HomeMy WebLinkAboutSUBMITTED PAPERSDate:
Fee Due:
Permit # I -'---)U
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
SCBNN�D
St LuG!@ c®Una
.Y
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbingelk
'HVAC ❑ Fence
❑ Shed ❑ Demolition / ❑ Gas ❑ Siding
See page 2 for im&uctmns and additional paperwork required for specialty permits
1. Location/Site Address: 3 2-61 Se- Ave— PV__
2. Parcel ID Number: 3 L/% &) - s-3 O O � 3 — 000 - / n
Office Use
Section
Township
Range
Map Page
Zoning
Land Use
Initials
Only
-
3. Complete Description of Project or Rork: (7.
4. Owners Information/ ))5. Contractors Information
Name: -m A t ,S GL t� e&L✓',h C FL Reg/Cert #:
Address: S b GA S At"�l ° a fklt- County Cert#: L
City: PU State: Business Name:
Zip: 3 Phone:772 2qq3`l� Phone: SG/ 370 aFas: �.a/ 333
6. Value -of Construction: $ ;,4 . `
OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating construction and zoning.
M C_kr'e- cl-_
PRINT OWNER OR CONTR NAME S119N9rURE OF OrqER QYCOTqTRWCTOR
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME.THIS DAY OF 20k �1 BY
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED
AS DN NTIFICATION.
`.••, AN,µ 4y4 '.
SIGNA OF NOTARY TYPE OR PRINT NAME OF NOTARY �: �a itp ICIO
MBER
COM JISSION NU�cpt"r8s �i�' 2 1t
T,,�,, �. CommissloWe`� bD'99a��6 ,
sitr� .. (lonAld TMou� National I�1 ,�
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR `-
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 --
Revised 04/26/2010
NOTICE TO OWNER: FAILURE TL _=CORD A NOTICE OF COMMENCEMENT M.A.'- -jESULT IN YOUR PAYING TWICE FOR
R%4PROVEMENTS TO YOUR PROPERTY IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -BEAT REPLACEMENT WITH CONTRACT UNDER $5,000.
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. The information to be provided with this application includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Owner Information
5. Contractor Information
Indicate the street address or general location of
property where the building activity is taking place.
Indicate the tax identification number of the
property where the building activity is taking place.
Fully describe the activity to take place.
Indicate the name and address of the owner of the
property on which activity is taking place.
Indicate the State of Florida registration number (if
applicable), St Lucie County contractor license
number and the name of the business doing the
work
f' work otake pla .
Total cost of construction includes all current retail
material and labor costs associated with the
building/construction activity. Construction value is
used to determine the permit fee. St. Lucie County
reserves the right to question and/or modify the
indicated value of construction if it is demonstrated
that the submitted figures are not consistent with
similar types of construction.
❑ Gas Attach 2 piping schematics with tank size,location, and BTU of each appliance
❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications
❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence
❑ Siding Attach 2 copies of manufactures specifications
HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for
new system or full replacement
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 PAL For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
NOTE. Emergency eledric service change out inspections will not be performed after 3: 00 PM without
special arrangements and additional fee paid.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
e
Sears Home Improvement Products Tanisha De La Haye
1024 Florida Central Parkway - Longwood, Florida 32750 320 SE GASPARILLA AVE
PORT ST LUCIE, FL 34983
Sales Consultant: Trevor Grosholz
Job#: 15171344 ff
Date: 03/09/2013 Ckoj'PY
System I (Average Load Procedure)
Design Conditions
Location: Fort Pierce, Florida Elevation: 25 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 27' N Design Grains: 64
Summer: 90 75 Heated Area 1659 Sq.Ft.
Winter: 42 70 Cooled Area 1659 Sq.Ft.
