Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSr , ALL APPLICA LE INFO M ST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: SCANNED Permit Number: BY St. Lucie County o r Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 phone: (772) 462-1553 Fax: (772) 462-1578 Commercial L RECE0 - , AUG-QV2015 Public Works St. Lucie Count, -L Residential PERMIT APPLICATION FOR: Roof IIII I•}PROP,QSED'IMPROVEMENT LOCATION::. Address: 5210 Citrus Ave, Fort Pierce, FL 34982 Legal Description: KERR ADDITION TO WHITE CITY LOTS1, 2, 3, 4 AND 5 (0.34 AC) (OR 3768-1873) Property Tax ID #: 3404-802-0001-000-8 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: ,DETAILEb DESCRIPTION.OF WORK Reroof- Tear off existing file roofing and install new file roofing, tear off existing modified bitumen roofing and install new modified Bitumen roofing. Tile Roof Pitch- 5/12. Flat Roof Pitch-1/8 / 12 John Mansville (Modified Bitumen) Product Approval - FL1646-R7 Boral Roofing (Underlayment) Product Approval- FL14317-R6 Boral Roofing (Roof Tiles) Product Approval - FL7949-RB CON STRUCTION. INFORMAT,,10N IjHVAC LJ Gas Tank 13 Electric 0 Plumbing Total Sq. Ft of Construction: 3680 Cost of Construction: $ 21,050 Piping Shutters ❑ Windows/Doors nklers Generator 11 Roof S Ft. of First Floor: Utilities:nSewer Septic Building Height: OWNERJLESSEE:'` CONTRACTOR y Name Charles B Connolly & Carrnela Barbour Name: Michael Miller Address: 6210 Citrus Ave Company: Trade Winds Roofing, Inc. City: Fort Pierce state: FL Zip Code: 34982 Fax: Phone No. 772-878-1814 Address: P.O. Box 13208 City: Fort Pierce State: FL Zip Code: 34979 Fax: 7723-466-9725 Phone No. 772-466-9420 E-Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) E-Mail: mike@tradew(indsroofing.com State or County License: CC C057399 M if value of construction is $2500 or more, a RECORDED Notice of Commencement is required. II MiChavh ok'4il - -1�a 41LO) g� a. ' I �v ISUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:, III Name: Address: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: _ Address: City: Zip: Phone: I Zip: I certify that no work or installation has commenced prior to the issuance of a permit MORTGAGE COMPANY: _ Not Applicable Name: Address: City: Zip: Phone: BONDING COMPANY: Name: Address: Phone: _Not Applicable St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first in lion. If you intend to obtain financing, consult with lender or an attorney before commencinp,wo r recordine vour Notice of Commencement. _ Signature of Owner/ Lessee/Agent STATE OF FLORIDA STATE OF FLO IDp COUNTY OF S'f' • I 1 .I Cr I � COUNTY OF—F L (QCf The forgoing instrument was acknowledged before me this a0 day of4- 20 1 Sby r Ina t.1J '(II ( me of person acknowledging) 4VI-1 L6 Jim (Signature of Notary Public tate of Flocda ) Personally Known Q/ OR Produced Identification Type of Identification Produced -n�,,FELICIA LYNE Commission No. A& YPUBUC Revised 07/15/2014 The rf�orgoing ins ument was acknowledged before me thisd-0 day ot, 20 by (Name of person ac nowledging ) of Notary Public Siate of Personally Known OR Produced Identification Type of Identification Produced UCIA LYNE GMME Commission No. FE5aa41nova m1 V OF FLORIDA Expires 9/4/2017 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS NOTICE OF COMMENCEMENT Permit No. Tax Folio No, 3404-802-0001-000-8 State of Florida County of St Wde The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement Legal Description of Property: (and street address if available): 5210 CITRUS AVE, FORT PIERCE, FL 34982 KERR ADDITION TO WHITE CITY LOTS1, 2, 3,4 AND 5 (0.34 AC) (OR 3728-2197) General description of Improvementsero_of Owner information or Lessee f ormation if th Less m om Ooof A _ L%e QT,'Rack CU^ ouName pym �l _ pO aAddress r.x -, Interest in property: tf. n P:r S m Name and address of fee simple titleholder (if different from Owner listed above): ,�„ rn N Contractors Name- Trade Winds Roofing Inc. o m'2S M o -4 0 Contractor Address: . Box 13208, Fort Pierce FL 3 979 Phone Number. 7721E 6-9420 m� m Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ o OO Name and address: Phone number- 8 'O 1 m Lender Name: Phone Number. d 0 Z ;a Lender's address: Ci C i Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Sect o 713.13(1) (a)7., Florida Statutes: c Name: Phone Number. A Address: In addition to himself or herself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner. Expiration date of notice of commencement- (the expiration date may ootbabefore the completion of construction and final payment to the -contractor, but will be 1 year from thedate of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713. 3, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FI NANCING, CONSULT WITH YOUR -LENDER 0R AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. , Under penalty of perjury, I declare.that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. (Signature of Owner or (Signatory's Authorized Officer/Director/Partner/Manager The foregoing instrument was acknowledged before me this & day of Jam, 2D\ FELIOIA LYNE GAN1DEE NOTARY PUBLIC STATE OF FLORIDA Coy" FF051263 Eta m B/4/2017 By C'-\Cky �e.S ('�,r"acd as �Wr12_`�� for ChCIY �'eS r VLY- Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed .. %--Atj.� Personally known— orproduced IdentificationV (Signature.of Notary. Public - Sta�oddaa) L (' Syb- I (Print, Type, or Stamp Commissioned Name ofNotary -Public) Type of Identification produced-- ) *": sign in both places in front of notary I TILE BOWCERTIFICATION CARDy9 Michael Miller is a CERTIFIED INSTRUCTOR* of TILE BOND"Roof Tile Adhesive - TILE BOND' ISSUED: 7/17/15 �..._... a O*'Tr mwkofT Do Chemical Companyrpow�aranaffiluted mpanyofDrni. Ca,,o a,ehe w,v c9PPl'catav- II Sep O',p15 100'. 0a Trade Winds Roofing 772-466-9725 p.1 Planning & Development Services Building & Code Regulation Division $ 2300 Virginia Avenue s Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax:772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit#1508-0314 I, Michael Miller licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 FS. to make such on inspection. On or about 09/01/2015 I did personally inspect the roof deck nailing (Date) work at: 5210 Citrus Ave, Fort Pierce, FL 34982 (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the FI ida Existing Building Code Section 611 or the product approval submitted {whichever is most stri nt) CC C057399 Signature and Seal License # STATE OF FLORIDA COUN P(OF 'Sf. C Sworn to and subscribed before me this 1 day of =2 20� by \('ha'01 M1 I? _. Who —is known to me or who has produced may\ P.o� l 1C_rt n5F as identification. Notary Public, State oi_ Flgrida - Signature of Notary: `'-� r 1 -i O -1-A t x. ggFIEUCIA `YNE GANDEE Commission Number: (DS1,F>) 3 (S NOTARYPU9LIo STATE OF Flop DA En Ol/19f2011 O M"FF051283 Bores 9/4f2017 RFrFIVFD SFP 012015 • N Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or772-462-2172 