Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSAWL All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Noll, �'�`U/%L� Permit Number: SCANNED BY St. Lucie County Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Port Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: ress. �� I • o I .k ' w; nd�TY--, � lT� W — Legal Description: Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: kin 11 Zp O / Additional wor to be performed under this permit—c ec all that apply: _Mechanical _Gas Tank _Gas Piping _Shutters _W,indows/Doors Electric _ Plumbing _ Sprinklers _ Generator Roof 7 lT agtsoim•onc structiam�no Sq. Ft. of First Floor: cr. - sL CsruCtio •$OtJ Utilities: _Sewer _Septic Building Height: Name / Name: Address: i // N Ccj., '141 Company: City: State�1 Address: City: State:_ Zip Coder Fax: Phone No. / 2 3- /yi�� Zip Code: Fax: E-Mail: Phone Fill in fee simple Title Holder on next page (if different E- ate or County License: from the Owner listed above) If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. rla rzr� 3 ( r'- a,L�,�1 n t �t��N� .ItI. �$kg a4F.)l��i'= "" 1 1�§fin, :'.3,_ f«..d+,_a.n iv- ^ • � _. "� ry s '. - -ar`T"ic:,•. _r-c y�11 ^' t t � � deg"s '`, }ua' �.'" � '•�r ? Uv*a��,,^,m x_• '�.,i.. v.u..�. ......,�.... Gg�''�"::.v-...ot�,sM ..... MORTGAGE • MPANY: Not Applicable _vL .,.�.a-._ .�' • •• • ••Address: Zip: Phone: BONDING COMPANY: —Not Applicable Address • • • • • OWNER/ CONTRACTOR AFFIDVIT: Application is herebypade to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the iobsite before the tirst inspection It you intend inancing, consult with lender or an attorney before commencing wgrk or rer6ording your Not '.' mencement. nature o er m/ Lessee Q o Signature of Contractor/License Holder STATE OFF ORIDA zA E N STATE OF FLORIDA COUNTY OF se 9m 9 m COUNTY OF N� The forgoing instrument Was acknowledged bef thi%2.i��day of �%! U .20& by "!o � The forgoing instrument was acknowle ed before me this_ day of 20_ by a 1-ail PLFDNXo (Name of person acknowledging) �j m'L1G�/!Al` (Name of person ackno edging ) �/Y•s (Signature Votary Public- State f Florida N Notary Public -State of Florida ) y Personally Known duced Identifi ition wn OR Produced Identification Typeof Identification Produce /Persony fication Produced n�n�r//o/�iComm�n � No`� (Seal) o. (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 7/2014 Planning & Development Services Department Building & Code Regulations 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence for your use and occupancy. You may also build or improve a commercial building at a cost not exceeding $75,000.00 as long as it is for your own use or occupancy. You may not build or improve said structures for the purposes of selling or leasing that building. If you sell or lease a building you have built or improved within one year after construction is complete, then a presumption is created that it was built or improved for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a lic sed contractor who is not licensed to perform the work being done. Your construction must comply with all I laws, ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on ho et the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must be dled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initia i I understand that if I compensate any person or company for work performed they are require o be licensed in this jurisdiction. If for some reason they do not possess a license, I maybe responsible and It f e cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my construction oject- they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and relat ical cost, which could include loss of wages during recovery from their injury. Initia To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported the Building and Department to t Florida St tepepartment of Professional Regulation. S' ned and now his ZoningDepartment of of 20 STATE OF FLORI COUNTY OF , j The foregoing instrument was a_knowledged before me thi��day of �%/ (/ ' , 20 / by who is personally known to me, or who has pro ced as identification. Signature ofNo y Type o Print Name ofNotazy (Seal) T;rle•Nntary Pu lic Com ission Number SLCPDSD Revised 05/15/2014 -,'I?" AUDREY9.HUMPHREY _.; .r WOOMMISSIOWEE061159 .. rg EXPIRES March 6, 2015 `�%rr.,%`P Bonded TNuNofaq Public Uaierwdters Property Appraiser - St.Lucie ^---nty, FL Page 1 of 1 PROPERTY RECORD CARD Luis Martinez Record:1 of «Pmv Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ,�1,UCIECo Site Address: 4911 Southwind Tri ParceIID: 1418-244-0005-000-1 �?< Sec/Town/Range: 18:34S:40E AG� Account#: 8006 Map to: 14/18N Use Type: SF Res Zoning: AR-1 City/Cnty: �, Saint Lucie County �. '� Ownorship and Mailing Legal Description Owner. Luis Martinez Cathy Martinez 18 34 40 NE 114 OF SE 1/4 OF SE 114 OF NW 1/4-LESS E 30 FT - Address: PO Box 690024 (2.32 AC) (OR 1445-218: 1426-466) Vero Beach FL 32967 Sates Information Assessment 2014 Total Land and Building Date Price Code Deed Book/Page 2014 TRIM: 214300 Land Value: 59700 Acres: 2.32 10/5/2001 8500 00 WD 1445 / 0218 Assessed: 200666 Building Value: 154600 8/7/1998 100 04 WD 1166 / 1342 Ag.Credit: 0 Finished Area: 2532 SgFt 8/8/1997 100 01 QC 1094 / 1830 Exempt: 50000 10/1/1974 6000 00 CV 0234 / 2101 Taxable: 150666 Taxes: 3172.67 BUILDING INFORMATION 7771 Exterior Features wA View: - RoofCover: SD - Dim Shingle RoofStmct: GA -Gable ExtType: HC-HC YearBit: 2002 Frame: - Grade: C-C EffYrBIt: 2002 PdmeWall: LG - Logs StoryHght: 0020 - 2 Story No.Units: 1 SecWall: LG - Logs Interior Features BedRooms: 4 Electric: MX-MAXIMUM PrnlntWall: DW-Drywall FullBath: 2 HeatType: FHA - FrcdHotAlr AvgHt/FI: 1/2Bath: 1 HeatFuel: ELEC- Electric Prm.Flors: HW- Hardwood %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cord. YrBlt. No. Use Type Type Measure ENC2 - POOL ENC-AVG Y 1 1064 AV AV 2010 1 0100SF Res 125 -Acres 2.32 SWAV - RES POOL AVG Y 1 512 AV AV 2010 PA02 - POOL DK-GOOD Y 1 552 AV AV 2010 Depth THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=141824400050001 11/24/2014 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 4027035 OR T300"-•7003 PAGE 2249, Recorded 12/31/2014 at 09:57 AM NOTICE OF COMMENCEMENT Permit No. lei I1 ' n-3l U Tatt Fano No. State of Florida County of St. Lude The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following infannadon Is provided in this Nam of Commencement. improvement: Name Address mceresr in ProamY: Name and address offee�e// simple titleholder Of different from Owner listed above): Centractcr's Name: zw c� ContmdorAddress, Phone Number: Surety (if applicable, a copy of the payment bord is attached): Amount of bond: $ Nameandaddress: Phn—rinnhar- Lender's address: Persons within the State of Florida designated by Owner upon whom notices a other documents may be served as Provided by Section 713. ,;(1) (9)7, Florida Statutes: Name:. - Phone Number: _ .. In addition W himtelfor herself, Ownerdesignates of to receive a copy ofthe Lien is Notice as provided In Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner. Expiration date of notceof commencement: (the expiration date myna be before the completion of construction and final payment to the ammeter, but will be 1 yearfrom the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNERAFIERTHE EXPIRATION OF THE NOTICE OFCOMMENCEMENTARE CONSIDERED IMPROPER PAYMENTSUNOER CHAPTER 713, PART I, SECFlON 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TOYOUR PROPERTY. A NOTICE OF COMMENCEMENT MUSr BE RECORDED AND POSTEDONTHEJOB SITE BEFORE THE FIRST INSPECTION. IFYOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORAN ATTOIINEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I decla atlhave ead the foregoing notice of commencement and thatthe facts stated therein are We to the best of my knowledgean Celief. WS) Nreof nerorLessee, vner's or lessee's Authorized Officer/Director/Parmer/Man9aneeEiiruHO.+YREbIINer+am y (Signatm(s Tde/OlChce) Theforegoinginstrument was acknowledged before rive this �aayo(_yY , 20 1,4 Name of Person Typ�e of authority (e.g. officer, trustee) Parry on behalf of whom instrument was msecuted V Personalty known_ or produced ldentillcation (Sigunumuf aryPublic-Stateof Flod ) V (Print Type, o Stamp Commissioned Name of Notary Public) Type of Identification produced •O!""-C/r �• STATE OF FLORIDA ST. LUCIE COUNTY THIS IS TO CERTIFY THAT THIS IS A TRUE AND CORRECT COP OF THE ORIGINAL. 0 ,tSSMITH, Dt1W' DVCt U1'f1L Dale, *-� .1J NIAMI al- FfC /�//-013l O E 60py MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) w .miamidade.¢av/oera Interwrap, Inc. 32923 Mission Way Mission, BC, Canada V2V-6E4 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Titanium-UDLTM 30 / Titanium PSU-30 and Titanium-UDLTM 25 PLUS / TitaniumTM PSU-30 Underlayment System LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 5. The submitted documentation was reviewed by Jorge L. Acebo. APPNOYED NOA No.: 11-0815.05 Expiration Date: 01/26/17 Approval Date: 01/26/12 Page 1 of 5 ROOFING COMPONENT APPROVAL Cateeorv: Roofing Sub-Cateeorv: Underlayment Material: Polypropylene TRADE NAMES OF PRODUCTS MANUFACTURED BY APPLICANT TABLE 1 Product Dimensions Test Product Specification Description Titanium -UDC 25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with PLUS Type I & U one side coated with UV protected and slip resistant polymer stabilized polypropylene on Manufacturing both sides. Location #1& #2 Titanium-UDL" 30 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with Type I & II two sides coated with UV protected and slip Manufacturing resistant polymer stabilized polypropylene on Location 01& #2 both sides. Titanium" PSU-30 36" x 72' rolls TAS 103 Unreinforced polymer modified bitumen material adhered to the underside of a Manufacturing polymer -coated, synthetic woven sheet. The Location #3 underside is backed with a release film. MANUFACTURING LOCATIONS: 1. MLI 2. ML3 3. ML4 EVIDENCE SUBMITTED: Test Aeency Test Identifier Test Name/Reyort Date Intertek Testing Services #3031783 TAS 104 02/19/03 3119607COQ-003B ICC-ES AC48 02/20/08 3124826-01 ASTME108 02/19/08 3124826MID-007 ASTM E108 02/25/08 311801000Q-003 ASTM D226 02/20/08 3130639COQ-002A ASTM D226 02/20/08 3146738COQ-003A ASTM D226 04/22/08 3146738COQ-003B ASTM D 1876/ TAS 117 03/28/08 Trinity I ERD I15010.05.10 ASTM D4798 / D226 05/14/10 135520.06.11 TAS 103 / TAS 104 06/15/11 I38010.08.11 ASTM D226 08/11/11 135520.08.11 ASTMD2523/D1781 08/17/11 135520.08.11-1 TAS 114 08/12/11 135520.06.11 TAS 103 / TAS 104 06/15/11 NOA No.: 11-0815.05 Expiration Date: 01t26/17 Approval Date: 01/26/12 Page 2 of 5 APPROVED TITANIUM UNDERLAYMENT SYSTEM ASSEMBLIES: Deck Type 1: Wood Deck Description: 19/32" or greater plywood or wood plank System E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. Base sheet: One or more plies of Titanium-UDLTm 25 PLUS or Titanium-UDLTM 30 applied with minimum 4" horizontal laps and minimum 6"vertical laps and mechanically fastened as noted below. Note: Titanium-UDLTM 30 shall be inverted to provide a smooth bonding surface. Primer is not required when Titanium- UDLTM 30 is installed inverted (printed side facing down) Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Primer: Metal/Tin caps shall be primed with ASTM D41 primer Ply Sheet: (Optional) Titaniunim PSU-30, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: TitaniumT^' PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first course of TitaniumTM PSU-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the file manufacturer's NOA. For foam -on tile roof assemblies, approved use with Polyfoam Products PolyPro AH160 and Dow TileBond. NOA No.: 11-0815.05 Expiration Date: 01/26/17 Approval Date: 01/26/12 Page 3 of 5 Deck Type 1: Wood Deck Description: 19/32" or greater plywood or wood plank System E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. All General and System Limitations shall apply. Base sheet: One or more plies Titanium-UDLTM 30 applied with minimum 4" horizontal laps and minimum 6"vertical laps and mechanically fastened as noted below. Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8" o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet. Primer: Titanium-UDLTM 30 shall be primed on the printed side with ASTM D41 primer prior to placement of cap sheet. Ply Sheet: (Optional) Titaniunim PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Titaniunfm PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6" vertical laps. Place the first course of TitaniumTM PSU-30 parallel to the eave, using a heavy pressure roller under safe conditions to further secure the membrane. Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For foam -on tile roof assemblies, approved use with Polyfoam Products PolyPro AH160 and Dow TileBond. NOA No.: 11-0815.05 Expiration Date: Ol/26/17 MIAMMADECOUNTY Approval Date: 01/26/12 Page 4 of 5 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Titanium Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Titanium-UDLTm 25 PLUS and TitaniumTM PSU-30 or Titanium-UDLTm 30 and Titaniumn" PSU-30, two-ply underlayment system, may be used in asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies. 5. The standard maximum roof pitch for the Titanium-UDLTM 25 PLUS and TitaniumTM PSU-30 or Titanium-UDLTm 30 and TitaniumTM PSU-30 two-ply underlayment system shall be 5:12 for flat tiles and 6:12 on profiled tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles shall be staged 2 base tiles perpendicular to slope behind a mechanically attached batten or toe board with maximum 7 tiles high on the slope atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. 6. Titanium Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system. 7. Titanium-UDLTM 30 / TitaniumTM PSU-30 and Titanium-UDLTM 25 PLUS / TitaniumTM PSU-30 two- ply underlayment system shall not be left exposed as a temporary roof for longer than 90 days of application. & Titanium Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 9. Titanium Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If Titanium Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturers name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 11-0815.05 Expiration Date: 01/26/17 Approval Date: 01/26/12 Page 5 of 5 Vo--z Force Engineering & Testing Inc. 19530 Ratable d Dtivc Hmnble,TX 77338 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. 5V Crimp Roof Panel over 15132" Plywood Florida Product Approval # 11651.12 RI Florida Building Code 2010 Per Rule 9N-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method:9N-3.005(1)(d) HVHZ Product Manufacturer: GULF COAST SUPPLY & MANUFACTURING, U.C. 4020 S.W. 449th Street Horseshoe Beach, Florida 32648 Eneiheer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID:1920 Validator: Locke Bowden, P.E., FL #49704 9450 Alysbury Place Montgomery,AL 36117 Contents: Evaluation Report Pages 1-4 I%r lft„'r', C B N A. No. 449 ^•�• STATE OF :at � tv se.enaad ♦ ,p •. t FI.# 11651.12 R1 February 23, 2012 rForceEngineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2010, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Product Description: SV Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel over 15/32" Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2010 Section 1507.4.3. Paint Coating: Valspar Fluropon Coating (Optional) Yield Strength: Min. 50.0 ksi Corrosion -Resistance: Panel Material shall comply with Florida Building Code 2010, Section 1507.4.3 Panel Dimension(s): Thickness: 0.018" min. - Width: 24" Coverage Rib Height: 3/8" major rib Panel Rollformer:. Rollformer Corp. Panel Fastener: Substrate Description: Design Uplift Pressures: #9-15 x 1-1/2" WoodZac w/ Zac Head with sealing washing through panel rib. X" minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4 Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2010. Table "A" Maximum Total uplift Design Pressure: 108.5 Psf 156.5 Psf Fastener Pattern: Panel Rib Panel Rib Fastener Spacing: 12" O.C. 6" O.C. -Design Pressure includes a Safety Factor= 2.0. I H I II rI'P"I C E. E. WO �i�i C 2 N s a+ NO. 4109 * "S STATE OF ; t O RI 9 A •�4i i�°sm ��,I�� /OMALE�G��♦ FL# 11651.12 R1 February 23, 2012 U Force Engineering & Testing Inc. 19530 Ramblmvod Drive Iiumble,TX 77338 �J Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2010, Section 1504.3.2, 1518.9, 1523.6.5.2.4. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2010, as relates to Rule 9N-3. Performance Standards: The product described herein has demonstrated compliance with: • TAS 125-03 • UL580-06- Test for Uplift Resistance ofRoof Assemblies • UL 1897-04 - Uplift Test for Roof Covering Systems • TAS 100-95 -Test Procedure for Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems • TAS 130-00 - Accel. Weathering ASTM G 26 / Salt Spray ASTM B 117 Reference Data: 1. TAS 125-03: UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-006ST-07A-C, Dated 01/26/2007 2. TAS 100-95 Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654) Report No. T130-07, Dated 02/28/2007 Report No. T215-08, Dated 07/08/2008 3. TA5110-00: Valspar Fluropon coated metal panel testing A) ASTM G 26 by PRI Asphalt Technologies dated OV19/2004 B) ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004 4. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization #ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. FI.# 11651.12 PA n r r i r e/r�' �1cENSFt�., l� N 4A2g t �'° • STATE OF : a AL O RI'D A .z"% auoim �I �lO tl[rt\?G, �% February.23, 2012 U Force Engineering &Testing Inc. 19530 I.tamblewood Drive $umble,TX 77338 Minimum Slope Range: 2:12. Minimum Slope shall comply with Florida Building Code 2010, including Section 1515.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details and RAS 133. Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section 1518.2, 1518.3, 1518.4. Fire Barrier. Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: 'Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2010 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2010 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. C, lC No. STA 0 ON FL# 11651.12 R1 February 23, 2012 26 Ga. 5V Crimp Roof Panel ove. c_u r MIAAb cvoneenzecrenlco tweTrm . tdhn%n1DPwNs �StH A 192 FMRICA71p4M110N; to i r O.C. MAIN FIELD FEWMETER lR Ot FILL CU N CMA SElV `7Ef:IWiCP1:WRR. mom: Y t Y AHY HAu7u w mwr. 19A6a 1• &WoOtvAc w(zN� HEAD 26 Ga. SV Crimp Roof Panel over 1/211 'kywoc5d ENg F. A" • 0.449 r OIAL. FQW� PA 10914 -74 5V 'FEB 101012 27-1/2° Flat Stick MQteriat For 24" Cover*age Note - All Radii 0.05 —7/16' -5/8t" FIxed Overlap Ribs N .26 For 24' Coverage 12' - 24' Covpr'oLo.e Adjustabte Center R6 Property Appraiser - St.Lucie County, FL Page 1 of 1 Luis Martinez Record: 1 of 2 Property Identification Site Address: 4911 Southwind Trl Searro.wRange: 18 :34S :40E Map ID: 14118N Zoning: AR-1 Ownership and Mailing Owner Luis Martinez Cathy Martinez Address: PO Box 690024 Vero Beach FL 32967 Sales Information Data Pace Code 10/512001 8500 00 877/1999 100 04 8/8/1997 100 01 10/1/1974 6000 00 N PROPERTY RECORD CARD "Prev Next>> Spec.Assmnt Taxes Par.IID: 1418-244-00R5-000.1 Account #: 8wa Use Type: SF Res City/Cnty. Saint Lucia County Exemptions Permits Home Print �1�,11C1E �G �y Legal Description 18 3440 NE 1/4 OF BE 1/4 OF BE 114 OF NW i/4-LESS E 30 FT- (2.32 AC) (OR 1445. 218:1426-466) Assessment 2014 Deed BwVPage 2014 TRIM: 2143DO WD 1445/0218 Assessed: 200666 WD 1166/1342 Ag.Credit: 0 DC 1094/1830 Exempt 50000 CV 0234/2101 Taxable: 15DWG Taxes: 3172.67 BUILDING INFORMATION Total Land and Building Larxl Veluei 59700 Acres: 2.32 BuiVing Value: 154600 Finished Area: 2532 SgFt extenor reatures View: - RwfCover. SD - Dim Shingle RoofStruct GA - Gable EMType: HC - He YeerBlh 2002 Frame: - Grade: C-C EfiYlBit 2002 PrimeWall: LG - Logs StoryHght 0020-2 Story No.Unfls: 1 SnWall: LG - Logs Interior Features BedRooms: 4 Electra MX-MAXIMUM P.ImWell: DW-Drywall FullBathi 2 HeatType: FHA -FndHotAlr AvgHUFI' 1/2Bath: 1 HeafFuel: ELEC- Electric PartFlors: HW- Hardwood 36AIC: 100 ;6Heated 100 46Spnnkled: 0 Special Features and Yard Items Land Information Type Y/S Dry. Units Oual. Cond, W&L No. Use Type Type Measure Depth ENC2 - POOL ENC-AVG Y 1 1064 AV AV 2010 1 0100-SF Res 125-Acres 2.32 SWAV - RES POOL AVG Y 1 512 AV AV 2010 PA02 - POOL OK -GOOD Y 1 552 AV AV 2010 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/paslc/pre.asp?prclid=141824400050001 9/19/2014 F SV-CRIMP 5V-CRIMP SEE DETAIL 1 L UNDERLA`1MENi SHALL BE INSTALLED I/ \ `8d x 2.5" LONG RING SHANK NAIL AS PER MANUFACTURER'S INSTALLATION VV��II OR 8 x 2" LONG WOOD SCREWS GUIDELINES MIN. 2X_ WOOD RAFTER/JOIST SPACED 0 6" O.C. IN THE. FIELD & TRUSS AT MAX, 24" O.C. AT PLYWOOD EDGES tha;� FASTENER PATTERN AT INTERMEDIATE 0 ATION SEE DET(dL-`7 24" I UNDERIAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL AS PER MANUFACTURER'S INSTALLATION GUIDELINES OR 08 x 2" LONG WOOD SCREWS 2X_ WOOD RAFTER/JOIST/ SPACED 0 6" O.C. IN THE FIELD & i AT MAX. 24" O.C. AT PLYWOOD EDGES FASTENER PATTERN AT PANEL ENDS TYPICAL PANEL INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING "MAT MAXIMUM SPACING OF 24" O.C. 5V-CRIMP MIN 26 Ca. THICK (MIN.) (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 24 84.5 18 131.3 12 149.6 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). _ 2. ROOF PANELS SHALL BE MIN, 26 GA. (L = 0.017-). EFFECTIVE COVERING WIDTH OF PANEL = 24". SPECIFIED ON THIS DRAWING. UNDERIAYMENT 2 ' PLYWOOD 4. REWIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS 19/32" THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. S. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA q DETAIL 1 BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS DP THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 80 ry a r� of Florida Building Code Online BCIS Home I Log In I User Registration i Hot Topics I Submit Surcharge I Stars & Facts 1 Publicotlons I FBC Staff -751 Product Approval iF USER: Public User Product Approval Meng > PQKJ ct Or A D0110tig-Search > Aodicatinn Lit > Appacatlon oetail Fl. # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL14645-R1 Revision 2010 Approved Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 (812) 218-7342 dstermer@metaisales.us.com David Stermer dstermer@metalsales.us.com Roofing Metal Roofing Evaluation Report from a Florida Registerec Florida Professional Engineer Evaluation Report - Hardcopy Received Bala Sockalingam PE-62240 Keystone Certifications, Inc. 12/31/2015 Yoosef Lavi, P.E. e Validation Checklist - Hardcopy Standard FM 4470 TAS 125 UL1897 UL580 Florida Licensed Professional Engineer or BCIS Site Map I Unks I Sesrch Architect or a Licensed Year 1992 2003 1998 1994 114 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 12/09/2011 Date Validated 12/13/2011 Date Pending FBC Approval 12/16/2011 Date Approved 01/31/2012 bummary of Products FL* Model, Number or Name Description 14645.1 2.5" Corrugated Min. 26 ga., 21.33" wide throuill fastened roof panel over min. 19/32" thick plywood deck. Limits of Use Installation Instructions Approved for use In HVHZ: No FL14645 RI II D1800 26 odf Approved for use outside HVHZ: Yes E 62240 Verified By: Bala Sockalingam Impact Resistant: N/A Created by Independent Third P rty: Yes Design Pressure: +N/A/-86.0 Evaluation Reports Other: Uplift load of 82.3 psf @ fastener spacing of 36" o.c. EL14645 R1 AE Evaluationge,acriCi8flo and 86.0 psf @ fastener spacing of 12" o.c. Created by Independent Third F arty: Yes 14645.2 SV-Crimp Min. 26 ga., 24" wide through fa tend roof panel over min. 15/32" thick plywood deck with asteners through panel rib. Limits of Use Installation Instructions Approved for use In HVHZ: No FL14645 RI II D1800 27 odf Approved for use outside HVHZ: Yes E 62240 Verified By: Bala Sockalingam Impact Resistant: N/A Created by Independent Third P rty: Yes Design Pressure: +N/A/-76.7 Evaluation Reports Other: Uplift load of 58.5 psf @ fastener spacing of 24" o.c. EL14fi4lonRepr and 76.7 psf @ fastener spacing of 15" o.c. Created by Independent Third P rty: Yes 14645.3 SV-Crimp Min. 26 ga., 24 wide through fas ened roof panel over min. 19/32- thick plywood deck with asteners through panel flat. Limits of Use Installation Instructions Approved for use In HVHZ: No FL14645 RI 11 D1800 28 odf Approved for use outside HVHZ: Yes E 62240 Verified By: Bala Sockalingam I Impact Resistant: N/A Created by Independent Third P rty: Yes Design Pressure: +N/A/-149.6 Evaluation Reports Other: Uplift load of 84.5 psf @ fastener spacing of 24" o.c., EL14645 R1 AE EvaluationgericlQ18no 131.3 psf @ fastener spacing of 18" o.c. and 149.6 psf @ Created by Independent Third P rty: Yes fastener spacing of 12" o.c. 14645.4 SV-Crimp Min. 26 ga., 24" wide through fastened roof panel over min. 19/32' thick plywood deck with fasteners through panel rib. Limits of Use Installation Instructions Approved for use In HVHZ: No FL14645 RI II D1800 29 odf Approved for use outside HVHZ: Yes E 62240 Verified By: Bala Sockalingam F Impact Reststantt N/A Created by Independent Third Pi irty: Yes Design Pressure: +N/A/-131.1 Evaluation Reports Other. Uplift load of 41.6 psf @ fastener spacing of 36" o.c. R14645 RI AE Evaluationgepp and 131.1 psf @ fastener spacing of 6" o.c. rty: Yes Created by Independent Third P 14645.5 Aluminum Classic Rib Nom. 0.032" thick, 36" wide, alu nimum through fastened roof panel over min. 15/32" thicl plywood deck or 7/16" thick OSB. Limits of Use Installation Instnuctions Approved for use In HVHZ: No FL14645 RI If D1800 30 odf Approved for use outside HVHZ: Yes Impact Resistant: N/A E 62240 Verified By: Bala Sockalingam I Design Pressure: +N/A/-120 Created by Independent