HomeMy WebLinkAboutFLORIDA ENERGY EFFICIENCY CODEFlorida Enerev Efficiency Code For Building Construction
Florida Department of Community Affairs
EnergyGauge FlaCom v 2.11 FORM 40OA-2004
Whole Building Performance Method for Commercial Buildings
Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
Short Desc:
FSCP
Owner.
FIRST SOURCE COMMERCE PARK
Address:
SOUTH KINGS HWY
ST LUCIE
City:
ST LUCIE
State:
FL
• Zip:
0
Type:
Office
Class:
Renovation to existing building
Component
Gross Energy Use
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
Project: FIRST SOURCE COMMERCE PARK
B-103
SCANNED
P S of revs: 1 St <Ucie County
"Conditioned Area: 517 • denotes lighted area
"Cond + UnCoad Area: 517 Dow not i wellcrose
Max Tonnage: 2.0 (if different, write in)
Compliance Summary
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
Design Criteria Result
565.22 581.66 PASSES
PASSES
None Entered
PASSES
None Entered
None Entered
None Entered
Yes/No/NA
IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of
this design building must be submitted along with this Compliance Report 11
3/1/06 EnergyGauge FlaCom v 2.11 FORM 40OA-2004
1
n
I hereby certify that the plans and
specifications covered by this calculation
are in compliance with the Florida Energy
Efficiency Code.
PREPARED BY: /�dj s r---,*%bZ7V4fr
DATE: 3.07• o(o
1 hereby certify that this building'is in compliance
with the Florida Energy�Effjcieney-B .
DATE:
Review of the plans and specifications covered by this
calculation indicates compliance with the Florida Energy
Code. Before construction Is completed, this building will be
inspected for compliance in accordance with Section
553.908, F.S.
BUILDING OFFICIAL:
DATE:
If required by Florida law, I hereby certify (") that the system design is in
compliance with the Florida Energy Code.
ARCHITECT:
ELECTRICAL SYSTEM DESIGNER
LIGHTING SYSTEM DESIGNER:
MECHANICAL SYSTEM DESIGNER:
PLUMBING SYSTEM DESIGNER:
4,ec* r"aFt7Wq&-
REGISTRATION
No.
/22 qS
(•) Signature is required where Florida Law requires design to be performed by registered design professionals.
Typed names and registration numbers may be used where all relevant Information is contained on signed/sealed
plans.
03/0 3/�6
2/28/66 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 2
Project: FSCP
Title: FIRST SOURCE COMMERCE PARK B-103
Type: Office
(WEA File: DAYTONABEACKTMY)
Whole Building Compliance
Design
Reference
Total
96.75
100.00
$565.22
$581.66
ELECTRICITY(MBtulkWhl$
96.75
100.00
11,327.00
11,727.00
$565.22
$581.66
AREA LIGHTS
15.75
14.75
1,838.00
1,742.00
$91.72
$86.40
MISC EQUIPMT
9.75
9.75
1,136.00
1,136.00
$56.69
$56.3S
PUMPS 8: MISC
0.25
0.25
31.00
30.00
$1.5S
$1.49
SPACE COOL
23.25
21.50
2,716.00
2,511.00
$135.53
$124.55
VENT FANS
47.75
53.75
5,606.00
6,308.00
$279.74
$312.88
Credits & Penalties (if any): Modified Points: = 96.76
PASSES
External Lighting Compliance
Description Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (W)
_ (Sgft or ft)
None
3/1/06 EnergyGauge FlaCom v 2.11 FORM 400A-2004