Heat/Loss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area Loss Gain Gain
Walls 1552 4626 3280 0
Windows 188 4579 12252 0
Doors 42 412 382 0
Skylights 0 0 0 0
Floors 191 5289 0 0
Room Internal Loads 0 3550 1000
Blower Load 1707 0 I
Hot Water Piping Load 0 0
Winter Humidification Load 0 0 0 i
Infiltration 2589 730 1925-_-__T____._
Approved ACCA
Ventilation 0 0 0 MJ8 Calculations
Duct Loss/Gain EHLF=0.119 ESGF=0.224 2292 5079 1104
AED Excursion n/a 1929 n/a
Subtotal 21552 31430 4029
Total Heating 21552 Btuh 7 kw of electric heat
Total Cooling 35459 Btuh 43 Linear ft. of Hydronic Baseboard
3.49 Nominal Tons of Sensible Cooling 2.95 Nominal Tons of Total Cooling
"Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed
calculations are estimates based on building use, weather data, and inputted values such as R-Values,
window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as
This application has glass areas that produce relatively large cooling loads for part of the day. Variable air
volume devices may be required to overcome spikes in solar load for one or more rooms. A zoned system
may be required, or some rooms may require zone control (provided by individual, motorized,
thermostatically controlled dampers).
Adtek Accul-oad Report Version 3.1.3 Page 1
a
Sears Home Improvement Products Tanisha De La Haye
1024 Florida Central Parkway - Longwood, Florida 32750 320 SE GASPARILLA AVE
PORT ST LUCIE, FL 34983
Sales Consultant: Trevor Grosholz
Job#: 15171344
Date: 03/09/2013
System I Load Chart
Heat Loss Percentages ■ Walls
11% Windows & Skylights
21% Doors
% 12
Ceilings
Floors
Misc System Loss
21% Infiltration
25% ® Ventilation
80/0 2% Duct Loss
Heat Gain Percentages Walls
10% Windows & Skylights
19%
Doors
A` Ceilings
8% Floors
Internal Gains
39%
Infiltration
14% Ventilation
s% 1% ® Duct Loss
Adtek AccuLoad Report Version 3.1.3 Page 2
4 _
i
Sears Home Improvement Products Tanisha De La Haye
1024 Florida Central Parkway - Longwood, Florida 32750 320 SE GASPARILLA AVE
PORT ST LUCIE, FL 34983
Sales Consultant: Trevor Grosholz
Job#: 15171344
Date: 03/09/2013
— AED Curve — DAL
18000
16000
14000
12000
= 10000
3
8000
System /
— 1.3 — 1.5
6000
4000
2000
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour
AED Excursion: 1929 btuh
AED Status: System does NOT have Adequate Exposure Diversity_
AED Flag: This application has glass areas that produce relatively large cooling loads for part of the day. Variable air
volume devices may be required to overcome spikes in solar load for one or more rooms. A zoned system
may be required, or some rooms may require zone control (provided by individual, motorized, thermostatically
controlled dampers).
Hours are listed in 24-hour format: 8 is 8am, 20 is 8pm.
Adtek Accul-oad Report Version 3.1.3 Page 3
Sears Home Improvement Products Tanisha De La Haye
1024 Florida Central Parkway - Longwood, Florida 32750 320 SE GASPARILLA AVE
PORT ST LUCIE, FL 34983
Sales Consultant: Trevor Groshoiz
Job#: 15171344
Date: 03/09/2013
System 1 Breakdown
Item Name U-Value Net Area Htg. HTM. Clg. HTM Sens. Htg. Sens. Clg. Lat. Cig. Total Clg.
Construction TVDe
System I 0 1707 0 1707
Room C 0 0
Ceiling
0.038 120 1.064 1.52 128 182 0 182
Ceiling under FHA Vented Attic or Attic Knee Wall, No Radiant BarrierlAsphalt ShingleslLight Coli
Floor
0.989 34 27.692 0 941 0 _ 0 0
Concrete Slab -On -Grade FloorINAIPassivelNo InsulationlNo Insulation INA]NAILight Dry
...... _... _........... ._....__..........._......_................ _............._.............._.....
East Wall
---- ............ _.._........ _..... - - ---...-.....__..... _..... _................. _..--........ ......_....._.._...__...._._.._..........._._...._..__..__._._...._........._.._....._..........._...................... _...................... .......... _._............ _.................. ...._................. ............................ ..............:..._
0.125 75 3.5 7.91 262 593 0 593
Block Wall/PartitionlNAINAINone/With Interior Finish INonel R-51 Open I Siding or StuccolNA
^ Door-3x7
0.35 21 9.8 9.1 206 191 0 191
Metal I Polystyrene CorelNo Storm
North Wall
0.125 80 3.5 1.91 280 153 0 153
Block Wall/PartitionINAINAINone/With Interior Finish INonel R-51 Open I Siding or StuccolNA
West Wall
0.125 84 3.5 1.9 294 160
0
160
Block Wall/PartitionINAINAINone/With Interior Finish [None[ R-51 Open I Siding or StuccoINA
Window-2x3
0.87 6 24.36 66.33 - 146-- - 398
- 0 - -
-398
OperablejNormal WindowlClearll Pane (w/storm)jMetal No Break
Window-2x3
0.87 6 24.36 66.33 146 398
0
398
OperablelNormal WindowIClearll Pane (w/storm)[Metal No Break
_
Room A
0 3550
1000
4550
._..... _.... __............ _..... _........ ..._.._..... --............................. _..._._.._..
Ceiling
--.._._._..--........ _.... ---.............. -._...._._.__------------ ---..._......_.._.-..... -.... ................... _....... _... --... .... ---..... _........ ..... _..... .................. _.......... _.._.... _... __............... _..... _.................... ....._....._......._...__....... _........ _.
0.038 1302 1.064 1.52 1385 1979 0 1979
Ceiling under FHA Vented Attic or Attic Knee Wall, No Radiant BarrierlAsphalt Shinglesl Light Coli
Floor
0.989 98 27.692 0 2714 0 0 0
Concrete Slab -On -Grade Floor] NAlPassivelNo InsulationlNo InsulationlNAINAILight Dry
West Wall
0.125 130 3.5 1.91 455 248 0 248
Block Wall/PartitionlNAINAINone/With Interior Finish I Nonel R-51 Open I Siding or StuccoINA
----------...---- ---�-
Window-2x3
- --- -- --...._..__......--
0.87 6 24.36 66.33 146 . 398 0 398
OperablelNormal WindowIClearll Pane (w/storm)IMetal No Break
Window-6x4
0.87 24 24.36 69.13 585 1659 0 1659
OperablelNormal WindowlClearll Pane (w/storm)�Metal No Break
.... _......_..._...... _..._......................_...._.........................................
East Wall
... __............._.........---.._........._...._............... --......_............_.._........----..._.._..._...-...._...._..............:......_._......_._.:.._......__............... .... _....... _.............. ............... ............ .......... _........................ --................... ..................................... ......
0.125 167 3.5 1.91 584 319 0 319
Block Wall/PartitionlNAINAINone/With Interior Finish lNonelR-51Open ISiding or StuccolNA
_ Door-3x7
0.35 21 9.8 9.1 206 191 0 191
MetalIPolystyrene CorejNo Storm
---- ... -.... -- - ---------- --- - --- - - -----....- ......_..-._._.._......_._.._........_._...
Window-5x4 0.87 20 24.36 69.1 487 1382 0 1382
OperablejNormal WindowlClearll Pane (w/storm)IMetal No Break
.__._.......