Third P Evaluation Reports rty: Yes Other: Uplift load of 30 psf @ fastener spacing of 36" o.c. FL14645 RI AE EvaluationRepo tCI800 30 f and 120 psf @ fastener spacing of 6" o.c. rty: Yes Created by Independent Third Pi 14645.E Nom. 0.032' thick, 16" wide, alu Imum standing seam roof =lumlnumVerllcaleam panel over min. 15/32" thick plyi Pood deck or 7/16" thick OSB. Limits of Use Install Install on Instructionsation Approved for use In HVHZ: No 5 ti D1800 1 odf Approved for use outside HVHZ: Yes Impact Resistant: N/A 62240 Verified By: Bala Sockalingam P Design Pressure: +N/A/-97,05 Created by Independent Third Pi Evaluation Reports rty: Yes 7param=wGEVXQwtDgsw8ZVNfe8A7ecHQhC9itQCiw2RiaSsF%2flY6GhrJWm DQ%3d%3d 214 Florida Btuldirlg Code Orlin Other: Uplift load of 41.55 psf @ clip spacing of 36' o.c., 71.0 psf @ clip spacing of 12" o.c. and 97.05 psf @ clip spacing of 12" o.c. with sidelap adhesive. EL14645 RI AE EvaluatlonReD4 rtCI800 31.ndf arty: Yes Created by Independent Third I 14645.7 Classic Rib Min. 26 ga., 36" wide through fz stened roof panel over min. 19/32" thick plywood deck. Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-133.9 Other. Uplift load of 74.8 psf @ fastener spacing of 36" o.c., 92.3 psf @ fastener spacing of 24' o.c. and 133.9 psf @ fastener spacing of 18" o.c. FL14645 R3 II D1800 32 odf E 62240 rty: Yes 32,pd Yes Verified By: Bala Sockalingam Created by Independent Third Evaluation Reports EL14645 RI AE EYaluationRep(MC1800 Created by Independent ThirdParty: 14645,8 Classic Rib Min. 29 ga., 36" wide through fastened roof panel over min. 7/16'thick OSB deck Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135.0 Other: Uplift load of 45 psf @ fastener spacing of 24" o.c. and 135 psf @ fastener spacing of 6" o.c. Installation Instructions R14645 RI 11 D1800 33.odf E 62240 Yes arty: Yes Verified By: Bala Sockalingam Created by Independent ThirdParty: Evaluation Reports FL14645 RI AE Evaluationgelf0 Created by Independent Third P 14645.9 Classic Rib Min. 29 ga., 36" wide through fastened roof panel over min. 15/32" thick plywood deck. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5 Other. Uplift load of 68.4 psf @ fastener spacing of 24" o.c. and 138.5 psf @ fastener spacing of 12" o.c. Installation Instructions FL14645 RS II 01800 34 odf E 62240 arty; Yes Yes Verified By: Bala Sockalingam Created by Independent Third P Evaluation Reports EL14645 RI AE EvaluationRepertCI800 Created by Independent Third Party: 14645.10 Image 11 Min. 26 ga., 16" wide concealed fastened roof panel over min. 15/32" thick plywood deck it 7/16" thick OSB. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.55 Other: Uplift load of 20.75 psf @ fastener spacing of 24" o.c., 63.50 psf @ fastener spacing of 6" o.c. and 86.55 psf @ fastener spacing of 6" o.c. with sidelap adhesive. Installation Instructions FL14645 RI 11 D1800 35 odf E 62240 Yes 35.pdf Yes Verified By: Bala Sockalingam Created by Independent Third Party: Evaluation Reports EL16645 RI AE EvaluationRepertC1800 Created by Independent Third Party: 14645.11 PBR-Panel or R-Panel Min. 26 ga., 36" wide through fattened roof panel over min. 19/32" thick plywood deck. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0 Other. Uplift load of 30.0 psf at fastener spacing of 48" o.c. and 131.0 psf at fastener spacing of 6" o.c. Installation Instructions FL14645 RI II D1800 36 odf 62240 rty: Yes Verified By: Bala Sockalingam RE Created by Independent Third P Evaluation Reports EL14645 RI 6E EvaluationRep36.pdf EL11645 R1 AE LSCj800 36.pd Created by Independent Third P rty: yes 14645.12 Pro -Panel 11 Min. 29 ga., 36" wide through fastened 15/32' thick plywood deck. roof panel over min. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.5 Other: Uplift load of 41.6 psf @ fastener spacing of 24" o.c. and 71.5 psf @ fastener spacing of 12" o.c. Installation Instructions FL14645 R3 11 D1800 37 odf E 62240 irty: Yes irty: Yes ' Verified By: Bala Sockalingam I Created by Independent Third Pi Evaluation Reports EL14645 RI 8E EyaluationgepotC1800 Created by Independent Third Pi o".A Fnt ' Contact US:: 1940 Man Mere Street Tallatia,,e FL aaaoo Ptmne: 850-487-1024 The State of Florida is an AA/EEo e111Pleyef. CnOydnilt 2007-2013 State of Florida :: P6va" Statement :: A es4aili tatement :: Refu Statement 3/4 ` 11/312Q14 Florida Building Code Ordirte 11 Under Florida law, email addresses are public records. Ir you do not want your e-mail address released In response to a public words request, do not sent electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please mrrtaG 0.487.1395. *Pursuant fo Section 455.275(1), Modal Statutes, effective October 1, 2012, licensees licensed Untler Chapter 455, F.S. must provide the Departnt with an email address If they have one. The emalls provided may be used for official communication with the licensee. However small addresses am public re ard. If you do net wish to supply a personat address, please provide the Deportment with an email address which can be made available to the public. To determ ne If you are a licensee under Chapter 455, F.S., please dick her _. product Approval Accepts: M M M securil'na, %I, 4/4 Treasure Harvey E. Koehnen ' Coast Professional Engineer#32831 Building Architect#AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. Contractor 6-rLl.nl'r LC. gQqFImt& Owner _PAA%L-[t14a;E Job Address 41, 4 1 sourrtvtltJD METALROOFINGjiVt,FGo%gT 5V -1&4Ar NEW ROOF_ RE -ROOF )C REPAIR_ AREA fill r^II AL ROOF PLAN A;r:tt,_u o Q i ler-rLA0-CLG/ 7iQ�fK� 7205 Elyse Circle P 5 L Florida 34952-8212 PHONE(772)466-5509 FAX(772) 4893035 E-MAIL•hkoehnen@trbeweb.com Date t1 « ZL% ASCE 7-10 & FBC 2010 ENCLOSED BLDG X SEMI ENCLOSED BLDG OPEN PART2• LOW RISE C&C SIMPLIFIED for 31YZ RISKC172/V= f o EXPOSURE 13 /A= 1,b /K2t=1.0/h z!Lj - /12PITCH ROOF SYSTEM (OB.5 AFL 11&!S& 1 _ ?Q ZONE IP@ @ h=30 = X - PSFX0.6=-2�-3 ZONE 2 P @ @ h=30 = X = PSF x 0.6 = +'t4 f a = ZONE 3P@ @ h=30 = X = PSFx0.6=-!oh•� a= 1 MAX DESIGN PRESSURE PER NOA !_\ DECKT�YY••PE rLY WDOD THICKNESS C5/32r• tw o. BASS tffi � NO. OF PLIES FASTENER TYPE SPACING PLY SHEET NO. OF PLIES FASTENER TYPE SPACING TOP PLY NO, OF PLIES FASTENERTYPE SPACING INSULATION BASE LAYER TYPE SIZE TYPE OF FASTENERS: SPACING FIELD PERIMETER CORNERS INSULATION TOP LAYER TYPE SIZE TYPE OF FASTEN ERS/QRannr SAL q�15 �1%z"Wood 6G wrzk DRIP EOGE SIZE DRIP MATERIAL 2Iv L%k&.( FLASHING MATERIAL '+4 4A 6-4- FASTENER SPACING FOR METAL ROOF PANELS; FIELD LV PERIMETER 12•• CORNERyatJEr- �"�'ERr.M T reasure Harvey E. Koehnen C oast Professional Engineer #32831 B uilding Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. `these Tables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof Height of 30' or Less Located In Exposures B, C or D Table R301.2 [2]-P.Iz ytyuPJ-- 3b,5-( As --a 7-Ib COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]. 160 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D (One story (Two story*) (One story') (Two story" Roof > 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 40.6 -45.9 7degrees = 11/2 /12 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1 Zone 3 -69.8 -84.5 ' -97.7 -102.7 -115.9 Zone 1 25.3 30.7 -35.5 37.2 42 =7toes tch Zone 2 -44,1 - 53.4 - 61.8 -64.9 - 73.3 Zone 3 -65A 78.8 - 91.2 - 95.7 - 108::1 Roof > 27 to 45 degrees Zone 1 - 27.8 -33.7 40.0 -40.1 -46.2 45 degrees = 12/12 pitch Zone 2 - 32.4 -39.3 -45.4 -47.7 -53.8 Zone 3 - 32.4 -39.3 -45.4 - 47.7 -53.8 160 Exp B 150 Exp C 150 Exp C 150 Exp D 150 E# D . (one story*) ( two story*) (one story*) (tvdo story`} Roof > 0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7degrees = 11/2112 pitch Zone 2 -40.8 -49A -57.2 -60.0 -67.8 Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0 Roof > 7 to 27 degrees Zone 1 -22.2 - 26.9 - 31.1 -32.7 - 36.9 27 degrees = 6/12 pitch Zone 2 -38.7 - 46.9 -54.2 -56.9 - 64.3 Zone 3 . -57,3 - 69.4 - 80.3 -84.3 - 95.2 Roof > 27 to 45 degrees Zone 1 - 24.3 -29.5 -34.1 -35.8 -40.4 45 degrees = 12/12 pitch Zone 2 - 23A -34,4 -39.8 -41.8 -47.2 Zone 3 - 28.4 -34.4 -39.8 -41.8 -47.2 One Story* = one story building with a maximum mean roof height of 15 feet Two story* = two story building with a maximum mean roof height of 30 feet If allowed by the Miami Dade N.O.A or Florida Product Approval, anysystem.that does not meet the minimum components and cladding pressures for the area that the building Is located per this form may require a Florida licensed engineer to revise the fastener spacing T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509 Port Saint Lude FAX (772) 489-3035 Rorida 34952-8212 E-MAIL hkoehnen@tcbeweb.com R JForce Engineering & Testing Inc. 19530 Raznbke od Drive H=ble,TS 77338 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC, 26 Go. 5V Crimp Roof Panel over 15/32" Plywood Florida Product Approval # 11651.12 R1 Florida Building Code 2010 Per Rule 9N-3 Method: I —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 9N-3.005(1)(d) HVHZ Product Manufacturer: GULF COAST SUPPLY& MANUFACTURING, LLC. ' 4020 S.W. 449`" Street Horseshoe Beach, Florida 32649 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID:1920 Validator: Locke Bowden, P.E., FL #49704 ^1\� 94SO Alysbury Place Montgomery, AL 36117 , Contents: Evaluation Report Pages 1-4 sranrf i Ambc FL# 11651.12 R1 O c e Ny7 No. 4 ,/ STATE OF ALoR19� February 23, 2012 wr- Force Engineering & Testing Inc. 19530 RambIcmvod Drive / Hwnblc,TX 77338 Minimum Slope Range: J 2:12. Minimum Slope shall comply with Florida Building Code 2010, including Section 1515.2 and In accordance with Manufacturers recommendations. Foi slopes less than 3:12, lap sealant must be used In the panel side laps. Installation: Install per manufacturer's recommended details and RAS 133. Underlayment: Per Manufacturer's Installation guidelines per Florida Building Code 2010 Section 1518.2, 1518.3, 1518.4. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2010 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2010 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. FL# 11651.12 R1 ,Jil ItEIt', � / IY 40! 'o • STATE OF i '0'Fx0IL1.0 4� NA III February 23, 2012 Force Engineering & Testing Inc. 19530 Rwnblewood Dtive — Humblc,TX 77338 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2010, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Product Description: ✓SV Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel over 15/32" Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2010 Section 1507.4.3. Paint Coating: Valspar Fluropon Coating (Optional) Yield Strength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2010, Section 1507.4.3 Panel Dimension(s): Thickness: 0.018" min. Width: 24" Coverage Rib Height: 3/8" major rib Panel Rollformer: Rollformer Corp. Panel Fastener: V/49-15 x 1-1/2" WoodZac w/ Zac Head with sealing washing through panel rib. N" minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2010, Section 1505.6, 1507.4.4 Substrate Description: Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2010. Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 108.5 psi 1S6.5 psi Fastener Pattem: Panel Rib a ib Fastener Spacing: 12"D.C. "O. "Design Pressure Includes a Safety Factor = 2.0. {{ %%%% C E• •L'.• Wp ,�Ai `� •'•o• STATE OF :r sroirsm 00 FS • • 1�� ism ',0,$�oNnst0{G{,, FL# 11651.12 R1 February 23, 2012 ) I Force Engineering & Testing Inc. 19530 Rnmblmvod Driw Humblc,T X 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2010, Section 1SO4.3.2, 1518.9, 1523.6.5.2.4. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2010, as relates to Rule 914-3. Performance Standards: The product described herein has demonstrated compliance with: • TAS 125-03 UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-04 - Uplift Test for Roof Covering Systems • TAS 1CO.95 -Test Procedure for Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems • TAS 110-00 - Accel. Weathering ASTM G 26 / Salt Spray ASTM B 117 Reference Data: 1. TAS 125.03; UL 580-94 / 1897.98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TSr-5328) Report No. 117-0065T-07A-C, Dated 01/26/2007 2. TAS 100-95 Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654) Report No. T130-07, Dated 02/28/2007 Report No. T215-08, Dated 07/08/2008 3. TAS 110-00: Valspar Fluropon coated metal panel testing A) ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004 B) ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004 4. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # AN ID: 1920) Test Standard Equivalency: 1. The UL SSG-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products In accordance with the Florida Building Code and Rule 9N-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. `tt3t1s1l 11111J C @ fV y No. 40 �1(�(Ff*r/ STATE OF : C Z0RIAA,.