HomeMy WebLinkAboutSUBMITTED PAPERSf
DATE:
LA PERMIT NUM'
S I J PLANNING & DEVELOPMENT SERVICES DEPARTMENT,
BUILDING & CODE REGULATIONS DIVISION
SCANNED 2300 Virginia Avenue
BY Fort Pierce, FL 34982 3 co
--_.______._._._.._._..._._.._ ....... __.___.._........__i St. Lucie County (772) 462-1553 6, C)
APPLICATION FOR REPLACEMENT OF s
WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS
1. LOCATION/SITE ADDRESS: 5,3 O`:a, tA U 1N\- tM'I k)!¢
�0 0�
2. PARCEL ID NUMBER:
3. DESCRIPTION OF PROJECT OR WORK ACTIVITY:
4. TYPE OF STRUCTURE: SFR MOBILE HOME OTHER
5. OWNERS INFORMATION \ 6. CONTRACTOR'S INFORMATION
Name A I ICE nn L.t�YV j FL Reg/Cert #:
Address: � o A u nn a r Aim b 1 Mf �{,�, County Cert #:-
City: RnsnPcclVa-mee::7�-- r
Zip:3 Lt —) ahone: Phone Number:
Windows, Swing Doors,
Skylights, Fixed Glass
Opening Design Pressure
A.S.C.E - 7
Design
Pressure
Product
Manufacture
Model #
Method of Attachment #
Florida Product Approval #
120 mph
1130 mph
1140 mph
Windows & Skylights
�5v S
�i tef's�c.�i
Sal(
VN I�� Wci.
Exposure B
Exposure C
Overhead Garage Doors
< 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2)
B- Size
C- Size
7. VALUE OF CONSTRUCTION: $ Sa
FEES DUE:
RECEIPT:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application,i$ correct and that all work will be done in
`compliance with all applicable laws regulating construction and zo
�1ni�Ig.
ames -D-e�—
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS DAY OF , 20131 BX )Q Me5b•-WV( WHO IS PERSONALLY KNOWN TO ME OR WHO
HAS PRODUCED AS IDENTIFICATION. ANGELA YOUNG
4rno In YP
/ ou�'e MY COMMISSION # EE188835
SWTO-gOFYNO ARY T P R PRINT NAM O - EXPIRES Aptil 92,201E
. ....TITLE: NOTARLIC COMMISSION NUMBER (40�398 D793 FlorldaNWsrySorvtee.oDm .
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
0
Phone: 772) 489-3688
Salesp rson: DD6010
Review r:
Near_
Hare Phone
BUEBENDORF ETHEL
(347) 200-8738
`
Address 5396ARTHURKILLRD Work PMre
(347)200-8738
Goff vewmv Nem
cry STATEN ISLAND JobLvascrpftm
DOOR INSTALL2f13
State NY Zp 10307 0O61ty RICH
OND
Page 1 of 5 No. 0283-237738
QUOTE
2013-02-1314:17
Prices Valid Thru: 02MOM13
R: EC:111� 1( I MERCHANDISE AMID SERVICE SUMMARY Woe `ieuv{orners limitthequantltiesofinerchandise
REF # 101
n
STOCK MERCHANDISE l
Nr
R04 0000-425-125
a
S/O - MDSE TO BE DELIV
co
ti
ti
S0201
1 0000-639-016
KS SEC TYLO SGt CYL C
DESCRIPTION .'
1.00 EA NA / <> 38 112" K 801/4" - D, R O. / {#1}<>
161!!BQIQAPRODUCTCATEGO Y=ENTRYDOOI
LD-WENWINDOWSDOORS-
DOORSYSTEMS,QALOCATiO=KISSIMMEE(FI
BER=1.800.246.9131,QAPROD CTTYPE=ENTF
! S0202 1 0000-639-01 s 1 1.001 EA
M
S0203 1 0000-639-016 1.00 1 EA
LL
r_IENDOR - SPECIAL INSTRUCTIONS: 12.2
O
a DELIVERY INFORMATION: DELIVERY DA
000
N
OLn
o
O
N
O
Page 1 of 5 NO. 0283-237738
(V
/*ATT
r Copy
ESTIMATED ARRIVAL D
A:. N
IS,QAMANUF J E
PHONENUM
AMATERIAL=ST
RSLABS,QAPRODUC
ADDER: A 1 N
$260,591 $260.59
7.51
co
I
10
CL
A
A
0
ti
0%
co
ti
ti
ti
0
a
PM
00
N
O
QUOTE - Continued
Last �ame: BUEBENDORF
Page 2 of 5 No. 0283-237738
::; {Co�uiij`•: :REF
#101
INSTALLER WILL DELIVER MDSE TO: SITE OF INSTALLATION #101 At
TIME OF INSTALLATION.
NOTE: UPON, RECEIPT OF ALL S/O MERCHANDISE -INSTALLER WILL
DATE.
ALL CUSTOMER TO SCHEDULE INSTALL
-RE F # I[I 1
''MERCHANDISE
TO BE INSTALLED:
R04
�
-t#M
;.::::€:€.:•:::. ::`;==€'
N)ESORIPTION ..:•.'::::°::=
:::-.-"=`:':°::
0000-425-125
1.00
EA
KS SEC TYLO SGL CYL COM
O ANT BRASS
S0201
0000-639-016
1.00
EA
<> 38112" X 80114' - D R.Q.
S0202
0000-639-016
1.00
EA
SCREEN
S0203
0000-639-016
1.00
EA
.IAMB
BASIC INSTALLATION
LABOR:
`::DESCRIPTION ::;:::':-'`-,.
:::-° €:;.:
:. ....::::.
=:::i2TY
lJM-
TAX
°.F:.:.fiiGE EACI�i'°
EXTENSION:.
0000-523
-672
EXTERIOR DOOR FL-NATIPRE-HUNG DOOR UP TO 36X96
1.00
EA
N
$287.00
$287.00
OPTIONAL LABOR SELECTED INCLUDES:
°:QFFION
'::°? -:: :. °: .:.-. ,DESCRIPTION
11M.:.: 'i,4X
°°E?FitCE EACH
.EXTENSION:::
1
HAUL AWAY OF EXISTING DOOR PER DOOR OPENIN
$15.00
CUSTOM LABOR SELECTED INCLUDES:
=QPfiNON"
°:. =:::: DESCRIPTION
°__``::::;: `°`;: - -=
=:.QTY--
- UM
T'AX
: PF3lCE:EACH
EXTENSION
1
IREBUCK DOOR OPENING
1_00
MR
N
0.00
$60.00
'NS7A LATihWsITE NAMt j BUEBENDORF ETHEL
INSTALL LABOR CHARGE:
352.00
_ DDRESS: 6303 hummingbird way
TRIP CHARGE:
$0.00
^CITY. FORT PIERCE STATE: FL
ZIP: 34951
CREDIT FOR DEPOSITIMEASURE:
50.00
COUNTY: SAINT LUCIE SALES TAX RATE: 6.500 TAX: Merchandise
- N LABOR - N
•
5302.Go
PHONE: 347 200-8738 ALTERNATE PHONE:
7 200-8738
N Page 2 of 5
No. 0283-237738
Copy
co
ti
a
O
A
A
0
ti
a
co
(V
ti
f`
cn
w
aK
0
a
M
co
ctl
O
H
09
Y�1
QUOTE - Continued
Last N me: BUEBENDORF
Page 4 of 5 No. 0283-237738
REF #101
{Eontiiiues.':::
PARTS OF THE HOME 1S A NATURAL OCCURRENCE AND IS THE
'CANCELLING APPOINTMENTS WITH INSTALLERS OR MISSING
RESPONSIBILITY OF THE CUSTOMER.