--
Window-6x4 0.87 24 24.36 69.13 585 1659 0 1659
OperablejNormal WindowIClearll Pane (w/storm)lMetal No Break
.r-t----._........._._.-..._....._._.._........__........_...- ----..._...-..._........_... -.._......----..__..__...............- - -.._........_.....__..........._.._..._.__._..-.....---..-..._.._.._....__............_........._..._..... ---.........._...-------......._.._._................._.._...._....._...:.._
North Wall 0.125 168 3.5 0.99 588 166 0 166
Block Wall/PartitioniNAINAINone/With Interior Finish INonelR-5lOpenlSiding or StuccoINA
Adtek Accul-oad Report Version 3.1.3 Page 4
1
Sears Home Improvement Products Tanisha De La Haye ,
1024 Florida Central Parkway - Longwood, Florida 32750 320 SE GASPARILLA AVE
- PORT ST LUCIE, FL 34983
Sales Consultant: Trevor Grosholz
Job#: 15171344
Date: 03/09/2013
South Wall 0.125 248 3.5 1.91 868 474 0 474
Block Wall/PartitionINAINAINone/With Interior FinishINoneIR-510penISiding or Stucco]NA
Room B 0 0 0 0
_..... _............ ............ ......... .... _.... --....__..__._._..._....
Ceiling
.._.._._._....__........__._... _ ----- ...-...._..--...._.._._.__.- --..._..--- .._....---...._ - ----- __- --._.............. _....................... ----- ............. _...__......
0.038 198 1.064 1.52 211 301 0 301
Ceiling under FHA Vented Attic or Attic Knee Wall, No Radiant BarrierjAsphalt Shinglesl Light Col,
........... ............... _._...._._........----
00r
. ......... -- ..._._..._..._...---...........- ---._.._.._..---...__...- .._.__.... __..._ ... --_.._.__......._........._...._.._.._............__..._...._._._....._......_.._..................__._...
0.989 40 27.692 0 1108 0 0 0
Concrete Slab -On -Grade Floor�NAIPassivelNo InsulationlNo InsulationINAINAILight Dry
........... _... ......_.... ...... - .... - - ---..._....__.._..
South Wall
- - -- .--......-_.._.._...._...._...._.........._.._.._....__..__...__.-.._._...__..._......._......_..--- - - ... __..._......_._.... --............._........_..__.._.._.. ...........
0.125 72 3.5 1.92 252 138 0 138
Block Wall/PartitionINAINAINone/With Interior Finish I Nonel R-51 Open I Siding or StuccoINA
North Wall -
0.125 52 3.5 1.9 182 99 0 99
Block Wall/PartitionINAINAINone/With Interior Finish I Nonel R-51 Open I Siding or Stucco]NA
-
................. --....... _... -..... ............... _............. _ ..... _..__.._...._..._..__...--
Window-5x4
.... - ------ - ._...--.......- ...._.__........._._...-- - -- _.._.. ---- -- --._.._...__._._._.-_......._.._............_...--- .._.__..._._.__..._._..._...._
0.87 20 24.36 27-1 487 542 0 542
OperableiNormal WindowIClearii Pane (w/storm)lMetal No Break
._..... _........ _.......... _ .. _.._.._ ............._._....._._....-
West Wall
0.125 114 3.5 1.91 399 218 0 218
Block WaIVPartitioniNAINAINone/With Interior Finish INonelR-51OpenjSiding or StuccoINA
_-- ---._....
._.... _...... ---- -- ----- -
Window-5x4
- --- _ _ _--- --- -- ---- __ ---------- --- -- --- — -- --- _- - ..._..._.__.
0.87 20 24-36 69.1 487 1382 0 1382
w orm e a o rea
Window-6x7
0.87 42 24-36 72.67 1023 3052 0 3052
_-...-.....
OperablelNormal Window�Clearli Pane (w/storm)lMetal No Break
---- --- -- - -- - -- --------..__..__......---....._....
-- -..... -.._.._.....................
