Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSALL APPLICABLE INFO MUST BE COMPLETED FO PLICATION TO BE ACCEPTED NED Date:4 flAq d By Permit Number: St. Lucie County Building Permit Application Planning and Development Services Building and Code Regulation Division 1300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: Roof ,. Address: 8344Muirfield Way, Port St. Lucie, FI.34986 Legal Description: 8344 Muirliield Way, Reserve Muirfield, Elk.,27, Lot 36, Port St. Lucie, FI. 34986 Property Tax ID #: 3328-802-0039-000-0 Lot No.36 Site Plan Name: Block No. 27 Project Name: John and Louise Meyers Setbacks Front. Back: Right Side: Left Side: WWWWr Repair three area's of roof leakaMtvalleys�.,0,1W f , �? Additional war war to e e o'rme un ert ispermrt—c ec a appy. 0HVAC �GasTank ❑Gas Piping _Shutters ❑Windows/Doors Electric O Plumbing Sprinklers Generator Roof Total Sq. Ft of Construction: 150 S Ft. of First Floor: Cost of Construction: $ 3700.00 Utilities :�Sewer Septic Building Height: 10, OWN Name John and Louise Meyers Name•. Louis Ragoaino Address:8344 Muirlield Way Company: Louie's Roofing City: Port St. Lucie State: Fl. Address: 5303 NW Almond Ave. Zip Code: 34986 Fax: City: Port St. Lucie State: Fl• Phone No. N/A Zip Code: 34986 Fax: E-Mail: Phone No. 772-359-4787 Fill in fee simple Title Holder on next page (if different E-Mail: louiesroofing@comcast.net from the Owner listed above) State or County License: CCC133D219 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUt'PLEM) NTAL -ONSTtR�U tx 10N tL f"3x .`vim %u . h•t ,"R" L EN LAUD INFOE2MATI0( , i.Y"� f i "ari , w __ .4 ' eAm h. i.. �Lk ..... .,.`-' je MORTGAGE COMPANY otApplicable DESIGNER/ENGINEER: otApplicabl Nam Nam _ Addres . Addre City: State: City: ate: Zip: one: Zip: Phone: FEE SIMPLE TITLE E _ Not Applicable BONDING COMPANY: Applicable Name Name: _Not Address: Address: City: City: Zip Phone: Zip Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recordine vour Notice of rnmmpnramant Signature of Owner/ Agent/ Lessee Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF Jr 6UCA7e COUNTY OF Br LurA t The fo �oing instrument was acknowledged before me The ng instrument was acknowledged before me this day of A)OdEH ('Sr t2 . 20 14 by this Vol71day of 00E H PEE. (2 .20_jq by Lf)U1,,)' JOHN Rra 6ozZIfJJ G.Od tg 30Hn3 9A600-ZWO (Name of person acknowledging) (Name of person acknowledging ) (Signature of of ublic- St—atFlorio (Signatu e f tary Public -State of Florida ) Personally Known OR Produced Identification Personally Known OR Produced Identifiication'l�- Type of Identification Prod ce FL I Q- 7 I'C, T pe of Identification Produced 1Fi I)pi0 .),Jr, Commission No. E C I "" "a;% (S }.fiIA GABRIELLA om ao ission No. 1 ea �o? y uw , Notar Public -State of FI rlda : «"° "�'''. MARIA GABRIELLA ZC0 �c My Comm. Ex ires Jun 23 015�.' ;°LE Nnhru Public - State Florlda �,,,o«yg",.•' Commission # EE 106030 y .a z My Comm. Expires Jun , 2015 Revised 07/15/2014 1110. ;;; Commission # EE 1 030 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS AFTER RECo rN-RELURN To. JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT SAINT LUCIE COUNTY FILE # 4013518 11/14/2014 at 11:36 AM. OR BOOK 3690 PAGE 496 - 496 Doc Type: NC RECORDING: $10.00 PERMrr NrMBER- NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 3328-802-0039-000-0 SUBDIVISION Reserve BLOCK 27 TRACTi LOT 36 BLDG UNIT 2. GENERAL DESCRHMON.OF IMPROVEMENT: Roof Repair 3.OWNER INFORMATION: a. Name John Meyers b. Address 8344 Muirfield Way Port Saint Lucie 34986 d. Name and address of fee simple titleholder (if other than i 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Louie's e2 - interest in property Owner 5303 NW Almond Ave PSL,FL 34986 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: N/A 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: N/A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: N/A S. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER; 9. Expiration date of notice of commencement (the expiration dam is 1 year from the date of recording unless a different date is specified) , 20 Print Name and Provide Signatory's Tide/Office State of County of The foregoing instnAmt was acknowledged before me this day of�( `20 Dy (Name of person) ) (Type of authority ... e.g. Owner, officer, trustee, attorney 'iu'fait7 For 0�0 ne of patty on behalf of whom instrument was executed) on y Known _L—�ur produced the followifig type of ID: f ct 9 OFFICIAL SEAL STELLA G. FULLAM ;i N(yI.IERSEY store of NotaryPublic) IScab Under pen ave read the foregoing and that the facts in it aze true to the best of-MA90W`ledge and t;c.� ' -,- belief (section 92.525, Florida Stamens Ir S1�r(s)' Authorized Officer/Director/Partner/Manager who signed above - Planning & Development Services. Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or772-462-2172 Fax:772-462-644.3 ROOF INSPECTION AFFIDAVIT Re: Permit# acm�/ 033 licensed as a( ontraeto /Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual cert fed under 468 F.S. to make such an inspection, On or about 51, „/ { I did personally inspect the roof deck nailing (Date) r�,� work at: 83tt (lob site address) Based upon that examination I have determined'the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most strigent). ' Signature and Seal STATE OF FLO,RRII.OA COUNTY OFjam( ttciF. C C c '?_? License # Sworn to and subscribed before me this (PP day of (1 1 2ojs by _ . . Who is personally known to me or who has produced OLDas Identification. Notary Public, State oorida Signature of Notary: Commission Number: En 01/19/2011 3 4 uuu .v SNANNON M. ANOREWS is' `4,Not s• = MY PutrRc- State of Florida My Comm- Expires Mar 6, 2616 �•, a.,..� CammlBafan # EF 169676 RECEIVED JAN 12 2015 CON. QED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBUY OF THE CONTP;CTOR OF PuCOP.D . COUNTY J BUILDING AND NEIGHBORHOOD COMPLIANCE BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF MIAMI-DADE COUNTY PRODUCT CONTROL SECTION rNC) 11805 SW 26 Street, Room 208 � Miami, Florida 33175-2474 590 F(786)315.2599 ST. I 1E COUNTY mm:AnAe.....1h-11A1n 1 Entegra Roof Tile, Inc. REVIEWED 1289 NE 91h Ave. FOR COMPI CE Okeechobee, FL.34972 REVIEWED BY DATE It, PI-019-ANCr PERMIT SCOPE: MUST BE KEPT ON JOB OR This NOA is being issued under the applicable rule NO LVMTARU traction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate ` s,, Tile LABELING: Each unit shall bear a permanent label withthe manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA ii I0-0518.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. rr C Y �W i�,� y (0 THESE PLA , AnDLRtPZ0SZED'WORK NOA No.11-0510.02 'nUNW ARE SUNEGT TO Rl� CO CTIONS Expiration Date: OS/23/16 t EC Approval Date:06130111 REONEU 6Y FIELD INSPECTORS THAT Page 1 of 6 MAY SE NECESak:RY IN 4"' OER TO COMPLY WIM ALL NIPUCAOI.S CODES, ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete I. SCOPE This approves a roofing system using Entegra Estate "S" Concrete Roof Tile, as manufactured by Entegra Roof Tile, Inc. in Okeechobee, FL. as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions SpeciPcatioris Description Entegra Estate `S' 1= 16-1/2" TAS 112 Low profile, interlocking, extruded concrete Roof Tile w = 13" roof tile equipped with two nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use w = varies at hips, rakes, ridges and valley varying thickness terminations. Manufactured for each the profile. 2.1 MANUFACTURING LOCATION 2.1.1. Okeechobee, FL. 2.2 EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Renort Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. I991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, 1994 PA 108 Aug. 1994 Professional Service 224-47099 PA 1 f= r co Industries, Inc. r�dr The Center for Applied 94-060B PA 1 i:�.