Fax:772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 1508-0314 1, Michael Miller licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector `General, Building, Residential or Roofing Contractor or any Individual certified under 468 F.S. to make such an inspection. On or about 09/01/2015 1 did personally inspect the roof deck nailing (Date) work at: 5210 Citrus Ave, Fort Pierce, FL 34982 (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the FI rida Existing Building Code Section 611 or the product approval submitted (whichever is most stri nt) CC C057399 Signature and Seal License # STATE OF.FLORRIIDA COUNTYOF S- --Uj,C ( Sworn to and subscribed before me this ( day of 5( 5 -OVC 20L by M C.)OG -P ( ffij � � Q 12 Who is personally known tome or. who has produced -C (1CD.n as identification. Notary Public, State of FI rida p _ Signature of Notary: .X�l t A .1 A R C� f A FELICIALYNE GANDEE Commission Number: 1=�0151,OLQ3 (S NOTARY PUBLIC STATE OF FLORIDA En 01/19/2011 Cams? FR)51283 Expires 9/412017 , H STEVE CLARK ARCHITECT ALTAMONTE SPRINGS FLORIDA phone. Im. )924-5439 T2Ane /J!A40 ROor9 /V'L- fl_x:rer ���„I ZAfe1JAd1q s�LG�r>�Allc ,�:fk�,GD,•,— ^. ..1. Job Address SLR C� ArY Fi_ r�« �ep 3L`fJ's 41% G 111_a• R_-Rnr.'' ReeOver nr.�ir B JILT LAP ROOF PLAN GENERAL NOTES: _ 1. Remove rooting to the PW Decking 2.Replace damaged PW with new CDX ' 3.Re-nail entire Roof ( 6d x 2" lens h)(i- (6" OC — edge & Field. JON ) C.2. ASCU _7 X Farr 20t4 Enclosed Bldg; o. 6 / P.1rhalt" Eueiosect 3 Residential X (=wZJ Windioading: /SV' Exposure: E3 `Ilse Factor: /. C Commercial Roof Pitch: C, 2T /12 Height: < 16' ✓> 16' MBH:1 ROOF —MG SYSn.Iyr- _1A D"I6r/,6i rIAW CAI NOA: Fz lz,49 - !1'7 Zone I FL O B @ h=p0' = x x :U.AR PSF x 0.6 = --0 Y Zone �/Jci B @ WAG' = x x /!b PSFx0.6=—G9¢ a=SGX1% Zone 3 B n h y30' = s f PSF % 0.6 = - — a = — i DESIGN PRESSURE per NOA: - S2-.S' Deck Type Thickness uacFSFeet P��•��n�l�ly 2S Number of Plies 2 Fasteners Nailing Pattern ,for Base Sheet: Zone 1: (field) Lap �� 'GC # Rows 2 @ / "OC 7.one y: (per-) T—'°F 17 'OC d# RLivs /L @ "9C' r Insulation: Base Layer - Type AiIA size Type of Fasteners! Roadma Material, Number of fasteners: Zone 1 : Zone 2, Zone 3 PLY Sheet # of Plies Type of Fastener TOP Sheet APAX d S # of Plies 0,V c Type of Fastener 'lckc i A�.ti Surfacing: Smoosrl. Drip Edge: Te ,�/4"4A Material: �� 4:4 DATE: I `7 AZIt 2015' ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO 71 CE REVIEWED BY DATE PLANS AND PERMrr MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE SFni. Clit V' 476 Spanish Trace Drive 32714 :1RCf=CILRAL REGI1STW_T10hi: AR 0011463 Florida Building Code Onlin— Page 1 of 2 SOS Home Loa In userrlwomtw Hat Topics Subrnft SurOorae SUts&Fern Pubina4ons F0C Stan Gas S'PUP links S-16 Business .�. Professional � U=R PueuAper oval .�I,- - pLoevca9 eL;�u>ea?acCn�uc�N=�s:;u>>_narceLwJ:+s>Apprenon octon FL e Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Emall Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL1046-R7 Revision '2014 lw-, Prdved- Johns Manville P.O. Box 5108 Denver, CO 80217 (303)978-4379 codes@Jm.mm Vanessa Indarte-van der Plaat mdes@Jm.com R.wnug ft4odified Bitumen Roaf System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer W Evaluation Report - Hardmpy Received Florida Engineer or Architect Name who developed Robert Merriman the Evaluation Report Florida license PE-5916G Quality Assurance Entity LIL LLC Quality Assurane Contract Expiration Date 10/22/2016 Validated By John YJ. Knezevich, PE J Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and year (of Standard) Equivalence of Product Standards Certified By Sections from the Code R1046 R7 C01r2Q 15 Ol COI �J I_emiPen.pdf Standard ASTM D6164 AST14 06222 ASTM D5223 ASTM D6509 FM 4470 R1 4474 Year 2005 2008 2002 20D9 1992 2004 2004 l� http'/llvtvtv.floridabui I ding.orJpr/pr_app_dtl.aspx? param=wGE VXQivtDqudsDrIH6I48%... 7/ 15/2015 t,lor)da building Code Unlui,- . Page 2 of 2 Y Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products r i Method 1 Option D 04/29/2015 04/30/2015 05/,10/2015 06/23/2015 FL Z Model, Number or Name Description 1046.1 3ohns Manville APP Mddifled APP Modified Bitumen Roof Systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: He FL1046 R7 11 2015 04 FINAL Al ER 31•1 MODBIT APP FL1046- gZt!_df Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +H/A,1-315 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains Evaluation Reports to one specific assembly within the ER. Refer to the FL1046 R7 AE 2015 04 F1NAL_ER JH NIODBIT APP FL1046- ER Appendix for all systems and design pressure 97.Ddf limitations. 2.) Refer to ER Section 5 for Limits of Use. Created by Independent Third Party: Yes aatlt ' GR mrtert U1:: laud North Mounce etrn if Tnp 1aa,.n Ft 373W M-1 Scn.NJ-IGN TM State of rbrlda b an AA/EEO empbyec CmvrioM IDn7.7013 Stan, M nwNx •[ F—^— G[x[ mm[ :: 4ttanlhoe, Shremen[ :: Fefuntl Statement Under Florida tar; mad mlems are public remnts. If you do not went your e,mml eddy s released m response to a pu4tit-mmrds reeude, de not and 1.c m91 m Nis glory. Instead, ei oott Me pfk. by theta or by vadnlon d mML If you bave any 4uesdane, pleas, tonptt ss AS7,1395. �PusUaat to Lm 455.225(l), Herb. Statutes, eaedne Onaber1, 2012, licensees licensed under Chapter 455, F.S. hurt provide Me Mpa vad,a clth an email address if e/ have one. The emalls proeided may be used /aroMelt] communimUon pith Me Heensee. Hoverer mad addresses an, pabllt record. If you do net arbih m lya p..l address, to. Pape Ne Oepa s. ciM an caul acidnate hrh can be made available m the Wbbc To determine if you area] ..a under Chapter 455, FS., pfc on Nt4 b£$. Product Appeovall Accepaw http://NvN,vw.floridabuildina.org/pr/pr app dtl.aspx?param=ivGEVXQwtDqudsDrIH6I48%... 7/ 15/201 J RINff'Y ERR APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RE51{�91LFI_-'Qy I Table Deck Application -n—In Type Description Page 1A-1 Wood New, Remof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 1A-2 Wood New, Reraof (Tear -Off), Recover A-2 Mech. Attached Anchor 5thee t, Bonded Insulation, Bonded Roof Cover 3 1B Wood New, Reraof (Tear -Off), Recover B Mech, Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 3 SC Wood New, Reroof (Tear -Off), Recover C Mach. Armenian Insulation, uonaeo HOOT cover 1D Wood New, Reroof(Tear-Off), Recover D Prelim. Attached Insulation,Mech.AttachadlBase Sheet,,Bonded Roof Cover----,______ __ _ 4 ,a —a Kie;1'oen:;,r rTe�.:nfn^'--- -"'�'-- 'P�" "-Nen:Insuldted.Mech. Attached Base .Sheet. .Bonded .Roof .Cover, ___.. _ _ 5,- lE-2 Wood New, Reroof tTear-Off(, Recover 2A Steel or Conc. New, Reroof (Tear -Off), Recover 2B Steel or Conc. New, Reroof (Tear -Off), Recover 2C Steel or Conc. New, Reroof (Tear -Off), Recover 3A Concrete New, Reroof (Tear -Off) ition, Banded Top Insulation, Bonded Roof Bonded Roof Cover Bonded Roof Cover Bonded Roof Cover 6.10 11 12 13-14 3B Concrete - New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A-1 LWIC New, Remof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover is 4A-2 LWIC New, Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Banded Roof Cover 16-17 4B LWIC New, Reroof(Tear-Off) E Non -Insulated, Mach. Attached Base Sheet, Bonded Roof Cover 38 SA CWF New, Reroof (Tear -Off), Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19 6A Gypsum Reroof (Tear -Of) A-1 Bonded Insulation, Bonded Roof Cover 19 611 Gypsum Reroof (Tear -Off) E Non -Insulated, Mech, Attached Base Sheet, Bonded Roof Cover 19 7 Various Recover A-1 Bonded Insulation, Bonded Roof Cover 20-21 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components; deck -attachment details pertain to 'as -tested' conditions under TAS 114, Appendix J. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for Insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: > Wood Deck: UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates, Minimum 0.75-Inch plywood penetration or minimum 1-Inch wood plank embedment. Steel Deck: UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates. Minimum 0.75-Inch steel penetration and engage the top flute of the steel deck. > Concrete Deck: All Purpose Fasteners with UltraFast Metal Plates or Struct Conc. Fasteners with UltraFast Metal Plates (flat bottom only). Minimum 1-Inch embedment. Fasteners Installed with a pilot hole in accordance with the fastener manufacturer's published Installation Instructions. 3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, partite, gypsum -based roof board, Invinsa Roof Board or Invinsa Foam that meets the CIA requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. 4. Unless otherwise noted, insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application; the ribbons/heads shall expand as noted In the manufacturer's published instructions. > Hot asphalt (HA): Full coverage at 25-30lbs/square JM MBR Bonding Adhesive (MBR-BAI: Continuous 0.75-Inch wide ribbons,12-Inch O.C. or full coverage at 2.0 gal/square > Jail Two -Part Urethane Insulation Adhesive IUTA-TWO-PART): Continuous 0.75-Inch wide ribbons, 12-Inch D.C. Note: IM Green Two -Part Urethane Insulation Adhesive may be used where UTA-TI410-PART is referenced. > JM Roofing System Urethane Adhesive (RSUAI: Continuous 0.5 to 0.75-Inch wide ribbons, 12-Inch o.c. > 3M CR-20: Continuous 2.5 to 3.5-Inch ribbons, 12-Inch o.c. > Note: When multipleloyers(s) of insulation and/or coverboard are installed In ribbon -applied adhesive, adhesive ribbons sit all be staggeredfrom layer -to -layer o distance of one-half the ribbon spacing. > Note: Tire maximum edge distancefrom the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Exterior Research and Design, U.C. d/bfa Trinityl ERD Evaluation Report J9340.07.08-R4 forFLID46-R7 Certificate of Authorization d9503 Revision 4: 04/28/201S Prepared by: Robert Merriman, PE-59166 Appendix 1, Page 1 of 21 S. Unless otherwisenoted, all insulations are Rat stock or taper board of th 1111 iatmr"` ickness noted. Tapered polyisocyanurate at thefollowing thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used Cb i crease' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below maybe used as a drop -in for the equivalent thicker material listed In the table: JM Two -Part Urethane Insulation Adhesive(UTA-TWO-PART): MDP -315.0 psf (Min. 0.5-inch thick) "r 1M Roo0ng System Urethane Adhesive (RSUA): MDP .157.5 psi (Min. O.Sdnch thick) i 3M CR-20: MDP -117.5 psi (Min. 2.0-inch thick) 6. Bonded polyisacyanurate insulation boards shall be maximum 4 x 4 ft. 7, For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asteriskcarry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 8. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16, and no national analysis is permitted. 9. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparlson to the minimum requirements for the system. Testing and analysis shall be In accordance with TAS 105 orAN51/SPRI FX-1. 10. For existing substrates Ina banded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on Its awn merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPOS 1-52,,ANSI/SPRI IA-1 orTAS 124. 11. LWIC shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC Is referenced, referto current LWIC Product Approval forspedflcdeck construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum lop -coat thickness Is 2-Inches. For LWICover structural concrete, reference is made to FBC Section 1917.4.1, Point 1. 22. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Johns Manville Roof Covers Reference Layer Material Application BP -AA (Base and Ply sheets, Asphalt -Applied) Base Ply GlasBase Plus, PermaPly 28 GIasPIy IV, GIasPIy Premier, GlasBase Plus, PermaPly 28 - Hot asphalt at 2440165(square BP -CAI (Base and Ply sheets, Cold -Applied, 1-part) Base GlasBase Plus, PermaPly 28 JM MBR Cold Application Adhesive at 1.5 to 2.0 gal/square Ply GIasPIy IV, GIasPIy Premier, GlasBase Plus, PermaPly 28 APP-TA (APP, Torch -Applied) Base/Ply JM APP Base, APPeX 45 Torch applied Cap APPeX 4S,APPeX 4.5M, APPeX 4.SM IT, APPeX 4.5M FR CR, Tricor S, Tricor M FR, TrIcor M FR CR APP-CA3 (APP, Cold -Applied, l-part) Base/Ply JM APP Base JM MBR Cold Application Adhesive at 1.5 to 2.0 gal/square Cap. Tricor M FR, Tricor M FR CR APP-CA2 (APP, Cold -Applied, 2-part) Base/Ply I 1M APP Base JM MBR Bonding Adhesive at 1.5 to 2.0 gal/square Cap Tricor M FR, Tricar M FR CR 13. "MDP` = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.. Exterior Research and Design, LLC. d/b/a Tdnityl ERD Certificate of Authorization N9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report J9340.07.08-R4 for FL1046-R7 Revision 4:04/28/2015 Appendix 1, Page 2 of 21 J TRINJ-P( ERD TABLEIE-1: WOOD DECKS —NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLV ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Slip Sheet Base Sheet Roof Cover Base Fasteners Attach Ply Cap MOP (psi( No. (See Note 11 W-11 I Min. 19/32- (Optional) One or more layers j Two plies of PermaPly 32 Co., 1-5/8-inch diameter tin caps 9-Inch o.c. In 4-Inch lap and 12-Inch o.c. in (Optional) ._-.! Inch plywood PermaPly 28, loose laid below V28or Ventsulatlon I with 11 at. annular ring shank nails two, equally spaced, staggered center rows APP-TA APP-TA -52.5 TABLE 1E-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NOWINSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck SIIp Sheet Base Sheet Roof Cover Base Fasteners Attach Ply Cap MDP (psQ No. (See Note l) W 12 Min. 19/32- (Optional) One or more layers 1M APP Base, PermaPly 28, See Note 2 12-Inch o.c. in 4-Inch lap and 18-Inch o.c. in (Optional) Inch plywood PermaPly 28, loose laid below Glosbase Plus cr VentsulatIan two, equally spaced, staggered center rows APP-TA APP-TA -45.0• W-13 Min, 15/32- (Optional) One or more layers DynaFast 180 HW or High Load Fasteners and APB 38-Inch o.c. within the min. min. 4-inch wide, (Optional) Inch PermaPly 28, loose laid DynaFast 250 HW Plates or High Load Plates heat -welded side laps. APP-TA APP TA -45.0• W 14 Min. 19/32- (Optional) One or more layers Two plies of PermaPly 28 or See Note 2 9-Inch o.c. in 4-Inch lap and 12-Inch o.c. in (Optional) Inch plywood PermaPly 28, loose laid below Ventsulatlon — two, equally spaced, staggered center rows APP-TA APP-TA -52.5 Exterior Research and Design, U.C. d/b/a Trinity) ERD Certlflcate of Authorization #9503 Prepared by: Robert Nleminen, PE-59166 Evaluation Report J9340.07.08-R4 for IL1046-R7 Revision 4:04128/2015 Appendix 1, Page 5 of 21 Florida Building Code Online, Page 1 of 5 IIA t•a ��x�--�(F � MS Home tog in U., ".tmtim Ha Twp Business(,,, Product Approval Professibnal 00 USER: PubIcUe Regulation ' las Submit Sumharge Sots&Fads Pubs dons F8C Stan - eC[S Site Map - Unks . Search P Jud Approval Mom>Product a Application Search> AOGimdon Ust> APPiitation Detail FL * FL7849-R8 Application Type Affirmation Code Version L2,0ii:l' Application Status Approved Comments Archived Product Manufacturer Boral Roofing / Monierl-ifetile Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 926181� (602) 515-6933 BoralRoofingUSAQuality@boral.com Authorized Signature Jemmett Thomas l BoralRoofingUSAQuality@boral.mm 6 Technical Representative Adrian Cooper Address/Phone/Email 1369 Hammandvllle Road Pompano Beach, FL 33069 (954) 786-5360 adrian.cooper@boral.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Thomas B. Jemmett 7575 Irvine Center Drive Irvine, CA 92618 (602) 515-6933 BomIRoofingUSAQuality@bomi.com Roofing^—' Rbofihg•Tiles f_ Evaluation Report from a Product Evaluation Entity ICC Evaluation Service, LLC R I Ogawa & Associates, Inc. 12/31/2016 Gary W. Walker Validation Checklist - Hardcopy Received FL7849 R8 COI ICC - Statement of Ind ependence.odf FL7849 R8 COI RI Ogawa Associates - Statement of Independence- 2013 odF Referenced Standard and Year(of Standard) Standard ASTM C1492 Equivalence of Product Standards Certified By Sections from the Code Year 2003 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt04mGNBAAI... 8/11/2015 Florida Building Code Online.., Page 2 of 5 C { I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity ,yes . No .,N/A Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of ^Products Go to Page 0 FL7849 R8 COC Engineering Statement.odf Method 1 Option C 05/29/2015 � 05/29/2015 1 11 .ii l3'tf/np,e\��Pjj� o6/02rzo1s � �� � �6 L, '' R ® O Pagel/20 0 FL # Model, Number or Name Description 7849.1 Atlantis - Slate &Textured Flat Profile - Pompano Beach Limits of Use Installation Instructions Approved for use in HVHZ: No Fl.7849 R8 II Boral EBS Instaliation.odf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation.pdf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647 df 7849.2 _ Barcelona 900 14gh'Pmfile:-. Lake Wales Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.odf Approved for use outside HVHZ: Yes FL7849 R8 If FRSA-TRI In t II t'on ndf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647 ndf 7849.3 Capri Medium Profile - Lake Wales Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 If Boral EBS Instailation.pdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Instailation.odf Impact Resistant: N/A Verified By: Gary W. Walker 4D455 Design Pressure: N/A Created by Independent Third Patty: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647.pdf 7849.4 Cedadlte / Cedarite 600 Flat Profile - Gilroy Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.gdf Approved for use outside HVHZ: Yes FL7849 R8 II Cedarlite Madera Installation.pdf Impact Resistant: N/A FL7849 R8 II FRSA-TRI Installation.ridf Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R8 AE ESR-1647.odf 7849.5 Espana / Barcelona High Profile - Lake Wales Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.pdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation odf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 R8 AE_ESR-1647.odf 7849.6 Espana / Barcelona High Profile - Henderson Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boras EBS installation.odf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installatlon.lidf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwd)gt04mGNBAAI... 8/11/2015 Florida Building Code Online Page 3 of S Evaluation Reports FL7849 RB AE ESR-1647 odf 7849.7 Madera Flat Profile - Gilroy Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7849 R8 II Boral EBS Installation.pdf FL7849 R8 If Cedarfte Madera Installation.pdf FL7849 R8 II FRSA-TRI Installation.odf Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R8 AE ESR-1647 odf 7849.8 Madera 700 Flat Pmfile - Gilroy Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.ndf Approved for use outside HVHZ: Yes FL7849 R8 II Cedarfte Madera Installatim1.It—df Impact Resistant: N/A FL7849 R8 II FRSA-TRI Installation.pdf Design Pressure: N/A Verified By: Gary W. Walker 40455 other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R8 AE ESR-1647.pdf + 7849.9 Saxony - English Thatch, Shake, Slate & Split Shake Flat Profile - Lake Wales Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL7849 R8 II Boral EBS Instaliation.ptlf FL7849 R8 II FRSA-TRI Insallatian.odf �l Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 R8 AE ESR-1647.pdf 7849.10 Saxony - English Thatch, Slate, Flat Profile - Katy Shake, Country Shake, Country Slate, Country Split Shake Limits of use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Instaliation.pdf Approved for use outside HVHZ: Yes FL7849 R8 11 FRSA-TRI Installatlon.odf Impact Resistant: N/A Verified By: ICC Evaluation Service, LLC Design Pressure: N/A Created by Independent Third Party: Other: Evaluation Reports FL7849 Re AE ESR-1647 odf 7849.11 Saxony - Shake, Slate, Country Flat Profile - Denver Slate & Split Old English Thatch Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 IT Boral EBS Installation.pdf Approved for use outside HVHZ: Yes FL7849 R8 U FRSA-TRI Installation.lidf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 R8 AE ESR-1647.vdf 7849.12 Saxony 600 - Shake, Slate & Split Flat Profile - Stockton Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Insallation.pdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation odf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 R8 AE ESR-1647.pdf 7849.13 Saxony 700 - Shake, Slate & Split Flat Profile - Stockton Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.pdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation pit Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL7849 RB AE ESR-1647.Dtlf 7849.14 Saxony 900 - Country Slate, Shake Flay Profile - Henderson & Slate http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt04mGNBAAI... 