and agrees that, if future operations by the United States require the removal, relocation, or other alteration, of the structures or work herein authorized, or if, in the opinion of the Secretary of the Army or his authorized representative, said structure or work shall cause unreasonable obstruction to the free navigation of the navigable waters, the Permittee will be required, upon due notice from the U.S. Army Corps of Engineers, to remove, relocate, or alter the structural work or obstructions caused thereby, without expense to the United States. No claim shall be made against the United States on account of any such removal or alteration. 3. Manatee Conditions: The Permittee shall comply with the enclosed (Attachment C) "Standard Manatee Conditions for In -Water Work — 2011 " 4. Sea Turtle and Smalltooth Sawfish Conditions: The Permittee shall comply with National Marine Fisheries Service's (Attachment D) "Sea Turtle and Smalltooth Sawfish Construction Conditions" dated March 23, 2006. 5. Incidents where Johnson's seagrass, or any individuals of whale, sea turtle, sturgeon, sawfish, coral, or other species listed by NOAA Fisheries under the Endangered Species Act appear to be injured or killed as a result of discharges of dredged or fill material into waters of the United States or structures or work in navigable waters of the United States authorized by this NWP shall be reported to NOAA Fisheries, Office of Protected Resources at (301) 713-1401 and the Regulatory Office of the Jacksonville District of the U.S. Army Corps of Engineers at 904-232-1177. The finder should leave the plant or animal alone, make note of any circumstances likely causing the death or injury, note the location and number of individuals involved -3- and, if possible, take photographs. Adult animals should not be disturbed unless circumstances arise where they are obviously injured or killed by discharge exposure, or some unnatural cause. The finder may be asked to carry out instructions provided by NOAA Fisheries, Office of Protected Resources, to collect specimens or take other measures to ensure that evidence intrinsic to the specimen is preserved. 6. Clean Fill: A condition is included to require that clean fill must consist of suitable material, clean and free from toxic pollutants in accordance with Section 307 of the Clean Water Act. 7. Turbidity Barriers: Prior to the initiation of any of the work authorized by this permit, the Permittee shall install floating turbidity barriers with weighted skirts that extend to within one foot of the bottom around all work areas that are in, or adjacent to, surface waters. The turbidity barriers shall remain in place and be maintained until the authorized work has been completed and all erodible materials have been stabilized. 8. Cultural Resources/Historic Properties: a. No structure or work shall adversely affect, impact, or disturb properties listed in the National Register of Historic Places (NRHP) or those eligible for inclusion in the NRHP. b. If during the ground disturbing activities and construction work within the permit area, there are archaeological/cultural materials encountered which were not the subject of a previous cultural resources assessment survey (and which shall include, but not be limited to: pottery, modified shell, flora, fauna, human remains, ceramics, stone tools or metal implements, dugout canoes, evidence of structures or any other physical remains that could be associated with Native American cultures or early colonial or American settlement), the Permittee shall immediately stop all work in the vicinity and notify the Corps. The Corps shall then notify the Florida State Historic Preservation Officer (SHPO) and the appropriate Tribal Historic Preservation Officer(s) (THPO(s)) to assess the significance of the discovery and devise appropriate actions. c. A cultural resources assessment may be required of the permit area, if deemed necessary by the SHPO, THPO(s), or Corps, in accordance with 36 CFR 800 or 33 CFR 325, Appendix C (5). Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume on non-federal lands without written authorization from the SHPO and the Corps. d. In the unlikely event that unmarked human remains are identified on non-federal lands, they will be treated in accordance with Section 872.05 Florida Statutes. All work in the vicinity shall immediately cease and the Permittee shall immediately notify the medical examiner, Corps, and State Archeologist. The Corps shall then notify the appropriate SHPO and THPO(s). Based, on the circumstances of the discovery, equity 4Z -4- to all parties, and considerations of the public interest, the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. Such activity shall not resume without written authorization from the State Archeologist, SHPO, and the Corps. This letter of authorization does not obviate the necessity to obtain any other Federal, State, or local permits, which may be required. Prior to the initiation of any construction, projects qualifying for this Nationwide permit must qualify for an exemption under section 403.813(1), Florida Statutes or 373.406, Florida Statutes, or otherwise be authorized by the applicable permit required under Part IV of Chapter 373, Florida Statutes, by the Department of Environmental Protection, a water management district under section 373.069, Florida Statutes, or a local government with delegated authority under section 373.441, Florida Statutes, and receive Water Quality Certification and applicable Coastal Zone Consistency Concurrence or waiver thereto, as well as any authorizations required for the use of state-owned submerged lands under Chapter 253, Florida Statutes, and, as applicable, Chapter 258, Florida Statutes. You should check State -permitting requirements with the Florida Department of Environmental Protection or the appropriate water management district. This letter of authorization does not include conditions that would prevent the 'take' of a state -listed fish or wildlife species. These species are protected under sec. 379.411, Florida Statutes, and listed under Rule 68A-27, Florida Administrative Code. With regard to fish and wildlife species designated as species of special concern or threatened by the State of Florida, you are responsible for coordinating directly with the Florida Fish and Wildlife Conservation Commission (FWC). You can visit the FWC license and permitting webpage(hftp://www.mvfwc.com/license/Viildlife for more information, including a list of those fish and wildlife species designated as species of special concern or threatened. The Florida Natural Areas Inventory (http://www.fnai.orgn also maintains updated lists, by county, of documented occurrences of those species. This letter of authorization does not give absolute Federal authority to perform the work as specified on your application. The proposed work may be subject to local building restrictions mandated by the National Flood Insurance Program. You should contact your local office that issues building permits to determine if your site is located in a flood -prone area, and if you must comply with the local building requirements mandated by the National Flood Insurance Program. If you are unable to access the intemet or require a hardcopy of any of the conditions, limitations, or expiration date for the above referenced NWP, please contact me by telephone at 561-472-3532. F c5 yy 4� 'tay L�^WKK" -5- Thank you for your cooperation with our permit program. The Corps Jacksonville District Regulatory Division is committed to improving service to our customers. We strive to perform our duty in a friendly and timely manner while working to preserve our environment. We invite you to complete our automated Customer Service Survey at http://corpsmapu.usace.army.mil/cm_apex/f?p=regulator"urvey. Please be aware this Internet address is case sensitive; and, you will need to enter it exactly as it appears above. Your input is appreciated — favorable or otherwise. Sincerely, Yam-,,... o 4,� Paula Bratschi Project Manager Enclosures Attachment A: Drawings Attachment B: Self -Certification Statement of Compliance Attachment C: "Standard manatee Conditions for In -Water work — 2011" Attachment D: "Sea Turtle and Smalltooth Sawfish Construction Conditions," dated March 23, 2006 Copies Furnished: IinenvironCawahoo. com CESAJ-RD-PE y `f GENERAL CONDITIONS 33 CFR PART 320-330 1. The time limit for completing the work authorized ends on March 18, 2017. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and state coordination required to determine if the remains warrant a recovery effort of if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit you must obtain the signature of the new owner in the space provided and forward a copy of the permit to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your project, you must comply with the conditions specified in the certification as special conditions to this permit. For your convenience, a copy of the certification is attached if it contains such conditions. 6. You must allow a representative from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit. t), bing Maps 107018 Ocean Dr, Jensen Beach, FL 34957 Winschel Property Lot 676 ® On the go? Use m.bing.eom to find maps, ciredtim, businesses. and mare rl- l fry r� -r . �T. N 4 AytSv L . ' lot' A+IA 1140 Am! W[%i z. - n- y j Waterbody: Artificial canal off of the Indian River Width: varies w/ min. 100'+/- EXISTING WINSCHEL PROPERTY 10701 S. Ocean Drive, #676 Jensen Beach, FL 34957 PROPOSED Max. 7 kingibatter plies Min. 3 kingibatter piles (V "--King Pile (10'+/- OC) Proposed Concrete q ao Seawall Win 18" face !,111&0 A� 5?qm to face mum Existing �9atter Pile (10'+1- OC) :oncrete It (Angled 4:1+/-, Seawall @ panel midpoint) Plan Winschel Proposed Seawall Wilco Construction, Inc. Date: 3/29/14 View I I (772)460-6928;FAX(772)460-6929 NOTE: 1. Concrete to have a min. Compressive Strength of 5000 psi @ 28 days. 2. Install new concrete seawall directly In front of existing seawall, within I'lace to fam g. min.: J we batter piles, 0 as king piles; maa.: 7 ea batter piles, 7 as king piles 4. Pilings final horrmer driven to a min. of d tons each 5. Pilings to be 12"M" prestressed concrete up to 20' length. rllNrg Hooks N5 Winschel Residence 10701 S. Ocean Or, Lot 676 Jensen Beach, FL 34957 IKi Ties 4'xsar Gz oc Car New Concrete Panel (8'thlck x l(Y wide x 121ang) 4•'1- King Pile UNIT prestressed Iter PI (vertical at pmwl eeanm) BackNl Between Existing Wall B New Wall Panels(057 pea 1 rock 1 T Min. 9'+/- mE� rorP rel� + min. penetration for pilings u <te (fam to face) 2'x1: 43'+/" New Concrete Cap/Wall 2J+/- King pile® 5pCs. N3 Rebar panel seem Ties (vemkal) 2' OC ® panel midp (angled 4:144-) Expanded iew min. 3' King Pile rcrele stage verrebar rl Da. 8 +/— s5 mbar mbertlea 14" ": @TOG �iJ„ dowel with eld. .,'v: hook epoxy- 125n1TWall ,Cr, set min. embedme Cone. Pile • S• 2 pc. per pile Expanded Batter Pile ver rebar 811+/— \ JS rebar rebar U. 14" W�cc is Pilings •};, 5dowel with aid. ♦• hook epoxy- 1Tx1T Batter ., set min. embedme Cone. P e' 2 pc. per plle/ Oeotextile Filter y;« Cloth along backside (landward side) of wall Cross New Seawall Wilco Construction, Inc. Date: 3/29/14 section for the Winschel Residence (772)460-6928; Fax (772)460-6929 Scale: _ Dim Winschel Residence 10701 S. Ocean Dr, Lot 676 Jensen Beach, FL 34957 s° .,:..- 4" y 4n �t\.It 4"t :\ 12' roposed Seawall Ddstln :;, Cap Seawall 'y Cap m m a rn 4 a d 0 O a 2 (. m <18" panel to panel face Enlarged New Seawall Wilco Construction, Inc. Cross for the Winschel Residence (772)460-6928; Fax (772)460-6929 Date: 5/8/14 Scale: Dim SELF -CERTIFICATION STATEMENT OF COMPLIANCE NW-13 Permit Number: SAJ-2014-01019(NW-PWB) Permittee's Name & Address (please print or Telephone Number: Location of the Work: Date Work Started: Date Work Completed: PROPERTY IS INACCESSIBLE WITHOUT PRIOR NOTIFICATION: YES NO TO SCHEDULE AN INSPECTION PLEASE CONTACT AT Description of the Work (e.g. bank stabilization, residential or commercial filling, docks, dredging, etc.): Acreage or Square Feet of Impacts to Waters of the United States: Describe Mitigation completed (if applicable): Describe any Deviations from Permit (attach drawing(s) depicting the deviations): I certify that all work and mitigation (if applicable) was done in accordance with the limitations and conditions as described in the permit. Any deviations as described above are depicted on the attached drawing(s). Signature of Permittee � za STANDARD MANATEE CONDITIONS FOR IN -WATER WORK 2011 The permittee shall comply with the following conditions intended to protect manatees from direct project effects: a. All personnel associated with the project shall be instructed about the presence of manatees and manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing manatees which are protected under the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee Sanctuary Act. b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake" at all times while in the immediate area and while in water where the draft of the vessel provides less than a four -foot clearance from the bottom. All vessels will follow routes of deep water whenever possible. C. Siltation or turbidity barriers shall be made of material in which manatees cannot become entangled, shall be properly secured, and shall be regularly monitored to avoid manatee entanglement or entrapment. Barriers must not impede manatee movement. d. All on -site project personnel are responsible for observing water -related activities for the presence of manatee(s). All in -water operations, including vessels, must be shutdown if a manatee(s) comes within 50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation. Animals must not be herded away or harassed into leaving. e. Any collision with or injury to a manatee shall be reported immediately to the Florida Fish and Wildlife Conservation Commission (FWC) Hotline at 1-888-404-3922. Collision and/or injury should also be reported to the U.S. Fish and Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south Florida, and to FWC at I moedledSoeciesOmyFWC.com Temporary signs concerning manatees shall be posted prior to and during all in -water project activities. All signs are to be removed by the permittee upon completion of the project. Temporary signs that have already been approved for this use by the FWC must be used. One sign which reads Caution: Boaters must be posted. A second sign measuring at least 8'W by 11" explaining the requirements for "Idle Speed/No Wake" and the shut down of in -water operations must be posted in a location prominently visible to all personnel engaged in water -related activities. These signs can be viewed at MyFWC.com/manatee. Questions concerning these signs can be sent to the email address listed above. a CAUTION; MANATEE HABITAT All pleoject Vessels IDLE SPEED/ NO WAKE When a, manatee is within 50 feet of' work all in -water activities must SHUT DOWN Report any calli-sJon" with, or,inj.ur.y to ,a, ma'natez: Wi - Idlife Alert: 1-888-404-FWCC'(3922) :cell *FWC--..--or #FWC Ot�FyT ar4 °, *%CBOT UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration NATIONAL MARINE FISHERIES SERVICE Southeast Regional Office 263 13th Avenue South St. Petersburg, FL 33701 SEA TURTLE AND SMALLTOOTH SAWFISH CONSTRUCTION CONDITIONS The permittee shall comply with the following protected species construction conditions: a. The permittee shall instruct all personnel associated with the project of the potential presence of these species and the need to avoid collisions with sea turtles and smalltooth sawfish. All construction personnel are responsible for observing water -related activities for the presence of these species. b. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing sea turtles or smalltooth sawfish, which are protected under the Endangered Species Act of 1973. c. Siltation barriers shall be made of material in which a sea turtle or smalltooth sawfish cannot become entangled, be properly secured, and be regularly monitored to avoid protected species entrapment. Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated critical habitat without prior agreement from the National Marine Fisheries Service's Protected Resources Division, St. Petersburg, Florida. d. All vessels associated with the construction project shall operate at "no wake/idle" speeds at all times while in the construction area and while in water depths where the draft of the vessel provides less than a four -foot clearance from the bottom. All vessels will preferentially follow deep -water routes (e.g., marked channels) whenever possible. e. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily construction/dredging operation or vessel movement, all appropriate precautions shall be implemented to ensure its protection. These precautions shall include cessation of operation of any moving equipment closer than 50 feet of a sea turtle or smalltooth sawfish. Operation of any mechanical construction equipment shall cease immediately if a sea turtle or smalltooth sawfish is seen within a 50-ft radius of the equipment. Activities may not resume until the protected species has departed the project area of its own volition. f. Any collision with and/or injury to a sea turtle or smalltooth sawfish shall be reported immediately to the National Marine Fisheries Service's Protected Resources Division (727-824- 5312) and the local authorized sea turtle stranding/rescue organization. g. Any special construction conditions, required of your specific project, outside these general conditions, if applicable, will be addressed in the primary consultation. Revised: March 23, 2006 O:\forms\Sea Turtle and Smalltooth Sawfish Construction Conditions.doc noon .f DEPARTMENT OF THE ARMY PERMIT TRANSFER REQUEST PERMIT NUMBER: SAJ-2014-01019(NW-PWB) When the structures or work authorized by this permit are still in existence at the time the property is transferred, the terms and conditions of this permit will continue to be binding on the new owner(s) of the property. Although the construction period for works To validate the transfer of this permit and the associated responsibilities associated with compliance with its terms and conditions, have the transferee sign and date below and mail to the U.S. Army Corps of Engineers, Enforcement Section, Post Office Box 4970, Jacksonville, FL 32232-0019. (TRANSFEREE -SIGNATURE) (DATE) (NAME -PRINTED) (MAILING ADDRESS) (CITY, STATE, ZIP CODE (SUBDIVISION) (LOT) (BLOCK) (STREET ADDRESS) NN O Waterbody: Artificial canal off of the Indian River Width: varies wl min. 10041- EXISTING WINSCHEL PROPERTY 10701 S. Ocean Drive, #676 Jensen Beach, FL 34957 Plan I Winschel Proposed Seawall View 41\tAENT O C QP 560325%41 Wl LC+ 4Q ra: Winashel, Paul 7 M=ndc canal 4 Reaairheolace43 ]hi ft seawall � 7. p o.re: May16, 2014 PROPOSED �a sheen 2of3 Max. 7 kingibatter piles 04 Min. 3 kingibatter piles MHW/MLW King Pile Proposed Concrete Seawall w1in 18" face °e �e+� �ito face 'oi a,. Existing 9atterPile (10'+1-OC) ,oncrote�� (Angled 4:1+1-, Seawall @ panel midpoint) P.E. 1402 Fort l Wilco Construction, Inc. (772)460-6928;FAX(772)460-6929 \\\\11111 @P�l REfzrzt lo. 72451 rt�, STATE OF Date: 3/29/14 NOTE: I. Concrete to have a min. Compressive Strength of 6000 psi ® 26 days. 2. Install new concrete seawall directly in front of existing seawall, within Vista to face 3. min.:3 as batlar plies, 3 as king plies: max.: 7 ea batter piles, 7 as king piles 4. PlUngetlnal hammerddven to a min. of 6'tons each 5. Pilings to be 12"x12" prestressed concrete up to 20'tength. III Hoolm New Concrete (3" thick x 10' wide x 12' Icrg)� King Pile 1702' 05 Bar 1' O.C. prestressed Horizonhl t (Vertical atpanel sesms)— and Vertical Backed Between Existing Wall 8 New Wall Panels (#57 pea rock), C Concrete Petrel Min. V+/- j 1 t Winschel Residence:.. ' 10701 6, Ocean Or, Lot 676 Jensen Beach, FL 34957 2 5 Rabat Ing plle@ 5 PCs. panel seam • (vertical) Cross New Seawall Section for the Winschel Residence �,�MENT C) ,QP 5G0325514-001 �C+ Cq rm: Winschel,-Paul 4 Marinade coral G Reoaidreolace43 ]n. ft aeavall Z O 0 Dare: May 16, 2014 } \� ax:CLoi?y/ J shsen y pcs #3TIe9 05c8sw 4^x @2'O.C.� / Cap Pile eomm 50% min. Penetration for Pilings I I �Iw(/eca to face) 2N12" Concrete Pilings 43'+/- New Concrete Cap/Wall 3aelextile Filter Cloth along backeldo (land aide) ofwall V mil• r3nClF Hill Expanded view King Pile onebar rerrebar 81t+�� PCs 95 M6 3 reentries r142' OC .Y dowel with std. hook epoxy - n; set min. embedme at Cone. Pill 6" 2 Po. per Pile Expanded m .3" Batter Pile c erele ...mile vet robs II Pea. 8 +% 05 rebar rebarriee 14" ®2' oC •�;,` 5dowel with old. hook epoxy- 12kt2'Batler ` eat min. embedmr Conc. Pile `' m 2 pe. per piille/ i #3 Reba Ingplie@ Ties panel seem Dan a - a 2' OC (vertical) P.E. # attar Pik panel midpoint (angled 4:1+1.) 1402 Haft Fort Plasm Wilco Construction, Inc. (772)460-6928; Fax (772)460-6929 No. Scale: Dim rd