SCHEDULED APPOINTMENTS MAY LEAD TO ADDITIONAL CHARGES
'AN ADULT OVER 18 YEARS OF AGE WITH THE AUTHORITY TO MAKE
' REFER TO PRODUCT MANUAL FOR SPECIFIC WARRANTY AND
DECISIONS ABOUT YOUR INSTALLATION MUST BE PRESENT DURING THE
MAINTENANCE INFORMATION.
INSPECTION (WHEN APPLICABLE), DELIVERY AND INSTALLATION
' THE INSTALLER MAY DECLINE TO INSTALL THE JOB IFIN THEIR
'ALL BREAKABLES ANDIOR VALUABLE OBJECTS MUST BE REMOVED
PROFESSIONAL OPINION IT SEEMS UNSAFE, IN VIOLATION OF STATE
FROM TH E WORK AREA PRIOR TO INSTALLATION
OR LOCAL CODES OR CANNOT BE PERFORMED TO INDUSTRY STANDARDS
" CHILDREN AND PETS MUST BE KEPT AWAY FROM THE WORK AREA
REF # 106
ESTIMATED INSTALL BEGIN
DATE: 03M3/2013 ESTIMATED INSTALL END DATE: 03/1312013
BASIC INSTALLATION LABOR:
=:. DESCRtPTJUN
- "TAk PRICE::EACf'1' c Xl`ENSION .
0000-114 BUILDING MATERIALS PERMIT FEE -NAT/
1.00 EA N $0.01 $0.01
-442
OPTIONAL LABOR SELECTED INCLUDES:
° `.
Q71' :.:- TA3C ' PRIG EACH::::- EXTEIySION
` DESCRIP710N ::
:€::. - ..:°
.<°;l_llsil:`-`:;:;:
5 PERM17 AND ADMINISTRATIVE FEE CITY X $1.00 I
180.00 EA N $1,00 $180,00
'f §TALEAT10N-STENAME l BUEBENDORF, ETHEL
INSTALL LABOR CHARGE: $180.01
ADDRESS: 5303 hummingbird way
TRIP CHARGE: $0.00
.CITY: FORT PIERCE STATE: FL
ZIP: 34951
CREDIT FOR DEPOSITIMEASURE: $0.00
OUNTY: SAINT LUCIE SALES TAX RATE: 6.500 TAX: Mero
andise - N LABOR - N
0 .15 0$i80.01
PHONE: 347 200-8738 ALTERNATE PHONE:
7 200-8738
13ASIC INSTALLATION
LABOR INCLUDES:
' ALL FEES ASSOCI ATED WITH OBTAINING PERMIT (MUNICIPALITY
OR INSTALLER. IF DELIVERED TO INSTALLER, THE INSTALLER WILL
FEES, ENGINEERING. WIND LOAD CALCULATIONS, RECORDING
ARRIVE AT JOBSITE ON DAY OF INSTALL AND LEAVE WITH CUSTOMER.
:— CONTINUED ON71VE?GT: PAGE-"'
Page 4 of 5
No. 0283-237738
Copy
Co
O
r
A
A
-41
a
co
[V
ti
ti
u
u
0
n.
00
Cm
0
QUOTE - Continued
A
Last ame: BUEBENDORF
Page 5 of 5 No. 0283-237738
; --'- NSTALLATION :42--
Oornin
'{uepj:• -, -
REF #106
POSTAGE AND ADMINISTRATIVE).
DELIVER COMPLETED PERMIT PACKAGE TO PROPER MUNICIPALITY.
PICK UP FROM THAT MUNICIPALITY AND DELIVER TO EITHER JOBSITE
PECIAL NOTES:
'CUSTOMER IS RESPONSIBLE FOR PAYMENT OF THE PERMIT_ ONCE
IN FULL. NO REFUNDS ON PERMIT FEES AFTER 72 HRS. OF PAYMENT.
THE PERMIT IS PAID FOR. WORK ON THE PERMIT ASSEMBLY BEGINS
NMEDIATELY. CANCELLATIONS WITHIN 72 HRS. WILL BE REFUNDED
flF=[ALIT:..:..
:.:.:
TOTAL CHARGES OF ALL MERCHANDISE & SE
VICES
Policy Id (PI):
A: 90 DAYS DEFAULT POLICY--
SALES TAX
$0.00
TOTAL
769.52
BALANCE DUE
$769.521
'The Home Depot reserves the dgh t to fira t I deny realms. Please seethe
turn policy sign in
stores for details.'
ENDOF
RDER No. 02i3::
N Page 5 of 5
No. 0283-237738
stonier Copy
36" X 80"
REPLACE DOOR IN 1 OPENING ONLY.
HURRICANE SHUTTERS NOT REQUIRED.
-LE Copy,"r-
--0
OPENING
PRODUCT
DESIGN
OPENING
SQ.
I
WIND
I
PRESSURES
APPROVAL
PRESSURES
I
COMMENTS
NO. WDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 36 80
20.00
1 4
36.1 -39.3
FL14111.2
1 50.0 1 -50.0
LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 11 FT 4 IN
BUEBENDORF RESIDENCE
5303 HUMMINGBIRD WAY
FORT PIERCE, FLORIDA
DOOR REPLACEMENT PLAN
04109/2012 -
FA01 Proiect Files\ 2010-MPS\400 Wind
Series C&C
2010 FLORIDA BUILDING CODE & ASCE 7-10 " .SD"
DESIGN LOADS FOR COMPONENTS AND CLADANG
INTERIOR ZONE 4 PRESSURES
Mean
DESIGN PRESSURES (PSF)- ZONE 4
Roof
Tributary Area JS Ft �.
15 20 • 25 30 •�-4 '�45Z,
1.0-40.0
-39.3
-38.7
-38.3
-3 F9+37.8
+36.8
+36.1
+35.5
+35.1
+ 4,7
4m
c+�q4
3:
re10
-41.6
-40.5
-39.3
-38 8
3 4�
all
frT'-
+38.3
+37.3
+36.6
+36.0
+35 6
+ 2
-+ 9
i+34 6.N343'-42.1
-41.1
-40.3
-39.8
-39.3
38'9'
8�
;383.
`f3
+38.8
+37.8
+37.1
+36.5
+36.0
+35.6
+3 3
+"3@)Q
^t34.7
18ft
-42.6
-41.6
-40.8
-40.3
-39.8
�9��^
9nt3ry8-8
I I
,��85=
+39.3
+38.2
+37.5
+36.9
+36.5
'w36.