� March, 1994 NOA No.11-0510.02 MUIMIMDE COUNTY Expiration Date: 08t23/16 Approval Date: 06/30/11 Page 2 of 6 Teat Ae _ Test Identifier Test Name/Renort Date Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-70944 PA 102 Oct. 1994 Project No.307025 PA 100 Oct. 1994 Test #MDC-76 25-7183-1 PA 102 Feb.1995 25-7183-2 PA 102 Feb.1995 25-7214-2 PA 102 March,1995 25-7214-6 PA 102 March, 1995 Celotex Corporation 528454-2-1 PA 101 Sep. 1998 Testing Services 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-264 TAS 112 01/08/08 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tle applications, a static field uplift test in accordance with TAS 'I06 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building and Neighborhood Compliance Department— Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No. 11-0510.02 M14MtDAnECOUNTY Explratlon Date: 08/23116 Approval Date: 06/30/11 Page 3 of 6 4. INSTALLATION 4.1 Entegra Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Entegra Estate's' Roof Tile 10.0 1.375 1 1.08 Table 2: Aerodynamic Multipliers -1, ( ) Tile Profile I (ft) I? Batten Application (f ) Direct Deck AppIfcation Entegra Estate'S' Roof Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - Ma (ft-lbf) Tile Profile 3":12" W' 12" 6":12" 6":12" Greater than 7":12" Entegra Estate 'S' Roof Tile Battens Direct I Deck Battens Direct I Deck Battens Direct Deck Battens Direct I Deck Battens Direct Deck 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Table 4: Attachment Resistance Expressed as a Moment - K (ft-lbf) for Nall -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min.19132" plywood) Battens Entegra 2-10d Ring Shank Nails 27.8 37.4 28.8 Estate'S' Roof Tile 1-10d Smooth or Screw Shank Naie 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screwz 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail Field Cli 2 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail CEave Cli s 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Five Cli 31.11 31.9 32.2 2-10d Ring Shank Nails 43.0 67.5 50.9 1 Installation with a 4" the headlap and fasteners are located a min. of 21/2" from head of tile. 2 When usina only one fastener use the hole that is approximatel 4.3/4" a Auu NOA No.11-0510.02 Expiration Date: 08/23/16 Approval Date: 06/30/11 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment Mr (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Ente ra Estate 'S' Roof Tile I Adhesive 26.1 3 See manufactures component approval for installation requirements. 4 Flexible Products Company TileBond Average weight per patty 11.4 grams. Pol osm Product Inc. Average weight car pagy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Estate 'S' Roof Tile Polyfoam PolyProTm 86.61 Poi am Pol ProTA° 45.5 5 l a e d iacement of 54 rams of Pci ProTw. 6 Medium ddv Placement of 24 grams of Poi ProTM. Table 7: Attachment Resistance Expressed as a Moment - Mr(ft-Ibf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Entegra Estate Mortar Set 20.60 'S' Roof Tile 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or fallowing statement: "Miami -Dade County Product Control Approved". L1� FAN =1111111111101 0 �j 11�1 PAN V�AMNEWIRW i, ME lm= N if I ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE 6. BUILDING PERMIT REQUIREMENTS: P0 � 1 1 C � co 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.11-0510.02 Expiration Date: OW23116 Approval Date: 06)30/11 Page 5 of 6 PROFILE DRAWING . Nail Holes --I--I ENTEGRA ESTATE "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE 9 NOA No.11-0510.02 Expiration Date: 08/P 16 Approval Date: 06/30/11 Page 6 of 6 ®.Ewz tx::�. /\� ��� � � \ � `^/\f2T� ��