Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSPLEASE PRINT. DO NOT COMPLETE SHADED AREAS.' DATE: PROJECT INFORMATION PROJECT ADDRESS: SITE PLAN/PROJECT NAME: SUBDIVISION: 0 1 i A.T� ��UGSf1SS LOT✓397 BLK: j �- �� , PROPERTY TAX ID #: g© ( -.. PARCEL -SIZE (ACRES -'OR SQ. FT.) z,, (4 LEGAL DESCRIPTION: OWNER NAME - ADDRESS: ADDRESS: oZ l}/i%' k-) I/V0G _D CITY: (i U (o g - STATE: ZIP ! �796 PHONE -IF THE LEE'SIMPLE'TITLEHOLDER-(PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED,ABOVE, PLEASE.. FILL IN NAME AND ADDRESS BELOW. FEE.SIMPLE,TITLEHOLDER: ADDRESS:r CITY:. df STATE:° —(-7 ZIP: d � o.DR1vRFQUI P DNO ivi1T Yes �— %L Ogg Init. C PERMIT INFORMATION pate ---• LOCATION: LOT SIZE DIMENSIONS: L�ZRSK f6 2.9 zz( c(4i.(SZci3iC BUILDING SETBACKS (ACTUAL):' FRONT % IIREAR _� J Z�� �Q R.SIDE D] ( (c5 L.SIDE (5 SQUARE FOOTAGE OF CONSTRUCTION:✓ 3 Z 9 / DESCRIPTION OF WORK: Z E if fl.o )--N PROPOSED USE-},..,_, TYPE OF CONSTRUCTION_: (CHECK ALL APPROPRIATE AREAS) RESIDENTIAL./ COMMERCIAL: INDUSTRIAL: OTHER: NEW CONSTRUCTION:— EXPANSION .OF EXISTING BLDG: INTERIOR REMODELING: OTHER (SPECIFY): EST. COSTi.—_7Fk9L?f S�`�,1IUE STATE OF FL RE9r/CERT---f C 9 C O 2 6 4?,Z COUNTY CERT #:` SOU CONTRACTOR NAME: <<�Z.r'j ADDRESS: iI��, Q. Q OC 6 OO CITY: 'L�6?= D 53pa STATE: / ZIP: �.�-9tiv5 PHONE�-7Y 0 ARCHIT/ENGINEER: ADDRESS: CITY: +Aim BONDING COMPANY: ADDRESS: STATE: PHONE 4: ( ) - CITY: ( STATE: ZIP: MORTGAGE LENDER: It ADDRESS: CITY: STATE: ZIP: SCANNED BY St, Lucia CAunty 3 RECEIVED FOR OFFkCE,}USE ONLY S r.LUClE COUNTY 1991 JUN _4 Pt' 2 45 PECIAL APPROVALS CDDNrrDEVEiVRfRED DATE RECEIVED VEGETATIONDRDINQjn� ENVIRONMENTAL PLANNING/SITE PLAN CODE ENFORCEMENT USA TAZ WATER SUPPLIER SEWER SUPPLIER DER CERTIFICATION _ FL DNR (CCCL) FL DOT SLC STORMWATER PER _ MANGROVE ALT SEA TURTLE PROT _ REQUIRED FEES PRr �1 z NOT REQUIRED O BP VALUE $ /3g,� PLANS EXAMINING FEE $_w�.-/ RADON FEE : ���q 7__ 9-� `7 ROAD IMPACT FEE $ aLOE) So ROAD IMPACT DISTRICT_Aa(A)L.A/,JIi ROAD IMPACT ZONE__ ROAD IMPACT CREDIT: YES: NO: SCHOOL IMPACT FEE $ -S—o DATE PAID: SCHOOL IMPACT CREDIT: YES: NO: SCHOOL BOARD APPROVED EXEMPTION: YES: NO: ALTERNATIVE DEV. FEE ALT. DEH. FEE ZONE: GAS AIR CONDITIONING ELECTRIC PLUMBING SCREEN ENCL/FENCE ROOF DRIVEWAY $ hJI & DATE PAID: SUB PERMITS NOT REQUIRED CHK# CHK# / ZONING CHECKS �BBL LOT COVERAGE EASEMENT LOT SPLITS ******************************************************************************* WATER HEATING BASE ___ __= AS -BUILT ------------------------------------------------------------------- - NUM OF x MULT = TOTAL I TANK VOLUME EF TANK x MULT x CREDIT TOTAL BEDRMS I RATIO MULT ------------------------------------------------------------------------------- 3 3319.0 9,957.00 I 50 .91 1.000 3208.0 .58 5,581.92 ******************************************************************************* SUMMARY ******************************************************************************* BASE __= I =_= AS -BUILT -------------------------------------------------------------------------- COOLING HEATING HOT WATER TOTAL COOLING HEATING HOT WATER TOTAL POINTS + POINTS + POINTS = POINTS I POINTS + POINTS + POINTS = POINTS ------------------------------------------------------------------------------- 31789.8 2914.2 9957.0 44,661.05 22027.8 1712.2 5581.9 29,321.83 ***************** * EPI = 65.65 ***************** 6 t WINTER CALCULATIONS BASE __= I =_= AS -BUILT ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- GLASS---------------- I ORIEN AREA x BWPM = POINTS I ------------------------------ NE 52.00 1.4 72.8 I I SE 218.50 -3.3 -721.0 S 18.00 -3.1 -55.8 SW 67.00 -3.3 -221.1 NW 114.00 1.4 159.6 TYPE SC ORIEN AREA x WPM x WOF = POINTS ------------------------------------------------ DBL TINT NE 36.0 1.8 1.29 83.7 DBL TINT NE 8.0 1.8 1.29 18.6 DBL TINT NE 8.0 1.8 1.29 18.6 SGL CLR SE 19.5 -2.1 -.82 33.6 SGL CLR SE 20.0 -2.1 -1.16 48.9 SGL CLR SE 92.0 -2.1 -.82 158.7 DBL TINT SE 18.0 -2.5 .72 -32.3 DBL TINT SE 69.0 -2.5 .72 -123.9 DBL TINT S 18.0 -2.4 .72 -31.0 DBL TINT SW 18.0 -2.5 .72 -32.3 DBL TINT SW 18.0 -2.5 .72 -32.3 DBL TINT SW 8.0 -2.5 .72 -14.4 SGL CLR SW 23.0 -2.1 -1.46 70.5 DBL TINT NW 60.0 1.8 1.29 139.4 SGL TINT NW 18.0 2.9 1.30 67.9 DBL TINT NW 12.0 1.8 1.29 27.9 DBL TINT NW 12.0 1.8 1.29 27.9 DBL TINT NW 12.0 1.8 1.29 27.9 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS I GLASS AREA AREA FACTOR POINTS POINTS I POINTS ------------------------------------------------------------------------------- .15 ------------------------------------------------------------------------------- 2,322.00 469.50 .742 -765.55-567.93 I 457.15 ------------------------------------------------------------------------------- NON GLASS------------ I AREA x BWPM = POINTS I TYPE R-VALUE AREA x WPM = POINTS ------------------------------------------------------------------------------- WALLS---------------- I Ext 1493.5 .3 448.0 I Ext NormWtBlock In 7.0 1493.5 .70 1045.4 Adj 212.0 .5 106.0 I I Adj Wood Frame 11.0 212.0 .50 106.0 DOORS---------------- I Ext 40.0 1.8 72.0 I Ext Wood 40.0 2.80 112.0 Adj 18.0 1.3 23.4 I Adj Wood 18.0 1.90 34.2 CEILINGS ------------- UA 2322.0 .1 232.2 FLOORS --------------- Slb 214.7 -2.1 -450.8 Under Attic Slab -on -Grade 30.0 2322.0 .10 2.9 214.7 -2.58 INFILTRATION--------- 1 2322.0 1.2 2786.4 I Practice #2 --------------------------------------------------------- --------------------------------------------------------- TOTAL WINTER POINTS I 2322.0 1.20 232.2 -554.6 2786.4 2,649.28 I 4,218.78 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TOTAL x SYSTEM = HEATING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 2,649.28 1.10 2,914.21 1 4,218.78 1.00 1.140 .356 1.000 1,712.15 6 ******************************************************************************* SUMMER CALCULATIONS BASE __= I =_= AS -BUILT GLASS=--------------- I ORIEN AREA x BSPM = POINTS I TYPE SC ORIEN AREA x SPM x SOF = POINTS NE 52.00 88.0 4576.0 SE 218.50 S 18.00 SW 67.00 NW 114.00 135.0 29497.5 124.2 2235.6 135.0 9045.0 88.0 10032.0 ------------------------------------------------ DBL TINT NE 36.0 78.2 .78 2207.8 DBL TINT NE 8.0 78.2 .78 490.6 DBL TINT NE 8.0 78.2 .78 490.6 SGL CLR SE 19.5 146.2 .35 1011.4 SGL CLR SE 20.0 146.2 .31 913.4 SGL CLR SE 92.0 146.2 .35 4771.6 DBL TINT SE 18.0 116.1 .74 1543.9 DBL TINT SE 69.0 116.1 .74 5918.4 DBL TINT S 18.0 107.7 .71 1374.1 DBL TINT SW 18.0 116.1 .74 1543.9 DBL TINT SW 18.0 116.1 .74 1543.9 DBL TINT SW 8.0 116.1 .74 686.2 SGL CLR SW 23.0 146.2 .28 941.5 DBL TINT NW 60.0 78.2 .78 3679.7 SGL TINT NW 18.0 94.5 .64 1088.6 DBL TINT NW 12.0 78.2 .78 735.9 DBL TINT NW 12.0 78.2 .78 735.9 DBL TINT NW 12.0 78.2 .78 735.9 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS I GLASS AREA AREA FACTOR POINTS POINTS I POINTS ------------------------------------------------------------------------------- .15 2,322.00 469.50 ------------------------------------------------------------------------------- .742 55,386.10 41,088.35 I 30,413.39 ------------------------------------------------------------------------------- NON GLASS------------ I AREA x BSPM = POINTS I TYPE R-VALUE AREA x SPM = POINTS ------------------------------------------------------------------------------- WALLS---------------- I Ext 1493.5 1.6 2389.5 1 Ext NormWtBlock In 7.0 1493.5 1.60 2389.5 Adj 212.0 1.0 212.0 I Adj Wood Frame 11.0 I 212.0 1.00 212.0 DOORS---------------- I Ext 40.0 6.4 256.0 I Ext Wood 40.0 9.40 376.0 Adj 18.0 2.6 46.8 I I Adj Wood 18.0 3.80 68.4 CEILINGS------------- 1 UA 2322.0 .8 1857.6 I Under Attic 30.0 I 2322.0 .80 1857.6 FLOORS--------------- I Slb 214.7 -20.0-4293.6 I I Slab -on -Grade 2.9 214.7 -17.49 -3754.0 INFILTRATION--------- I 2322.0 14.7 34133.4 I Practice #2 