+3535'2
-43.1
-42.0
-41.3
AO.7
-40.3
-392:
;�9; f5,�
9
mp
19 ft
+39.7
+38.7
+37.9
+37.4
+36.9
+36.5
+36.1
+35.8
+35.6
20 ft
-43.6
-42.5
-41.7
-41.2
-40.7
-40.3
-39.9
-39.6
-39.4
+40.2
+39.1
+38.3
+37.8
+37.3
+36.9
+36.5
+36.2
+36.0
21 ft
-44.0
-42.9
-42.2
-41.6
-41.1
-40.7
-40.4
-40.0
-39.8
+40.6
+39.5
+38.7
+38.2
+37.7
+37.3
+36.9
+36.6
+36.3
22 ft
-44.4
-43.4
-42.6
-42.0
-41.5
-41.1
-40.7
-40.4
-40.2
+41.0
+39.9
+39.1
+38.5
+38.0
+37.6
+37.3
+37.0
+36.7
23 ft
-44.9
-43.8
-43.0
-42.4
-41.9
-41.5
-41.1
-40.8
-40.5
+41.4
+40.3
+39.5
+38.9
+38.4
+38.0
+37.6
1 +37.3
+37.0
24 ft
-45.3
-44.2
-43.4
-42.8
-42.3
-41.9
-41.5
-41.2
-40.9
+41.7
+40.6
+39.8
+39.2
+38.7
+38.3
+38.0
+37.6
+37.4
25 ft
-45.7
-44.5
-43.8
-43.1
-42.6
-42.2
-41.9
-41.5
-41.3
+42.1
+41.0
+40.2
+39.6
+39.1
+38.7
+38.3
+38.0
+37.7
26 ft
46.0
-44.9
-44.1
-43.5
-43.0
-42.6
-42.2
-41.9
-41.6
+42.4
+41.3
+40.5
+39.9
+39.4
+39.0
+38.6
+38.3
+38.0
27 ft
-46.4
-45.3
-44.5
-43.9
-43.3
-42.9
-42.5
-42.2
-41.9
+42.8
+41.6
+40.8
+40.2
+39.7
+39.3
+38.9
+38.6
+38.3
28 ft
-46.8
-45.6
-44.8
-44.2
-43.7
-43.2
-42 9
l�r
*-IZ:S-
-4
+43.1
+42.0
+41.2
+40.5
+40 0
+ . ,
+39.2
38 9
+3 -6+
-47.1
-46.0
-45.1
-44.5
-44 0
4 a6%
29 ft
+43.4
+42.3
+41.5
+40.8
+40.3
+ .9_
-+
9
+ 38 3i
ft
-47.4
-46.3
-45.5
-44.8
-44 3
4 9
°- `. 3'S,
2
1,19
30
+43.7
+42.6
+41.8
+41.1
+40.6
+ 02
;;r 9 5I+,y19
-48.1
-46.9
-46.1
-45.4
-44.9
.5E
444
8.
'.
32 ft
+44.3
+43.2
+42.3
+41.7
+41.2
+40.7
+40.3'
-TI 0�
35 ft
0
11
I'44 �
8
.�t�q,49t.7
+45.2
+44.0
+43.1
+42.5
+42.0
40.55
-50.4
-49.2
-48.3
-47.6
-47.1
-46.2
40 ft
+46.5
+45.2
+44.4
+43.7
+43.1
+42.7
+42.3
+41.9
+41.6
45 ft
-51.7
-50.4
-49.5
-48.8
-48.3
-47.8
-47.4
-47.0
-46.7
+47.6
1 +46.4
1 +45.5
+44.8
+44.2
+43.8
+43.3
+43.0
+42.6
soft
-52.8
1 -51.5
-50.6
-49.9
-49.3
-48.9
-48.4
-48.1
-47.7
+48.7
+47.4
+46.5
+45.8
+45.2
+44.7
+44.3
+43.9
+43.6
55 ft
-53.9
-52.6
-51.7
-50.9
-50.3
-49.9
-49.4
-49.0
-48.7
+49.7
+48.4
+47.4
+46.7
+46.1
+45.6
1 +45.2
1 +44.8
1 +44.5
60 ft
-54.9
-53.6
-52.6
-51.9
-51.3
-50.8
-50.3
1 -49.9
1 -49.6
+50.6
+49.3
+48.3
+47.6
+47.0
+46.5
+46.0
+45.7
+45.3
EXTERIOR ZONE 5 PRESSURES
Mean
DESIGNPRESSURES(PSF) - ZONES
Roof
Tributa Area 5 Ft
eight
10 15 20 25 30 351401 45
50
-50.6
0- 15 ft
+37.8
+36.8
+36.1
+35.5
+35.1
+34.7
+34.4
+34.1
+33.8
-51.3
-49.3
-47.8
-46.7
-45.8
-45.1
-44.4
-43.8
-43.3
16 ft
+38.3
+37.3
+36.6
+36.0
+35.6
+35.2
+34.9
+34.6
+34.3
-52.0
-49.9
-48.5
-47.3
-46.4
-45.6
-45.0
-44.4
-43.8
17 ft
+38.8
+37.8
+37.1
+36.5
+36.0
+35.6
+35.3
+35.0
+34.7
p'a
-52.6
-50.5
-49.0
-47.9
-47.0
-46.2
-45.5
-44.9
-44.4
�J8
+39.3
+38.2
+37.5
+36.9
+36.5
+36.1
+35.7
+35.4
+35.2
`Y19ft
-53.2
-51.1
-49.6
48.5
-47.5
-46.7
-46.0
-45.4
-44.9
+39.7
+38.7
+37.9
+37.4
+36.9
+36.5
+36.1
+35.8
+35.6
-53.8
-51.7
-50.1
-49.0
-48.0
-47.2
-46.5
-45.9
-45.4
20 ft
+40.2
+39.1
+38.3
+37.8
+37.3
+36.9
+36.5
+36.2
+36.0
-54.3
-52.2
-50.7
-49.5
-48 5
47.0-
-46.4
-45.8
21 ft
+40.6
+39.5
+38.7
+ $3..
_
�+3111 7 3�
+
-T;l..;
+36.3
-54.9
-52.7
-51.2
5 0
.:ny 01
t2"
7.5
.8
-46.3
22 ft
+41.0
+39.9
+39.1
+ 89f3$0�
t3Z.li�3J
= 7.0
+36.7
-55.4
88:0
14
7„+7,3
23ft
+41.4
+403
395
+ $,3
}
37.0
-55.9
-53.7
-52.1
-50'9
' =49�3
4
�4
-47.1
24 ft
+41.7
+40.6
+39.8
+39.2
++5538.
" �.0
+37.6
+37.4
25 ft
((
®+`&-
+42 1
+41.0
+40 2
I'M39 It
8.33
aF38�0
�37.7
-56.8
-54.6
-53.0
-Slit
•y5�'I
c19:
m 9-Zjl
°" 8 5
-47.9
26ft
+42.4
+41.3
+40.5
+39.9
+39.4
+39.0
+38.6
+38.3',
+38.0
-57.3
-55.0
-53.4
-52.2
-51.2
-50.3
-49.6
-48.9
-48.3
27 ft
+42.8
+41.6
+40.8
+40.2
1 +39.7
+39.3
1 +38.9
+38.6
+38.3
-57.7
-55.4
-53.8
-52.6
-51.6
-50.7
-49.9
-49.3
-48.7
8 ft
+43.1
+42.0
+41.2
+40.5
+40,0
+39.6
+39.2
+38.9
+38.6
-58,1
-55.9
-54.2
-53.0
-51.9
-51.1
-50.3
-49.7
-49.1
29 ft
+43.4
+42.3
+41.5
+40.8
+40.3
+39.9
+39.5
+39.2
+38.9
-58.6
-56.3
-54.6
-53.3
-52.3
-51.4
-50.7
-50.0
-49.4
30 ft
+43.7
+42.6
+41.8
+41.1
+40.6
+40.2
+39.8
+39.5
+39.2
r32ft
-59.4
-57.0
-55.4
-54.1
-53.0
-52.1
-51.4
-50.7
-50.1
+44.3
+43.2
+42.3
+41.7
+41.2
+40.7
+40.3
+40.0
+39.7
-60.5
-58.1
-56.4
-55.1
-54.0
-53.1
-52.3
-51.7
-51.0
+45.2
+44.0
+43.1
+42.5
+42.0
+41.5
+41.1
+40.8
+40.5
-62.2
-59.8
-58.0
-56.7
-55.6
-54.6
-53.8
-53.1
-52.5
40 k
+46.5
+45.2
+44.4
+43.7
+43.1
+42.7
+42.3
+41.9
+41.6
-63.8
-61.3
-59.5
-58.1
-57.0
-56.0
-55.2
-54.5
-53.8
45 ft
+47.6
+46.4
+45.5
+44.8
1 +44.2
+43.8
+43.3
+43.0
+42.6
-65.2
-62.6
-60.8
-59.4
-58.3
-57.3
-56.4
-55.7
-55.0
soft
+48.7
+47.4
+46.5
+45.8
+45.2
+44.7
+44.3
+43.9
+43.6
-66.5
-63.9
-62.1
-60.6
-59.4
-58.4
-57.6
-56.8
-56.1
55 ft
+49.7
+48.4
+47.4
+46.7
+46.1
+45.6
+45.2
+44.8
+44.5
-67.8
-65.1
-63.2
-61.7
-60.5
-59.5
-58.6
-57.9
-57.2
60 ft
+50.6
+49.3
+48.3
+47.6
+47.0
+46.5
+46.0
+45.7
+45.3
WIND VELOCITY = 170 MPH MRH <_ 60'
EXPOSURE 'C' BASED ON Kd = 0.85
ENCLOSED STRUCTURE, FLAT TERRAIN
INSTRUCTIONS FOR TABLE USE:
1. TABLES ARE INTENDED TO DERIC7-4FiiFF��NNORST CASE' PRESSURES. 'WORST CASE' IS
DEFINED AS THE CRt[3CAt GOPIbITIONOF,�ANI'i7N1�DIOWN VARIABLE AS DESCRIBED BELOW.