M
Project: FSCP
Title: FIRST SOURCE COMMERCE PARK B-103
Type: Office
(WEA File: DAYTONABEACH.TMY)
Lighting Controls Compliance
Acronym Ashrae Description Area No. of Design Min CompG-
ID (sq.ft) Tasks CP CP ance
ProzolSpl 16 Office -Open Plan 517 2 6 1 PASSES
:t: FSCP
FIRST SOURCE COMMERCE PARK B-103
System 1
Wslem Report Compliance
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component
Category
Capacity Design
Eff
Design IPLV Comp-
Eff
Criteria
1PLV Criteria fiance
Cooling System
Air Cooled < 65000 Btu/h
10.30
10.00
10.00 PASSES
Cooling Capacity
Air Handling
Air Handler (Supply) -
0.80
0.90
PASSES
System -Supply
Constant Volume
Description
Installed Size Design Mn Design Mn Category
No Eff Eff IPLV IPLV
None
Comp
fiance
3/1/06 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 4
Water Heater Compliance
Description Type Category Design
Eff
Min Design Max Comp
Eff Loss Lass liance
None
Piping System Compliance
Category
Pipe Din Is Operating Ins Cond Ins Req Ins
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
Compliance
[F] .SF.F]
None
Project: FSCP
Title: FIRST SOURCE COMMERCE PARK B-103
Type: Office
(WEA File: DAYTONABEACH.TMY)
Other Required Compliance
Category
Section
Requirement (write N/A in box ff not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
Sys
407.1
HVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
ADS
T & B
410.1
410.1
Duct sizing and Design have been performed
Testing and Balancing will be performed
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/mainterr nce manual will be provided to owner
Roof/Ceil
Report
404.1
101
R-19 for Roof Deck with supply plenums beneath it
Input Report Print -Out from EnergyGauge FlaCom attached?
3/1/06 EnergyGauge FlaCom v 2.11 FORM 40OA-2004
EnergyGauge FlaCom v 2.11
INPUT DATA REPORT
Pro iect Information
Project Name: FSCP Orientation:
Project Title: FIRST SOURCE COMMERCE PARK B-103 Building Type:
Address: SOUTH KINGS HWY Building Classification:
ST LUCIE
State: FL No of Storeys:
Zip: 0 GrossArea.
Owner: FIRST SOURCE COMMERCE PA
North
Office
Renovation to existing building
I
517
Zones
F:ENoAcronym Description Type Area
Multiplier
Total 1sf1
PrOZol Zone 1 CONDITIONED 517.0
1
517.0
Spaces
No Acronym Description Type Depth Width Height Multi
Iftl Iftl [ftl pfier
Total Area
Isil
Total Volume
fell
3/l/06 I EnergyGauge F1aCom v 2.11
In Zone: PrOZol
1 PrOZolsvi Zo0Sp1 Office -Open Plan
25.85
20.00
9.00
1
517.0
4653.0
Lighting
No Type Category
No. of
Watts per
Power
Control Type
No.of
Luminaires
Luminaire
[Wj
Ctrl pts
In Zone: PrOZ91
In Space: PrOZo1Sp1
1 Compact Fluorescent General Lighting
1
600
600
Manual
On/Off
6
Walls
No Description Type Width H (Effec) Multi
Area DirectionConductance
Heat
Dens. R--Value
Iftl
[it] peer
Isa
[Btu/hr. sf. F]
Capacity
[lb/cf] fh sf.FBtu]
[Btalsf FJ
In Zone: ProZol
1 PrOZol Wa3 5/8" stucco 35.60
10.00 1
356.0
South
0.2067
5.7314
34.65 4.84 1]
/8"CMU/3/4"ISO
BTWN24"oc/.5"
Gyp
Windows
No Description Type Shaded
U SHG
Vis.Tr
W
H (Effec)
Multi
Total Area
[Btu/hr sf F]
Ift]
[ft]
plier
[S}]
In Zone: PrOZol
In Wall PrOZo1Wa3
I PrOZOWa3Wi1 SINGLEREFB No
0.8785 0.23
0.05
10.00
9.00
1
90.0 Q
TINT-L
3/l/06 EnergyGauge MaCom v 2.11
Doors
No Description
Type
Shaded? Width H (Effec) Multi
Area
Cond. Dena Heat Cap. R-Value
[ft] [ft]
plier
[d)
IBtu/hr. sf F1 pb/cf] [Btu/sf. F1 [h.sf.F/Btu1
In Zone:
In Wall:
Roofs
No Description
Type
Width
H (Effec) Multi
Area
Tilt
Cond, Heat Cap Dens. R-Value
[ft]
Ift] plier
Is11
[deg]
[Btu/hr. SE F1 [Btu/sE F1 [Ib/cf1 1h sEFBtu]
Iu Zone: PrOZ91
1 PrOZo1Rf1
SnglPly/2"lso/2"
20.00
25.85 1
517.0
0.00
0.1372 4.74 71.00 7.29 ❑
ConclMtl Deck
Skylights
No Description Type
U SHGC Vis.Tran
W
H (Effec) Multiplier Area Total Area
[Bta/hr sf F1
[ft]
[ft1 [Sfl ISO
In Zone:
In RaoC
Floors
No Description
Type
Width
H (Effec) Multi
Area
Cond. Heat Cap. Dens. R-Value
IN
[ft] plier
[sf1
[Btu/hr. sf. F] [Btu/sf. 11 [Ibkf1 [h.sf.FBtu]
In Zone: PrOZol
1 PrOZo1F11
Concrete floor,
20.00
25.85 1
517.0 0.5987
9.33 140.00 1.67 ❑
carpet and rubber
Pad
3/1/06 Ener gyGauge FlaCom v 2.11 3
Systems
PrOSyl System 1
Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category
Capacity Efficiency IPLv
1 Cooling System (Air Cooled < 65000 Btu/h Cooling 23600.00 10.30 10.00
Capacity)
2 Air Handling System -Supply (Air Handler (Supply) - 800.00 0.80
Constant Volume)
ID
Plant
Equipment
Category Size Luit.No Ell.
IPLV
Water Heaters
W-Heater Description
Capacit Cap.Unit UP Rt. Efficiene LOSS
El
Ext-Lighting
Description
Category No. of Watts per Area/Len/No. of units Control Type
Luminaires Luminaire [sf/fdNol
Wattage
[W]
El
Piping
No Type
Operating Insulation Nomonsl pipe Insulation
Temperature Conductivity Diameter Thickness
IF] [ Btn-in/h sf F] [in] [in]
Is Runout?
3/1/06 EnergyGauge FlaCom v 2.11 4
Fenestration Used
Name Glass Type No. of Glass
Conductance SHGC VLT
Panes gku/6.sf.lq
ApLbWnd4 SINGLE REF B 1 0.8785 0.2270 0.0500 ❑
TINT-L
Materials Used
Mat No
Acronym
Description
Only R Value RValue Thickness
Conductivity
Density
SpecifieHea
Used [h.sf.F/Btu]
[ft]
[Btdh.ft.FJ
phict)
t
187 '
Matll87
GYP OR PLAS
No 0.4533
0.0417
0.0920
50.00
0.2000
❑
BOARD,1/2IN
151 .
Mat1151
CONC HW, DRD, 1401B,
No 0.4403
0.3333
0.7570
140.00
0.2000
❑
4IN
178
Mat1178
CARPET W/RUBBERPAD
Yes 1.2300
❑
268
Matl268
0.625" stucco
No 0.1302
0.0521
0.4000
16.00
0.2000
❑
42
NW142
8 in. Lightweight concrete
No 2.0212
0.6670
0.3300
38.00
0.2000
❑
block
269
Mat1269
.75" ISO BTWN24" oc
No 2.2321
0.0625
0.0280
4.19
0.3000
❑
82
Matl82
ASPHALT -SHINGLE AND
Yes 0.4400
❑
SIDING
11
Maul l
2 in. Insulation
No 6.6800
0.1670
0.0250
2.00
0.2000
❑
47
Mat147
2 in. Heavyweight concrete
No 0.1670
0.1670
1.0000
140.00
0.2000
❑
Constructs Used
3/l/06 EnergyGaage FlaCom v 2.11
No
Name
Simple
Massless Conductance
Heat Capacity
Density
RValue
Construct
Construct [Btu/h sf FI
[Btu/sEFI
pb/cf1
[h sf FBtu]
1004
Concrete floor, carpet and rubber pad No
No 0.60
9.33
140.00
1.6703
❑
Layer
Material
Material
Thickness
Framing
No.
