HomeMy WebLinkAboutSUBMITTED PAPERSn
ALL APPLICABLE INFIO M ST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: SCANNED Permit Number:
BY
rsT= ' St. Lucie County
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
t)4�a -crn
Commercial Residential V
PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line 1� ® C0
PROPOSED IMPROVEMENT LOCATION:
Address: tO_0-5 SI Ocean � L Low` eyzi SeAstin 3c tl • R_ 3,1957
Legal Description: 0V4
:I �q
Property TaxID`#-.,
Site Plan Name: Block No. 10
Project Name:
Setbacks Front Back: Right Side: LeftSide:
DETAILED DESCRIPTION OF WORK:
.P,MMdv{. Sh�rv�l`e—v, ,Gny, ��N S-t/cr2laup Yri-GFes( /im®�
G no S' Lf fla
I CONSTRUCTION INFORMATION:
MuwuvuaI W UTA w uc ownucu uuum unn paJuuL—uie�adn dpply.
11HVAC Gas Tank E]GasPip ing _Shutters ❑Windows/Doors
Electric 0 Plumbing
Sprinklers E Generator D oof
Total Sq. Ft of Construction: i% S Ft. of First Floor:
Cost of Construction: $ S u Utilities: Sewer ElSeptic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name &&
niName:
z_CCM,4
GlS CeD
Address: is qd, k04q.(,
Company:
ink
iv�5 �•
City: 1:; 7LJi1'+P-1 Stater
Zip Code: 1 6 `115 Fax:
Phone No.
Address:
n�UiK)i
YQ k
10C3 J
City: _J
Zip Code:
Phone No.
_
m CI N State:_FL
3' 7 / Fax:
7*7 2k0-3145
E-Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
E-Mail:
&J OIG / 1 ,CO&I
State or County License:
CCC /3T ?i9&
If value of construction is 52500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE COMPANY: — Not Applicable
Name:
Address:
Address:
City: State:
Zip: Phone:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
BONDING COMPANY: _Not Applicable
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approw4plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencine work or recordine vour Notice of Commencement.
Signature oFOy6ner/ Agent/ Lessee
STATE OF*LORIDA STATE OF FLORID/� + rJ `
COUNTY OF `�' (Lt i,� COUNTY OF 1�c L t
The f oing instrument was acknowledged before me
this day of 20 14 by
person
(Signature of Notary
Revised 07/15/2014
Tho#prgoing instrument was acknowledged before me
thi day of 20 1A by
CAS
(Name of person acknowledgm )
(Signature of Notary Pu ic- State of Florida )
Personally p7T7fXa•. OR Pryd ce dentification
Type of Idye :fta inu_ P d j
d *_Ao Jrcu _
Sols
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
JOSEPH E. SMITH, CLERK OF TRc_r.IRCUIT COURT - SAINT LUCIE COUNTY
FILE # 4018215 OR BOOK 369.' -AGE 2156, Recorded 12/02/2014 at 12 ,PM
NOTICE OF COMMENCEMENT
The undersigned hereby given notice that improvement will be made to cenain real property, and in accordance with Chapter 713,
Florida statutes the following information is provided in the Notice of commencement.
I. DESCRIPTION O.FI �P1�ROI�PER/�J1.egal �I7,�scription and sheet address) TAX FOLIO N[ID1BEA. I %O/
SUBDIVISION illoT04Tr rirw Y moire v ern In .,..... ........
2. GENERAL DESCRIPTION OF
o. nmress — FP!jy % • 1 FlULOW"W1 f /J 1 fF r f c. interest in property O 1_
d. Name and address of fee simple titleholder (if other than owner)
CON�TRAC'OR'S.41M DDREccnNn'HONE NOp1BER: Sf1h5 f✓�z O NJI O1G
5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT:
6. LENDER'S NAME, ADDRESS AND PHONE NUMBER:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (1)(a) 7.. Florida Smrutes:
NAME, ADDRESS AND PHONE NUMBER:
S.In addition m himself or herself, Owner designates the following to receive a copy of (be Lienor s Notice as provided in Section
713 010(b). Florida Statutes:
NAME, ADDRESS AND PHONE NUMBER:
9. Expiration data of notice ofcemmencement (the expiration date is 1 year from the date of mantling unless a different date is
Print Name and Provide Signatory's TIDdOMve
OHlcer/Direems/Partnerimmager
State of Florida
County of /
The forego. ins ment was pc�vawledgM before me this day of �'e L . 2p (�/
(Nano of erson) (Type of authority...e.g. Owner, ofaceo mustee, attorney in fact)
For
(Name ofperty, on behalf ofwhom instrument was executed) Personally Known_ orproduced the following type oflD:
�l I dlYS9 RAYPfON
\}1 n 001RY EWlkODla olimrMr
�i wNamc of otary P blic) f9gnaturd bf Not blic My Comm. EIWIe1 Jul 10. 2010
commission 0 If I Dims
Under Penalties of perjury, I declare that I have read the finegoing and that the facts in i
belief (section 92.525. Florida Smtutu).
.y'�Si ' (s) of OO WS) or Owner(s)• Authorized OBicer/Diteetoo(Pariner/Manager who signed above:
... BY
STATE OF FLORIDA
ST. LUCIE COUNTY
THIS IS TO CERTIFY THAT THIS IS A
TRUE AND CORRECT COPY OF THE
ORIGINAL. ,!
Date:
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
E-mail pwelchinc(a)aol.com
November 26, 2014
Re: Kilmer Re -Roof
10725 S. Ocean Drive Lot 444
Jensen Beach, FL 34957
SCOPE OF WORK-
Remove existing roofing and install new 5-V Crimp Metal Roof (Sunlast Metals FL # 10490.6)
at above referenced residence address over new underlayment and existing plywood sheathing.
DESIGN CRITERIA:
FBC 2010
ASCE7-10
PROJECT DATA:
BUILDING HIEGHT=10'-0"
A= 3'
MEAN ROOF HIEGHT = <20'
ROOF ANGLE = 4:12
SHAPE = PITCHED GABLE
ADJUSTMENT FACTOR =1.00
1MPROTANCE FACTOR =1.00
WIND VELOCITY V utt =165 MPH
WIND VELOCITY V asd =128 MPH
EXPOSURE = D
ENCLOSURE CLASS =ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0,18
APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (ysfl•
ZONE 1 (Field) = 41.6
ZONE 2 (Perimeter/ Ridge) = -70.2
ZONE 3 (Corners) = -103.2
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
November 26, 2014
10725 S. Ocean Drive Lot 444 Jensen Beach, FL 34957 100 3
ATTACHMENT REOUIREMENTS:
Metal roofing to be attached with Hex -Head wood screws with Weather Seal Washers (WSW)
#10 x 3/16" minimum penetration through deck spacing as follows:
ZONE 1 (Field): ROW SPACING = 16" O.C., FASTENER SPACING =12" O.C.
ZONE 2 (Perimeter/ Ridge): ROW SPACING = 8" O.C., FASTENER SPACING = 12" O.C.
ZONE 3 (Corners): ROW SPACING =8" O.C., FASTENER SPACING =12" O.C.
Method # 1 ACCEPTABLE FOR ZONE # 1
Method #2 ACCEPTABLE FOR ZONES #2 & #3
Method #1 Design uplift Pressure: -50.5 psf
Method #2 Design uplift Pressure: - 106.75 psf
Note: All roof slopes with slope under three units vertical in 12 units horizontal shall have
applied lap sealant. Lap sealants shall be applied in accordance with the approved
manufacturer's installation instructions. Metal roofs shall not be installed for roof slopes under
one-half unit vertical in 12 units horizontal.
UNDERLAYMENT•
Underlayment shall be in accordance with manufacturer's guidelines and FBC 1507.4.5.
DECK INSTALLATION:
Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
All work to be m compliance with product approval (FL # 10490.6), manufacturer's
specifications, and the Florida Building Code 2010.
Submitted by:
PAUL LCH INC.
Paul Welch, P.E.
Reg. No 29945
PW:pj
10725 S. Ocean Drive Lot 444 Jensen Beacb, FL 34957 2 of 3
6 rmr
ROOF ZONV PLAN
A=3'
Ql , QZ , 3Q= ZONEDESIGNATION (TYPICAL)
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
November 26, 2014
10725 S. Ocean Drive Lot 444 Jensen Beach, FL 34957 3 of 3
Florida Building Code Online
Page 1 of 1
` I I - !
rofessi Regulat•
to e✓ee�=r:
S£G4�iARY,rv,:p
'm I Hot Top¢
_nir.,:ra-3r
q -,
". 9HP ttOYE{,Jv�cdi'�EVR" DESK �tI':f554M: ,C?Yli'.1,�6:ii,
rc r rla Refine Search
Code Version
2010
FL#
10490.6
Application Type
ALL
Product
anufacturer
ALL
Category
ALL
Subrate
ory
ALL
Appfication Status
ALL
Compliance
Method
ALL
Quality Assurance Entity
ALL
Quality Alssurdnce
Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved
for use outside HVHZ
ALL
Impact Resistant
ALL
Design P{
asure
ALL
Other
ALL
Search 2eea1M - A.nfir. nwe
PL#
Type
Manufulurer
Validated By
Status
FL7049D-
Revision
Suniast Metal
F'L#: FL10490.6
Steven M.
Urich, PE
Approved
33
History
Model: 6 - "S-V Crimp"
(717) 932-8500
Description: Roof Panel - 26 Gauge
Steel, 24" Width, Attached to
Plywood Deck w/Optional Rigid I
sulation
Category: Roofing
i
Subcategory: Metal Roofing
ho://www.floriclabuilding_org(pr/pr app lstasm 11/26/2014
m
CBUCK
Spealcwy StrU="CN
Evaluation Report
"5v Crimp"
Metal Roo Assembly
Manu cturer:
Sunlast Metal, Inc.
2120 SW Pbma Drive
Palm City, FL 34990
(772) 2 ,3-4055
Florida Prod
#FL104
Florida Buildir
Per Ruli
Method:
Category:
Sub - Category:
Product:
Material:
Panel Thickness:
Panel Width:
Support:
James L. BucknE
Florida Professional
Florida Evaluatio
Project Manager:
Report No.12-1
Date: 4 /
Evaluation Report
1399 N. IGllian Drive,
Phone: (S63)491-9927 Farc
CBUCK Inc Certificate of Authorization #8064
ct Approval
)0.6 R3
g Code 2010
9N-3
1-D
Roofing
Metal Roofing
"5V Crimp" Roof Panel
Steel
26 gauge
24"
Wood Deck
d by:
', P.E., S.E.C.B.
Engineer # 31242
i ANE ID: 1916
Nana Galloway
16 / 12
Its:
Pages 1— 7
Inc.
( paZ
�J L Buckner, P.E., SECB
Florida .E. # 1242
-�i1/17-
Im Beach, Florida 33403
Website: www.cbuddncnet
[BUCK
SPecl-a'U Stn-octutaf
Manufacturer:
Product Name:
Product Category:
Sunlast Metal, Inc.
"SV Crimp"
Roofing
Product Sub -Category Metal Roofing
Compliance Method:
Product/System
Description:
Product Assembly as
Evaluated:
Support:
Slope:
Performance:
State Product Approval Rule
"SV Crimp"
26 gauge Steel roof panel me
Refer to Page 4 of this re;
standards:
1. Roof Panel
2. Fasteners
3. Underlayment
Type:
Wood Deck
(Design of support and its at
this evaluation.)
Description:
• 15/32 (min.) or greater p
• or Wood plank (min. spe
Minimum slope shall be in ac
Section 1507.4.2 and applical
Wind Uplift Resistance:
• Design Uplift Pressure:
(Refer to "Table A" attachr
FL #: FL 10490.E-R3
Date: 4 / 6 / 12
Report No.: 12-139-SV-S6W-ER
Page 2 of 7
CBUCK Inc. Certificate ofAuthorization #8064
(1) (d)
nically attached to Plywood Deck with screws.
for product assembly components/materials &
to support framing is outside the scope of
is gravity of 0.42)
dance with manufacturer's recommendations, FBC
code sections.
METHOD 1: - 50.5 PSF
details herein) METHOD 2:-106.75 PSF
FL #: FL 10490.6-R3
Date: 4 / 6 / 12
MUCK Encgineerinq Page Report No.: 3 of 7 511-55w-ER
spea=cwu Stn—K-- fe1 eprwm�p„rla CBUCK Inc. Certlficote ofAuthodkatIm #8064
Performance Standards: The product described hereip has demonstrated compliance with:
• UL580-06 — Test for Uplift Resistance of Roof Assemblies
• U L 1897-04 — Uplift test for roof covering systems
• TAS 125-03 —Standard lequirements for Metal Roofing Systems
Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product
assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04
adopted by the Florida Build I ng Code 2010.
Code Compliance: The product described herein has demonstrated compliance with Florida Building
Code 2010, Section 1504.3.2
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code as related to the scope section to Florida Product
Approval Rule 9N-3.001.
Limitations and • Scope of "Limitations and (Conditions of Use" for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance
with Rule 9N-3.005. P�r Rule 9N-3.004, the Florida Building Commission is
the authority to approv , products under "Optional Statewide Approval'.
Quality Assurance:
• _U_ption Tor application out
Rule 9N-3.005(1)(e) allo
by the local authorities
methods and materials
product as evaluated ii
Commission is outside
responsibility of others.
• Design of support system i
• Fire Classification is outs
included in this evaluation
• This evaluation report doi
High Velocity Hurricane
The manufacturer has i
accordance with the F
manufacturing under a qi
assurance entity through
1824).
is engineering analysis for "project specific approval
laving jurisdiction in accordance with the alternate
authorized in the Code". Any modification of the
this report and approved by the Florida Building
the scope of this evaluation and will be the
outside the scope of this report.
le the scope of Rule 9N-3, and is therefore not
not evaluate the use of this product for use in the
ne code section. (Dade & Broward Counties)
nstrated compliance of roof panel products in
a Building Code and Rule 9N-3.0005 (3) for
assurance program audited by an approved quality
tone Certifications, Inc. (FBC Organization #: QUA
FL #: FL 10490.E-R3
Date: 4 / 6 / 12
tnq Report NO.: 2-139-5V-s6w-ea
CBUCK EngIneer4
Page 4 of 7
SPSCk y 5tf1ici-UTCed CBUCK Inc. Certlficare ofAuthorizatlon #8064
Components/Materials
(by Manufacturer):
Roof Panel:
Material:
Thickness:
Panel Width:
Rib Height:
Yield Strength:
Corrosion Resistance:
Fastener:
Type:
Size :
Corrosion Resistance:
Standard:
"SV Crimp"
Steel
26gauge (min.)
24" (max.) Coverage
1/2„
40 ksi min.
In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90galvanized steel
Hex -Head Wood Screw with WSW
#10 x 1-1/2" "
Per FBC Section 1506.6 and 1507.4.4
Per ANSI/ASME 818.6.4
Underiayment:
Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5
Insulation (Optional):
Type:
Thickness:
Properties:
Density:
Or Compressive Strength:
Rigid Insulation Board
3" (max.)
I
12.25 pcf (lbs/ft3) min.
120 psi min.
Insulation shall comply with FBC Section 1508. When insulation Is incorporated,
fastener length shall conformIto penetrate thru bottom of support a minimum of
3/16".
FL #: FL 10490.6-113
Date: 4/6/12
CBUCK&n6inPiemring Report No.: 12-139-sV-56w-ER
Page 5 of 7
I
EveCidlFy Stnic"c5l Ef qrwiPrilimi CBUCX Inc. CerthcareofAuthorizatimUso54
Installation:
Installation Method:
(Referto drawings on Pages
■ Row spacing: Referto'
(along the length of th
• Fastener spacing: Nom
(along the row, across
■ Rib Interlock: Lapped
of this report.)
ble "A"
panel)
al pattern of 12" o.c.
ie panel profile & at the top of corrugation peaks)
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
Instructions and any site. pecific design.
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
- 50.5 PSF
-106.75 PSF
Row Spacing:
16"
8"
Fastener Spacing:
12"
12"
Install the "SV Crimp" roof
method listed in this repo
Installation method describ
evaluation report. Refer
supplemental guide forattac
mel assembly in compliance with the installation
and applicable code sections of FBC 2010. The
herein is in accordance with the scope of this
D manufacturer's installation Instructions as a
Referenced Data: 1. TAS 125-03 Uplift Test
Hurricane Test Laboratory, LLC (FBC Organization #TST ID:1527)
Report#, 0412-1017-05,1Report Date: 02/22/06
2. Quality Assurance
By Keystone Certifications, Inc. (QUA ID: 1824)
Sunlast Metal & Solar, Inc. Licensee # 385
3. Engineering Analysis
By CBUCK Engineering
4. Equivalency of Test Standard Certification
By James L. Buckner, P.E.I@ CBUCK Engineering
(FBC Organization # ANE 1916)
S. Certification of Independence
By James L. Buckner, P.E.!@ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 10490.6-113
Date: 4 / 6 / 12
Repo
CBUC ��// I� Engineering rf veering Page rt No.: 6 of 7 sys5w-ee
speeidlrLf Stn�eFurdl �9 hRQ CBMC Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck
Profile Drawings
24" MaDdmum Net
"5V Crimp" Panel
Typical Panel Profile View
Nominal 12" o.a I , Nominal 17 o.c.
Fastener Spacing
Across Panel Width
#10 Hex -Head Screw with WSW
Spaced 12" across the Panel
I
Assembly Profile View
Typical Fastening Pattern Across Row
CSUCK
E:nc;)InL=L=rinq
FL #: FL 10490.E-R3
Date: 4/6/12
Report No.: 12-139-sV-ww-ER
Page 7 of 7
Sp ddl i StfLJCFLxc!d engu'm2onr1Q CBUCK Inc. Certificate ofAatirorizatlon#2064
Installation Method
Sunlast Metal, Inc.
"5V Crimp" (24 Gauge) Roof Panel Attached to Wood Deck
Panel Fastenem-
#10 Hex Head
-1SW or greateOlywood, or Insulation T mafturn
- Wwd plank
Typical Assembly isometric View
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
- 5015 PSF
-106.75 PSF
Row Spacing:
16"
8"
Fastener Spacing:
12"