USE OF CRITICAL CO , DITION�.g�EQUIRE�D F,OR�U� ITH THESE TABLES.
2. TABLES VALID O L� LI(}IG'�)•OF�NJM ROOF HEIGHT AS LIMITED ABOVE.
3. TABLES VALID F RL��RROO-GF''^T;1'PES &•S'I;OOP,�S .APPLICABLE REDUCTIONS FOR ROOF SLOPES
LESS THAN 10° SHA �BE;PERFO ED%BAN,B GINEER AS A SITE SPECIFIC CONDITION.
4. IDENTIFY THE B IL NG.MEA'14 AVER/ iE) h, OF HEIGHT. IF THE MEAN ROOF HEIGHT
CANNOT BE IDENTIF ED}(U.SE+TtlEI} EAK�R00 EI T.
5. ALWAYS ROUND 1Lf300FUEIGH111 ELE VALUE OR CONSERVATIVE ASSUMPTION.
6. CALCULATE THE TR1617A8�,YaAR``EE'• 'QE E OP NING IN QUESTION (HEIGHT * WIDTH) OR
THE SPAN LENGTH (HEIGHT) MUCFI Y AN EFFECTIVE WIDTH THAT NEED NOT BE LESS
THAN ONE-THIRD SP,Q'NaL , GT +(FJEjG . 11 ).,U,S THE AREA BETWEEN STRUCTURAL
OPENINGS ONLY-NFLU EA,B aRURAL MULLS. IFTHE TRIBUTARY
AREA OF AN OPEI IN O�I�NO��TIiEYIVST CRITICAL (10 SQUARE FEET) SHALL
BE USED. ALWAYS RO �ND;IT£ TKRX`((+R+EA=D� QQ' W 0 THE LESSER TABLE VALUE. FOR LARGER
TRIBUTARY AREAS THAN 6UB SHAD, USS`FIE`LF�RGEST PUBLISHED VALUE.
7. IDENTIFY THE ZONE OF THE OPENING AS INTERIOR (ZONE 4) OR EXTERIOR (ZONE 5) PER
THE FIGURE OR INFORMATION BY OTHERS. ANY QUESTIONABLE OPENING IS TO BE
CONSIDERED THE MORE CRITICAL (EXTERIOR) ZONE.
8. READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL
MUNICIPALITY IN ACCORDANCE WITH CODE.
9. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER -DESIGNED BY A
FACTOR OF 1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALITY PRIOR TO TABLE USE.
GENERAL NOTES:
1. TABLES ARE TO BE USED IN CONFORMANCE WITH "ALLOWABLE STRESS DESIGN
METHODOLOGY" PER ASCE 7-10 SECTION 2.4.1 AND CHAPTER 30 PART 1 OR 3, USING THE
CRITERIA AS OUTLINED HEREIN.
2. DESIGN IS BASED ON THE 3 SECOND GUST (WIND VELOCITY) FOR THE WIND SPEED AND
EXPOSURE SPECIFIED. THESE TABLES NOT FOR USE WITH ESSENTIAL FACILITIES OR ASSEMBLY
OCCUPANCIES. TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. THESE TABLES
NOT VALID FOR HILLY TERRAIN. INTERNAL PRESSURE COEFFICIENT (GCPI=+/-0.18) FOR USE
WITH AN ENCLOSED STRUCTURE ONLY. VERIFY USE OF Kd (DIRECTIONALITY FACTOR) WITH
LOCAL BUILDING DEPARTMENT. HVHZ = HIGH VELOCITY HURRICANE ZONE. TABLES ARE FOR
WALLS AND VERTICAL SURFACES ONLY.
3. THESE CHARTS ARE NOT VALID AS A SITE -SPECIFIC DRAWING. THESE TABLES ARE ONLY
VALID WHEN SIGNED & RAISED SEALED BY FRANK L. BENNARDO, P.E.
4. THIS SPECIFICATION IS INTENDED TO ILLUSTRATE DESIGN WIND PRESSURES AS LISTED.
USE OF THESE TABLES AND CORRESRO DING WIND VELOCITY, EXPOSURE, AND OTHER
COEFFICIENTS LISTED)-_H IN HRCL`BE -ATE NO VERIFIED BY THE GOVERNING
BUILDING DEPARTM 0T`-AN RM � OLDER IN • - RRANN FOR APPLICABILITY OF TABLE
VALUE USE IS OFFE Dj(�R�EI�*.>
5. THIS SPECIFICA O I OT-IN,pNDE T,Q 0 ER ANY PRODUCT- APPROVED
CERTIFICATION. RE ER.�
. 3A SEP.ARA'fEl• U MITTED TEST CRITERIA AND OTHER
APPROVALS FOR DE G = NST TION�! Fla MATION AND APPLICABIL]TY OF THESE TABLE
VALUES WHICH IS T0 B V R_FIE �f3YdOTHI q ,j CCORDANCE WITH GOVERNING CODES.
6. ADHERE TO ALL /OCIM GT+t@ROTE ON$,TEM ORDINANCES.
7. NO CERTIFICATIOMI5.4F'ERED; •F R�`t" TNTt=GFF1TY OF THE HOST STRUCTURE.
B. EXCEPT AS EXPRESSLY PRO • E, IN, NO ADDITIONAL CERTIFICATIONS OR
AFFIRMATIONS ARE INTENDED.
a= SO% OF LEASTM_tj�ZvC)Nl�`AflDIAENIO�(51L9'°I¢i6jWRH, PEAK ROOF
DIMECHEVER 15 NSION OR 3FT (lYn)r41SEOE 6 (I� QUESTIONOF LEAST O CONSULT HEIGHT
EA
AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF REQUIRED. MEAN
ROOF
a a EAVE HEIGHT
1 L ROOF
I HEIGHT
5 1 ® I 5 5� ® ® 1'
L O - aSO SQ
WALL ZONE FIGURES f ISO R
v In
m > o
REMARKS
INIT ISSUE
DRWN
GSS
CHKD
TSB
DATE
03/05/12
2 010 FLORIDA BUILD
N G CODE
ENGINEERING
C
,, o
m
m " 3
c5
ASCE 7-10, CHAPTER 3
EXPR
< ON
REV- ADJUSTED HEIGHTS
GSS
TSB
04/09/12
_
IS �°z
-
_
n V)
DESIGN LOADS FOR COMPONENTS
CLADDING
160 SW 12th AVENUE, #106
ig
P. 7 I-`
I O
MASTER PLAN SHEET
DEERFIELD BEACH, FL 33442
m \ y
N
_
THIS DOCUMENT IS THE PROPERTY OF FRANK L. BENNARDO,
In
m
Z
PH: (954) 354-0660 FAX: (954) 354-0443
o o
O
o
RE AND SHALL NOT BE REPRODUCED IN WHOLE OR PART
WITHOUT WRITTEN CONSENT OF FRANK L. BENNARDO, P.E.
"ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER
ASCE 7 -
1
W W W . E N G EX P. CO M
CERT OF AUTH N9885
O
m
O W
v
MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND
i
<
I--�
m
1e 1 in- ni is roannrnTM
' noriaa tsuuamg Lone unime
Page 1 of 2
Product Approval Menu > Product or AUpllcatlon Search > Application Us t > Application Detail
rY ..,'
_ A
i RB�Rit •,.�,i �AEG7r RBPRI Uei'R p191STC1�tB CDN7!.47419P!7
FL #
FL14111-R1
Application Type
Revision
Code Version
2010
Application Status
Approved
*Approved by DCA. Approvals. by DCA shall be reviewed and
ratified by the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category'
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
JELD-WEN
3737 Lakeport Blvd
Klamath Falls, OR 97601
(800) 535-3936
fbc@jeld-wen.com
Janet Gerard
Steve Saffell
3737 Lakeport Blvd
Klamath Falls, OR 97601
(541)882-3451 Ext2900
stevesa@jeld-wen.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute,
National Accreditation & Management Institute,
Standard
ASTM E1886
ASTM E1996
ASTM E330
ASTM E331
Year
2005
2005
2002
2000
Approved Testing Lab
FL14111 R1 Eouiv JELD-WEN ASTM E1996 Eauivalencv Letter odf
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKhgANvDgZw... 3/1/2013
r lorida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option A
Date Submitted 01/31/2012
Date Validated 01/31/2012
Date Pending FBC Approval
Date Approved 02/08/2012
Summary of Products
FL #
Model, Number or Name
Description
14111,1
Gladiator/Finishield
9'-0" x 6'-8", OXX, Inswing Full Lite Door System with or
without Sidelite
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL14111 R1 C CAC NI010117.01-Ri Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
08/31/2016
Design Pressure: +35/-35
Installation Instructions
Other:
FL14111 RI II 3W062010 Dwas.Ddf
Verified By: National Accreditation & Management
Institute,
Created by Independent Third Party:
Evaluation Reports
FL14111 R1 AE PER 1569 Ddf
14111.2
Gladiator/Flnishieid
3'-0" x 6'-8", X, Opaque Inswing and Outswing Impact
Door
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL14111 R1 C CAC NI010117-R1. df
-ApPr led fo. Use outside HZrYess
ua ity Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2015
Design Pressure: +50/-50
Installation Instructions
Other:
FL14111 RI II JW152009 Dwgs.PDF
Verified By: National Accreditation & Management
Institute,
Created by Independent Third Party:
Evaluation Reports
FL14111 R1 AE PER 1570.Ddf
Created by Inde endent.Third Party: Yes
Back Next
Contact Us :: 1240 North Monroe Street, Tallahassee FL 32399 Phone: 850-487.1824
The State of Florida is an AA/EEO employer. Copyright 20D7.2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine If you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
rCreLZ
di'SArFriEj
http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsKhgANvDgZw... 3/1 /2013
c000-TM-1 NATIONAL CERTIFIED TESTING LABORATORIES
iveFIVE LEIGH DRIVE - YORK, PENNSYLVANIA 17406 - TELEPHONE (717) 646-1200
FAX (717) 767-4100
�W: www.nctlinc.com
August 19, 2011
JELD-WEN Windows and Doors
3737 Lakeport Blvd.
Klamath Falls, OR 97601
Re: ASTM El996-05 equivalence to the ASTM El996-06 or ASTM=02 test methods
To whom it may concern;
This letter is written to state that products successfully tested to the ASTM E1996-05 criteria also
meet the testing requirements ASTM E1996-06 or ASTME1996-02 up to Wind Zone 3. Products
st-meet:-additional i men s o e equivalent to ASTM E1996-06.
The revision from ASTM E1996-05 to ASTM E1996-05b and subsequent versions introduces
the additional Wind Zone 4 impact requirement that differs from previous versions: "5.3.3.6 In
Wind Zone 4, impact the integral mullion and other intermediate members such as a meeting
rail, check rail, or meeting stile mid -span...':
In virtually all methods, criteria and other aspects, the testing requirements of ASTM E1996-05
are equivalent to the comparable elements of the ASTM E19967.06 or ASTM E1996-02
requirements and methods.
Therefore, products that have passed the ASTM El996-05 testing also qualify under the aegis of
the ASTM E1996-06 or ASTME1996-02 test methods for Wind Zone 3. Wind Zone 4 compliance is only
met by products as long as the additional shot to intermediate members has been performed.
Respectfully,
NATION L CERTIFIED TESTING LABORATORIES, INC.
Ray Lamb, P.E.
Professlonols In The Science of Testing
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO:
DATE::
CERTIFICATION PROGRAM:
COMPANY:
CODE::
REVISION. DATE:
NI0:101.17-111.
02/12/2010
Structural
Jdd-Wen
104-3
01/30/2012
To verify that the "Notice of Product Certification" is valid; please visit www:NAMICertification.com to assure that
the product 'is active and. currently listed. This certification represents product conformity. to the applicable
specification and that certification criteria has been satisfied. Please review and advise NAMI if any corrections are
required to this.doeument.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
JELD WEN Exterior Doors
Series "Gladiator/Finishield" In -.Swing
3737 Lakeport Boulevard
& Out -Swing Opaque 25 Gauge
Klamath Falls, OR 97601.
Steel Side Hinged Door
Configuration. X.
I/S Frame: W-953mm (37.5") H 2O76mm(8:1..75")
O/S Fr4me.W-953n)m (37.5") H-2045mm(80.5")
SIP: Pos+3600Pa(75.0pst) Neg-3600Pa(82.5 psfl
SPECIFICATION
PRODUCT RATING
ASTM E283-04/E330-02/E331-00
Design Pressure: +501--50 psf
ASTM E1886-OS/E.1996-05b
Wind Zone 4-Missile Level D
AAMA 1304-02
FER-Passed
Product "Tested By:
Report No:
Installation Details:
Expiration Date:
.Quality Testing, Inc.
8JW2009-198
JW1520.09 (l 7)
12ecember 31, 2015
Administrator's .Signature:
NATIONAL ACC
A.TION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
1. THE PRODUCT SHOWN HEREIN 18DESIGNED TO
COMPLY WITH THE CURRENT IRC AND FLORIDA
35 3/4' MAX.
PANEL WIDTH
BUILDING. CODE (FOG) BASED ON THE SIGNED AND
SEALED DATE. PRODUCT MS BEEN TESTED TO
ASTM EMMA, E3310, E283-04, E1886-6, E1996.OSb
6 AAMA 1304:02. WIND ZONE (IND) RATING = 4
2. ZX AND IX WOOD BUCKS BY OTHERS, MUST BE
ANCHORED PROPERLY TOTRANSFERLOADS
TOTHE STRUCTURE.
3. PRODUCT ANCHORS SHALL BE AS LISTED AND
w
E
SPACED AS SHOWN ON DETAILS. ANCHOR
x Jg
p
EMBEOMENTTO BASE MATERIAL. SHALL BE BEYOND
'WALL DRESSING OR STUCCO.