2322.0 14.70 34133.4 ---------------------------------------------------------------------------- TOTAL SUMMER POINTS I 75,690.09 I 65,696.29 -------------------------------------------------------------------------- TOTAL x SYSTEM = COOLING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT POINTS I COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 75,690.09 .42 31,789.84 1 65,696.29 1.00 1.140 .360 .817 22,027.76 ** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** COMPONENTS REQUIREMENTS PRACTICE #2 Comply with Practice #1 and the following. ------------------------------------------------------------------------------- Exterior Walls & Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor joint caulked or sealed. Exterior Walls & Penetrations, joints and cracks on interior surface Ceilings caulked, sealed, and gasketed. DuctWork Ductwork in unconditioned space must be sealed. Fireplaces Equipped with outside combustion air, doors, and flue dampers. Exhaust Fans Equipped with dampers. Combustion devices see 903.2 (f) . Combustion Appliances Provided with outside combustion air. b ** PRESCRIPTIVE MEASURES (Must be met or exeeded by all residences) ** ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- COMPONENTS SECTION REQUIREMENTS ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- _WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack. ------------------------------------------------------------------------------- EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area. Includes ADJACENT DOORS sliding glass doors, solid core, wood panel, insulated, or glass doors only. ------------------------------------------------------------------------------- EXTERIOR JOINTS 904.1 To be caulked, gasketed, weather stripped or other- & CRACKS wise sealed. ------------------------------------------------------------------------------- WATER HEATERS 904.2 Must bear label indicating compliance w/ASHRAE stand- ard 90 or comply with efficiency and standby loss re- quirements. Switch or clearly marked circuit breaker (electric), or cut-off (gas) must be provided. An external or built in heat trap must be provided. ------------------------------------------------------------------------------- SWIMMING POOLS 904.3 Spas and heated pools must have covers (except solar & SPAS heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78 ------------------------------------------------------------------------------- HOT WATER 904.4 Insulation is required only for recirculating systems PIPES In such cases, piping heat loss shall be limited to ------------------------------------------------------------------------------- 17.5 BTU/H/Linear Ft. of pipe. SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 gal- lons per minute at 80 PSIG. ------------------------------------------------------------------------------- HVAC DUCT 903.2 Constructed in accordance with industry standards & CONSTRUCTION 904.6 local mechanical codes. Ducts in unconditioned space must be insulated to minimum R-4.2 & joints must be sealed. ------------------------------------------------------------------------------- HVAC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. ------------------------------------------------------------------------------- INSULATION 904.9 Ceilings minimum R-19. Common Walls - Frame R-11 or CBS R-3. Frame Common Ceilings & Floors R-11. In Accordance with Sec. 553.907 F.S., I Review of the plans and specifications I Hereby certify that the plans and I covered by this calculation indicates specifications covered by this calcu- I compliance with the Florida Energy lation are in compliance with the I Code. Before construction is completed Florida Energy Code. I this building will be inspected for I compliance in accordance with Section o 1553.908 F.S. I OWNER/AGENT:�BUILDING OFFICIAL: DATE: DATE: