HomeMy WebLinkAboutSUBMITTED PAPERSALL APPLICABLE INFO MUST BE COMP _ EDTOR APPLICATION TO BE ACCEPTED nn
Date: �o�"�'I� Permit Number: lla V
SCANNED
BY
St. Lucie County
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential XXXXX
PERMIT APPLICATION FOR: Roof III
Address: 8610 MARY ANN LN. PORT ST. LUCIE, FL 34952
Legal Description: LA BUONA VITA COOPERATIVE UNIT/LOT 104
Property Tax ID q: 3426-664-0102-000-2
Site Plan Name:
Project Name:
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Lot No.104
Block No.
REMOVE EXISTING ROOF; REPLACE ANY ROT; INSTALL ASTM-226 30# UNDERLAYMENT;
INSTALL 26 GA METAL ROOF SYSTEM
CONSTRUCTION INFORMATION:
HVAC L _1 Gas Tank UGas Piping I—J Shutters
Electric 0 Plumbing Sprinklers 1:1 Generator
Total Sq. Ft of Construction: I_) O 0
Cost of Construction: $ 5,950
Sq��Ft.I of First Floor: _
Utilities: Sewer 1:1 Septic
QWindows/Doors
ZRoof
Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name JOAN GRENIER
Name: JOE BAKER
Address: 8610 MARY ANN LN.
Company: BIG LAKE ROOFING & REPAIRS
City: PORT ST. LUCIE State: FL
Zip Code: 34952 Fax:
Phone No.772-342-1649
Address: 2699 NW 16TH BLVD.
City: OKEECHOBEE State: FL
Zip Code: 34972 Fax: 863-763-7662
Phone No. 863-763-7663
E-Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
E-Mail: BIGLAKEROOFING@YAHOO.COM
State or County License: CCC046939
If value of construction is $2500 or more, a RECORDED Nbl:ice of Commencement is required.
Dec 02 1411:33a Big Lake Roofing $ Repel
r
863-763-7662 p.1
LIEN LAfiiV
..c.nvr�cry cnm:7C CK.- am Not Applicable
Name:
Address:
City: State:
Zip: Phone:
FEE SIMPLE TIME HOLDER: -v Not Applicable
Name:
Address:
City:
Zip: Phone:
MORTGAGE COMPANY: Not Applicable
Name:
Address:
city. State:
Zip: Phone:
BONDING COMPANY: Not Applicable
Name:
Address:
City:
Zip: Phone:
1 certify that no work or installation has commented prior to the issuance of a permit
SL Lucie County makes no representation that is granting a permit will authorize thepermitholder to build the subject structure
which is in con ict with any applicable Home Owners Association rules, bylaws or an covenants that may, restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
In accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoinga full concurrency review: room additions,
accessary structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may remelt in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted an the jobsite
before the first inspection. If you intend to obtain financing, consu@ with lender or an attorney before
rommpnrina .ern He t , rnmrdi..,. .,,.... w:..w.... _t n_______
cj ty-'-' N.. 3
Signature of owner/Agent/ Lessee.J...
Va
Signatar oI COnctor tense Hol er
STATE OF FLORIDA STATE OF FLORI1D M
COUNTYOF_I�1L�2/ Ll� pp COUNTYOF l K•e_,,_cl3abe-e
The forgoing Intro ent was acknowledged before me
this--1dayof�LcT o z01a bF
(Signature of Notary Pubfic- State of Florida )
Personally Known oR Produced Identification
Type of Identification Produced
Commission
Revised 07/15/2014
Theforgainginstru ent was acknowledged before me
this I dayof 2 8 ZD,�q by
(Name of person acknowledging)
(Signature of Notary Public -State of Florida)
Personalty Known _Y�-'_OR Produced Identification
Typeof Identification Produced
WIRES: Mey 21, 2018
LWAY.AARONNOTARY.COM
iSepjGGi K
2018
LIM!
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INMALS
VTAL CONSTRUCTION"LIEN-LAW INFORMATION:
Name:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: — Not Applicable
Name:
Address:
City:
Zip: _
Phone:
MORTGAGE COMPANY: Not Applicable
Name:
Address:
City: State:
Zip: Phone:
BONDING COMPANY: Not Applicable
Name: _
Address:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record.a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing work or recording vour Notice of Commencement.
Signature of Owner/ Agent/ Lessee
STATE OF FLORIDA
COUNTY OF
The forgoing instrument was acknowledged before me
this _ day of . 20 14 by
Signaturdrof Contractor/License H eofd r�
STATE OF FLORIDA
COUNTY OF B _Jt 6 ?t 2_e
The forgging'instru ent was acknowledged before me
this day of 2-GP b e 20_14 by
(Name of person acknowledging) (Name of person acknowledging)
(Signature of Notary Public- State of Florida) (Signature of Notary Public- State of Florida )
Personally Known OR Produced Identification Personally Known _�L OR Produced Identification
Type of Identification Produced Type of Identification Produced
Commission No. (Seal) Commission No. FEl R5 A I (o „ ,�(Se�ll�her
.ail : � �.._
n(�'Q�
a� , EXPIRES: May 21, 2018
Revised 07/15/2014 � 6 . `, wwwAARowNoTARY.com
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE H 4018134 OR HOC;' �94 PAGE 1941, Recorded 12/02/2014 0:51 AM
Permit No.
NOTICE OF COMMENCEMENT
Tax Folio No. 3azsbsa.oto2m0-z
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following Inform ion is provided in this Notice of Commencement
Legal Description of Property: (and street address if available):
LA BUONA VITA OOOPERAT M 1 NR T 06 FOBLUM&M R610 Mo, Ann Lam,
General description of Improvement:gERoor
Owner information or Lessee information Ifthe Lessee contracted for the Improvement:
Name JOAN GRENIER
Address QMQNBrtAuiol-ane Port St Lucle FIL 34952
Name and
COmraDoes Name: _BIG IANE ROOFING is REPAIRS
Contractor Address: im sLyp oKEEcHcR,EPhone Number: Eoa-P0a:
Surety (if applicable, a copy ofthe payment bond H attached): Amount of bond:$
Name and address: NIA Phone number
lender Name: N/A Phone Number.
Lender'saddress:
Persom within tha5tate ofFlarida designated byOw uer upon whom notices or other documents may be served as provided by Section
11L. I) (a)7., Florida Statutes:
Name. Phone Number.
Address:
In addition to himself., herself, Ownerdesignates of
Lienofs Notice as provided in Section 713.13(1) (b), Florida stattdes.
Phone number of person or entity designated by owner:
to receive: a copy of the
Expiration date of notim of commencement (the expiration date may not be before the completion of coratrui tioo and final Payment to the
centimeter, but will be 1 year fmmthe date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BYTHE OWNER AFTERTHE EXPIRATION OF THE NOTICE OF COMMENCEMENTARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTSTOYOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IFYOU INTENDTO OBTAIN FINANCING, CONSULT WITHYOUR LENDER OR AN ATTORNEY BEFORE COMMENONG WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Underpe tyof perjury, I declare that l have read the foregoing notice of commencement and that the facts stated therein are time to the best of
myk a eandbelief.
c�9g r� -40k Heger Nato
(Agnat. aTl a/Office) 41 a C81g1I68lONOFIM16
The fo n inst�mmentwas acknowl $� ' 21, 2016
regoi g" edged 6eforemeth's dayof f�e.L. , 20� y i WMW.ANIONNBTAM.Gkb
Byc�DGLYT lnfCrlle�' as for
I Name�of.PPerson o Type of authority (e.g. officer, trustee) Parry on behalf ofwhom instrument was executed
Personally krcwn1Or produced Identification_
(Signature of Notary Public - State of Florida)
(Pent, Type, orStamp Commissioned Name of Notary Public) Type of Identification produce
STATE OF FLORIDA
ST. LUCIE COUNTY
THIS IS A CERTIFY THAT THIS IS A
TRUE A4b P111EIT COPY OF TH
ORIGIN
V
IT
By. 0
uty clerk
Dato: 2
Carl E Arrington Record: 1 of I
Proper[) Identification
Site Address:
8610 Mary Ann Ln
Sec/Town/Range:
26 :36S :40E
Map ID:
34/26S
Zoning:
RMH-5
PROPERTY RECORD CARD
«Prey Next» Spec.Assnmt faxes
PatcellD: 3426-664-0102-000-2
Account #: 1 146060
Use Type: MobHome-Coop
City/Cnty: Saint Lucie County
Exemptions Pcrmits [ionic Pnnt
Ownership and Mailing- Legal Description
Owner: Carl E Arrington Bonnie Arrington LA BUONA VITA COOPERATIVE UNIT/LOT 104 (OR 1954-82)
Address: 8610 Mary Ann Lane
Port St Lucie FL 34952
Sale° Int'orma[ion
Date Price Code
4/16/2004 28500 01
5/31/2001 4450000 02
Assessment 2014
Deed Book/Page
2014 TRIM:
38800
MS 1954 / 0082
Assessed:
38800
WD 1398 / 1783
Ag.Cro it:
0
Exempt:
25000
Taxable:
13800
Taxes:
295.66
BUILDING INFORMATION
Exterior features
View:
- RoofCova: -
ExtType:
MHA - MHA Y=Blt: 1987
Grade:
LABV - LaBuo=V MH EfiYrBit: 1987
StoryHght:
0010 - 1 Story No.Units: 1
Interior Features
Total Land and Building
Land Value:
15000 Acres: 0.05
Building Value:
23800
Finished Area:
1376 SgFt
Roo64tmct: -
Fru ne:
PrimeWall: -
SecWall:
BedRooms: 0 Electric: - PnnhuWall: -
FullBath: 0 HeatType: FHA - FrcdHotAir AvgHt/Fl:
1/2Bath: 0 HeatFuel: ELEC- Electric Pmt.Flors: -
%A/C: 100 %Heated: 100 %Sprinkled: 0
Special Features and Yard Items Land Information
Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth
1 0205-MobHome-Coop I l l Site 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
iussen Engineering LLC-�-
Engineering & Environmental Services
P.O. Box 1998, Okeechobee, FL. 34973-1998 Office: (863) 763-8546 Fax: (863) 467-8560
Memorandum
Date: December 7, 2014
To: St. Lucie County Building Department
Joe Cicio — Building Official
2300 Virginia Avenue
Ft. Pierce, FL. 34982-5652 1
e CO
yy,�
From: Loris C. Asmussen, P.E. ®P.P
Subject: Joan Grenier
8610 Mary Ann Ln.
Port St. Lucie, FL 34952
1987 DEL ORO (24' x 52') Vehicle ID — 2D-9192 A/B
This memorandum is provided to address re -roofing of a 1990 Jacobson mobile home. Proposed is
Gulf Rib Roof Paneling (26 GA metal — FL I I651.22R1) as a replacement for the originally
manufactured roof. Tamko Underlayment (30# ASTM D 226) will be used. Attached are product
approvals for the paneling (#I1651.22R1) and underlayment (FL12328-R2), which includes
attachment methodology for the rib panels and underlayment. The panels are manufactured by Gulf
Coast Supply & Manufacturing, Inc. The Engineer Evaluator of the paneling is Terrence E. Wolfe
(FL. P.E. No. 44923) and the Validator is Locke Bowden (FL P.E. No. 49704).
Based on my review of this proposed project, including product approvals and loads for which the
above -referenced structure will be exposed to at this location in St. Lucie County (160 mph 3-
second gust and exposure "C"), the project is found to be in substantial compliance with the 2010
Florida Building Code.
Any plywood, found to be damaged or in disrepair, will be replaced and fastened in a manner
similar or equivalent to that employed during manufacture of the original structure.
Sincerely,
Loris C. Asmussen, P.E.
Principle
C: Grenier File
Flo da Deoartment9 BCIS Home 1 lag in I User Registration I Hot Topics I Submit Surcharge I Stats a Facts I Publications FBC Stall 1 BCIS Site Map I Unks Seard
i
Product Approval
USER: Public User
Product A00M Vet Menu > P,ndoR or
Application Search > Application 115t > ApplIcation Detall
FL #
FL12328-R3
Application Type
Editorial Change
Code Version
2010
Application Status
Approved
Comments
Archived
O
Product Manufacturer
TAMKO Building Products, Inc.
Address/Phone/Emil
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
keni_eden@tandm.com
Authorized Signature Keni Eden
kerrteden@tandm.com
Technical Representative Kerr Eden
Address/Phone/Emil PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerr_eden@tamko.com
Quality Assurance Representative
Address/Phone/Broil
Category Roofing
Subcategory Undedayrrents
Compliance Method Test Report
Testing Lab
PRI Construction Materials Technologies, LLC
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
02/26/2016
Validated By
Robert J. M. Nierrinen, PE
e Validation Checklist - Hardcopy Received
Certificate of Independence F1-12328 R3 COI PRI CMT Cert of Independence. odf
Referenced Standard and Year (of Standard) Standard
ASTM D1970
ASTM D226
ASTM D4869
ASTM D6380
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option B
Date Submitted 03/04/2013
Date Validated 03/1112013
Date Pending FBC Approval 04/15/2013
Date Approved 06/11/2013
Z
Year
2101
200
2005
2003
BUILDING
UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be
applied over the entire deck before the installation of TAMKO shingles. Apply the felt
when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the
eaves lapping each course of the felt over the lower course at least 2 in. Where ends join,
lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by
moisture and weathering. Laying of the underlayment and the shingle application must be
done together.
CORPORATE HEADQUARTERS
220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641.4691
tamko.com
swu-anoa
accasarrsa
Report for:
Attention:
ALI
UCTION MATERIJ
TECHNOLOGIES
I=MORATORY ;TESTREPORfi ;'_
Tamko' Building Products, Inc.
220 W. 4th Street
Joplin, MO' 64802
KeniEden
.Date: January 8, 2009
Product Name:
No. 30 ASTM
Manufacturer. Tamko
Date Received:
December31, 2008
Source: Tamko
PRI Report No.:
TAP-215-02-01
Metro -Dade Notification No.: PR108122
Subject: The purpose of this project was to performance properties of Tamko Building Products No.
30 ASTM (No. 30, Type II) asphalt felt for compliance with Florida Building Code 2004 and
2007 (HVHZ) Testing Application Standard (TAS) 110-2000: TESTING REQUIREMENTS
FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND
OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up
and modified bitumen roof assemblies, and. Florida Building Code 2004 and 2007; Sections
1507'.2.3, 1507.3:3; 1507..5.3, and 1507.7.3: Underlayment using ASTM D 226-97a and
ASTM D 226-06: Standard Specification forAsphalt-Saturated Organic Felt Used in Roofing
and Waterproofing, Type II.
Test Methods: The test methods used included those found in FBC TAS 116-2000: TESTING
REQUIREMENTS FOR PHYSICAL PROPERTIES OFROOFMEMBRANES, INSULATION,
COATINGS, AND OTHER ROOFING COMPONENTS and including: ASTM D 226: Standard
Specification forAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing; ASTM D
146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven
Fabrics for Roofing and Waterproofing; ASTM D 727: Test Method for Kerosine Numberof
Roofing and Flooring Felt by the Vacuum Method.
Sample The sample received from Tamko Building Materials on December31, 2008 was a full factory
Description: labeled roll of felt
-TAP-215-02-01 PRI Accieditwions:lAS-ESTL-189:S1ateof FlcddaTST5878:M&tr Dade08-1116.02:CRRC
The test results, opinions, or interpretations are based on the material supplied bythe client This reportis forthe exclusive use of stated
diem. No reproduction orfeceimile in anyfono can be made without the clients pemrission. This reportshall nor be reproduced except in
full wilhoutthewriften approval of this laboratory. PRl Construction Materials Technologies, LLC. assumes no responsiTxTdynormakes a
performance orwarrany statement for this material or products and processes containing this material In connection with this report
PWCer*Mfxr1lJWM1esTMhr0lWw.LLG 6WRalgerfte Ta=FL33610 Tet8138 -TM Fac813Ql.5 8 ";kaL�Q*mim Weh;iscMWVmw0brLcm
Tsmko Building Products -
Laboratory Test Report for No. 30 ASTM Saturated Fell
PRI0t1122 -
Page 2 of 2
Results of Testln :
Property
ASTM Test
-
Result ASTM D 226 .11
..
Requirement
5- Materials and Manufacture
D 226
Pass Free of Lumps panicles or foreignstances
subor
6. Physical Requirements
Average breaking `strength, Ibf/in
D 146 XN .."
'x
MD
69
40 min
CMD
28
20 min
Pliability @ 77°F
D 146
Pass
No cracking
Loss on heating @ 2217, %
D 146
2.7
4 max
Width of roll, in
D 146
36.0
363 0 T{gtir as;agreed i
Area of roll, ft.2
D 146
216.7
16 or432 tr(i Rra 9------
Moisture at point of manufacture, /o
D 146
3.2
Net mass of saturated felt, Ib/100 fe
D 146
28.0
Mass Ib/100
D 146
17.4
of saturant,
Mass of desaturated felt, Ib1100 fe
D 146
10.8
R
-
Ash, %
D 146
4.6
Saturation, %
D 146
6.2 Unroll @ 50 and 140OF
D 226
Pass
it3 i '
6.3 Perforated felt
D 226
7 Workmanship, Finish,
D226
r "
Pass
Appearance
y
Note 1: Or as agreed upon by purchaser and seller.
Statement of Compliance:
This product complies with all of the requirements of Florida Building Code 2004 and 2007. (HVHZ).Testing
Application Standard (TAS) 110-2000: TESTING REQUIREMENTS, FOR PHYSICAL PROPERTIES OF
ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2:
Roofing Components within asphalt built-up and modified bitumen roof assemblies, and Florida Building Code
2004 and 2007: Sections 1507.2.3,1507.3.3, 1507.5.3, and 1507.7.3, Undedayment using ASTM D 226-972:
Standard Specification fol-Asphalt Saturated Organic Felt Used in Roofing and Waterproofing, Typell. The
product also complies with all of the requirements of ASTM D 22"S. Standard Specification for Asphalt -
Saturated Organic Felt Used in Roofing and Waterproofing; Type II. Limitations: None.