C
i
4. DESIGNED PRESSURE RATING SEETABLE I, PAGE 1.
y Y
W
5. SCALE BASED ON 11X17 SHEET SIZE.
qVsaeVa
6. ALLIX & 2X TO BE 0,55 SPECIFIC GRAVITY OR GREATER.
-WATER
/
7. PRODUCT HAS NOT BEEN RATED FOR
INFILTRATION. IF AUTHORITY HAVING JURISDICT1019
NOTE 2
NOTE 2
REQUIRES THAT PRODUCT MEETS THIS REQUIREMENT,
n
PRODUCT SHALL BEMSED WHEN INSTALLED AT LOCATION
m
/
PROTECTED BY OVERHANG SUCH THAT OVERHANG (OH)
RATIO- OH LENGTWOH HEIGHT IS'I A.
�
/
f
DOOR LEAF'CONSTRUCTIOM
ACE.SHEEI THE FACE SHEETS ARE GLUED TO
11
HE CORE AND SUBSTRATE WITH LMC AOHESWE..
CORE DESIGNS THE CORE CONSISTS OF 1-1.25 POUND
DENSILY EXPANDED POLYSTYRENE (EPS).
PANEL CONSTRUCTION; EACH DOOR PANEL IS
CONSTRUCTED FROM TWO SHEETS OF 25-GAUGE (M18' MIN)
GALVANIZED STEEL. THE FACE SHEETS ARE BENT,BG• OVER
THE 1;68S' X f.0' LVL (LAMINATED VENEER LUMBER). STILES
AND TOP RAIL. THE AVERAGE MINIMUM YIELD STRENGTH OF
25 GA SHEET METAL SKIN IS 38,400 psl. THE 1.688'X1.203•
BOTTOM RAIL CONSISTS OF ROLLED-FORMEO.GALVANIZED
r GAUGE (;GIV MIN) STEEL. THE WOOD LOCK BLOCK IS
1.588' X 3 Ilex 1Y.
FRAME CONSTRUCTION: THE FRANE JAMBSAND HEAD ARE.
CONSTRUCTED OF FINGER JOINTED PINE, THEINSW9VG
SILL IS COMPRISED OF COMFOSITE MATERIAL WITH
-ALUMINUM CLADDING AND A PLASTICADJUSTABLE HEIGHT
THRESHOLD. THE OUTSWING SILL IS COMPRISED OF
COMPOSITE MATERIAL WITH ALUMINUM CLADLXNG. TOP
CORNERS ARE COPED, BUTTED, SEALED USING SILICONE
AND FASTENED USING FOUR 18 GA 7116'. X 2' LONG
STAPLES PER TOP CORNER. BOTTOM CORNERS ARE
COPED, BUTTED, SEALED USING SILICONE AND FASTENED
USING THREE 16 GA. 7)15' X Z LONG STAPLES PER BOTTOM
CORNER. ALL FRAME JOINERY ARE SEALED AT THE
EXTERIOR USING DOW 1190 SIUCONE,
SINGLE UNIT (X)
(INSWING IMPACT)
ceffamNO.
ReviewedBy
Daie Reviewed:
NOTE.-
1. ALL VIEWS FROM INTERIOR.
2- MASONRY AND CONCRETE CONSTRUCTION.
TABLE'1
DESIGN PRESSURE RATING
DESIGN PRESSURE RATING:
SINGLE DOOR ONLY
INSWING
POSITIVE
+50
NEGATIVE
.50
IOUTSWNG
POSITIVE
.
NEGATIVE
-50 1i1u11u,
ALEX SPYROO
2012.01.232202:46-05W
_ 1
r
O
J0
�D O
cq
Z WSccoo
W nYd
Ecma, S.FREY )
JWIM9
UT OF
1' MIN.
1` MIN
NOTE
1�
MIN.
'MIN
1' MIN
NOTE 1
DESCWPIN
Makdaf
F8N 1M78 f 11!• INTED P1N TREATED)
PINE
'
Lu
NOTE2
21 27.
ATE 2
9 2'1 27
r
I t F NTED PINE, TREATED)
pin
'-
8
3
LATCH PAM •145i4Nd'PINGERKBMTEO PI TREATED
PINE
,A
a �.'
'
n
4
OUFSMNGTH 6 MODEL tt T! TliH;O.iLPOSITE
ILL LONUM
" •�.) •
CI
[i
5
810PIALIPS('LATNFJNLYOODSC WRHit1TMINEMBEGMENT
STEEi.
f
•
J
0
B
x4lM 3IGEL2GA . M
EL
1
2
�: 1,
m
}:-
T
N9x 4•PHRIAPSFLA HEADWOOD
STEEL
8
N10xI4f!'PHALB�SFLA
STEEL
.;
I
m 1
. 22'
U CC J
Z 4 Q
3H8"ITY TAPCLN WRH I IH' MIN:EMSEDMENT
STEE
'
2
4' LL CU
,Z" W . co
10
COM WFATHERSTMP W 8850
11
Ik.4 ENDU O-?A 120 T5!OOMPOSITE
ALUM NUM
SEE DETAIL A
SHEETB
: 5, .;-
:,..,
12
Z
�[.
x
:s:,..
}—
?� g.a�
12
TOP FWL WATEOVO4URUNSER
V<
BOTTOM V
STEEL
10 :•,,• :.f''
•
;'
12
Q n �
14
H9169 $ME WILE MINATED VENEER LWBER
LVL
x,, ;
; ;
15
LATCH SIDEST0.E TEOVEWERLUMBE
LVL
r �
;'•;'"'
' YOB.
16
K z Ir TREATED
PINE
_,.�;'
S
DETAILA
x•' i ;
STEER
SHEET6
10
::.n`:;•
18
KMKSETLOCKSER0400
STEEL
KMKSETDEA0S0.TSEPoES660
STEEL
_L9L
20
N8 x2' PHI! M FIATNEAO W000 SCFMW
EL
Z. :
21. 2"WOOD BUCK GRAD£2 SOVniERN YELLOW KN TRPATW WOOD
��.+••+ ,
:•.-�;:
23
EXPANDED DED POLYSTYRENE TO 12Ubs 0 WO BY'JEIDN'EN FOAM7
p
O
':`�Y-'
24
STEEL DOOR PANEL SIGN MATERIAL ta5 GAGALVANQED) STEEL
M52500MMERCNI:OUAUTI'OAfB'MW.THICIL} GALY
aQL
25
OJSWINLiWMDOOR BOTTOM SNEFP YIN-
of
COO)
rn
CORNER PADS 7, LOCATED AT TWOOT000FEACH 44M LEG FOAM
rj�
OW
U.1
WI
•:,
_
ui
I
rc
ID
t7
O
27
SETMONTOROF7KSlLL DOWTHEWEARiMU RIP
OPTK}HALIXWOOD BUCK GRADE250 YELLOW PNE TFFJLTEO
:=. ,T,.
rn qN
a
_ Z
70
ERN
DEAD SOLT PLAT
c��y
- W� 2
�[y
;•
fl
W
a.W
m J
es�
ID
CA
�1.T1•l�
�.. �i'..
24
-L.f.
23
i•.`.
7W.
opp
z
+z
LA
W
11
NOTE 1; 1X MAY B,E.UTILIZED AS AN OPTION AS LONG ASij�j18ANCHORI
21 :27
t `1112"
EMBE}AENT j$i!E
DEPTH, INTO MASONRY, CON`lP
SEE NOTE 1
EM ,
NOTE2:
MJUN IMED
OPTIONALLY, ANCHOR CAN BEFLACM 1 .WiEitybOE EAD
ay
0{i JAMB ' o
5
MIN I
d
. ro. y
rrAtE
12 18
09
acne 3'n.i•
?'MIN —'7
.9'• FATE OF :�144
}'MIN --) ' —'2+i��ss�:•.RC?���,
et4 S. FREY
ZLVERTICAL
CROSSSECTION.DOORTYP_
�MIN.
rxxF
DPAfiMNW
2 WOOD FRAME INSTALLATION
Ln'I-VERTICAL CROSS'SECT}ON DOOR TYP,
HA. IRV
2 MASONRY AND CONCRETE INSTALLATION
Bs+a1nDm.