8/ 11/2015 Florida Building Code Online Page 4 of 5 Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Bora1EB5 Installation. d Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-Till Installation.pdf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 RS AE ESR-1647.pdf 7849.15 Saxony 900 - Country Slate, Shake, Flat Profile - Lake Wales Slate t Split Shake Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Installation.rid Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation.pdf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports FL7849 R8 AE ESR-1647.vdf 7849.16 Saxony 900 - Hartford Slate, Split Flat Profile - Stockton Old English Thatch, Shake, Slate, Country Slate Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: FL7849 R8 II Boral EBS Installation.fidF w.a FL7849 RS II FRSA-TRI Installation.odf yC Verified By: Gary W. Walker 40455 1'r Created by Independent Third Party: Yes 4\. Evaluation Reports �"a FL7849 R8 AE ESR-1647.pdf 7849.17 Spanish'S" High Profile - Pompano Beach Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Instailatlon.pdf Approved for use outside HVHZ: Yes FL7849 R8 II I RS&H Installation. -i f Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other. Evaluation Reports F1-7849 RS AE ESR-1647.pdf 7849.18 Spanish'S' Nuevo High Profile - Lake Wales Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boral EBS Insteltago�f Approved for use outside HVHZ: Yes FL7649 R8 II FRSA-TRI Installation.pdf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647.odf 7849.19 Tejas Espana / Barcelona High Profile - Katy Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R8 II Boal EBS Insallation.pdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Insallation.pdf Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647.pdf 7849.20 Vanguard Roll Medium Profile- Pompano Beach Limits of Use Insallation Instructions Approved for use In HVHZ: No FL7849 R8 H Baal EBS Insaliatin Rdf Approved for use outside HVHZ: Yes FL7849 R8 II FRSA-TRI Installation.nd Impact Resistant: N/A Verified By: Gary W. Walker 40455 Design Pressure: N/A Created by Independent Third Parry: Yes Other: Evaluation Reports FL7849 R8 AE ESR-1647.odf Go to Page '.�'. fg d Page 1 / 2 Cork ne4t 5pninott) :: 1940 North Monme street.Tallahassee FL 33399 phone' 8S0-0R7-1R24 The Sate of Rolla 6 an AA/EEO employer. C4ovrioht 2007-2013 State a Florida.:: f rivary Statement :: Accessibffity Statement:: Refund Statement Under FlMda brv, Coat addresses are public reards. V you do notrvant your a Wl address releaser in resporse to a public- rds recuesr do not send elecbmk mail N this endh. Instead, tantact We office by phone or by Va tumal mall. If you have any euesaons, please Contact 850A87.1395.-Punnanl to Section 455.275(I), Florida Statutes, eeeAve October 1, 2012, licensees licensed under O mmr 455, IS. mu4 provide the Department With an email address if they have one. The enalif provided may be used for of icial communiad. th the lirensee. Hmvever email addresses are public moard. If you do not wish to pp`gq�`QQj�r http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt04mGNBAAI... 8/11 /2015 Florida Building Code Online _ Page 5 of 5 supply a petsmal address, pb awide the Depamnent with an anal addamm wli ch Can be made avadable as the pubic. To determine I( you area raaa. ender chapter 455, FS., please d&hg . Pmdust Appsoaral Accepts: ---1 //X��(LTTrIIPVi iHu. http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwd)gtO4mGNBAAI... 8/11/2015 1- Florida High Wind Conerete 5d, UONE501TI;, and Clay Tile Installation Manual IRK FA Oj 4A Oe P4. ME F:v VIM �17- Oc: I TMM IT AL TILE. ROOFING I N S T I T U T E RSA N&modlf t Sth EDIlTION REVISED cont'd from page 2 Hip and Ridge Plastic Support Structure - Shall be in compliance with the Florida Building Code (FBC). Hip and Ridge Plastic Support Structure shall meet the test require- UNDERLAYMENT & FLASHINGS Inspection - Verify that surfaces to receive the underlay- ment are uniform, smooth, clean and dry. Proper ventilation is recommended on all tile applications. Verify ventilation requirements as set forth in the governing building code. When exposed ceilings are utilized, special precautions - - F-RSA/M ments of SSTD-I I and verified by third party independent FBC approved laboratories. , should be used. ev.N_Roof Parameters -Use the to � v`kn d' to e type of roof that will be installed. to d)3c' - ent upon the next. Do not mix ar r�a[`2�1Ilow the table as it flows from left to right, f ti� Yes J 4 12 and Greater 4;f2`and Greeater - Mechanical or Adhesive Mechanical Mechanical or Adhesive _ Single Self Adhered Pre -Formed Either Transmonal •y Two Single 'Sii _ �glz 7 Two Cold Applied Pre -Formed Either Transitional — HeatApplied Pre -Formed Either Transitional — Hot Mo ed Pre -Formed Either Transitional — Self Adhered Dry/Mechanical Self Adhered Cold lied Pre -Formed Pre -Formed Pre -Formed Either Either Either Transitional Transitional _ — Standard Pre -Formed Either -- Heat Applied Standard Pre -Formed Either — Sealed Hot Mopped Standard Pre -Formed — Either — Sealed _ Self Adhered Standard Pre -Formed — Either — Sealed _ Mechanical Single Dry/Mechanical Standard Pre -Formed Either — Transitional See note below — 3:12 Less than 4:12 2:12 Less than 4:12 Mechanical or Adhesive Adhesive Single Two Single Two Self --Adhered Cold Applied Heat Applied Hot Mopped Self Adhered Self Adhered Cold Applied Heat Applied Hot Mopped Self Adhered • Standard Pre -Formed Without Returns — Sealed Sealed Standard Pre -Formed Without Returns Sealed Sealed Standard Pre -Formed Without Returns — — Sealed Sealed Standard Pre -Formed — Without Returns Sealed Sealed Standard Pre -Formed — Without Returns — Sealed Sealed Standard Pre -Formed Without Returns — Sealed Sealed Standard Pre -Formed Without Returns — Sealed Sealed Standard Pre -Formed — Without Returns — Sealed Sealed Standard Pre -Formed — Without Returns Sealed Sealed Standard Pre -Formed — Without Returns Sealed Sealed Standard — — - _ Sealed COPYRIGHT i--••. ee,.e���-s�:°;r.�e.Lcn.LitMrauanv_nnnstrucuons' orProduet app�ovel._1 FRSA/TILE ROOFING INSTITUTE April 2012 Ioa000011011001{®Oil�01,10�i1u�10�1�1�1vu00i10��1�fot��ly�1C1�1 r 0 O 33 m m O O n Z L7 Z C m x f' ON o Ln In In O 4p In .la O w In w O N In N O 3 _ y ; o 0% O to In to O •1> In •PP O w In w O N In N O C 3 _ H ; n D% O In Ut In O .A. In .P O w V1 w O N In N O Ln 3 _ H o t� N 1a �D N 0` N N N 0o N N N N V N N — N w N- D` a% O to Ul - O 00 O N �D OO �D N Oo V V �D V — O+ N N O nn N co -P %O In 'O w w w w O N nC 'O 4w 00 M V 00 .A .o -,4 a, (n w N� In P w O— O W O to w p .A w Oo .A V w N-- N b% �D O �O O— CD W �D C 00 co -,IV— O, — P D`— O w 0` 0+ 0` D` O W •P O W w w w N N 4.. �O 4A W w W — O O 0', Oo — N N N �D O] O� O O V •p O N �D w N N N OD Oo V co iw In N N N V 0` In 0 N -P N N N J> w N •ice tw o ,p O N N O N N N— — — O Ln CO N — — :O 00 W V �O — —— W DO W ,p �O O OWo .A. V Oo V N M w to 4p ? in w w— N 0 V O Cnn < O. w a` w O N 4 w in O �o WO — 10 N w O m Oo w w N O < a Ul w .