Signed
Donald C. Pdftlio
President
Date:'
Signed•
Due T. Ngul
Florida Registered Prof ional Engineer
P. E. Number. 65034
The test results, opinions, or interpretations are based on the material supplied by the client This report is forthe exclusive use of stated
client No reproduction orlacsimile in anyfdrm can be made withoutthe clients permission. This repodshallnotbereproduced except in
fullwithoutthewrittenapprovalofthislabomtory. PRlConstruction Material&Teehnalogies.LLC.assumesnoresponsrbiritymrmakme _
performance orwarranty statement for this material or products and processes containing.this material in connection with this report
PNC=MWMklaelah TmVOogk%LLC.64WBWFrbrive Tared FL37ata Ta:e13c214M Face1sa21-seas e4na0m&d&tasS @pnammn websuekupJ1*—Vlwm
TAMKOO M0930 U16 PRODUCT DATA
Asphalt Saturated Organic Felt
Manufactured in Joplin, MO, Frederick, MD,
and Green Cove Springs, FL
TAMKOO NO. 30 UL SATURATED FELT
features a tough TAMKO organic felt that is
saturated with asphalt.
Accepted for use as an underlayment felt to be applied
over the roof deck prior to the installation of TAMKO
asphalt shingles.
U.L. Built -Up Type 30 Label
ASTM D 226, Type II
PRODUCT DATA*
Roll Dimensions 72' X 36"
Coverage per roll 2 Squares
Laying Lines 2", 4", 17"
'All values stated as nominal
THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Visit our Web Site at tamko.com
i A��Sa1V
Central District
220 West 4th St.
Joplin, MO
64801
800-641-4691
Northeast District
4500 Tamko Dr.
Frederick, MD
21701
800.368-2055
BUILDING PRODUCTS
Southeast District
2300 35th St.
Tuscaloosa, AL
35401
800-228-2656
Southwest District
7910 S. Central Exp.
Dallas, TX
75216
800-443-1834
TAMKO Logo, Roofer Logo and TAMKO"
Western District
5300 Fast 43rd Ave.
Denver, CO
80216
800-530-8868
are registered trademarks of
TAMKO" building Products, Ina
In(mmarnerincluded! in this
product data sheet was
at time of pdmkg. To "Maln a copy ct
the
on es ont
most cvrtent version of this product data sheet, Nsd us onGna
at tamko.wm or call us at 900E41-4691.
Rev.15 012
Force Engineering & Testing Inc.
19530 Ra blewood Dave
14 mhle,TX 77338
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. Tuff Rib Roof Panel over 15132" Plywood
Florida Product Approval # 11651.22 R1
Florida Building Code 2010
Per Rule 9N-3
Method: 1—D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 9N-3.005(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY & MANUFACTURING, U.C.
4020 S.W. 4491h Street
Horseshoe Beach, Florida 32649
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validato
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1-4
AO h
,,,�ltunrHt��i
H.c ELU
,
NO. 449W
'q• STATE OF
�iO,c`• ALORI9A.�4.,.�
,;� I�OItl1 �►t�?,,,
FL# 11651.22 R1
February 22, 2012
Compliance Statement:
Product Description:
Force Engineening & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
The product as described in this report has demonstrated compliance with the
Florida Building Code 2010, Sections 1504.3.2.
Tuff Rib, %" Rib Roof Panel, Min. 26 Ga. Steel, 36" Wide, through fastened roof
panel over 15/32" Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2010, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0185" min.
Width: 36"
Rib Height: ''/." major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
Substrate Description:
Design Uplift Pressures:
FL# 11651.22 R1
#9-15 x 1-1/2" HWH Woodgrip with sealing washing or approved equal
W minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1S07.4.4
Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2010.
Table "A"
Maximum Total Uplift Design Pressure:
69.25 psf
159.25 psf
6.5"-2.5"-6.5"-2.5"-
Fastener Pattern:
9"-9"-9"-9„
6.5"-2.5"-6.5"
Fastener Spacing:
24" O.C.
12" O.C.
-Design Pressure includes a Safety Factor= 2.0.
\II III8"J",
C E• E• �;p �,i
G E t4
•d STATE OF ;
LORI9A
February 22, 2012
rForceEngineering esting Inc.
19530 Ramblewood Drive
Hu ble,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010, Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010, as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL1897-04- Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No.117-0062T-07A, B, Dated 02/19/2007
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency: 1. The UL580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Underlayment: Per Manufacturers installation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
ttrr11814,
E. E wp ii�i
C E Alg
16
ND. 47 4/*
C f
\J ' STATE OF :or
smarrms �� Fs; . L 0
ONAL' 1 r f t t ?,,,`
FL# 11651.22 RI
February 22, 2012
r��
Force Engineering & Testing Inc.
19530 Ramblewood Dore
Humble,TX 77338
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
FL# 11651.22 RI
,sµturrttII.,
♦`� f t\C E' E J. p 'It,No. 47
r STATE OF ; rc
r Iy
'.off AL O RI I A ++�
smarm► r� A 1 ��
aD� � •r/ . • .... �`�
Arj, Or1r11113`NAL %,
February 22, 2012
f/
Ridge caps (pg. 9)
Eave drip (pg. 8)
Valleys (pg. 12)
Gable rakes (pg. 11)
Sidewalls (pg. 11)
Endwalls (pg. 10)
Lei r12
Transition & gambrel
tlashings (pg. 10)
Comer trims (pg. 13)
V
Door & window
trims (pg. 14)
Base drip (pg. 14)
s
Pipe Boot pg. 11)
.� t _
Electrical Boot
Inside Closures
f
®
Flex-o-vent
®
Profile Vent
Expanding
Foam
a
Peel and Seal
® '
m
Touch-up Paint
Outside Closures
rik
Butyl Tape
Solar Seal
Foil -backed thermal
barrier insulation
Woodgrip Screws
Lap TEK
TEK screws
WoodMac screws
Guide to Misc. Accessories
aem
pipe boot
Fits over vent and heat pipes. Available also in heat -resistant boots.
electrical boot
Fits around pipes with inaccessible tops (such as weatherheads).
outside closures
Required to seal under ridge caps and transition and end wall flashings.
inside closures
Seals under panels, particularly on the eave.