1zr w:ere.!a+n+ saiu
JW152009
tnanoa,Fcun9
R9E Cab NA�Y,mnaonHa 2151!
s>�sr aF 7
. rjuw�wwu w 1w�u
Gaon NoyRwew0 1
Date Red�
z.
SEE NOTE 1. 2t 1 114*
MIN. EMIL
1/4` MAX
SEEDETAILA SWM
INTERIOR�V
A VIEW
A DOOR
HINS SECTION
3 VIEW AT DOOR HINGEtSiDE JAMB,
(MASONRY AND CONCRETE INSTALL)
d
1117
SMOETAILA 6SHEETS
OPTIONAL MASONRY AND. CONCRETE INSTALLATION
FOR HEADERSAND.JAMBS
SJEE NOTE 2 S 3. THIS PAGE
SHIM
11(l
SEE DETAIL A t
Mw. EMS.
1 ire
SHEETE
.
MIN. Ems,
3
Iw
L
' 4M14
'aINTERIOR
NOTE 1
S
SEE NOTE 1 21
o_ 1 HORIZONTAL CROSS
SECTION
3 V.IEW AT DOOR HINGElSIDE JAMB
3
(WOOD INSTALL)
I
L
7 ti4•
MIKEMB.
1W MAX SEE DETAIL A
Hsi SHEETS
O
tj, In
SEEDETAILA
SHEETS
A.
z�
r35 4
10 18 76
0
m O
15 18 f8
a
F- VJ +-
Y9
n, 7
�e Z
d 'Y'l Jf,�+✓ipPyA,
Loll LL m
I to
0 INTERIOR
INTERIOR
� f` '�
28
EE.NOTE 1
W h J =
CROSS SECTION
D I
L CROSS SECTION
Lu t9 Y 0.
RLL TCHISIDEJAMB
3. VIEWATOOORLATCHf51DEJAMB
(MRSONRYAND CONCRETE:INSTALL)
Adckft toMMI
CerhfaftNo.:
Reviewed Bp;
Date RW : -- o
NOTES:
1.1X MAY SE UTILIZED AS ANOPTION AS LONG AS MINIMUM ANCHOR
EMBEDMENT DEPTH, INTO M4O?iRY,.CONCRETE, ORWOOD,
IS MAINTAINED.
2 OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW SECTION OF
HEAD ORJAMS AS LONG.AS MIN. EDGE DISTANCE IS MAINTAINED.
:3. TAPCON SPACING BETWEEN ANCHORS SAME AS WOOD
Na
WJW
QQW
�qq
N
W% �N
00
N�N N♦UU-
�'WY
(_i d!
500 go
29�.
JW152009
1' MIN
MN
NOTE 2
iO
1. IN,
1'MIN.
5
21 27 NOTE 1
m
1. MIN.
1" MIN.N07E 2
g
W
9
31 27 OTE 1
2
♦' .d �. mod.• �
114' MAX
SHIMTHK _
I
22
°E DETAIL
A :7;-
12
,
SHEEP B
y +-::
2
`'• '.
Y
12
K.
SEEDETAILA
-S"
10.
SHEEfS
ce
¢I ¢� i
W L� J
LA L VERTICAL CROSS SECTION, DOOR 1YP.
4 WOOD FRAME INSTALLATION
(SCALE: Varl •0`)
K
Oa
a
zzx
n.
24
10 13
•t i
4'
r
g
MIN
•
MIiJ
1
'
L ]_YERTICALCROSS.SECTION. DOOR
TYP.
4 MASONRYAND CONCRETE INSTALLATION
(SCALE:3" '-W)
W ND-'
i1l�G,,Y��irolpitlJu�.u.
LJGtC n�C0017.
371f2' MAX
OVERALL FRAME
WIDTH
Ir X.
PANEL WIDTH � I
19
18 \
r a
°P w
J
NOTE 2 l NOTE 2
a / n
NOTE 2
(EXTERIOR VIEW)
SfwLE LNITIXI
OUTSWING IMPACT
(SCALE. Z"-11-01
Y
m
rn
-" 0
d it :1
20c
Z IL
w Y H�
to
LU :' i
j min.
QW
U �z
ay Z'p
JUMM. 9Y=
W rWo td? ���jjj N
2W2 L7�
as
m 3
ooQ W ?�
of pg
o >
NOTE 1: 1X MAY BE UTILIZED AS AN OPTION AS LONG AS MINI6NM ANCHOR
EMBEDMENT DEPTH, INTO MASONRY, CONCRETE, Oft W000.
NOTE2: OP ONALL ANCHOR CAN BE PLACED INNARROW SECTION OF HEAD
q
OR JAMB
NOTE3: MASONRY AND CONCRM.gQ 5TRUCTION.
No
0152009
vw4_r- 7
SEE NOTE 1(21 1 iN•
MBd. EMB.
174' MAX
�TAICA Sl4M
.. .. z I
, 9 �W S
oUh
EXTERIOR T g
I h \UQR1YONTALCROS, SECTt0N
5. VIEWATDOOR HIMGEISIDE.JAMB
(MASONRYAND CONCRETE)NSTA11)
1' MIN.
TMIN.
a
SHIMTHK, 1 UL'JuIJ
SEEOETAILAJ I�
SHEETS
OPTIONAL'MASONRYAND CONCRETE INSTALLATION
FOR HEADERS AND JAMBS
SEE NOTE 2 R 3, THIS PAGE
SFi1M_
SEE DETALA
MPO. EMS.
.SHEETS
N,
5
EXTERIOR 7 S 8
1 SEE NOTE 1
SEE
HORIZONTAL CROSS
BeV1EWAT
SECTION C
POOR HINGEISIDEJAMB E
(WOOD INSTALL)
CAM ft
Reviewed By.
Dale Rev 691-
il,V MAX.
-SHIM
SEE DETAIL A
EXTERIOR
JAMB
1I 1!4'1• SEE*DETAILA
otEMB: FPM SHEETS
r
O
�
t0 18 16
J 0
m
z0
icm
IL
48
EENOTEI
M
D
6
VIEW AT DOOR LATCHISIDE JAMB
.
.
(MASONRY 'A AND CONCRETE INSTALL)
NOTES: .
1. IX MAY BE UTILIZED AS AN OPTION AS LONG AS MINIMUM ANCHOR
EMBEDMENT DEATH, INTO MASONRY, CONCRETE, OR WOOD,
19 MAINTAINED.
2.OPTIONALLY. ANCHOR CAN BE PLACED IN NARROW. SECTION OF
HEAD OR JAMB AS LONG AS FAN. EDGE. DISTANCE IS MAINTAINED,
3. TAPCON SPACING BETWE1;C{ ,ngRS.SAME AS WOOD
SCREW CONF.IGURATI%4! 4I%S SPv�?i..