•NP V— .A w N N 0` N V 0 ao 0 W 0 0 Oo W of O a N V �p G. N m M G. Ln ry O. .p •A 4 .p Ja .p w w N V O w 4 .A w — 1O O w w w w w w -4O% ? .O D` �O — p� O w COOO w w w w -4O% to 0` �o �o w w w In •A w N N N ^ w w N — O 00 Oo In 00 — O N Oo 00 N N N M O, V — .A .A N N N In w :A V V V N N N w w w V V V O • � 3 2 � 7 3 = 7 3 to O — .A J> .A. �O CO V iJ In 0o -P •P A O, In •P D` in L. .p .7a w N — %O Co w .p. V O .p w N 4 .A 4 N — O .A V to w w w �O 00 V Oo ;7, In w w w Ln -P N �o .P. In � V O w N In w W N — — %O V O Oo N N N %D V O% — �o OD Nl N} N' Os O� �D�, Ou�OO-•Oo — V O Ln 0% — to Ln to Ln 4 w N:b..•In In to .p N— :O 1.1 C V .p .p N a` � O N— 01 O .A CO .A -P .A 1+. V 0% to a` V :? .A .A •A 4 w N 4` w O .P w w O CO 0` w a` .A GO O w O, 4A w w w to 4 w U, V 4? w w w N— PPPP � w O w w w O co — OD O N2., cn O LO �;, 0` V 00 Ln n Ln w 00 :4 V1 W In O, N �p O In p O W Ln to w N 0 O O T 4 1 .A • %O w 0% V N W -P 4...P •A W O %O O 0` — 7p O •A O 01 w w w �D W V O\ V N W W W D, P W w .O .A. W w w w •A -PC . 0 0. fD a e a O a 3 n C M 9 3� O B9`tl O rt O 9 -n N a 57 w Sth EDITION REVISED TARLF 3 Mechanical Roof Tile Resistance Values (ft-lbo For Field Tile Deck Thickness Method Fastener Type Attachment Description Low Medium High I SS, I c 25.2 25.2 35.5 Nail 2 SS, I c 38.1 38.1 44.3 Direct 2RS 39.1 36.1. 28.6 Deck 2 RS 4" HL 50.3 43.0 . 33.1 Scre v �I, No_ 8�_] =� 39.1 ,.f33-1 28.7- 1 I5/32" 2 No. 8 50.2 55.5 51.3 1 SS, 1 c 27.5 27.5 29.4 Nail 2 SS, I C 37.6 37.6 47.2 Batten 2 RS 24.6 36.4 26.8 I No.8 25.6 30.1 25.5 Screw 2 No. 8 36.1 41.9 37.1 19/32" Direct Deck I Nail i 2 RS 46.4 45.5 4(' y 5 .. y yl SS = Smooth Shank Nail or Screw Shank RS = Ring Shank • `, ' n C = Clip HL = Head Lap �V For Uplift Resistance Values for Foam Adhesives, see TR1 Technical Bulletin 2012-100, which is avaJable for download at www.Tileroofrngorg For mean roof heights over 60 ft, engineering calculations must be submitted for permitting. ASCE 7-20I0 WIND MAP FOR EXPOSURE C 160 (72) (76) 180 (80) `180 (80) COPYRIGHT FRSAITILE ROOFING INSTITUTE April 2012 l® _ METAL STRUCTURE HIP AND RID Mechanical Option (Cont.) HIP AND RIDGE'ATTACHED WITH CODE —APPROVED ADHESIVE METAL HIP AND RIDGE FRAME 5th EDITION REVISED PPORT FHW-14A IKIeTAi_L PER MANUFACTURERS JCT APPROVAL APPROVED ADHESIVE RLAYMENT APPROVED FOR SIVE APPLICATIONS GINSTALL� P.ERc=MANUFACTURERS .i�PRODUCT APPROVAL I NOTE: Stacking of nailer boards may be used. Maximum thickness of 2" per additional nailer board. The drawings are for illustrative purposes only. NAIL PENETRATION WITH COMPATIBLE ROOF CEMENT UNLESS UNDERLAYMENT MEETS ASTM D-197D SECTION 7.9 COPYRIGHT FRSA/TILE ROOFING INSTITUTE April 2012 1 ,,Florida Buildin,a Code Online - . Page 1 of 2 � K a wtA FLog MG Home In User RegistaGm Hot Topics 50noit Surcharge slats & Facts Business; ..,.Ill Professional '< ) USER: PubApprovalProdct ficc User PraduR Approval More > product or Apprczuon Seartm > AAlicahon List > Application Derail FL 4 FL14317-R7 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Publications MC Staff ,SCIS Sits Map Links Search Boml Roofing / MonierLitetile 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (602) 515-6933 BOMIRoofingUSAQuality@boml.com Jemmett Thomas BomiRoofinq USAQ uality@ boml.com Adrian Cooper 135 NW 20th Street Boca Raton, FL 33431 (954) 520-5461 amopeer@minierlifefile.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J. M. Nieminen PE-59166 UL LLC 10/13/2017 John W. Knezevidt, PE J Validation Checklist- Hardcopy Received FL14317 R7 COI 2015 01 COI Flieminen.pdf Standard Year ASTM D1970 2009 FRSA/rRI (April 2012) 04-12 2012 TAS 103 1995 UL 1897 2004 bttn://www.floridabuilding:.or./or/pr app dtl.aspx9param=wGEVXQwtDgsbCUITTZel20B... 8/26/2015 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 07/01/2015 Date Validated 07/02/2015 Date Pending FBC Approval 07/11/2015 Date Approved 08/19/2015 Summary of Products FL # Model, Number or Name Description 14317.1 Boral Roof Underlayments Roof undedayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL14317 R7 II 2015 07 FINAL ER BORAL Underlayments FL14317- R7.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: +N/A/-202.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application pertains to a particular undedayment FL1317 R7 AE 201�5 07 FINALER BORAL Underlayments FL14:u7- R7.pd_f system for use under foam -on tile systems. Refer to ER Section 5.6.2 for all such systems Created by Independent Third Party: Yes and max design pressures. 2.) Refer to ER Section 5 for Limits of Use. Back FY Contact Us :: 1940 North Monroe Samar, Tallahassee FL 32399 Phone: SM-487-1824 The State of Dodda 6 an A EO employer. Copyright 2007-2013 State of Florida.:: Privacy statement :: Accessibility Smtemant :: Refund Statement .der Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public,records re, , do not send ironic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any quedans, please contact 850.487.1395.'Pummon, to on 455.275(i), Florida Statutes, effective October 1, 2012, licensees Ecensed under Chapter 455, F.S. must provide the Department alth an email address if have one. TM1e email provided may be used a,.ff c40 comommimUon v:im the licensee. However email adder are puble record. If you do not wish to a personal address, please provide the Dc x m m, %vAh an email address which can be made available to the Public. To dermame, if you are a lnme ee under croupier 455, F.S., pleese click here . Product Approval Accepts El http://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgsbCUITKel2OB... 8/26/2015 h EXTERIOR RESEARCH & DESIGN, U.C. certificate of Authorization N9503 N STREET, UNIT #13 �TRINITY ERD 353 CHRISTIAOXFORD, Cr 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Boral Roofing Evaluation Report M35710.12.10-R8 7575 Irvine Center Drive - F1.34317-117 Suite 100 Date of Issuance: 12/21/2010 Irvine, CA. 92618 Revision 8: 07/01/2015 SCOPE: This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Merriman, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the P Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CON71NUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `TrinitylERD Evaluated' may be displayed in advertising literature. if any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert.I.M. Nieminen, P.E. Florida Registration No. 59166, Florida Ocei ANEI9s3 Z lea Ir �r 9.L..0mra:eNapread,c wasaNMRxed CyR^.EeR fil^mNey e.r.000r/oUtoss. TNadavvm..n. a:m:pamnWurara.a darymanESlrne FmduaAAd;rV hmdcnpka Ra:e Csn Oznomiaxd mrFn ppt>gl AdmklRmtcand mtta aamza atom CERTIFICATION OF INDEPENDENCE: 1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity( ERD fs notowned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nleminen, P.E, does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved In the approval process of the product S. This Is a building code evaluation. Neither Trinity) ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. -J 1 R{N('Y( ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Umitations/ Conditions of Use set forth herein, 2, STANDARDS: Section 15043.1 1507.2.4,1507.2.8,15072.9.2,1507.45.1, 