Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFee Due: -t, Permit # x a �rE f MR ❑ Electrical ❑ Shed Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)162-1553 SCANNEE) BY St. Lucie County SPECIALTY PERMIT APPLICATION ❑ Plumbing OHVAC ❑ Fence ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional papenvork required for specialty permits 1. Location/Site Address: q loo n pip !- aa-), 2. Parcel ID Number. I y a,3 _ 50 D, - Section Tomnship Range Map Page I Zoning j Iand Use OP Initials A Only 01111 3. Complete Description of Project or Work: �,n fts 4. Owners Information 5. Contractors Information Name: f en -1 Cren; FL Reg/Cert #. Address: LjrQp n A City: 1Ex,1 Pled e State: ��'' F I �r_.7 Zip: �1-1Iy � Phone: 5 fJ-S 15L are 6. Value of Construction: S 01010 ---- County Cert#: Business Name: ,an� # C YnAnr► .Te7C, Phone: .39% age�l Fax: 3L{O q $O� OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating constru ' and zoning. �. PRINT OWNER OR CONT ACTOR NAME SIGNATURE F OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF __Ji . LWcJ_ ACKNOWLEDGED BEFORE ME THIS _ L3 DAY OF �% G�_. 20 % -�t . BY 1h a- rE__M-• MAnEf7 -L IS PERSONALLY KN0IY�LT�E OR WHO HAS PRODUCED AS IDENTIFICATION. SIGNATURE OF NOTARY COMMISSION NUMBER Notary Public Sttat6W 0*9 John Robert Mann My Commission EE 827605 Expires 08/16/2016 OF NOT (seal) NOTICE TO OWNER: FAIL IENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AIN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 WRIGHTSOFT Project:_ = jIl' marj/ o te: n archl!11,2m3 Gaoler By Design Entire House By: Shawn Russell Email: 2shavvnrussell@bellsDuth.net Project Information For. Brent Corrie, AC MANN 4100 N AIIA Bld 2 Unit 222, Fort Pierce, FL 34949 Email: 2shawnrussell@belis outh_ net Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing ructu 2-1-292—Btuh cture 4 7769—ERuh Ducts 4402 Btuh Ducts 9134 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25694 Btuh Use manufacturers data n Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftz) 169 1600 Volume (ft3) 14400 14400 Air changes/hour 0.50 0.26 Equiv. AVF (cfm) 120 62 Heating Equipment Summary Make Trade Model AHRI ref no. n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 25694 Btuh 21 OF 1113 cfm 0.043 cfm/Btuh 0 in H2O Rate/swing multiplier 0.95 Equipment sensible load 25558 Btuh Latent Cooling Equipment Load Sizing Structure 2607 Btuh Ducts 1897 Btuh Central vent (0 cfm) 0 Stuh Equipment latent load 4504 Btuh Equipment total load 30062 Btuh Req. total capacity at 0:70 SHR 3.0 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Cond GSX130361 B' Coil AWUF36XX168' AHRI ref no. 3513829 Efficiency 11.0 EER, 13 SEER Sensible cooling 23380 Btuh Latent cooling 10020 Btuh Total cooling 33400 Btuh Actual air flow 1113 cfm Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. O ht Wrl Sft 2W3-Mar-1116:1406 4!t 9 Right-SuiteO Universal 2012 12.0.04 RSLXM70 Page 1 'K'Chlk C:Wsers\Shawn Rusa11U]ocumerrtMALL WRIGHTSOFTINFO'GORRIE.fuP 031c= W8 Fiord Doorfaces: W 0 Certificate of Product Ratings AHRI Certified Reference Number: 3513829 Date: 3/11/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130361B* Indoor Unit Model Number: AWUF36XX16B* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240 2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 33400 EER Rating .(Cooling): _ .. _ 11-.00. . SEER Rating -(Cooling); 1.3.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) fisted on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectoryorg, it Air -Conditioning, Heating, dick on "Verify Certificate" fink and enter the AHRI Cued Reference Number and the date on �. 00 �/ and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. 02012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130075065756172526 rroperry Appraiser : 61.Lucie UOUnry, VL rage t0Ii Brent Corrie Record:1 of 1 Property tdontification Site Address: 4100 N A1A 222 Sec/rownlRange: 23 :34S :40E Map ID: 14/23N Zoning: Ownership and 1412iling PROPERTY'RECORD CARD «Prey Next >> Spec.Assmnt Taxes Exemptions Permits Hoare Print ParceliD. 1423-502-0011-000-3 Account# 8523 2 Use Type: Condo' City/Cnty St Lucie County CWner, Brent Corrie Address: 4100 N Highway A1A Unit 222 Fort Pierce FL 34949 Sales (nfdr.mation Date Price Code 9l2612012 159000 0112 5/172012, 100 0112 323/2011 100 70111 2/172007 570000_ 00 12142003 228500 00 S119r2ow 100 01 9M/1986 125000 00 4/1/1983 3556000 02 Legal Description TREASURE COVE DUNES UNIT 222 (OR 3446-27) .Assessinent2012 Deed BooklPage 2012 Final: 153100 SP 3446/0027 Assessed: 153100 CT 3392 / 2845 Ag.Credit 0 CT 3280 / 0219 Exempt WD 2789/2191 Taxable:: WD - 1864./0232 Taxes; 3097.42 CIC 157510052 CV 0516/0278 CV 0399 / 2833 BUILDING INFORMATION Total Land and Building Land Value; 0 Acres. 0.02 Building Value: 153100 Finished Area:. 1614 SgFt Exterior Peatures 0010 ViewC - RootCover - RoofStnrct - Base ExtType: X157-TresCvDune YearBir 1982 Frame: - Grade: XTCC - TreasureCov.0 EffYrSlt: 1982 PrimeWall: BS = CB Stucco Storftbt 0010 =1 story No.Units: 1 Se&Ml: - interior Features 9edROorrrs: 2 Electric: - PrinlrftlillaG: - Fulleatht 0 HeatType: - AvgHtf5l:. STD 1128ath' 0 HeatrueL Prm.Flors: - %AIC 0 %Heated: 0 '/oSpdnlded: Special Features and Yard Items Land information Type . Y/S City: Units Oual. Cond. YOL No- Use Type Type Measure Depth 1 0400-Condo OF =Unit 0 0 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT FT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=1423502001.10003 3/11/2013