Loading...
HomeMy WebLinkAboutCHVAC LOAD ANALYSISSleep City Mattress HVAC Load Analysis for Sleep City Mattress S Kitterman & US 1 (9 C, Port St. Lucie, FL �i �74" 0� O oG 4� r AL HVAG LOAIDS OPI F,it Prepared By: Eric J. Svoboda, PE Fort Pierce Engineering, Inc. 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 Friday, February 13. 2009 xChSao 2Full CommofatalpHVAC Loads Calculation Program+�, T�f 1!'A] -- -c p��"t� frig,} 'r`,r yw Tr ,, , Elije SOttNiare R velobrrldti�filncY �����-{,h_. �:. � l Z . �IJ.a" d � f,'4V i •l 3zvt.. i�u i `t,'t � )I.. � ..i9i�.*'im.. ���.1'A"�Y.P. .yy-.,v'�)y �l 11VYl��vi.':l'I.0 _ Gh j Building Summary Loads Building peaks in August at 9am. 1dijs o"tlg�' SLR § *,,. iF Sen n xL. °/d Gof.; Let " , G eln �Ca a;•,r d ;1`��*'��F�is .n ain Roof 3,136 4,140 11.74 0 2,109 2,109 2.20 Wall 1,582 4,960 14.06 0 2,133 2.133 2.23 Glass 210 5,752 16.31 0 20,587 20,587 21.49 Floor Slab 128 2,619 7.42 0 0 0 0.00 Skin Loads 17.470 49.53 0 24,829 24.829 25.92 Lighting 6,272 0 0.00 0 21,401 21.401 22.34 Equipment 3,136 0 0.00 0 10.700 10,700 11.17 People 30 0 0.00 6,000 7,500 13,500 14.09 Partition 0 0 0.00 0 0 0 0.00 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 500 0 0.00 19,735 4,946 24,681 25.77 Heat. Vent. 500 17,804 50.47 0 0 0 0.00 Cool.lnfil. 0 0 0.00 0 0 0 0.00 Heat.lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 675 675 0.70 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 35,274 100.00 25,735 70.052 95,787 100.00 21��'�: tWSS:J�a>�i, Ventilation 17,804 Infiltration Pretreated Air 50.47 19,735 6 0 0.00 0 0.00 24,681 0 0 25.77 0.00 0.00 Zone Loads 17,470 6, 431 QO 70,431 73.53 Plenum Loads 0 0 0 0.00 Fan & Duct Loads 3b00!09%S01',E 0 0 675 675,0.70 Building Totals 35.274 25.736 70,052 95.787 100.00 !n/4� ,°.., y"'V f� 4` A.r , p..� IN\ e5s�.n. ^' Vk. � . �7 �,`y": N� <ti.' j'.+� Ji �, •'���i�{� �i\'h ' X �."5� A4:�.'�`xiv. �� PY*!.(� y.,��✓11, �",.ti'�"✓^4Myp` uh S .�i' Ian X. `.. P�..3}v R...,Y ..l �..7+Y:...._ i ea Y.+.^i •fi �[4 .: rt:....eY 5a.+:'U. �4U.4 vl `41� N, t.\'1ii4: �..+�r'['�. .: �ti,e :.. Total Building Supply Air (based on a 21" TD): 2,821 CFM Total Building Vent. Air (17.72% of Supply): 500 CFM Total Conditioned Air Space: 3.136 Sq.ft Supply Air Per Unit Area: 0.8995 CFM/Sq.ft Area Per Cooling Capacity: 392.9 Sq.ft/Ton Cooling Capacity Per Area: 0.0025 Tons/Sq.ft Heating Capacity Per Area: 11.25 Btuh/Sq.ft Total Heating Required With Outside Air: 35,274 Btuh Total Cooling Required With Outside Air: 7.98 Tons W:\...\Sleep City.CHV Friday, February 13, 2009, 11:31 AM �C ac,rpF�f11�Co%¢rclal HVAC}Loads CaleUlat bn Program `�, ;e.:y,x , a "� ��.+ IN ��..'� as�tjxay w �k�,EIReiSoRWaI� De eJopme,Mnt,,��,,lnvo2 t ,;�a$(1..y k j r '`ti-Yj.p,�i iyFyP,r'J'i'ai kfxd'�iY�1m\� 147gg...itj?Jnx4c SP$�I�iepa �,ji1�8tP�e5S<' Gw lku"bf:a Nrri'e.�,�u, ari.!`i1rt0.�i'"�'�+c�t!`,`�uFipB BEj�Z Air Handler #1 - RTU 1 - Summary Loads 11 +a, da rr L kg �i�k " e: ;- si , �. 4 p '. x+r Z[� �e Ctl toh AA7e �� �rHtg�Lo��A fSe �G tg�Lat�� �� C>S,R. Q'A>> ake i aktmI�` ►'�e 54 a t1(�. 2�8 ' M a, a , P.S.r. 3r.1�r r,Voltli .kMCS ��CF lift 1 Unit 1,568 8.735 32.215 3.000 Direct Direct gam August 15 405 1.410 0 250 250 18,816 0.26 0.90 0 250 250 Zone Peak Totals: 1,568 8,735 32,215 3,000 Total Zones: 1 15 405 1,410 0 250 250 Unique Zones: 1 18,816 0.26 0.90 0 250 250 Q CO W:\...\Sleep City.CHV Friday, February 13, 2009. 11:31 AM Air Handler #1 - RTU 1 - Total Load Summary Air Handler Description: RTU 1 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.13 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.91 --- This system occurs 1 time(s) in the building. --- Air System Peak time: Sam in August. Outdoor Conditions: 84° DB, 76° WB, 119.72 grains Summer: Ventilation controls outside air, ---- Winter: Ventilation controls outside air. Zone Space sensible loss: 8.735 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 8,902 Btuh 250 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 17,637 Btuh Heating Supply Air: 8,735 / (.999 X 1.08 X 20) = 405 CFM Winter Vent Outside Air (61.8% of supply) = 250 CFM Zone space sensible gain: 32,215 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 338 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible 'gain: 0 Btuh Total sensible gain on supply side of coil: 32,553 Btuh Cooling Supply Air: 32,553 / (.999 X 1.1 X 21) = 1,410 CFM Summer Vent Outside Air (17.7% of supply) = 250 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,473 Btuh 250 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: ® 2,473 Btuh Total sensible gain on air handling system: 35,026 Btuh Zone space latent gain: 3,000 t��� Infiltration latent gain: t Outside air latent gain: 9,86 Total latent gain on air handling system: ®®® 12,867 Btuh Total system sensible and latent gain: 47,893 Btuh Total Air Handler Supply Air (based on a 210 TD): 1,410 CFM Total Air Handler Vent. Air (17.72% of Supply): 250 CFM Total ConditionedlAirSpace: 1,568 Sq.ft Supply Air Per Unit Area: 0.8995 CFM/Sq.ft Area Per Cooling Capacity: 392.9 Sq.ft/fon Cooling Capacity Per Area: 0.0025 Tons/Sq.ft Heating Capacity Per Area: 11.25 Btuh/Sq.ft Total Heating Required With Outside Air: 17,637 Btuh Total Cooling Required With Outside Air: 3.99 Tons K\ ...\Sleep City.CHV Friday, February 13, 2009, 11:31 AM ChZac Full Comm Taal HVAC Loads Calculatiofn Program d ,.' "'<St s *w EII e�$oftW re;Develcpment i i; Air Handler, #2 - RTU 2 - Summary Loads r n ' 0 Ile, +. r a v� t d TM IQ'11'dae"F gaEB"i of yn ire8'+'"z?"eg �O$Si°`{?"'1"�G21i1r .b&"�''df+4t3'81i1 .'"� OK e h� M #4 r qP p i� f7ntRv ��(�rs�l1� fiy?v4� a $ h i t nF k WEIs Gt, b Po�fs�� �tM7S fi t,P�� sExH1 , Fe�G�F .� Aa �F 2 Unit 8 1,568 8,735 32,215 3,000 Direct Direct 9amAug irst 15 405 1,410 0 260 250 18,816 0.26 0.90 0 250 250 Zone Peak Totals: 1,668 8,735 32,215 3,000 Total Zog I es: 1 15 405 1,410 0 250 250 Unique ZIones: 1 18,816 0.26 0.90 0 250 250 I R CO i I I I WA ...\Sleep City.CHV Friday, February 13, 2009, 11:31 AM Air Handler #2 - RTU 2 - Total Load Summary Air Handler Description: RTU 2 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.13 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.91 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 84- DB, 76° WB, 119.72 grains Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air Zone Space sensible loss: 8.735 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 8,902 Btuh 250 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 17,637 Btuh Heating Supply Air: 8,735 / (.999 X 1.08 X 20) = 405 CFM Winter Vent Outside Air (61.8% of supply) = 250 CFM Zone space sensible gain: 32,215 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 338 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 32,553 Btuh Cooling Supply Air: 32,553 / (.999 X 1.1 X 21) = 1,410 CFM Summer Vent Outside Air (17.7% of supply) = 250 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2.473 Btuh 250 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,473 Btuh Total sensible gain on air handling system: 35,026 Btuh Zone space latent gain: 3,000 t Infiltration latent gain: 0 tt Outside air latent gain: 9,867 Total latent gain on air handling system: 12,867 Btuh Total system sensible and latent gain: 47,893 Btuh Total Air Handler Supply Air (based on a 21° TD): 1.410 CFM Total Air Handler Vent. Air (17.72% of Supply): 250 CFM Total Conditioned Air Space: 1,568 Sq.ft Supply Air Per Unit Area: 0.8995 CFM/Sq.ft Area Per Cooling Capacity: 392.9 Sq.ftrfon Cooling Capacity Per Area: 0.0025 Tons/Sq.ft Heating Capacity Per Area: 11.25 Btuh/Sq.ft Total Heating Required With Outside Air: 17,637 Btuh Total Cooling Required With Outside Air: 3.99 Tons W:\...\Sleep City.CHV Friday, February 13, 2009, 11:31 AM