1507.45.2, 1507.5.3,1507.53.2,1597.63, 1507.6.3.2,1507.7.3,1507.73.2 1507.33 1523.65.2.1 3. REFERENCES: Entity ERD(TST5049) ERD(TSf5049) ERD (TST 6D49) ERD (TST6049) ERD (TST 6D49) ERD (TST 6D49) ERD (TST 6D49) ERD (TST 6049) ERD (TST 6049) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST58781 PRI (TST58781 PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) UL, LLC. (QUA 9625) UL, U.C. (QUA 9625) UL, LLC. (QUA 96251 4. PRODUCTDEScRIPTiONi Property Wind Uplift Physical Pmperties Installation Practice Physical Properties Examination Wind Uplift Physical Properties Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Wind Uplift Quality Assurance Quality Assurance Quality Assurance Standard UL1897 ASTM D1970 FRSA/TRI April 2012 (04-12) TA5103 Reference T6460.06.07-RS T33190.08.10 M33180.08.10 T37610.07.11 840380.08.12 C41420.09.12-2 B41940.09.12 847390.07.14-1 B47390.09.14 NE1-006-02-01 NEI-034A2-02 NEI-045-02-01 NEI-053-02-01 NEI-070-02-01 NEI-031-0102:REV 10.27.10 NF1-029-02-01REV: 11.03.10 NEI-046-02-MEV NEI-034-OM2/ MLT-015-02-01 BORR-001-02-01 BORR-005-02-01 Service Confirmation, R14610 Cross -Listing Confirmation, R16744 Service Confirmation, R16744 Year 2004 20D9 2012 vr: /+I 1995 e Date 10/09/2007 08/05/2030 10/09/2010 07/29/2011 08/28/2012 09/11/2012 09/13/2012 07/31/2014 09/04/2014 04/022002 03/2320D6 oa/082007 05/01/2008 08/12/2009 10/272oia 12/03/2010 12/17/2010 01/29/2013 03/17/2D35 05/24/2015 Exp.12/10/2017 09/D4/2013 Exp.10/13/2017 4.1 Self -Adhering Underiayments: 4.1.1 Boral TIIeSeal® SOOT is a nominal 50-mil thick, polyester -surfaced, self -adhering 5B5 modified bitumen roof underlayment. Bar Tit- eale � . is a nominal 60-mii thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment. 4.1.3 GatcrrSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment. 4.1.4 StormSentry"° is a nominal 120-mil thick, mineraf-surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment. 4.1.5 Citadel' Plus Is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlaymentfor use as a base -layer in two-ply underlayment systems. Ehterlor Research and Design, U.C. Evaluadan Report M35710.12.10-RB carlyrrareafAmharharion,0503 FL14317-R7 Revision 8: 07/01/2015 Page2of 6 5. �I TRINITY I ERD LIMITATIONS: 5.1 This is a building code evaluation. Nefther Trinity) ERD nor Robert Meminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is notfor use in the HVHZ. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product 5.4 Bural Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. if not listed, a request may be madeto the AHJ for approval based on this evaluation combined with supporting data forthe prepared roof covering. 5.5 Allowable roof covers applied atop Bural Roof Underlayments are follows. Table 1 pertains to use of each listed underlayment by-itseif beneath the stated roof covers. Refer to the installation Instructions and Table 2 for two-ply underlayment options. 5.5.1 5.6 5.6.1 5.6.2 5.5.2.1 Underlayment Asphalt Nail -On -rite Foam -On Tile Metal Wood Shakes Slate Shingles & Shingles eoml TlleSeal Sdn Yes yes No Yes Yes Yes (battens only) yes oral Tilesea Yes YES Yes Yes Yes Pill ISee5.5.1I GatorSeal Yes yes No No Yes. Yes (battens only) StarmSernry Yes Yes No No Yes Yes "Foam -On Tile" is limited to use of the following unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Underlayment Tile Adhesives 3M"' 2{ampcnent Foam Roof -rite Adhesive AH-160 (FL6332) 3M- Roof Tile Adhesive RTA-1(FL6276) Bomi Tliesear Dow TILE BONDTM Roof Tile Adhesive (FL717) Convenience Products' Touch'n Seal Stormoond Roof Tile Adhesive (FL34505) Allowable Substrates: A�(� Direct -Band to Deck: ,pry Citadel Plus, Bural TlleSeal Ser Boral TileSeai , Stormsentry or GatorSeal: i i) D Plywood (unpdmed or primed with ASTM D41 primer). cc.Yt,=y FA ,(j ...111111 Baral T)IeSealm: D OSB primed with ASTM D41 primer. Wind Resistance of Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed In FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table SA or FBC 1609 for determination of design wind loads. Maximum Design Pressure=-105psf. Deck: Min. 15/a2-Inch plywood to meet project requirements to satisfaction of Authority Having lurtsdlctioA. Base Ply: (Optional) Citadel Plus, self -adhered Underlayment ¢oral TlleSealw,self-adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y,"ring shank nalisthmugh 32 ga., 1-5/e" diameter tin caps spaced 12-Inch o.c. Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-118 eerd/kaM01Aupodmdon Ml503 FL14317-R7 Revision 8: 07/01/2015 Page 3 of 6 6. J TRINITY ERd 5.6.2.2 Maximum Desian Pressure=-202.5 osf Deck: Min. 15/3Z-inch plywood to meet project requirements to satisfaction of Authority Having.lurisd'ictlon. Primer: ASTM D41 to the plywood deck ease Ply: (Optional) atadel Plus, self -adhered Undedayment: kora s, 11f-adhere An 4 a.x1Y- ilT 5.6.3 Bond to Base laver Underlavment: Citadel Plus, Boral TIIeSeal 50"r, Boral TileSeal"ror GatorSeal: 9 ASTM D226, Type ll felt Citadel Plus. StormSentry: ➢ ASTM D226, Type II felt Citadel Plus. For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1 or as tested in accorda itti FBC Section 1504.3.E T 5.6.4 Bond to Offer Substrate Types: I A (Fil 0 a1 Citadel Plus, coral Tile5eal50"T, BoralTte5eal"r, StormSentry or GatorSeal: D ASTM D41 primed metal (e.g., flashing metal, valley metal, etc). Boral TileSealw: D Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. e Note: For Installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.7 Exposure Limitations: 5.7.1 GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. 5.7.2 StormSentry shall not be left exposed for longer than 90-days after installation, prior to placement of final roof cover. 5.7.3 Alcazar, Bored TileSeal Se and Boral TileSeal"T shall not be left exposed for longer than 180-days after Installation, prior to placement of final roof cover.- 5.7.4 Citadel Plus, for use as a base -layer in a two-ply underlayment system, shall not be left exposed for longer than 180- days after installation, priorto placement of subsequent underlayment layer. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance With Boral Roofing published installation Instructions subject to the Limitations set forth in Section 5 herein and the specks noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (If applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40'F and rising. 6.4 Citadel Pius: 6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"r, Boml TileSeal "r, GatorSeal or StormSentry. 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane Into manageable lengths, typically SO to 12 ft. Align the membrane parallel to the roof edge, extending over by Y4nch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 124nch o.c. for slopes 7:12*and greater. Overlap successive courses minimum 2 Inches (horizontal lap) and minimum 4" end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal So"; Boral TIIeSeal" ; GatorSeal or StormSentry. Exterior Research and Design, 11C Evaluation Report M35710.12.10-118 Cwtillmte ofAuthwrzatlnnNs50i FL14317-R7 Revision 8: 07/01/2015 Page of 6 `I TRINITY ERD 6.4.4 To Base Sheet Install ASTM D226, Type II felt In accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published Installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install Citadel Plus as a mid -ply in accordance with floral Roofing published installation instructions and Section 6.4.3. Install final underiayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TiieSeal Se, Boral TleSeal"T, GatorSeal orStormSentry. 6_5 Baral Tle5eal 50"T: 6.5.1 Install Boral TleSeal 50"T in compliance with manufacturers published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 15O7 for the type of prepared roof covering to be ins 6.5.2 Do not use Boral Tile5eal Se an roof pitches less than 2:22.- 6.5.3 Non -Tile Applications Dlrectto Deck: (7ty] Cut the membrane Into manageable lengths, typically 10 to 12 ft Align the membrane parallel to Stt�'y� dge PI extending over by Y-Inch. Fold the membrane away from the edge onto itself. Remove the release sheet.th rmembrane with the exposed rubberized asphalt onto the deck, pressing firmly Imo place. Boll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-Inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-Inch. - Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published Installation instructions. 6.5.4 Non -Tile Applications. to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements. Install Boral Tlle5eal 50"T In accordance with Boral Roofing published Installation instructions and Section 6.5.3, except and (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface Into place with a weighted roller. 6.5.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04.12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Battens must be used for all the Installations atop Boral Tileseal 50"T. Boral Roofings Elevated Batten System'" or counter battens are required for roof pitches of 2 Y:12 to less than 4:12. 6_6 GatorSeal and5tornSentrv: 6.6.1 Install GatorSeal and StermSentry In compliance with manufacturers published installation Instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. Do not use StarmSentry on roof pitches less than Y:12 while ensuring there is no possibility for Funding water on the surface of StormSentry. 6.6.3 Non -Tile aupHull ons. Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y.-inch. Fold the membrane away from the edge onto itself Remove the release sheet Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly Into place. Roll into place with a weighted roller. Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c, for slopes below 7:12 and 12-Inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the Interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published Installation Instructions. Exterior Research and Design, LID. Evaluation Report M35710.12.10-RS Cerujrmte ofeudmrbW1,,n 99503 FL14317-R7 Revision 8: 07/01/2015 Page 5 of 6 f 1 RI"TYi ERD 6.6.4 Non -Tile Applications to Base Sheet: Install ASTM D226, Type II felt in accordance with code requirements or Install Citadel Pius in accordance with Boral Roofing published installation Instructions and Section 6.4. Install GatorSeal or StormSentry over ASTM D226, Type 11 felt or Citadel Pius in accordance with Boral Roofing published installation Instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top surface, roiling the interface into place vnth a weighted roller. 6.6.5 Tile Applications: Reference Is made to FRSA/rRI April 2022 (04-12) Installation Manual and Table J. herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Battens must be used for all the installations atop GatorSeal. 6.7 Boral McSeal "T, 6.7.1 Install Gore, TleSeal uT in compliance with manufacturer's published Installation Instructions and the requirements for ASTM 01970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSeal in on roof pitches less than 2:12. 6.7.3 Non7ile Applications. Direct to Deck: For O5B substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallelto the roof edge, extending over by Y.-inch. Fold the membrane away from the edge onto Itself Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly Into place. Roll into place with a weighted roller. Sara[ recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c, for slopes below 7:12 and 12-Inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the blade -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.7.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type H felt in accordance with Code requirements or Install Citadel Plus In accordance with Bom1 Roofing published Installation instructions and Section 6.4. Install Boral TieSeal "r In accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside Is In contact with the fabric topsurface, rolling the Interface Into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 201.2 (04-12) Installation Manual and Table 1 herein, using the Instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Battens must be used for all the Installations atop Boral TileSeal `v with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. Approved foam adhesive may be used for roof slopes 2:12 and greater. 7. BUILDING PERMIT REQUIREMENTS:9 As required by the Building OfficialorAuthorttyHaving Jurisdiction Inorder toproperly evaluate the in Ilat ofII .pr ,5', fS B. MANUFACTURING PLANTS: 4 f ' } Contact the manufacturer or the named CA entityfor information on plants covered under Rule 61G20-3 4" y p QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC.—QUA9625;(414)243-6409;Karen.buchmann@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report M35710AL10-R6 rern/rmre afAudwr4atran s954. F1.14317-117 Revision 8:071011202S Page 6 of 5 'Planning 8 Development Services Building 8 Code Regulation Division 2300Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 5210 Citrus Ave City I State / Zip: Fort Pierce, FI 34982 Parcel#: 3404-802-0001-00018 Zoning: RS-3 APPLICATION INFORMATION Permit Number: 1508-0314 Permit Type: ROOF PERMIT - OTHER CONTRACTOR INFORMATION Contractor Name: Michael Miller Business Name: Trade Winds Roofing Inc Business Addr: Po Box 13208 City / State / Zip: Ft Pierce, FI 34979 REVIEW 1 Owner(s): Carmela Barbour / Charles Connolly Jurisdiction: SAINT LUCIE COUNTY Lot#: 1 Block: Stories: Automatic Sprinkler System? No Fax Number: 772-466-9725 Email: Mike@Tradewindsroofing.0 om Review Jito Status Reviewed By Date Started Date Comoleted Date Released FRONT COUNTER REVIEW COMPLETE Angela Huff 8120/2015 8/20/2015 8120/2015 Comment: PLANS EXAMINER REVIEW INCOMPLETE Dave Johnson 812612015 8/26/2015 Comment: PROVIDE DESIGN PRESSURE FOR TILE ROOF SYSTEM.-107.2 FBC 8126/2015 Comment: MAX DESIGN PRESSURE FOR UNDERLAYMENT SUBMITTED DOES NOT MEET REQUIRED DESIGN PRESSURE FOR ZONE 3. TABLE R301.2(2)FBC R 8126/2015 Comment: COMMENTS EMAILED TO CONTRACTOR MAILED TO OWNER