Loading...
HomeMy WebLinkAboutMISCSCgN N CO nty WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. WP 1200I GENERIC t HOUR 40to 44 STC FIRE SOUND GYPSUM WALLBOARD, STEEL STUDS One layer 5/8" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 3 518' steel studs 24" o.c. with 1" Type S drywall screws 8" , . •._„ . , , . .. .. ..,._... - ... . . o.c. at vertical joints and 12" o.c. at floor and ceiling runners and Intermediate studs. Joints staggered 24" on opposite sides. (NLB) -- - Thickness: 4 718" Limiting Height: Refer to Section IV Approx. Weight: 6 psf Fire Test: FM WP-45, 6-19-68; OSU T-1770. 8-61; ULC 79T484, 79T500, 79T497, 8-12-81, ULC Design W415 • Sound Test: NGC 2385. 7-28-70 WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. WP 1200 GENERIC GYPSUM WALLBOARD, STEEL STUDS One layer 518" type X gypsum wallboard or gypsum veneer base applied parallel or at right angles to each side of 3 5/8" steel studs 24" o.c. with 1" Type S drywall screws 8" o.c. at vertical joints and 12" o.c. at floor and ceiling runners and Intermediate studs. Joints staggered 24" on opposite sides. (NLB) 1HOUR FIRE WON 40 to 44 STC SOUND Thickness: 4 7/8" Limiting Height: Refer to Section IV Approx. Weight: 6 psf Fire Test: FM WP45, 6-19-68; OSU T-1770, 8-61; ULC 79T484, 79T500, 79T497, 8-12-81, ULC Design W415 Sound Test: NGC 2385. 7-28-70 WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. WP 1711 1 GENERIC 2 HOUR 40 to 44 STC GYPSUM WALLBOARD, STEEL STUDS FIRE SOUND Base layer 5/8" type X gypsum wallboard or gypsum veneer base applied parallel to..... - each side of 3 5/8" steel studs 24" o.c. with 1"Type S drywall screws 8" o.c. at vertical joints and 12" o.c. at intermediate studs. Face layer 5/8" plain or predecorated type X gypsum wallboard or gypsum veneer base applied parallel to each side laminating compound combed over entire surface. Metal base and top retainer channels. Joints staggered 24" each layer and side. (NLB) Thickness: 6 1/8" Limiting Height: Refer to section IV Approx. Weight: 10 psf Fire Test: UL R1319-31, 6-2-60, UL Design U411 Sound Test: RAL TL61-213, 7-6-61