Ift]
Factor
1
151
CONC HW, DRD, 140LB, 4IN
0.3333
0.00
❑
2
178
CARPET W/RUBBER PAD
0.00
❑
No
Name
Simple
Massless Conductance
Heat Capacity
Density
RValue
Construct
Contract [Btu/h.sEFI
[Btalsf FI
[Ib/cfI
[h.sf F/Btu]
1011
5/8" stucco /8"CMU/3/4"ISO No
No 0.21
5.73
34.65
4.8368
❑
BTWN24"oc/.5"
Gyp
Layer
Material
Material
Thickness Framing
No.
1111
Factor
1
268
0.625" stucco
0.0521
0.00
❑
2
42
8 in. Lightweight concrete block
0.6670
0.00
❑
3
269
.75" ISO BT WN24" oc
0.0625
0.00
❑
4
187
GYP OR PLAS BOARD,1/2IN
0.0417
0.00
❑
No
Name
Simple
Massless Conductance
Heat Capacity
Density
RValue
.
Coustruet
Construct [Bfttftsf F]
[Btu/sf F]
DWI
[h sf FBtuj
1043
Sngl Ply/2"Iso/2"
Conc/Mtl Deck No
No 0.14
4.74
71.00
7.2870
❑
Layer
Material
Material
Thickness Framing
No.
IN
Factor
1
82
ASPHALT -SHINGLE AND SIDING
0.00
❑
2
11
2 in. Insulation
0.1670
0.00
❑
3
47
2 in. Heavyweight concrete
0.1670
0.00
❑
3/1/06 EnerrgpvvGauge FlaCom v 2.11
S/N RNW20913 RIGHT•NCOAMERCIAL/INDUSTRIAL LOAD CALCULATION 2/27/06
For. FIRST SOURCE COMMERCE PARK (#B-103)
Zone: 1
Page: 1
Job BLD B UNIT B-103 S KINGS BMY ST LUCIE
City: Fort Pierce, FL, US
By: ABBOTT & ASSOCIATES
LW1I: 517.0 x 1.0 x 9.0
Units: U.S. customary (I-P)
.1. DESIGN CONDITIONS - COOLING ( 3 PM , August )
Dry Blb RI1 Moisture Range
'Outdoor
WOL Blb
Conditions •,: -7 90 59 15
78
Indoor Conditions 75 50
63
TOD Correction - n 0
Dnreacc 15 61
[ Mult
= 1.0 ] -
2. GLAZING SOLAR HEAT GAIN ( Lat = 27.00 ON, Corot Wt
= L
)
Type Dir Shad Tilt %ovr Area Sfact Shgf Shad
Sens
GIM I S N 90 100.0 90 0.69 42 1.0
1925
3. TRANSMISSION GAINS
Typo Dir GrAtea NtAmn Mal Grp CLTD Shed Clr
Sons
GLAZ 1 S 90 90 1.040 15.0 N
-
1404
MALL 1 S 225 225 0.122 D 20.5 N
D,
563
PART 1 - 221 22'1 0.087 15.0 -
D
288
ROOF 1 - 217 217 0.040 24.0
1)
206
4. INTERNAL HEAT GAIN
Sens
Latent
People 4 x Per person: sensible 190 latent
230
760
920
0 x Per po son: sensible 300 latent
300
0
0
Llghts Incandescents in RA Ceiling 0 x 3.4 x
60%
0
Fluorescents in RA Coiling 0 x 4.1 x
60%
0
Inoandesconts other 0 x 3.4 x
100%
0
Fluorescents other 600 x 4.1 x
1009E
2460
Motors Nmbr Power Gain Load Fact
Usage
t 1 0.00 0 1.00
1.00
0
2 1 0.00 0 1.00
1.00
0
3 1 0.00 0 1.00
1.00
0
AppL Nmbr Typo Sans Latent
Usage
I 1 ALL 2600 800
1.00
2800
800
2 1 0 0
1.00
0
0
3 1 0 0
4 1
1.00
0
0
0 0
1.00
0
0
5 1 0 0
1.00
0
0
Other 1 0 0
1.00
0
0
S. INFILTRATION
Sens
Latent
0 cfm ^- x dbTemp Diff 15.0 x 1.1
0
-- x Moist. Diff 61.5 x 0.68
0
6. SUBTOTAL COOLING LOAD FOR SPACE
10409
1720
-7-SUPP14Y DUCT E AT GAIN
Gain factor 0.10 x Line 6 Sensible Gain
1041
Manual M 4th lidltion Rigbt-N: ver.3.0.01
Certified by ACCA to meet all requirements of Manual Fotm N
IQbN: BLD B UNIT 13-103 8 KINGS HWY 9T LUCIE
Page: 2
8. COOLING PAN SIZING
Sum of Duct Gain (7 ), Line (6) & DrawihruFan
11449
(L S Sens ) / (1.1 x Supply TD ) M
• cEm = ( 11449) /
CEm
(1.1 x 20. 0 ) -
Actual Coo
Actual Cooling Fan
521
> -
521
9. VENTILATION
80 Ofm db Temp Diff 15.0 x 1.1
1319
--� x Moist. DitT 61.5 x 0.68
3345
'10, RETURN AIR LOAD FROM LIGHTING AND ROOF
Incandescent Lights 0 Watts x 3.4
Fluorescent Lights
x 40% 0
0 x 4.1
RA Roof Load
x 40% 0
f m Line 3
RA Ceiling Load Credit
(+) 0
fmm Line 3
() 0
11. RETURN DUCT HEAT GAIN
Gain factor . 0.00 x Line 6 Sensible Gain
0
12. TOTAL COOLING LOADS ONEQUIPMENT(Binh)
12768
5065
SPACE BEATINGLOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Beating TD = (Inside DB - Outside DB) - ( 70 - 4 2) 28
14. TRANSMISSION LOSSES
[ Mult =
1. 0 ] -
Type Expos GrAres NotAraa Uval irm
GLAL 1 S
Loss
90 90 1.100 28,0
WALL 1 8 225 225 0.122 28.0
2772
PART 1 - 221 221 0.087 28,0
ROOF 1
769
769
538
- 217 217 0.040 15,0
130
IS. INFILTRATION
0 cfm x db Temp I)Iff 28.0 x 1,1
Loss
0
16. SUBTOTAL HEATING LOAD FOR SPACE
4209
17. SUPPLY DUCT HEAT LOSS
Loss factor 0.05 x Line 16 Loss
210
1.8. VENTILATION
80 cfm x dbTmnpDitT 2B.0 x 1.1
2462
19. HUM► IFICATION
Inside RN desired ; 32.0 (Max = 32.0 for 1 pane )
N of Glazing panes 1.0 (Max = 52.0 for 2 pate )
80 Qfm x 1.48 9/100cfWd = 1.2 gpd
484
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
Manual N: 4th Edition Right N; Ver.3.0.01
Cetti6d by ACCA to meet all requirements of Manual Form N
JobN: BID S UNIT 8-103 5 ICINGS HWY ST LUCIE
21. TOTAL HEATING LOAD ON EQU PMENT (Stub)
Manual N: 4th Edition Right-N: Vee.3.0.01
CatiBed by ACCA to meet all requirements of Manual Form N
Page:
7316