Profile Vent® Flex-o-Vene
Vented closure material surpassing many other venting systems.
expanding foam
Compressed adhesive foam expands to seal between valleys and panels.
Peel and Seal"
Seals hips under hip caps. Also, a general purpose sealing tape (6" wide).
touch-up paint
Hides scratches and mars encountered in installs_ tion. Over 20 colors.
butyl tape
General purpose low-cost sealant, used on panel laps and under trim.
Solar Seal®
A superior general purpose caulk for all joints. Matches panel colors.
Low profile insulation
Greatly reduces radiant heat when installed under panels.
Woodgrip screws
Used in all applications attaching metal to wood. 1", 11/2", 21/2" sizes.
TEK screws
Self -drilling TEK screws for metal purlins. Lap TEK screws draw
together joints and attach trim.
ZACO screws
"Lifetime" screws; 11/2", 21/2", threaded for wood; self -drilling available.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-16-
J
/`
GuIfCoa'st
SUPPLY & MANUFACTURING
DETAIL
MANUAL
and guide to Gulf Coast products
Gulf
nels &
ng and Sid
ccessories
4020 SW 449th St • Horseshoe Beach, FL 32648
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
www.gulfcoastsupply.com
G61 MEs"t
Figure 1 The Gulf Coast Supply office (left) and manu-
facturing facility.
The Gulf Coast Gulf Rib°
Roofing Panel
Gulf Coast Gulf rib' panels are a strong,
durable, economic, and attractive answer to
the growing demand for metal roofing needs
in Florida and southern Georgia. Extremely
versatile, they are suitable for homes and
businesses as well as agricultural and utility
buildings Gulf Rib' panels provide a 36-
inch coverage with 3/4 inch ribs on nine -inch
centers, and utilize an anti -siphoning channel
to provide protection from severe weather
conditions. Both panels and trim are fabricated using
state-of-the-art computerized equipment found at our
facilities in three locations in Florida, to assure
uniformity and consistency in product manufacture.
Panels are roll -formed to the lengths specified by
customers in either Galvalume or any of more than
twenty colors of painted 29-gauge, 26-gauge, and
24-gauge-high=tensile-metal ' ready -for either cus-
tomer pickup or on -site delivery (customers should
call about availability of 24-gauge metal). Your
Gulf Coast representative is waiting to assist you in
making the best choice for your particular roofing
needs.
Gulf Coast's Gulf Rib' panels are fabricated
from AZ-50 (painted) or AZ-55 (bare Galvalume) Figure 2 Facilities located in Horseshoe Beach,
grade 80 coil stock (grade 50 for 24 gauge). The Alachua, and Stuart, Florida
bare Galvalume finish is not only durable and cost effective, but offers reflectivity so valuable
here in the South. The paint system employed on painted
products offers optimum exterior protection plus superior
resistance to corrosion and ultraviolet radiation.
While bare Galvalume carries a 25-year
limited coil manufacturer's finish warranty,
Figure 3 The Gulf rib panel most painted metal carries a 40-year war-
ranty. Both painted and unpainted are of the
highest known quality in the industry.
Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet
every need of both the do-it-yourself homeowner and the roofing contractor. A complete line of
both in -stock and custom-made flashings and trims are available in all colors as well.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-2-
G61 Mol�k SU ly &Manufacturing
Gutters ►
Gulf Coast Supply produces 29-, 26-, and 24-
gauge gutters in either 5- or 6-inch widths (depth is
approximately equal to width). All gutters
should be ordered specific to the pitch of the
roof. Downspouts are available in Yx4" (for 5-
inch gutters) and 4"x4" (for larger gutters). End
caps should be ordered at the same time as the
gutters to assure a custom fit. Special hangers fit
into the panel rib and under the gutter lip. Panels
should extend no more than 1" to 1�/i' inches
beyond the eave on which gutters are planned.
lap screwy
�_ 5 or 6"� , a e1
Gutter hangers fit inside
Figure 21 Exposed view of gutter showing gutter hanger
placement, downspouts, and end caps. Hangers employ lap
screws, and end caps are best attached with rivets.
panel rib and under lip -''— „ '-
of gutter (apply at least i 0uter,`3 Inner - Outer - Inner >Out.
one per panel) and are Inner and outer gutter sections (marked "I" and V
attached with lap screws alternate along the eave to assure ease of application and
or rivets. gutter appearance.
Downspout p uo tuo is in excess of 10 feet in length must
)emadein2sections. - - - -
Door
Figure 22 Sliding door track covers fit over the door track and
under the panels to hide the track, assure a neat appearance, and
shed water over the door.
t Track Covers
�I
I TC-1
a sliding door
® track cover
21/2„
Door
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-15-
r r (c 6
I t
frip cap
1
i
c I j_cfiannel
f
Figure 19 The drip cap is commonly used to trim out the bottoms of panels
over doorways and windows, and occasionally takes the place of base drip.
J-channel is used to cap raw panel edges where run-off is not a problem, and
is most commonly used to trim around the bottom, sides, and occasionally the
top of windows and doors, and also to cap the top sides of skirting.
Base Drip
BD-1
Base drip
pool
' Drip Cap and
J-Channel
DT
Drripip cap � T v
%" CD
capping the panel end
JC-1
J-channel
a
panel rk"
21/4`—�
capping,tthe panel edge
r ' l
' A,
i
k�
� g
r� /'--
i"n
Figure 20 Base drip seals off the bottoms of panels at the floor level, where
it helps to prevent the entrance of rodents and insects, as well as a base for
the setting of panels.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
Installation of Panels
Roof Pitch
Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage.
Florida Building Code allows a minimum pitch of 2/12 for Gulf Ribs panels as long as lap screws
and sealant are applied to the laps to prevent water from siphoning over the ribs (see Fig. 5 on p. 4).