Room D
------------- ..__._._.._..- --.._..-
0 0 0 0
ng 0.038 39 1.064 1.51 41 59 0 59
Ceiling under FHA Vented Attic or Attic Knee Wall, No Radiant BarrierjAsphalt ShingleslLight Coli
Floor
0.989 19 27.692 0 526 0 0 0
Concrete Slab -On -Grade FloorlN_AIPassivelNo_ InsulationlNo Insulation INAINA] Light Dry
East Wall
0.125 84 3.5 - 7.9 — 294 664 0 664
Block Wall/PartitionINAINAINone/With Interior FinishINoneIR-510penISiding or StuccojNA
._.... _....._........... ........_._...._......_.._._-----..__..._.__..._.__............---.._.._..__.....------..__.._..__...__._.I._..__.....
Window-5x4
0.87 20 24.36 69.1 487 1382 0 1382
OperableiNormal Window[Clearii Pane (w/storm)lMetal No Break
— -North Wall
0.125 24 — 3.5 -- ---- 1 --- - 84 -- 24 0 24
Block Wall/PartitionINAINAINone/With Interior Finish INoneIR-51Open[Siding or StuccoINA
South Wall
0.125 24 3.5 1 84 24 0 24
Block Wall/PartitionINAINAINone/With Interior FinishiNoneIR-51 Openj Siding or Stucco[NA
Adtek Accul-oad Report Version 3.1.3 Page 5
Sears Home Improvement Products
1024 Florida Central Parkway - Longwood, Florida 32750
Sales Consultant:
Job#:
Date:
Trevor Grosholz
15171344
03/09/2013
Tanisha De La Haye
320 SE GASPARILLA AVE
PORT ST LUCIE, FL 34983
System I CFM
Duct sizes and velocities based on settings selected in the setup screen.
`Duct sizes calculated using this CFM.
Winter Summer
Winter
Summer
Return
Supply
Calculated Calculated
System
System
Item Name
Velocity
RA Duct Size Velocity. SA Duct Size
CFM CFM
GFM
CFM
System 1
0
0
392 1341
0
.0
__........._.......... ... ...... ..__....... .._._..............._......_.._..
Room C
--._....._.. ....
0
- ....... - ... ....... ..... -... ... -- -—......... ..... ._... ._...... _...__..... ........ .. _
0
._......... _..... _........ .._.._.............
57 129
_._......__..__....__..---..__
0
........ ._.... _._.....
.0
Room A
0.... .:....
.... 0
205 734 ..
0
* 0
Room B ..
0
_.... 0 _
99... 351
_0.. _ ......
_. .*_0
Room D ........ _ _...... _
0
_... .. .._ . 0... _.._..._ . _ ..... ... .... . ....
...........
... 31_ ..__ 127
0
*. O ........
Adtek Accul-oad Report Version 3.1.3 Page 6
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2013.
. . ........
AHRI Certified Reference Number: 4068618 Date: 3/11/2013
Product: Split System: Air -Cooled Condensing unit, Coil with Blower
Outdoor Unit Model Number: TXA636GKA*
Indoor Emit Model Number: FXWX36"A*
Manufacturer: TEMPSTAR
TradeiBrand name: SMARTCOMFORT TX 5600 R410A AC '
Manufacturer responsible for the rating of this syst in n iCT S
Rated as follows in accordance with AHRI Standard 10 - 8 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 34200
SEER Rating (Cooling): 16.00
Ratings followed by an asterisk r) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates aninvolurdary rerate.
DISCLAIMER
AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of arty kindarising out ofthe use or performance of the product(s), or the
unauthorized alteration of data fisted on tits Certificate. Certified ratings are valid only for.models and configurations listed in the directory at wwwaitridirectoryorg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidentiall reference purposes.
The contents of this Certificate may not, in whole or in part, be reproduced; copied: disseminated; entered Into a computer database; or otherwise utilized, in any
form or mariner or by any means, except for the user's individual, personal and confidential reference_
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at wmv ehddiroctoryorg, "ImpAir-GOn�)tOnitt , Heating,
on "Verify Certlflca*n" link and enter the AHRI Certified Reference Number and the date on IR® Ike and Refrigeration Institute
which the certificate was issued, which is listed above, and the Certifiicate No., which is listed below.
OO 2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130074852090184295