HomeMy WebLinkAboutSUBMITTED PAPERS�X ALI.APPLICABLE INFO MUST BE COMPLLv_t FOR APPLICATION TO BE ACCEPTED Date: November 19, 2014 SCANNED Permit Number: 1 1 —BY d a5 y St. Lucie County • Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Roof III Address: 112 NE Naranja Ave Legal Description: RIVER PARK -UNIT 4 BLK 40 LOT 24 (MAP 34/28N) (OR 3625-2798) Property Tax ID #: 3419-530-0246-000-9 Site Plan Name: Project Name: Setbacks Front Back: DETAILED DESCRIPTION OF WORK: Right Side: Left Side: Lot No. 24 Block No. 40 Remove old shingle roof, renail plywood to meet current code, install underlayment (30# Felt), install new shingles CONSTRUCTION INFORMATION: Aaamonal work to e e orme under be t—checkispermit a apply: �HVAC ❑Gas Piping Shutters ❑Windows/Doors Electric Plumbing Sprinklers E_Generator W1 Roof Total Sq. Ft of Construction: S Ft. of First Floor: Cost of Construction: $ ;-2 Utilities. Septic Building Height: OWNER/LESSEE: Robert P Dudley CONTRACTOR: H.O.B. Name Robert P Dudley Name: Address:112 NE Naranja Ave Company: City: Port Saint Lucie State: FL Zip Code: 34983 Fax: Phone No. 772-201-7252 Address: City: State: FL Zip Code: Fax: Phone No. E-Mail: bob@prontoplans.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail: State or County License: it value of construction is 5;zwo or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTIO N LAW INFORMAT(QN: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: x Not Applicable Name: Address: Address: City: State: Zip: Phone: City: State: Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before Lessee STATE OF FLORIDA COUNTY OF Sfi . L oc �8 The forgoing instr ent was acknowledged before me this V*%day of W 6%J 20 14 b (Name of person acknowledging') (Signature of Notary Public -State Personally Known OR Prc Type of Identification ProduW.Oo- Commission No. Revised 07/15/20 Signature of Contractor/License Holder STATE OF FLORIDA COUNTY OF The forgoing instrument was acknowledged before me this _ day of 20_1A by (Name of person acknowledging) (Signature of Notary Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Produced Notary PUD". yes Dec A'. MY Como& # EE %` sn Commission No. commiss^*NaGsnatNotary Ps (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Planning & Development Services Department Building & Code Regulations 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence for your use and occupancy. You may also build or improve a commercial building at a cost not exceeding $75,000.00 as long as it is for your own use or occupancy. You may not build or improve said structures for the purposes of selling or leasing that building. If you sell or lease a building you have built or improved within one year after construction is complete, then a presumption is created that it was built or improved for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a lice contractor who is not licensed to perform the work being done. Your construction must comply with all le laws, ordinances, building codes, and zoning regulations. Initia I understand that the building official and inspectors are not there to design or give advice on hryc(%p t the minimum code. Initial. I understand that as an owner -builder that any contract disputes with sub -contractors and I must be hanillpo in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and li r the cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and rela[ ical cost, which could include loss of wages during recovery from their injury. Initial To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Department to the Florida State Department of Professional Regulation. Signed and acknowledged on this_ _day of of20 Ow uilder Signa[ur STATE OF FLORIDA COUNTY OF 5)t-. L Q C,\. .1 The �'oregoing ins ment was acknowledged before me this M day of �I dJ 20�, b o %C Jr O d \%t who is personally known to me, or who has produced t L. L as identification. Type or Print Name of Notar Commission Number E. g 5� DEANNA 131W45 :, ,`�: Notar Pu is - State of BfaGlty ' -ea �s : ; ; My Co m: ion # Dec t6,61 e: Commission a EE 868769 Signature of Not ry Title: Notary Public °um Bonded Throogh Nalwal No,ry nn, SLCPDSD Revised 05/15/2014�'�` ' M®' FILE ®Pll DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Certainteed Corporation (PA) 1400 Union Meeting Road Blue Bell, PA 19422 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Landmark TL LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 06-0914.04 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-0824.05 Expiration Date: 11/16/16 Approval Date: 05/24/12 Page 1 of 4 .1 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials Deck Tyne: SCOPE Laminate Wood This revises and renews roofing system using Certainteed Landmark TLAsphalt Shingles, manufactured by CertainTeed Corporation as described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Certainteed Landmark TL 13%" x 40" TAS 110 A heavy weight, dimensional asphalt shingle. Manufacturi ng Locations#1, 2 MANUFACTURING LOCATION 1. Freemont, CA. 2. Oxford, NC EVIDENCE SUBMITTED Test Agency Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. PRI Construction Materials Technologies LIMITATIONS Test Identifier Test Name/Revort Date TAS 107 01NK48206 12/18/01 Letter R684 01/28/02 TAS 107 09CA24052 10/17/09 ASTM D 3462 11NK08333 04/15/12 TAS 100 CTC-003-02-01 12/14/01 TAS 100 CTC-085-02-01 07/06/11 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. MIAMI•DADE COUNTY ,...IM, NOA No.: 11-0824.05 Expiration Date: 11/16/16 Approval Date: 05/24/12 Page 2 of 4 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail W, attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-0824.05 Expiration Date: 11/16/16 Approval Date: 05/24/12 Page 3 of 4 C DETAIL A Eaves Edge DETAIL B CertainTeed Landmark TL 13 1/4" x 40" LAMNATED SHINGLE All dimensions are in inches. 13 1/2 13 13 1/2 1 1 13 1/4 1/8 =Exposure END OF THIS ACCEPTANCE NOA No.: 11-0824.05 Expiration Date: 11/16/16 Approval Date: 05/24/12 Page 4 of 4 OFFICEUSEONLY: DATE FILED: 3 2 1 �7,0/ REVISION FEE: 15 .O Z PERMIT # A//) — U 2— y RECEIPT # I o r.!f;).1 PLANNING & DEVELOPMENT SERVICES (9 BUILDING & CODE REGULATION DIVISION sf, ��ti 2300 VIERGINIA AVENUE FORT PIERCE, FL 34982-5652®~ (772) 462-1553 FAX (772) 462-1578 cm O APPLICATION FOR BUILDING PERMIT REVISIONS �y PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: //Z Ah "4*IU .1 /} At(e -pi Sr 4vc)-- Fy 3-'1983 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: -PUS I4LL ale I1jL-- ROOF -6 v 3. 4. 5. STATE of FL REGJCERT. #: BlWi41Dfi IQ/:\uI_or, ST. LUCIE COUNTY CERT. #. QUALIFIERS NAME: 1 ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIIVIE): FAX: r SAI i/: 11 I miI I NAME: eRo )J e r+ ADDRESS: j/2, ` li CITY: 97' S T- PHONE: (77; 1 Z ARCHITECT/ENGINEER INFORMATION: NAME: _ ADDRESS: _ CITY: _ PHONE (DAYTIME): STATE: fL ZIP: 3 ld/98S FAX: /688) s(09 - /0 58 STATE: ZIP: FAX: ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE f CBUCK Engineering Specics"'W Structural Erlgineerinq Evaluation Report "5-V Crimp" Metal Roof Assembly CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 for Florida Product Approval # FL 17022.1 Florida Building Code 2010 Per Rule 61G20-3 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: "5-V Crimp" Roof Panel Material: Steel Panel Thickness: 26 gauge Panel Width: 24" Support: Wood Deck Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer# 31242 Florida Evaluation ANE ID: 1916 Project Manager: Youry Demosthenes Report No. 14-115-5V-S6W-ER Date: 4 / 28 / 14 Contents: Evaluation Report Pages 1-7 CBUCK, Inc. 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net -14 FL fi: FL 17022.1 Date: 4 / 28 / 14 g PagertNo.:24of�5-SV-S6W-ER CBUCK Engineerin Spectcalty Structural Encjlneerinq CBUCK, Inc. Certifimte of Authorization #8064 Manufacturer: Extreme Metal Fabricators, I LC. Product Name: "S-V Crimp" Product Category: Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "54 Crimp" Roof Panel Description: 26 gauge steel roof panel mechanically attached to Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation Board (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Slope: Description: • 15/32" or greater plywood, • or Wood plank (min. specific gravity of 0.42) Minimum slope shall be in accordance with manufacturer's recommendations, FBC Section 1507.4.2 and applicable code sections. Performance: Wind Uplift Resistance: • Design Uplift Pressure (ASD): - 86 PSF (Refer to "Table A" attachment details herein) s:. FL FL17022.1 Date: 4 / 28 / 14 g Page Report No.: 3 of 75-SV-56W-ER CBUCK Engineerin Specialty Structural Encalneerinq CBUCK, Inc. Certificate of Authorization #8064 Performance The product described herein has demonstrated compliance with: Standards: • UL580-06 — Test for Uplift Resistance of Roof Assemblies • U L 1897-04 — Uplift test for roof covering systems Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 2010, Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • _Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Ootion for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certificat&AM Am Fitt FBC Organization I D# QUA 1824). COPY FL #: FL 17022.1 Date: 4 / 28 / 14 C®UCK Engineserinq Page Report No.: 4 of 75-SV-56W-ER Spxica ty StvuC_ture3l Engineering CBUCK, Inc. [ertijicote of Authorization N8064 Components/Materials Roof Panel: 5-V Crimp (by Manufacturer): Material: Steel Thickness: 26 gauge (min.) Panel Widths: 24" (max.) Coverage Rib Height: 5/8" Yield Strength: 40 ksi min. Corrosion Resistance: Per FBC Section 1507.4.3 Fastener: Type: Hex -Head Wood Screw with WSW Size : #9 x 1-1/2" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Underlayment: Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5 Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength Rigid Insulation Board 3" (max.) 2.25 pcf (lbs/ft3) min. 20 psi min. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". P r5c. r FL#: FL17022.1 Date: 4 / 28 / 14 C14-11 SUCK Engineering Page Report No•: 5 of 75-5V-S6W-ER Specidirw Structurc9l Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to'TABLE A" below and drawings on Pages 6-7 of this evaluation report.) • Fastener Spacing: Refer to'TABLE A"Below (attached to the tops of the V's for a total of 3 screws across the width of the panel.) • Row Spacing: Refer to "TABLE A" Below (along the length of the panel) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. Of 9=0 Design Pressure (ASD): - 86 PSF Fastener Spacing: 12" o.c. Row Spacing: 16" o.c. Install the "5-V Crimp" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 2010. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturers installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-06 & UL 1897-04 By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.01-450-18, Date: 05 / 02 /14 2. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QFit) Inv AOh Extreme Metal Fabricators, Inc. Licensee #974 3. Certification of Independence 0 By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # AN 1916) FL #: FL 27022.1 Date: 4 / 28 / 14 Page Report No.: 6 of 75-SV-56W-ER CBUCK Engineering SPeOdlty StruCFurcsi Englneerinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. "5-V Crimp" (26 gauge steel) Roof Panel attached to Wood Deck i 518 " F Drawings 24" Maximum Net Panel Profile Nominal 12" o.c. I Nominal 12" o.c. Fastener Spacing Across Panel Width #9 Hex -Head Screw with WSW Spaced 12" across the Panel Typical Assembly Profile View (Typical Fastening Pattern Across Width - Interior) FL #: FL 17022.1 Date: 4 / 28 / 14 CBUCK Engineering Pagert No.: 7 of;S-SV-56W-ER Sppclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. "S-V Crimp" (26 gauge Steel) Roof Panel attached to Wood Deck -15/32" or greater Plywood, or Rigid Insulation - Wood plank Thickness: 3" Maximum Typical Roof Assembly Isometric View TABLE "A" Design Pressure (ASD): - 86 PSF Fastener Spacing: 12" o.c. Row Spacing: 16" o.c.