Lap screws and sealant are optional when the pitch is 4/12 or greater (4/12 pitch means that there is 4
inches of rise for every 12 inches running horizontally). As a general principle, the less steep the roof,
and the more necessary also that sealant be used at all side -laps. Consult our representative for
recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12
pitch.
Roof Preparation
Oil -canning is a wave -like, rippled appearance extending up the length of the panel after it has
been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped
plywood, uneven trusses, poor application of underlayment, the use of button caps with felt paper, etc.,
can promote oil -canning. Care should be taken to provide a flat, uniform surface on which to attach
the panels. See page 6 for more details.
Roof Application
Panel installation should begin at the gable end of the roof opposite the prevailing rain -bearing
wind (this will provide added assurance against wind -driven rain being forced under the laps). Measure
one panel width in from the roof edge. At this point chalk a line from ridge to cave. Place the leading
edge of the first panel along this line. It is extremely important that this panel be laid square to the eave
and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person
at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof.
Also be sure that the panels are properly side -lapped (seefig. 7 on page 7).
In applications where end -lapping is necessary, the upper panel on the slope should lap over the
panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of
panel overlap. All end -lap applications should use two horizontal rows of butyl sealant tape across the
panel and proper fastening to provide a maximum water seal.
An overhang of 2 to 3 inches on the cave is recommended to provide a drip edge, while only 1
inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with
inside closures. For maximum weather -tightness, a row of butyl tape can be applied above and beneath
closure material.
Irinuning and Cutting Steel Panels
The best device for cutting steel panels across the profile is either hand snips or a nibbler.
Nibblers, and especially Carborundum blades on electric saws, however, do have a tendency to either
leave hot metal particles that can bum paint surfaces or to leave rust marks on panels and trim. The
same is true of any filings left on the roof caused by the application of screws. Care should be taken to
brush all such particles from roof surfaces after application.
To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge,
score deeply down the length of the panel with a sharp -pointed utility knife. Folding the panel along the
score mark, and bending back again if necessary, should produce a clean break in the panel.
CAUTION! clean all metal shavings and particles off of roof to avoid unsightly rust stains
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-14- -3-
GUIK06�t SY turinl.
pppt Manufacturim
Residential Trim
Seep. 12 for Siding Trims
Roll Lite Door
Figure 4 Roofing trims and flashings are named by the
location or function of that particular piece on the building.
Vallev
Figure 5 Butyl tape or caulk is required when the
roof pitch is 3/12 or less, with lap screws applied
every 2 feet to maintain water -tightness of the lap.
On pitches greater than 3/12, lap screws and butyl
tape are optional. For more details on screws,
see pgs. 6 and 7.
GR-2 Outside Corner
The GR-2 Rake and Corner can be used as a
gable trim or a corner for metal -sided buildings.
As an alternative, the smaller EF-I or the GR-1
(both on p. 11) can also used as gable rakes, and the
PC-5 (below)or the GR-1 as corners.
Customizing rakes or comers is often necessary
due to their landing on a panel rib. Both the GR-2
and the IS-2 can be ordered as custom trim items
by specifying custom dimensions "a" or "b". Be
sure to take into account the 3/a" "head space" when
figuring custom dimensions.
The PC-5 flat corner
panel
works best on smaller
3°
structures, and where
the panels are running
outside
horizontally. It can be
glosure
sealed with outside
closures.
a
ffl
1
Figure17 When used as corner trim, the GR-2 straddles the ribs
of the panels where they meet at the corner of the building. The
Gulf Rib outside corner also serves as a gable rake (see below).
The inside corner (IS-2) has similar dimensions but with a
reverse middle bend.
Figure 18 When used as a gable rake, the GR-2 runs parallel to the ribs of
the roof panel, and is attached with screws running through the ribs of
upright siding. As with the EF-1 residential rake, the roof side can be
sealed with butyl sealant.
GR-2 Gable Rake
6"
�q sis"
4
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852 (352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-4- -13-
Preformed
Valley
Install panels 2 to 4"
from diverter
panel _
PV-1 style a
PV-2 style
Two basic styles of valley are available.
For custom valleys, specify dimension "a"
Figure 15 Pre -formed valleys use a diverter to prevent water
from rushing under panels on the opposite side, while
meanwhile channeling water off the roof. Expanding foam
closures are often used to assure a good seal.
Gulf Coast Gulf Rib° Siding
Figure 16 Common trims associated with Gulf Rib roofing panels
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-12-
G6il Cast
Ordering Roof Panels and Screws
Care should be taken to order panels of the correct length to avoid having to make
corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when
a vented ridge is desired, and should extend 2 to 3 inches past the cave to allow a sufficient drip
edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of
the upper portion should be ordered short to allow placement of the transition flashing (see
diagram on p. 10). The Gulf Coast sales personnel are ready to assist customers with information
specific to their particular roof.
Specially-washered screws applied through the flat of the metal is the most recommended
method used to attach roofing panels. 1-inch screws can be used if penetration of only 3/ inch is
either necessary or desired; otherwise, lr/2 inch screws are usually recommended. 2r/2 inch screws
are also available, and are often used by those who adhere to through -the -rib fastening, and for
ridge -cap application. See pages 6 and 7 for more information on screw spacing and ordering.
Ordering and Applying Trim
The most common flashing for metal roofing is the ridge cap, which is used at the peak of a
roof where two opposing roof slopes join. Other flashings include transition flashing, end wall
and sidewall flashings, and valleys (see diagram on right for application). Eave trims include
gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch
exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering
ridge caps, endwalls, and cave drip. When a steeper roof slope meets a lesser slope, both slopes
should be mentioned when ordering transition flashing.
At the gable edge the use of gable trim adds to the appearance of the structure and protects
the fly -rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent
wall. In either case, the installer should be careful to seal between the gable rake or sidewall and
panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with
the appropriate screws. If cave drip is used on the gable, the number of 90 degree cave drip
should be specified separately from that used on the drip edge when ordering.
To prevent penetration of water, insects, and debris at the ridge, outside closures should be
inserted between the ridge cap and the top end of the panel. Screws are applied through the ridge
cap, closure, and rib in at least every other rib of the panels. At least a lr/2" (or preferably 2t/2")
screw should be used for attaching ridge caps. Self -drilling lap screws can also be used to attach
ridge caps.
