Loading...
HomeMy WebLinkAboutFL ENERGT EFFICIENCY CODEFlorida Energy Efficiency Code. For Building Construcfion ; Florida Department; of Community;Affairs FLA/COM 2004 V2.5, EffectiVe Dec 8, 2006 -- Form 400A 2004R� , Method A Whole Building Performance Method for.Commercial Bu''ildings v PROJECT SUMMARY Short Desc: Sleep City Description: Sleep City Mattress Owner: Sleep City Mattress Addressl: Kitterman & US I City: Port St. Lucie Address2: State: FL Zip: 0 Type: Retail Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Conditioned Area: 3136 SF Conditioned & UnConditioned Area: No of Stories: 1 Area entered from Plans Permit No: 0 Max Tonnage If different, write in: SCgN�� Sr, Cuci� County 3136 SF 0 SF 8 EnergyGauge Summit@ v3.20 Incorporating Florida Energy Code Version - FI.A/COM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page I of 7 1 Component Gross Energy Cost Summary Design 4,157.9 LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? rtfS1 y � rw. Y Criteria Result 5,628.8 PASSES PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA EnergyGauge Summit@) v320 Incorporating Florida Energy Code Version - FWCOM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Eric J. Svoboda, PE Building Official: Date: 2- Z-5 .0 Date: I certify that this building is in co ce w' the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby ertify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: eg o: Mechanical Designer: OReg o: Plumbing Designer: Reg No: (*) Signature is required where F Aa a re 'F s design to be performed by registered design professionals. Typed names and rea ers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® v3.20 Incorporating Florida Energy Code Version - FLAICOM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 3 of 7 Project: Sleep City Title: Sleep City Mattress Type: Retail (WEA File: DAYTONABEACH.TMY) Buildine End Uses Design Reference Total 278.70 380.90 $4,158 $5,629 ELECTRICITY(MBtulkWhl$) 278.70 81528 $4,158 380.90 111462 $5,629 AREA LIGHTS 92.20 121.50 27010 35576 $1,378 $1,797 MISC EQUIPMT 69.00 69.00 20174 20174 $1,029 $1,019 PUMPS & MISC 0.20 0.20 3 32 $2 SPACE COOL 8 4 28110 31851 $1,434 $1,608 SPACE HEAT 4.00 3.80 1153 1124 $59 $57 VENT FANS 17.20 77.60 5046 22705 $257 $1,147 & Penalties (if any): Modified Points: = 278.31 PASSES EnergyGauge Summit@ v3.20 Incorporating Florida Energy Code Version - FLAICOM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 4 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: Sleep City Title: Sleep City Mattress Type: Retail (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance PrOZo1Sp1 25,001 Sales Area 3,136 6 2 PASSES PASSES Project: Sleep City Title: Sleep City Mattress Type: Retail (WEA File: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Co olu Nad No. of Units Sy em 1 Component Category &Ii6ttsign Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 I0.30 8.00 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 3.50 PASSES System PASSES EnergyGauge Summit@ v3.20 Incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 5 of 7 Plant Compliance Description Installed Size Design Min Design No Eff Eff IPLV Min Category Comp IPLV Hance None Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss Hance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] WO None LU EnergyGauge Summit® v3.20 Incorporating Florida Energy Code Version - FLAICOM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 6 of 7 .t: Sleep City Sleep City Mattress Retail File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 13-101 Input Report Print -Out from EnergyGauge F1aCom attached Operations Manual 13-102.1, Operations manual provided to owner 13-410,13413 Windows & Doors 13406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfin/ft'; all other products: 0.4 cfm/ft' Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls System 13-407 HVAC Load sizing has been performed Reheat 13-407.B Electric resistance reheat prohibited El HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D; Heating Tables 13-407.AB.3.2.IB, 13-407.AB.3.2.ID, 13-408.AB.3.2.IE, 13408.AB.3.2F HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating and cooling in each zone; combined HAC deadband of at least 5°F (exceptions) Ventilation Controls 13-409.AB.3 Motorized dampers regd, exce t g ers OK in: 1) exhaust systems and 2) syste wi d intake or exhaust capacity < 0 c ADS 13-410 t-anically i�g,�nd 'sign p ormed HVAC Ducts 13-410.AB ctttjngs, mec anical equipment & plenum chambers shall attached, sealed, insulated & installed per Sec. 13-410 Air Distribution Systems Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in construction documents Piping Insulation 13-41 LAB In accordance with Table 13-41 LAB.2 Water Heaters 13-412.AB Performance requirements in accordance with Table 13412.AB.3. Heat trap required Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); Readily accessible on/off switch Hot Water Pipe 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet Insulation pipe from storage tank and between inlet pipe and heat trap Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating Motors 13-414 Motor efficiency criteria have been met Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluuorescent lamps>30 W EnergyGauge Summit® v3.20 Incorporating Florida Energy Code Version - FLAICOM 2004 v2.5 Effective Dec 8, 2006 2/25/2009 Page 7 of 7 Project Name: Sleep City Project Title: Sleep City Mattress Address: Kitterman & US 1 State: FL Zip: 0 Owner: Sleep City Mattress EnergyGauge Summit® v3.20 0 Orientation: East Building Type: Retail g Classification: New Finished building o.of Stories: 1 GrossArea: 3136 SF Zones No Acronym Description Type Area [sf] Multiplier Total Area [sf] 1 PrOZol Zone 1 CONDITIONED 3136.0 1 3136.0 ❑ Spaces No Acronym Description Type Depth [ft] Width Height Multi IN [ft] plier Total Area [sf] Total Volume [cf] 2/25/2009 EnergyGauge Summit® Q.20 1 rione*zporls 1P Zo0SP1 Sales Area 49.00 64.00 12.00 1 3136.0 37632.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Lumihaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 1 5000 Manual On/Off 6 ❑ Walls No Description Type Width H (Effec) Multi Area irecti Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf F] Capacity [lb/cf] [h.sEF/Btu] [Btu/sf.F] In Zone: PrOZol 1 PrOZol Wal 5/8" stucco 64.00 12.00 1 768.0 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZOlWa2 5/8"stucco 64.00 12.00 1 768.0 We91067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: PrOZol In Wall: East 1 PCOZolWalWil UserDefined No 1.2500 0.82 0.76 3.00 7.00 11 231.0 El 2/25/2009 EnergyGauge Summit® v3.20 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value Vt] [ft] plier [sf] [Btu/hr. sE F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: PrOZol In Wall: West 1 PrOZoI Wa2Dr1 Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H (Effec) Multi Area *&Virt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] jde9 tsii PPhPPh��333333 Btu/hr. Sf. F] [Btu/sE F] [lb/cf] [h.sEFBtu] In Zone: PrOZol I PCOZolRfl Mtl Bldg Roof/R-19 64.00 49.00 1 3136.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W ffec) Multiplier Area Total Area [Btu/hr sf F] A [ft] [Sf] [sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo1F11 1 ft. soil, concrete 64.00 49.00 1 3136.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad 2/25/2009 EnergyGauge Summit® v3.20 Systems PrOSyl System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System 96000.00 48000.00 2880.00 0 8.00 7.1700 ❑ ❑ Plant Ice 4 Equipment Category Size NaMfNo Eff. IPLV Water Heaters W-Heater Description Description Rt Capacit3Cap.Unit UP Rt. Eff LossEl Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVft/No] [W] 2/25/2009 EnergyGauge Summit® v3.20 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ BtmWAffl [in] fnl u Fenestration Used Name Glass Type No. of CoGlass nductance SHGC 'VLT Panes [Btu/h.sf.F] VA ASHULSgIClrAlI User Defined 1 1.2500 0.8200 0.760 ❑ Frm Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtul IN [Btu/h.ft.Fl [lb/cfl [Btu/Ib.FI 187 MatI187 GYP OR PLAS No BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 MatI265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 MatI94 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N 2/25/2009 EnergyGauge Summit® v3.20 5 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLFJ [Btu/sf.FJ [lb/cfJ [h.sf.F/Btu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Th Framing No. Factor 1 268 0.625"stucco 0.0 1 0.000 El 2 42 8 in. Lightweight concrete block 0.667 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.062 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless C d t ce Heat Capacity Density RValue Construct Construct [ ] [Btulsf.F] [Ib/cfJ [hsf.F/Btu) 1056 Mtl Bldg Roof/R-19 Batt No No 1.34 9.49 20.3 ❑ ® Layer Material Material Thickness raming No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.FJ [Ib/cfJ [h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 2/25/2009 EnergyGauge Summit® v3.20 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sEF] [lb/ct] [h.sEFBtu] 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush (2.25") 0.000 2/25/2009 EnergyGauge Summit® v3.20 7 El