�4.,. s'•.. NA FM 11651.12 Rl February 23, 2012 26 Ga. 5V Crimp Roof Panel over 1 2" Plywocid. -n rn CD o:: co: N O_ N S-V CRIMP EXPOSED FASTENER SYSTEM W GHW PANED � WATWA00F MEMBRANE 12" O.C. MAIN FIELD 6' O.C. PsmAFFER NATOMOP11" iQ16110P71ON8 A""- ISTM A 792 K CD[ItLI cultm c nwvr [L liEQUW. AMr x l0iw aulTr. FAMPAYMCPfWJS STM 4 TEOFQNJLDATII •94sx T•ltl'WOOCTAC wJZ4G 0940 26 Ga. 5V Crimp Roof Panel over 1/211 otr����c1GE E• 1, 100 a°J6 •mrre � F� N0.449 T FR A ROU CORP. gg 1901HOEPQSOfaBCE LANE IMOU 11[6=L4 R .P /: (S 6ULFONr. PA 18114 5 V FEB6•g 2012 27-1/2' Flat; Stbck Material For 24' Coverage Note : All Radii 0.05 12NO V 99 —7/16" 1-5/8. Fixed Overlap Ribs 26„ For 24' Coverag 12" — 24' Coverac f8; Adjustabte Center Rib Ad ju,taole Underlap Ribs Florida Building Code Online Page 1 of 2 �I��'I'r ' pevgxptr<' veou{oam povaolaoipxa' cpxrACf oopA Florida Depr[areeenntdl SmSH.— tagln User&egistrstion Hot Topics Submitsu,ahaMe Stats&Farts Busines(`;1 Product Approval nal �I usER. Public User Professi Regulation 1�aaltlllleHlG1�'14�t11� Product Aoomval Menu > Product or Application Search > Aoollcaron List> Applimtion Detail agm FL # FL11602-R2 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer InterWrap, Inc. Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 (551) 574-2939 mtupas@interwrap.com Authorized Signature Technical Representative Address/Phone/Small Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Eduardo Lozano elozano@interwrap.com Eduardo Lozano 32923 Mission Way Mission, NON -US 00000 (778) 945-2691 elozano@lntemrap.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed , Florida Professional Engineer {�1 d Evaluation Report- Hardcopy Received A7 Robert Nieminen - PE-59166 Intertek Testing Services NA Inc.- EfL/Warnock Hersey 09/06/2015 John W. Knezevich, PE r1h J Validation Checklist - Hardcopy Received Fill 1602 R2 COI Trinity ERD CI - N'em'nen Ddf 1507.2.3 1507.2.4 1507.2.9.2 1507.3.3 1507.5.3 1507.7.3 1507.8.3 1507.9.3 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5Ke/b2fI'... 11 /18/2014 Florida Building Code Online Page 2 of 2 1507.9.5 1523.6.5.2.1 Product Approval Method Method 2 Option B Date Submitted 02/17/2012 Date Validated 04/18/2012 Date Pending FBC Approval 02/27/2012 Date Approved 04/23/2012 Summary of Products FL # Model, Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-45 Other: 1.) The design pressure noted herein pertains to use of a specific underlayment system beneath foam -on tile sytsems. Refer to ER Section 5.5.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Installation Instructions FL11602 R2 II er021712FINAL INTERWRAP FL31602- R2.Ddf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL11602 R2 AE er021712FINAL INTERWRAP FL11602- R2.odf Created by Independent Third Party: Yes sack Neat Monroe S[motZTallahassee R 32399 Phan The State of Florida Is as AA/EEO employer. Coovrloht 2007-2013 State of Floridil:: Privacy Statement :: Accesslbllit, Statement :: Ref ader Florida law, email addresses are public records. If you do not want your e-mall address released in response W a public -records request, do not send carbide mall to thls entity. Instead, concoct the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Ion 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if y have one. The emalls provided may be used for official communication with the Iloansee. However email addresses are public record. If you do not wish to a personal address, please provide the Department with an email address which can be made avallable to the public To determine If you are a licensee under chapter 455, F.S., please click here . Product Approval Accepts: CreditS�I FrL http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fr... 11/18/2014 TRINITY ! ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Interwrap, Inc. Evaluation Report I11980.11.08-112 32923 Mission Way FL11602-R2 Mission, BC V2V-6E4 Date of Issuance: 11/03/1008 Canada Revision 2: 02/17/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: TitaniumTM Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facslmile seal appearing was authorized by Robert Nieminen, P.E. on 02/17/2012 This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products It evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved in the approval process of the product. J TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titanium*"' Roof Underlayments, as produced by Interwrap, Inc., have demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, Unrolling, Breaking Strength, ASTM D226 2006 1507.7.3, T1507.8, 1507.8.3, Pliability, Loss on Heating 1507.9.3, 1507.9.5 1507.2.4, 1507.2.9.2, 1507.5.3 Thickness, Load -Strain, Adhesion, ASTM D1970 2001 Thermal Stability, Flexibility, Tear, Permeance 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Dimensional Stability, Tear, Load- TAS 103 1995 Strain, Water Absorption, Low Temp Flex, Cyclic Elongation, Puncture, Crack Cycling, Peel Adhesion, WVT, Tile Slippage TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties I15010.04.09 04/29/2009 ERD (TST6049) Physical Properties I15010.05.10 05/14/2010 ERD (TST6049) Physical Properties I35520.06.11 06/15/2011 ERD (TST6049) Wind Uplift I35520.08.11-1 08/12/2011 ITS(TST1509) Physical Properties 3146738COQ-003A 03/28/2008 ITS (TST1509) Physical Properties 3146738COQ-003B 03/28/2008 ITS (TST1509) Physical Properties 3126617000-005 10/31/2007 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Inspection Report 12/13/2011 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlayments• 4.1.1 TitaniumTM PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. 4.2 Mechanically Fastened Underlavments• 4.2.1 TitaniumTM' UDL-25 PLUS is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 Ibs/square. 4.2.2 TitaniumTM UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 Ibs/square. 4.2.3 Titanium' UDL-SO is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 Ibs/square. Exterior Research and Design, LLC. Evaluation Report I11980.11.08-112 Certificate of Authorization 59503 FL11602-R2 Revision 2: 02/17/2012 Page 2 of 6 S. C TRINITY' ERD 4.2.4 TitaniumT" UDL-TT is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 Ibs/square 4.2.5 TitaniumT" UDL-TF is a synthetic sheet -type underiayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 2.9 Ibs/square. 4.2.6 UDL-TTMC300 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 3.2 Ibs/square. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 TitaniumTm Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop TitaniumTm Roof Underlayments are follows: 5.4.1 5.5 5.5.1 5.5.2 Underlayment Tile Foam -On Tile Metal Wood Shakes & Shingles Slate PSU-30 s YesYes (See 5.4.1)UDL-25 Yes Yes PLUS s Mp No Yes Yes Yes UDL-30 No Yes Yes Yes UDL-50 No Yes Ys Yes UDL-TT No Yes Yes Yes UDL-TF No Yes Yes Yes 'UDL-T MC300 Yes Yes No Yes Yes Yes "Foam -On Tile" is limited to use of Polyfoam PolyPro AH160 or Dow Tile Bond applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Allowable substrates for PSU-30 are noted below: Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. Bond to Mechanically Attached Base Underlavment: ➢ ASTM D226, Type I or II felt. ➢ Titanium UDL-25 PLUS, UDL-30 (primed with D41 primer) or UDL-30 (inverted). 5.5.3 Wind Resistance for Underlavment Systems in Foam -On Tile Aoolications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. Exterior Research and Design,LLC. Evaluation Report I119SO.11.08-R2 Certificate of Authorization #9503 FL11602-112 Revision 2: 02/17/2012 Page 3 of 6 TRINITY ERD 5.5.3.1 Maximum Design Pressure = -45 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Titanium PSU-30, self -adhered 5.5.3.2 Maximum Design Pressure = -45 nsf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Titanium UDL-25 PLUS or UDL-30 (inverted), mechanically attached with FBC HVHZ ring shank nails and 1-5/8" diameter tin caps spaced 6-inch o.c. at 4- inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: Titanium PSU 30, self -adhered 5.5.3.3 Maximum Design Pressure = -45 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Titanium UDL-30 (printed side up), mechanically attached with FBC HVHZ ring shank nails and 1-5/8" diameter tin caps spaced 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: Titanium PSU 30, self -adhered 5.6 Exposure Limitations: 5.6.1 UDL-25 PLUS, UDL-30, UDL-SO, UDL-TT or UDL-TF shall not be left exposed for longer than 30-days. 5.6.2 PSU-30 shall not be left exposed for longer than 90-days. S.6.3 UDL-TTMC300 not be left exposed for longer than 180-days. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Table 2: Tile System Options per FRSA/TRI 07320/8-OS System Underlay Option Section Reference Roof Underlayment(s) 4 3.02D Two Ply No. 30 Double -layer, UDL 25, UDL 30, UDL 50, UDL TT, UDL System One: TF or UDL-TTMC300 Mechanically Fastened Tile, 5 3.02E Self -Adhered Underlayment PSU 30 Unsealed or Sealed Underlayment System No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL 6 3.02F Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) Top Layer: PSU 30 System Two: Mechanically Fastened Tile, 4 3.02D Self -Adhered Underlayment PSU 30 Sealed No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL Underlayment 5 3.02E Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) System Top Layer: PSU 30 System Four "A": 4 3.02D Self -Adhered PSU 30 Adhesive -Set Tile, Underlayment Unsealed or Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL System 5 3.02E Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) Top Layer: PSU 30 System Four"B": 3 3.02C Self -Adhered PSU 30 Adhesive -Set Tile, Underlayment Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL System 4 3.02D Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) Top Layer: PSU 30 Exterior Research and Design, LLC. Evaluation Report I11980.11.08-R2 Certificate of Authorization #9503 FL11602-R2 Revision 2: 02/17/2012 Page 4 of 6 TRINITY ( ERD 6. INSTALLATION: 6.1 Titanium Roof Underlayments shall be installed in accordance with Interwrap published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Titanium"" PSU-30: 6.3.1 PSU-30 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Cut to 10- to 15-foot manageable sections and re -roll with the release film side out. 6.3.3 Membrane Application: • Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. ➢ Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner. ➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches. If the membrane becomes misaligned, cut the roll and re -start. ➢ Upon completion, inspect the membrane and repair any defects or fish -mouths. 6.3.4 For use in tile applications• 6.3.4.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Section 5.7 herein, using the instructions noted above as a guideline 6.3.4.2 Wait a minimum of 24 hours prior to loading roof tiles. 6.3.4.3 Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. 6.4 TitaniumTM UDL-25 PLUS, UDL-30, UDL-50, UDL-TT, UDL-TF and (Private Labeled) UDL-TTMC300: 6.4.1 Install in compliance with manufacturer's published installation instructions and the requirements for ASTM D226, Type I and II underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Fasteners: 6.4.2.1 Mechanical attachment of UDL-25 PLUS and UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. 6.4.2.2 Mechanical attachment of UDL-50, UDL-TT, UDL-TF and (Private Labeled) UDL-TTMC300 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.4.3 Sloges of 4.12 or greater: 6.4.3.1 End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4- inches. Exterior Research and Design, LLC. Evaluation Report I11980.11.08-112 Certificate of Authorization #9503 FL11602-112 Revision 2: 02/17/2012 Page 5 of 6 )OTRINITY'ERD 6.4.3.2 Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4.4 Slopes of 2:12 to less than 4:12: 6.4.4.1 Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full - width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.4.3, but maintaining minimum 25-inch side (horizontal) laps, resulting in a double -layer application. 6.4.5 For use in tile aoolications: 6.4.5.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Section 5.7 herein. 6.4.5.2 TitaniumT1 UDL underlayments are 48-inches wide; wider than the typical, codified 36-inch wide ASTM D226, Type I and II underlayment. The placement and attachment requirements set forth in Sections 6.4.3 (single layer with PSU-30 overtop) and 6.4.4 (double -layer) are suitable to maintain the intent of FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, Systems 1 and 2. 6.4.5.3 Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA agency for information on production locations covered by F.A.C. Rule 9N-3 QA requirements. 10 QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc.-ETL/Warnock Hersey - QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report I11980.11.08-R2 Certificate of Authorization #9503 FL11602-112 Revision 2: 02/17/2012 Page 6 of 6