Keep Materials Dry!
Paint and finishes of Gulf Coast panels and trim are designed to withstand severe rain and
wet weather conditions. Neither paint, galvanized, or Galvalume finishes, however, are designed to
be in continuous contact with water for long periods of time. Damage will result if uninstalled
panels or trim are allowed to remain wet in storage. Be sure to store material that will not be
installed immediately in a dry location. Wet material should be air-dried and re -stacked if
installation is not planned right away.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-5-
Guif23M'k ' U & Manufacturine
Screw (urlin) Spacing
How to Figure and Apply Screws 12 inch 18 inch 24 inch
v 50 270 160 135 '3
Gulf Coast Supply carries screws in 3 different lengths: 1 inch, 11/2 c 100 540 360 270
inch, and 2 r/2 inch. 1-inch screws will barely penetrate a lx4, but the o 200 1080 720 540
1'/2 inch are the best all-purpose size. 11/2- or 21/2-inch screws are 5 300 1620 1080 810 t
400 2160 1440 1080
necessary for attaching ridge caps. The table on the right can be c,
used to figure approximate quantities of screws for various urlin g 500 2700 1800 1350
g PP q P o 600 3240 2160 1620
spacings and sizes of roofs. For 2-foot spacing between rows of o 700 3780 2520 1890 t
screws, multiply the total linear feet of metal times 2.7 d 800 4320 2880 2160
Example: your order is 1250 feet of Gulf Rib roofing. 2 900 4860 3240 2430
fz
m 1000 5400 3600 2700
1250 x 2.7 = 3375 screws Z 1100 5940 3960 2970
Please confirm all estimates with your Gulf Coast representative when 1200 6480 4320 3240
you placed your order. TRgure 6 Gulf Rib panel screw . _
Codes allow re -roofing over shingles without the use of battens calculation chart
provided the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity.
Gulf Rib metal roofing can be separated from the moisture barrier by minimum, nominal 1 "x3" yellow
pine battens spaced on maximum 24"centers, or according to ASCE calculations where applicable. Since
direct contact between pressure treated lumber and metal roofing must be avoided in order to prevent
potential corrosion, Gulf Coast Supply sells only untreated battens.
CAUTION: Battens must be fastened to the roof deck with minimum #6 screws at 12" on -center, or two
minimum 8d common or pneumatic nails spaced 8" on -center, or one every 4" on -center (or by applicable
calculations according to ASCE 7-98). Battens must be installed to support the entire width and length
of ridge, eave, hip, valley, and gable -end trims.
— For solid decking, at least-15/32-inch-structural plywood supported -on rafters -at -a -maximum of 24" on- —
center is required.
If care is taken, metal roofing application can be aided by pre -drilling panels, allowing screws to go
quickly and accurately into the desired spacing. Pre -drilling will work provided that pilot holes are placed
accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured.
For panel lap details, see Figure 5 on page 4.
Gulf Coast Policies
Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales
department for details.
Sales tax All orders picked up at Gulf Coast Supply, and all orders delivered within the state of Florida, are subject to
state sales tax. Tax exemptions should be verified prior to delivery or customer pickup.
Warrantied products A 40 year warranty applies to most material* manufactured from painted coil stock, and a 25-year
warranty to Galvalume material. Ask for details.
Indemnity All prices and designs are subject to change without notice
Disclaimer While we have made every attempt at accuracy in this manual, we are not responsible for typographic,
printing, or technical errors.
Oil Canning —a repeating, wave -like appearance in the length of the panel —is a common and often unavoidable
phenomenon in metal panels like Gulf Rib roofing that have large, flat areas within the panel. It is therefore not a
defect, nor a cause for rejection. See p. 3 for details on how to avoid oil -canning.
Return policy All panel orders and special order (non -stock) trims are considered the property of the customer and non-
refundable once they are manufactured. Standard trim and accessories are refundable providing they are returned in a
clean, resalable condition. For details, go to www.gulfcoastsupply.com and click on "No Hassle Return Policy" at
bottom of page, or call Gulf Coast Supply to ask specific questions about returns.
M%7QX.7"7_
Gable Flashing
1.0 3 11-�
7-
=5" 3"
1
EF-1 style 7116"
Custom trim —specify a custom R
length fororb. �
Standard dimensions — a = 3"
b=3"
GR-1 style
Custom trim —specify a custom fi
length for a or b. b
Standard dimensions — a = 2 4s"
b =2V'
Figure 14 Sidewall flashing is applied when the side of the
roof butts up against an adjacent wall. The wall -side of the
flashing can either be covered over with siding or sealed
with caulk (order SW-1C). Butyl tape should be applied
where the "foot" of the flashing attaches to the roof.
N� \
View qf EF-1 able trim(fascia board removed
Figure 13 Gable flashing is used to trim the edge of the
roofing panel at the gable end of the roof. It should match
the eave drip that extends along the drip edge of the roof. If
the panel is allowed to hang over the gable end, eave drip
can be used instead. Butyl tape between the trim and
panel eliminates leaks.
Side -wall Flashing
caulk (Solar SeaF recommended)
3
.,'1 3/4
T
edge (order SW-1C)
(used if sidewall not
covered by siding)
Bulyl tape
SW-1 _
Custom trim —specify a custom
length for a or b.
J.
Standard dimensions — a = 3" 1L
�
b=3"
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852 (352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-6- - 11 -
End -wall Flashing
End -wall flashing is applied where the upward
slope of a roof meets a wall. The wall side of
the flashing can be covered with siding or
counter -flashing, and outside closures are
necessary to seal
caulk (Solar 3eaP between t h e
recommended)
caulk edge (order EW-1Cl flashing and the
3.,, (used if endwall not panel. Roof slope
covered by siding) s h o u l d b e
mentioned if foof
\3 z'exceeds 5/12
pitch.
Figure 11 As with the ridge cap, the ENDWALL
FLASHING above is sealed using outside closures.