1 01.52009 1
SEE DETAIL B
0
a
, w
a
. I m
1
MAX,14' �
O.C. TYR iO
.1 I
rH
w T_ �
y � � SEE DETAIL C
ANCHORING LOCATIONS SINGLE
I�N��3�NGUNITM
SCALE, 318• -t'-0'
YlVCSINK. OTE
/ USE 8111 WOOD. INSTALLATION SCREW W11.50' MIN. EMBEDMENT
j WHEN INSTALLING INTO WOOD SUBSTRATE AT HEAD & JAMBS, n
\ J USE 31Q8' ITW TAPCON ANCHOR W! 1 114' MIN. EMBED. p
WHEN INSTALLING INTO CONCRETEIMASONRY SUBSTRATE. AT SIDELITE SILLS.
DETAIL- A • SCREW AND TAPCON ANCi HRRS.CAN BE EMBEDED IN EITHER THE 1114' OR m o
SCALE 8'?1'-0' 314' THICK PORTION OF THE JAMB AS LONG AS THE SUBSTRATE EMBEDMENT
IS MAINTAINED. Z 0 J
Z iJJ LL m
LU Y o0
4 11 S' �.QsM
M sea.
CEtfiC211 No,:
Reviewed By:
NOTE
02y p
[g��C - wit d
AT HEAD CpOREIEL DETAIL AT SILL .N Q
0 05 $d
7 20S$QR ¢
D DETAIL Ti E �
3TA11 LATCH
TR E PLATES OLT z
NOTES;
1-ANCHOR SPACING FOR BOTH INSWING &OUTSWING,
2-ONLY 2 STAej0nftQQRNERAT SILL FOR OUTSWING.
No
pK.sr: S. FREY
oMMORW
JW152009
}�-- 49116' -►1
1 WOOD JAMB FINGER IOfNTED PfNE
SCALE: 6'=1'-W
2
3
i/8' i 318'
t 11111r
LATCH STLLE
TOP RAIL
1.2 14 i5 EST
LAMINATEDD
YEFQeER LUMBER (LVL)
SCALE: 6' =1' lr
N O O
Blf�l�jlI F4012G STFL
J SCALE:6' a1 D'
�:3118' --I
18 FINGERJOIN7 PINE
SCALE 6' =1
r 1:374•
718"
1
ODOOR BOTTOM CEP
25 VINYL
SCALE: 6' 4-0'
1N
1
CORNER PADS
'PLASTIC
SCALE: 6"3T-0'
5 5J8
k
M
113T--rr 3 Ur
O
v G�
OLATCH PLATE
STEEL
SCALE: 6 =1 W
Reviewed tf.
Date Reviewed
AddBi)dum t0
8� � �'I 11116• —I
I o
n
m
FOAM O t�
SCALE: 6'=1'-0" W i<L cV�
1S BOTTOM RAIL LU:W.s� cQ
25GkSTEEL y
SCALE:6'aT-0' Zy
, M5
57
Br:
,AN152809
ALEX S
2012.0
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Product Evaluation Report
Of
127 W. Fairbanks Ave.
Suite 438
Winter Park, FL 32789
407.644.6957 PH
407.644.2366 FX
contact@buildingdrops.com
JELD-WEN, inc.
Gladiator/Finishield Wood Edge Steel Door
YRO U
22:0,3�46 -
3
for
Florida Product Approval
FL# FL14111
Report No. 1570
Flnriria Building _
Per Rule 9N-3
Method:
1— A (Certificate)
Category:
Exterior Doors
Sub — Category:
Swinging Exterior Door Assemblies
Product:
r
Gladiator/Finishield
Material:
Steel/Wood
Product Dimensions:
37.S" x 81.75"
37.5"x 80.5"
1
Prepared For:
JELD-WEN, inc.
3737 Lakeport Blvd.
]Klamath Falls, OR. 97601
Prepared by:
Alexis Spyrou, P.E.
Florida Professional Engineer # 68101
Date: 12/01/2011 .
Contents:
Evaluation Report Pages Y— 4
Installation Details Pages 5
Alexis Spyrou, P.E.
Florida No. 68101
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Manufacturer: JELD-WEN, Inc.
Product Category: Exterior Doors
Product Sub -Category: Swinging Exterior Door Assemblies
Compliance Method: State Product Approval Rule 9N-3.005 (1)(a)
Product Name: Gladiator/Finishield Opaque Wood Edge Steel Door
(Impact Rated)
37.5" x 81.75"
37.5" x 80.5"
FL#:FL14111
Date: 12/01/2011
Report No: 1570
Scope: This is a Product Evaluation Report issued by Alexis Spyrou, P.E. (FL # 68101) for Jeld-Wen Inc. based
on Rule Chapter No. 9N-3.005, Method 1a of the State of Florida Product Approval, Department of
Community Affairs - Florida Building Commission.
Limits of Use:
Alexis Spyrou, P.E. does not have nor will acquire financialing or
u ing a pro uct or in any other entity involved in the approval process of the product named
herein.
This product has been evaluated for use in locations adhering to the 2007 & 2010 Florida Building
Code.
See Installation Instructions JW152009, signed and sealed by Alexis Spyrou, P.E. (FL # 68101) for
specific use parameters.
1. This product has been evaluated and is in compliance with the 2007 & 2010 Florida Building
Code, excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the 2007 & 2010 Florida.Building Code and does not require an impact
resistant covering.
4. Site conditions that deviate from the details of drawing JW152009 require further
engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions JW152009 for size and design pressure limitations.
Alexis Spyrou, P.E.
Florida No. 68101
Page 2 of 5
BUILDING DROPS FL#: FL14111
A Perfect Solution in Every Drop Date: 12/01/2011
Certificate of Authorization: 29578
Report No: 1570
Quality Assurance: The manufacturer has demonstrated compliance of door products in Accordance
with the Florida Building Code and Rule 9N-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
National Accreditation & Management Institute, Inc. (FBC Organization #QUA1789)
Performance Standards: The product described herein has been tested per:
0 ASTM E 283-04
• ASTM E 330-02
• ASTM E 331-00
• ASTM E 1886-05
• ASTM E 1996-05b
Referenced Data:
1. Product Testing performed by Quality Testing Inc.
(FBC Organization # TST7638)
Report #: SJW2009-198, Report Date: 1/18/2010
2. Quality Assurance
National Accreditation and Management Institute
(FBC Organization #: QUA 1789)
Alexis Spyrou, P.E.
Florida No. 68101
Page 3 of 5
BUILDING DROPS
Certificate of Authorization:
A Perfect Solution in Every Drop
29578
Installation: 1. Approved anchor types and substrates areas follows:
FL#:FL14111
Date: 12/01/2011
Report No: 1570
Through Frame Installation:
A. For two by (2X) wood buck substrate, use #10 Wood Screw type installation anchors of
sufficient length to achieve a minimum embedment of 1.50" into the wood substrate.
B. For concrete or masonry substrate where one by (1X), non-structural, wood bucking is
employed, use 3/16" diameter ITW Tapcon type concrete screw anchors of sufficient
length to achieve minimum embedment of 1.25" into concrete or masonry.
C. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16"
diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve
minimum embedment of 1.25" Into concrete or masonry.
Refer to Installation Instructions (JW152009) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Design Pressu
Positive f 50 PSF*
Negative 50 PSF
*Product has not been rated for water infiltratio author" aving jurisdiction requires that
product meets this requirement, product shall be used w en installed at location protected by
overhang such that overhang (OH) ratio = OH length/OH height is 1.0.
Alexis Spyrou, P.E.
Florida No. 68101
Page 4 of 5
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Installation Method
JELD-WEN, inc.
Gladiator/Finishield Opaque Wood Edge
3-0 x 6-8 Inswing/Outswing
25 Ga. Steel Impact Door System
fi
ir)
T
uO
37 1 /2" MAX
OVERALL FRAME WIDTH
3" TYP.
i
FL#:FL14111
Date: 12/01/2011
Report No: 1570
Alexis Spyrou, P.E.
Florida No. 68101