Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: O ^� I ' SCANNED Permit Number: A— BY St. Lucie County Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Window/door PROPOSED hMPROUEMENT,L`OGATI'0`N F , { Address: 10044 S Ocean Dr Unit #304 Legal Description: 12 story building located on Florida cost line. Property Tax ID #: 4502-804-0020-000-7 Lot No. Site Plan Name: Project Name: Sea Winds Condominium Setbacks Front Back: _ Right Side: Left Side: Block No. Installation of 2 single hung windows, 1 picture window, 2 Mullions in master bedroom, Installation of 1 Sliding Glass Door in Living room. Installation of 2 single hung windows, 1 Mullions in 1st bedroom. Installation of 1 single hung windows in kitchen. PGT 700 series Wingard impact products. See Sea Winds Condominium shop drawings sheet 3 for more information. CONSTRUCTION INFOit, fi :.. t Adclitionai work to e nertormed under this permit — check all that apply: 0HVAC 0 Gas Tank ❑Gas Piping Shutters Q Windows/Doors _ 11 Electric El Plumbing Sprinklers Generator 11 Roof Total Sq. Ft of Construction: Cost of Construction: $ 1,700.00 Sq. Ft. of First Floor: _ Utilities: 0Sewer ❑Septic Building Height: OWNER/LESSEE Pruett CONTRACTOR:"Glass.Engineenng & Installation ,;lnc . Name James M & Carol L Pruett Name: Robert J Clark Address:10044 S Ocean Dr #304 Company: Glass Engineering & Installation, Inc. City: Jensen Beach State: FIL Address: 3677 23rd Avenue South - Unit A 101 Zip Code: 34957 Fax: n/a City: Lake Worth State: FL Phone No.317.797.4274 Zip Code: 33461 Fax: 772-673-2796 E-Mail: cjpruett2225@msn.com Phone No. 954-214-7672 Fill in fee simple Title Holder on next page (if different E-Mail: tcgei@bellsouth.net ' from the Owner listed above) State or County License: CGC011431 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: ` DESIGNER/ENGINEER: X Not Applicable MORTGAGE COMPANY: X_ Not Applicable Name: CW Engineering, I-I_C. Name: Address: 22693 Ashley Inn Terrace Address: City: Ashbum State: vA City: State: Zip: 20148 Phone: 703-726-1670 Zip: Phone: FEE SIMPLE TITLE HOLDER: x Not Applicable BONDING COMPANY: x Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording vour Notice of Commencement. nature of Owner/ Agent/ Lessee ature of Contrabtor/License Holder STATE OF FLORID ii STATE OF FLORIDA c COUNTY OF •_ l uci-e— COUNTY OF PRLnn IERCI.A The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this Q Q day of 0 C,h)hA_V 20 14 by this ILI day of Q CT,� Z 2014 by YA T,�NeOZA L (Name of person acknowled n Pa. P�B�,,, of person acknowledging) 1 ,Notary Public - State of FloMy Comm. Expires Aug 31, ( /1(/` "•' "' � , Commission # EE 1968 inj re /+ (� (Signature of Notary Public- Stafe' Personally Knowny POR Produced Identification Type of Identification Produced Commission No. EE I ot � y9- Z- (Seal) Revised 07/15/2014 re of Notary Public- State of Florida ) Personally Known _X OR Produced Identification Type of Identification Produced Commission No. LAURA A, GABRIEL J : ' "°' My Comm. Expires May 5, 201 Commission # FF 119538 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS Property Appraiser - St.Lucie County, FL Page 1 of 1 James M Pruett Record: 1 of i Property Identification Site Address: 10044 S OCEAN DR 304 Sec/Town/Range: 02 :375 :41 E Map ID: 45/02S Zoning: PROPERTY RECORD CARD <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print ParcellD: 4502-804-0020-000-7 t G2 Account # 122423 rn Use Type: Condo i Ci /Cn Saint Lucie County ri tY� Ownership and Mailing Legal Description Owner. James M Pruett Carol L Pruett SEA WINDS CONDOMINIUM APT 304 (OR 564-2994) Address: 10044 S Ocean Dr #304 Jensen Beach FL 34957 Sales Information Assessment 2013 Total Land and Building Date Price Code Deed Book/Page 2013 Final: 146000 Land Value: 0 Acres: 0.02 11/1/1987 96000 00 CV 0564 / 2994 Assessed: 143600 Building Value: 146000 3/1/1983 105000 OD CV 0398 / 2741 Ag.Credit: 0 Finished Area: 1197 SgFt Exempt: 50000 Taxable: 93600 Taxes: 2077.03 BUILDING INFORMATION Exterior Features View. 3900 - Ocean View RoofCover: - ExtType: X137 - SeaWndCondo YearBlt 1983 Grade: XSWC - SeaWindsC EffYrBft: 1983 StoryHght 0010-1 Story No.Units: 1 Interior Features RoofStruct: - Frame: - PrimeWall: BS - CS Stucco SecWall: - BedRooms: 2 Electric: - PrmintWall: - FullBath: 0 HeatType: - AvgHt/Fl: STD 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qua[. Cond. YrBlt No. Use Type Type Measure Depth 1 0400-Condo OF -Unit 0 0 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. 