EW-1 Stepped
Use EW-2 hemmed endwall when cornering endwalls with sidewall b Endwall EW-2 Hemmed
flashing, such as with dormers or chimneys. 4 b Endwall
For custom end -walls, specify roof pitch and dimensions "a" and "b". �a�l I ''\a a - 4t�2 ,
\'I b=3"
Transition Flashing
The TRANSITION FLASHING prevents
leakage at the point where two different roof
pitches meet. It must be sealed on the lower
side with outside closures, and can be sealed
underneath the upper panels with inside
closures. The similar GAMBREL
FLASHING is used where the lower pitch is
steeper than the upper.
TF-1 Transition Flashing
For custom transition flashing specify the pitches
of the two roof slopes and, if necessary, dimensions
"a" and "b„
Figure 12 The transition flashing
(above) and the GF-1 gambrel
flashing (right) provide a
continuous drainage where two
slopes meet. Both seal with
outside closures on the lower side.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-10-
Gulf Coast Gulf Rib® Roofing Panels
Fastening Schedule for Various Wind Speeds — minimum 2:12 roof pitch
Wind Speed Zone
130 MPH7
140 MPH
150 MPH
160 MPH
Roof
Fastener
Fastener Size
Attaching to
On Center
On Center
On Center
On Center
Zone
Type
Spacing
Spacing
Spacing
Spacing
Zone 1
Woodgrip
or
-1h
#9 15 x 1
min..15/32
-24" -
_ -- 24"
24"
24"
woodZac®
plywood
Type 1
Type 1
`Type 1
Type 1
Zone 2
Woodgrip
x 1'Fi
min.15/32
24"
24"
24"
24"
WoadZac®-15
Plywood
Type 1
Type 1
Type 1
Type 2
Zone 3
Woodgrip
or
-_ -
#9-15 x1�h
min. 15/32
•. -'24" ..
_ 24"
24"
: 24n
woodzec®
plywood'
Type 2
Type 2
Type 2
Type 2
Fastener pattern
Type 1
Type 2
Zone 2 a ��
Eave
..................................................................
----------------Ridge--------------
]...................................................................:...
Zone 1
K
Fastener pattern
Fastener patterns Type 1 and Type
2 are shown at left, row spacings are
shown in the table above, and roof
zones are displayed on left below.
Figure 7shows a simple illustration of
the patterns. Note that fastener pattern
Type 2 is required at top, bottom, and
end laps of each panel, as well as in
additional areas according to which
roof zone the fasteners fall in.
Each "zone" of the roof has its own
screw requirements. Dimension a is
defined as 10% of the minimum width
of the building, or 40% of the mean
height of the roof, whichever is
smaller; however, a cannot be less
than either 4% of the minimum width
of the building, or 3 feet.
Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, Cave
and on the overlap side of any panel laps.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
-7-
u
Eave drip with fascia and inside closure.
Figure8 Eave drip and fascia give a finished look along the drip
save of the house, as well as providing protection for the
materials they cover. The save drip should completely cover the
top edge of the fascia. Inside closures, which seal off the open
ribs of the panels, are optional.
Eave Drip
& Fascia
FHA Style
Eave drip
k—b�l
Eave drip a
Fascia
NbN
ED-3 Style 21'g"
Eave drip
R
For custom eave drip, specify the
amount of the eave that will be
covered (dimension "a"), and, for
steeper roofs, specify pitch . If
fascia is desired, be sure that the
dimension you order will be
hidden by the eave drip.
Summary of Stock Trims and Flashings
item special order information
Ridge caps (RC-2)
specify pitch if less than 3/12 or greater than 6/12. Also available in
larger widths. Closures recommended.
Eave drip (FHA, ED-3)
2 common styles. FHA style is pre -pitched for 3/12 to 6/12 roofs. For
appearance or ease of application, order by either specific pitch or as
gable trim (90°).
Gable flashings
Residential (EF-1), large (GR-2), and small (GR-1) rakes available. Use
butyl sealant between rake and panel.
Valleys (PV-1)
specify pitch if greater than 7/12. Seal with universal foam closure
material. Open -hemmed valleys (PV-2) aid water -tightness.
Sidewall (SW-1)
Use butyl sealant between sidewall flashing and panel.
Endwall (EW-1)
Specify pitch if greater than 5/12. Seal with outside closures.
Transition flashing
Specify pitches of both roofs. Seal lower slope using outside closures and,
if desired, inside closures on upper slope.
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852
G IfMst Supply &
Ridge Cap Ooo-
The Ridge Cap is used to seal the point at
which two upward slopes meet. This can
be both along the ridge of the roof as well
as a covering for a hip. Either woodgrip
or self -drilling lap TEK screws are
applied through the ribs of the metal.
Since debris, insects, and blowing
rain can find easy access under the ridge
cap, closures are required to either
completely or partially seal the opening.
Closures under ridge caps come in 3
types: solid, vented, and hip tape.
Solid closures ("Outside Closures") are
the same width as the panels. They lock together in a row placed directly
under the screws that attach the ridge cap, and form a solid, water -tight,
air -fight barrier.
Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water -
retardant, insect resistant barrier that allows hot air to escape from the
attic, and is superior to many more elaborate and expensive vent systems.
Any length may be ordered.
-Hip closure tape (Peel and"Seal®) is a sticky, adhesive=backed metallic tape
that seals the hip roof. It is 6 inches wide and comes in 33t/2 foot rolls.
Because it must be conformed to the rise and fall of the panel ridges,
approximately 10% extra may be needed beyond the length of the hip
being covered.
Out]
cloy
ent®
sa-Vento
screw required
RC-2 Standard 12-inch Ridge Caps
are strong, economical and adequate for most of your roofing needs
C
RC-1 style 12-inch Ridge Caps
are also available in custom widths
Figure 10 Pipe Boots provide a
water -tight seal around roof
vents and come in a variety of
sizes. They seal with caulk and
conform to the shape of the
panel ribs.
a�
RC-2 style over -sized ridge caps
are available with 18-inch coverage, or as a custom trim
item in total widths (2 times "a") of 14-, 16-, 18-, 20-,
22-, and 24-inch
(352) 498-0778 • Toll Free (888) 393-0335 • FAX (352) 498-7852