1.44_//--.._.-_..,,.,:I,. o/c/nni A Charles Williams PE 22693 Ashley Inn Terrace Ashburn, VA 20148 703 7261670 p Charlie@cw-engineering.net Salcedo Construction and Consulting Services, Inc. jms03&bellsouth.net Attn: Jorge M. Salcedo seal eA P %a WS q r-e wig r -A� t y ! ea�--o 3 63 R211/26/2014 Project: Sea Winds Condominium, i0044 South Ocean Dr., Hutchinson Island, FL Aluminum Sliding Glass Door and Window Replacement NOA No.13-0502.03, Series PW 701/720/820 Aluminum Fixed Window NOA No.11-1013.14, Series SH-700 Aluminum Single Hung Window NOA No.14-0213.10, Series SG-770 Aluminum Sliding Glass Door NOA No;11-0912.01, Series PGT Clipped Extruded Aluminum Mullion Manufacturer: PGT Industries, Inc., 1070 Technology Dr, Nokomis, FL 34275 References: Shop Drawings, 08.11.2014 .Design pressures (per ASCE 7-10), Components and Cladding: Speed =164 mph, Zone = 4, and 5 Building Height =106' Exposure- Importance Factor H Resulting design pressures are attached. FILE COPY Dear Jorge This letter is to confirm that all product applications, sizes and connections to substrate are within the scope of the NOA and, to the best of my knowledge meet the design requirements per Florida Building code. Regards, Charles Williams, PE (FL 50367) ST. LUCiE COUNTY MLIG DIVISION REVIEWED FOR CO LANCE REVIEWED BY DATE PLANS AND FERMIT MUST BE UP -TON JOB OR NO INSPECTION WILL BE MADE. V� •� ENsc"' •,?yam'; No. 50367 . STATE OF ; ��Z �0c-c�ORtpPN��:o °° �0NAL °°'Otis 0 a CO 'i Ar.,. ASCE 7-10 WIND LOAD CODE FOR BLDGS OVER 60 FEET HT, COMPONENTS.& CLADDING LOAD COMBINATIONS, CHAPTER 2, WORST CASE PG 8 WIND LOAD JOB : Sea Winds Condominium CUST.: Touchstone Consulting Group DATE 11.12.14 IN Design Pressures - ASD CONTROL #: INPUT 106 Building.Overail.11eight 25 Minimum Building Width,'W' C Exposure, 26.7.2 (BC or D) Pages 246,251 164 Basic Wiad:Spee . N) W.A. Fig: 26.5-IA,B,C Page 247-249, II Importance Factor Category CUM or IV), Table 1.5-1, PG 2 AO Importance Factor determines Wind Speed Table to use o W-M-d Bortic ens Zak t LEI v Y Impact Resistant Windows? (Y OR N) H Z 1.00 K2T, Topographical Factor,26,8.2, Fig 26.8, PG. 251.-254 0.85 KD, Dirctionaiity Factor Table 26.6-1, PG. 250 ASD Type ASD for Allowable Stress Design and LRFD for Strength Design Values in Output OUTPUT 0.18 G%; f ; Table 26.114, Page 258 .0.18 GCS; - , Table 26.11-1, Page 258 12.00 Tributary Area Definition; According to ASCE, TRIB AREA = (The Greater of or 1/3xff) 9.5 a, alpha, Table 26.9-1, page 256 900 Zg, Table 26.9-1, page 256 3.00 ' Zone Width 'a; (10% of least width [0:lox W], not less than 3.0 FT.) Velocity Pressure (ps1) Qh = 0:t10256*(VY'*Kh*K;*KD1 74.99 f. Equation 30.3-2, PG316 Exposure Coefficient Kh = 2.01 *(Z/Zd ` 1.28 Ref Table 30.3-1, PG 317 Design Pressure P = Qh*[(GCS-(GC,)] ' (See table Below) Ref. Equation 30.4-1, PG 318 GCp DESIGN PRESSURES GCp POSITIVE, >V1ID-ZONE GCp NEAR TRIB ZONES 4 & 5, NEGATIVE, AT CORNER ZONE POSITIVE ZONE MID -ZONE CORNER AREA FIG. 30.6-1, ZONE 4, NEGATIVE, PRESSURE NE. NEG. PG. 348 FIG. 30.6-1, PG. ZONE 5, 4 & 5 ZONE 4 ZONE 5 348 FIG. 30.6-1, PG. 348 PSF PSF PSF 10 0.90 -0.90 -1.80 48.6 -48.6 -89.1 20 0.90 -0.90 4.80 4&6 -48.6 -89.1 50 0.81 -0.84 -1.57 44.7 -46.0 -78.8 100 0.75 -0.80 -1.40 41.8 -44.1 -71.1 0.69 - -- --_.._...__-0.7_.G_- - ---=1,23------- -- 38.9 .. --"42.1 - ----63.3- - 500 0.60 -0.70 -1.00 35.1 -39.6 -53.1 Tributary Wind Pressure based on individual unit size 4 Typibal ftgr to floor height, (or window height] U 3 Typical mullion spacings, (or window width), 'S' 20 0.90 -0.90 -1.80 1 48.6 -48.6 f -89.1 NOTES: